| 1 | Demolishing mud phuska in terracing and disposal of material within 50 metres lead. |
| 2 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 3 | Cutting /removing of plants and grass growth on bldg's roofs, chajjas and edges on bldgs,work shop, hangers (at any floor and any height) including spreading chemicals at plant roots area and finished the damaged area with PCC 1:2:4/ Cement plaster in CM 1:4 as required and remove the waste to distance n exc 50m, complete all as specified and directed by Engineer-in-Charge. |
| 4 | Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in-charge. |
| 5 | M&L Grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 20mm nominal size). |
| 6 | 15 mm thick cement plaster of mix : 1:4 (1 cement: 4 fine sand) |
| 7 | M&L for repairing the edge/corner of chajja/roof projection and similar work by removing of plastered width/girth exceeding 15cm & n.exc 30cm and making good with 15cm rendering in cement mortar (1:3) to match with including kitchen wiremesh netting on exisiting surfaces including necessary form work complete all as specified.Note:-(Work shall be carried out upto G+2 storey bldg, contractor to quote rates accordingly). |
| 8 | M&L for APP based polymeric membrane minimum weighing 3Kgs/Sqm and minimum 3 mm thick reinforced with polyster non wove fabric (wt not less than 150 gms/sqm) over a coat of hot bitumen 85/25 grade applied @ 1.20 Kg/Sqm after priming the surface with bitumenious emulsion (tack coat) @ 100 gms/sqm with 10 cm overlap of the membrane to be provided duly fused uniformly by LPG torch flame complete all as directed . |
| 9 | Supply only liquid water proofing compound. |
| 10 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 11 | Providing and fixing 20 mm nominal bore, 120 mm long, weighing not less than 198 gms PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball |
| 12 | Providing and fixing 20 mm nominal bore gun metal gate valve with C.I. wheel of approved quality (screwed end) |
| 13 | Dismantling of 150mm dia PVC rain water pipe with fittings and clamps including stacking the material within 50 metres lead. |
| 14 | S & F PVC (SWR) pipes 160mm bore, single socketed in any length with rubber ring joints fixed to wall or laid in floors including taking down old pipe complete all as directed. |
| 15 | S&F 160mm PVC (SWR )bends with access door of any radius all as specified & directed. |
| 16 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. |
| 17 | Providing and fixing 12.5 mm thick tapered edge Glass Reinforced Gypsum (GRG) board conforming to IS: 2095- (Part 3):1996 (Boards with BIS certification marks) false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting . |
| 18 | Providing and fixing 18 mm thick Granite stone slab colour black, Cherry/Ruby red gang saw cut, mirror polished, premoulded and prepolished, Area of slab over 0.50 sqm, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. completeat all levels. |
| 19 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 20 | P & L 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 21 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead of area 3 sq. metres and below |
| 22 | Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.80 sqm). |
| 23 | Brick work with clay flyash F.P.S. (non modular) brick of class designation 7.5 in superstructure above plinth level up to floor five level in Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 24 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in cement mortar 1:4 (1 cement : 4 coarse sand) |
| 25 | 15 mm cement plaster in 1:6 (1 cement : 6 fine sand) |
| 26 | M&L white washing with lime to give an even shade on New work (three or more coats) |
| 27 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth. Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives on New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm complete all as specified. |
| 28 | Providing and laying Non-Skid Ceramic floor tiles of size exc 0.11 Sqm but n.exc 0.18 Sqm(thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 29 | Providing and fixing 1st quality ceramic glazed wall tiles in vertical surface 300 x 600 conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete |
| 30 | Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, Providing and fixing factory made P.V.C. door frame of size 50x47 mm with awall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineerin-Charge |
| 31 | Providing and fixing to existing door frames 30 mm thick factory made Polyvinyl Chloride (PVC) door shutter made of styles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2 mm (± 0.2 mm), with inbuilt decorative moulding edging on one side. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x30 mm and 2 mm (± 0.2 mm) wall thickness fixed to the shutter styles by means of plastic/ galvanised M.S. 'U' cleats The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness . The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge. |
| 32 | Providing and fixing 100x75x3.50 mm ISI marked, IS : 1341, M.S. heavy weight butt hinges with necessary screws etc. complete |
| 33 | Providing and fixing 250 x 10 mm aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete |
| 34 | Providing and fixing 125mm aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete |
| 35 | Providing and fixing 15 mm dia nominal bore G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : |
| 36 | Providing and fixing 20 mm dia nominal bore G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : |
| 37 | Providing and fixing 25 mm dia nominal bore G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : |
| 38 | Providing and fixing 25 mm nominal bore gun metal gate valve with C.I. wheel of approved quality (screwed end) |
| 39 | Providing and fixing counter wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require , White Vitreous China Flat back wash basin size 550x 400 mm with pair hot and cold of 15 mm C.P. brass pillar tap. |
| 40 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid |
| 41 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required , Single half stall urinal with 5 litre P.V.C. automatic flushing cistern |
| 42 | Providing and fixing 15mm nominal bore C.P. brass bib cock of approved quality conforming to IS:8931 |
| 43 | Providing and fixing 15mm nominal bore C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931 |
| 44 | Providing and fixing square-mouth S.W. gully trap class SP-1 180x150 mm size P type complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 45 | Providing and fixing soil, waste and vent pipes 100 mm diameter Sand cast iron S&S pipe as per IS: 1730 |
| 46 | Providing and fixing plain bend of required degree 100 mm diameter Sand cast iron S&S pipe as per IS: 1729 |
| 47 | Providing and fixing uplasticised PVC connection pipe with brass unions 15 mm nominal bore 45 cm long. |
| 48 | Providing and fixing PTMT grating circular type of approved quality and colour 125 mm nominal dia with 25 mm waste hole. |
| 49 | Providing and fixing PTMT towel rail 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour |
| 50 | Providing and placing 500 ltr capacity PVC tripple layer water tank on terrace (at all floor levels) , IS : 12701 marked, with cover , tank connector and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes including fittings and fixtures complete all as specified and directed. |
| 51 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screwsProviding and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 52 | Making plinth protection 50mm thick of cement concrete (1:3:6) (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 53 | Providing edge moulding to 18 mm thick granite stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge |
| 54 | Dismantling doors, windows and clerestory windows (steel or wood) shutter of area 3 sq. metres and beyond including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead |
| 55 | Supply & fixing of UPVC windows three track sliding window with two glazed and one wire mesh sliding shutters of profile width of frame 50 mm to 60 mm, limit thermal conductivity to l.3 Kcal/sqm/hr centigrade, sound insulation up to 4-0 bds, Density, 1.46 gm/ml, Tenstile strength - 43.9N/sqmm, % Elongation at break - 215, Tenstile mpduls - 2840N/Sqmm, Flexural strength - 51N/sqmm, Heat aging at 150 degrees - No surface defect, Thickness - 2 mm, Flexural moduls elasticity 2200N / sqmm, double baskets & wool pile on window, multi point gear locking at different sides of frame, anti lift device on slide windows with temper proof screws with and including glazed shutter fixed with 5 mm thick plain sheet glass & wire mesh shutter with stain less steel wire cloth 304 grade stainless steel with 0.254 mm (30 gauge) dia of steel wire and 0.95 mm width of aperature and filling gap of wall and frame with silicon sealent complete incl taking down old down old window complete all as specified. all as directed . |
| 56 | Providing and fixing to existing door frames 30 mm thick factory made Polyvinyl Chloride (PVC) door shutter made of styles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2 mm (± 0.2 mm), with inbuilt decorative moulding edging on one side. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x30 mm and 2 mm (± 0.2 mm) wall thickness fixed to the shutter styles by means of plastic/ galvanised M.S. 'U' cleats The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness . The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge. |
| 57 | S&F framed work such as grills, gratings etc with ends of bars shouldered and / or riveted or forged into spikes, framed guard bars, barred iron doors, ladders framed balusters, walk ways conforming to Fe-410-0 or Fe-310-0 |
| 58 | S&F in repair printed roller blinds with all fittings (to be matched with existing patterns) & taking down old venetian blinds complete all as specified and as directed by Engr-in-Charge. |
| 59 | Hardcore of gauge exc 63 mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface |
| 60 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 75 mm thick with 20 mm nominal size stone aggregate |
| 61 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. |
| 62 | Dismantling Asbestos Cement sheet roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of all as specified. |
| 63 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposaal of surplus excavated soils as directed, within a lead of 50m in ordinary rock. |
| 64 | Removing excavated soil to a distance n.exceeding 50m and depositing where directed at level n.exc 1.5m above starting pont complete all as specified and directed |
| 65 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete |
| 66 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 67 | Providing & fixing at all heights, levels and locations colour finish Aluminium alloy roofing sheets of alloy IS designation 31500, temper Hx8 conforming to IS 737 and dimensions as per IS code 2676 with characteristics of good formability and corrosion resistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex cap headed self drilling/tapping Stainless steel screws M6, 50 mm long with 3 mm EPDM seal washer etc. all inclusive of labour, scaffolding, T&P and sundries etc. complete as per directions of the Engineer-In-Charge. (Cost of truss/frame work shall be paid separately). 12.65.1 0.56 mm, Aluminium Color coated troughed profile with center to center pitch of 200 mm, depth of 32 mm, overall profile width1092 mm, cover width 1000mm. sqm |
| 68 | Providing and fixing 18-25mm thick Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar (1:4) (1 cement : 4 coarse sand) complete all as specified. |
| 69 | Distempering with 1st quality acrylic distemper (ready mixed) Two or more coats on new workhaving VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. |
| 70 | Distempering with 1st quality acrylic distemper (ready mixed) Two or more coats on old workhaving VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. |
| 71 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratched etc. Providing and applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surfaces even and smooth. Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including water thinable priming coat with cement primer complete all as specified. |
| 72 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two or more coats on new work With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works incl preparation of surface. |
| 73 | Point wiring with 1.5 Sq.mmm copper conductor FRLS (multistranded) PVC insulated ISI marked unsheathed cable of any length drawn in and including concealed non metallic rigid PVC conduit of not less than 25mm dia ISI marked with all fitting and other accessories and also including PVC insulated ISI marked unsheathed FRLS cable size 1.5 sqmm copper conductor as earth wire to common earth dolly including galvanised terminal boxes ISI marked fixing into the wall of sizes as required at site and modular plates and frame suitable for fixing switches / sockets / fan regulators etc, and making good the disturbed surfaces matching to the existing surface for one light point/fan point/bell point controlled by one way modular switch 5 Amps 240 volts, complete all as specified and directed |
| 74 | One 3 pin socket outlet 5 Amps on the same board with other switches. |
| 75 | One 3 pin 5 Amps switch socket outlet point on independent board |
| 76 | All as per SI Item No. 1 here-in-before but wiring with 4 Sqmm for 15 Amps modular 3 pin socket outlet on independent board / two pin earth plug and socket including providing 4 Sq.mm PVC insulated multistranded unsheathed FRLS copper earth continuity conductor and connected to common earth dolly, complete all as specified and directed. |
| 77 | Supply & Fixing Modular switch, one module, one way 6 Amp, 240V, complete all as specified and directed. |
| 78 | Supply & Fixing Modular switch 16A, one way, one module, 240 Volts, complete all as specified and directed. |
| 79 | Supply & Fixing Modular step type, electronic fan regulator, two module, 240 Volts, complete all as specified and directed. |
| 80 | Supply & Fixing modular socket one way 6 Amps, 2/3 pin combination 2 module, complete all as specified and directed. |
| 81 | Supply & Fixing modular socket, 6A/16A - 2 /3 pin combination 2 module, complete all as specified and directed. |
| 82 | S&F ceiling rose two to three terminal surface backallite type AC 50Hz 230 volts complete |
| 83 | S&F 1x20W,230V, 6500K CCT surface mounted integral LED batten with extruded aluminium housing with inbuilt electronic driver, polycarbonate diffuser including connecting up with twin core twisted flexible copper condctor cable from ceiling rose to fitting all as specified. |
| 84 | Supply and fixing 240V, 10 KA 'c' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning. |
| 85 | Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of 2 pole and 63 amps current carrying capacity in the MCB DB complete with connection testing and commissioning. |
| 86 | Supply and fixing factory made epoxy powder coated Distribution Board SPN 04 way double door ( MCB DB ) MCB DP as In comer, with 200 Amp bus bar, metal door (IP-43 protection, IK-09)as per IES-61439-3 fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockout semi flush to wall and making good disturbed surface and touch up with the same finishes complete complete all as specified Note: MCBs will be measured and paid seperately under respective Sch A item in the schedule |
| 87 | M&L sub main wiring with PVC insulated FRLS grade cable LT 1100 Volts grade PVC insulated unsheathed, multistranded with stranded copper conductor drawn in & including concealed type medium grade PVC conduit not less than 20mm ISI marked with all accessories and incl cuttting and chasing of any type of wall and making good to match with the existing surfaces alongwith one contineous earth wire and connected to common earth complete all as specified for following sizes of cable :- |
| 88 | 2 x 2.5 sq mm with one continous earth wire of size 2.5 sq mmNote : 2 runs of 2.5 sq mm cable and one run of 2.5 sq mm earth wire and PVC conduit will be measured as one meter. |
| 89 | 2 x 4 sq mm with one continous earth wire of size 4.0 sq mm Note : 2 runs of 4 sq mm cable and one run of 4.0 sq mm earth wire and PVC conduit will be measured as one meter. |
| 90 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers |
| 91 | Supply & Fix Security light fitting 35 W IP 66 protection, color temp (Cool White) pressure die cost aluminium body with high power LEDs as light source and tranparent diffuser, inbuilt electronic driver and luminous efficacy of 120lm/watt fixing on the GI bracket of not less than 25mm dia bend to shape as required at site and fixing with nexcessary GI clamps on the wall including connecting up with three core copper cable all as specified and directed. |
| 92 | M&L for earthing complete with galvanised steel, earth plate electrode 600x600mm x 6mm thick burried directly in ground verticaly (earth pit not less than 2.25 mtrs below ground level ) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to galvanised iron 32 x 6 mm strip as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in electrical plate No 3 on page 497 of MES schedule 2009 part - I connected to main switch board/main DBs/earthing test point including all necessary excavation and earth work in hard/dense soil common salt and charcoal dust mixed and packed 150mm thick all round the GI earth plate, watering pipe 20mm dia GI medium grade. GI sheet 0.63 mm thick funnel, wire gauge, 50mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round bars 6mm dia @ 150c/c both ways and pit/chamber in PCC 1:3:6 type C1 with suitable lifting handle to cover, GI protection pipe 40mm dia light grade up to 7.5mtr from electrode GI pipe to be fixed with complete all as specified and directed. |
| 93 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply earthing complete all as directed.Make: Havells/Crompton/Bajaj/Orient or its equivalent Please Enable Macros to View BoQ information |