| 1 | Excavation in trenches not exc 1.50 m wide and not exc 1.50 m deep for foundation, laying of pipe or for shafts, wells cesspits, man holes, pier holes, laying of cable etc not exc 10 Sqm on plan and n exc 1.5m in depth and getting out in soft / loose soil complete all as specified and as directed. |
| 2 | Excavation in trenches not exceeding 1.5 m wide for foundation or for shafts, wells, cesspits, manholes, pier holes etc. not exc 10 sqm on plan and exceeding 1.50 in depth but not exc 3.0 m and getting out soft/loose soil complete all as specified and directed |
| 3 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm in soft / loose soil complete all as specified and as directed. |
| 4 | Removing excavated soil to distance not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting point etc complete all as specified and as directed. |
| 5 | M&L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and as directed. |
| 6 | M&L for hard core with broken stone or boulder of gauge not exc 63 mm, deposited , spread and levelled in layers n. exc 15 cm thick, watered and rammed to a true surfaces complete all as specified and as directed. |
| 7 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as directed. |
| 8 | M&L for PCC 1:4:8 Type D-2 ( Using 40 mm graded crushed stone aggregate) as in foundation , filling, and mass concrete complete all as specified and directed. |
| 9 | M&L for PCC 1:3:6, type C2 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete etc. complete all as specified and as directed. |
| 10 | M&L for 75mm thick PCC 1:3:6, type C2 (using 40mm graded crushed stone aggregate) as in plinth protection, etc finished the surface even and smooth without using extra cement including provision of joint of size 10 mm wide & 10 mm deep and filling with bitumen mastic joint filling at every 3m length and at corners complete all as specified and as directed. |
| 11 | M&L for PCC 1:2:4, type B2 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete etc. complete all as specified and as directed. |
| 12 | M&L for 100 mm thick PCC 1:2:4, type B2 (using 40 mm graded crushed stone aggregates) as in path / paving / hard standing / floor and finished the surface even and fair without using extra cement complete all as specified and as directed. |
| 13 | M&L for PCC 1:2:4, type B1 (using 20 mm graded crushed stone aggregate) as in coping, cills, hold fasts, fixing of post, water trough, lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, etc. including necessary formwork (straight or curved) complete all as specified and as directed. |
| 14 | M&L for RCC 1:2:4, type B-1 (using 20mm graded crushed stone aggregates) as in foundations, footings, foundation beams, plinth beams, bases for columns, etc. complete all as specified and as directed. |
| 15 | M&L for RCC 1:2:4, type B-1 (using 20mm graded crushed stone aggregates) as in columns, pillars, piers, posts and struts complete all as specified and as directed. |
| 16 | M&L for RCC 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) as in Slabs supported on walls, beams, and column in floors, roof, landing, balconies, canopies, deck slab and in shelves and like etc. complete all as specified and as directed. |
| 17 | M&L for RCC 1:2:4, type B-1 (using 20mm graded crushed stone aggregates) as in Baffle walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and as directed. |
| 18 | M&L for precast RCC cover slab, 1:1.5:3 type A-1,(Using 20 mm graded crushed stone aggregate ) as in drain/manhole cover slab etc., and set in cement mortar 1:4 including necessary form work complete all as specified and as directed. |
| 19 | Use and waste Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished flat surfaces of concrete complete all as specified and as directed. |
| 20 | Use and waste formwork to sides of pillars, posts, struts, piers, columns and stanchions (Square, Circular rectangular or polygonal) for rough finished flat surfaces of concrete complete all as specified and as directed. |
| 21 | Use and waste formwork to soffits and sides of suspended slabs such as roof slabs, floor slabs, landings sun shade, chajja, floors, roofs, landings, balconies etc., n exc 200 mm thick (horizontal or sloping) for fair finished surface of concrete complete all as specified and as directed. |
| 22 | Use and waste formwork to soffits and sides of suspended slabs such as roof slabs, floor slabs, landings sun shade, chajja, floors, roofs, landings, balconies etc., n exc 200 mm thick (horizontal or sloping) for rough finished surface of concrete complete all as specified and as directed. |
| 23 | M&L for mild steel TMT bars 10 mm dia and over cut to length, bent to shape as required including cranking, bending spirally for hooping for columns,hooking ends and binding with mild steel wire(annealed) not less than 0.9mm dia as in reinforcement bar complete all as specified and as directed. |
| 24 | M&L for mild steel TMT bars 8 mm dia cut to length, bent to shape as required including cranking, bending spirally for hooping for columns,hooking ends and binding with mild steel wire(annealed) not less than 0.9mm dia as in reinforcement bar complete all as specified and as directed. |
| 25 | M&L for mild steel TMT bars 8 mm dia and over upto and including 10mm dia cut to length, bent to shape required including cutting, cranking, hooking ends and binding with mild steel wire (annealed) not less than 0.90mm dia as in stirrups, spacers and binders complete all as specified and as directed. |
| 26 | M&L for brick work with sub class ‘B’ bricks (locally available best quality) straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:4 complete all as specified and as directed. |
| 27 | M&L for brick work with sub class ‘B’ bricks (locally available best quality) straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified and as directed. |
| 28 | M&L for brick work with subclass ‘B’ bricks, (locally available best quality) straight or curved on plan to any radius in half brick thick wall, built in cement mortar (1:4) complete all as specified and directed. |
| 29 | Taking down cement plaster on walls, chajja surfaces, etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. |
| 30 | M&L for rendering 10 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 31 | M&L for 15mm thick rendering in cement mortar (1:4), in two layers, under coat of 10 mm thick & top of 5 mm thick, to other than fair faces of brick or concrete wall surfaces, top layer 5 mm thick mixed with water proofing compound @ 200Ml per bag(50Kg) of cement or as per manufacture's instructions, finished even and smooth without using extra cement complete all as specified and as directed. Note : Water proofing compound will be measured and paid separately as \\"Supply only\\". |
| 32 | Supply only liquid water proofing compound complete all as specified and as directed. |
| 33 | M&L for rendering 5 mm thick in cement mortar (1:3) as in ceiling surface finished even and smooth without using extra cement complete all as specified and as directed. |
| 34 | M&L for preparation of newly plastered surface of walls and applying two coats of oil bound distemper over a coat of primer complete all as specified and as directed. |
| 35 | M&L for preparation of newly plastered surfaces of walls and applying one coat of alkali resistant primer over a coat of 1.5 mm thick (average) white cement putty, sanding the surfaces till smooth finish is obtained and finally applying two coats of oil bound distemper complete all specified and as directed |
| 36 | M&L for preparation of newly plastered surfaces of walls and applying Two or more coats of 100% Premium exterior acrylic emulsion paint of required shade, having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all specified and as directed. |
| 37 | M&L for preparation of newly plastered surfaces of ceiling and applying two coats of white wash complete all as specified and as directed. |
| 38 | M&L for 75 mm thick PCC 1:4:8 type D2 (using 40mm graded crushed stone aggregate) as in sub base complete all as specified and directed. |
| 39 | M&L for 25mm thick PCC 1:2:4, type B0 using (12.5 mm graded crushed stone aggregate) as in floors to receive tiles complete all as specified and as directed. |
| 40 | M&L for coloured non-skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, laid in floors etc. over and including 15 mm thick screed bed in cement motar 1:4, set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles, complete all as specified and as directed. |
| 41 | M&L for glazed light coloured/printed ceramic tiles 350x250x7mm/450x350x7mm thick in vertical surfaces such as skirting dado etc set and jointed in neat cement slurry pointed in white or coloured cement to match colour of tiles, over and including 10 mm thick rendering in cement mortar 1:4 complete all as specified and as directed. |
| 42 | M&L for machine cut kota stone slab flooring 20 to 25 mm thick over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab laid over and including 15 mm thick screed in cement mortar (1:4) including rubbing and polishing complete all as specified and as directed. |
| 43 | M&L 20 mm thick Granite (of any type) tiles machine cut as in wall/pillars over 10mm thick CM (1:4) as in backing layer & jointed with grey cement slurry & pointed with white cement with admixture of pigment to match the shade of granite stone including cutting & polishing |
| 44 | Providing edge moulding to 18-20mm thick granite of any type of counters vanities etc. including machine polishing to edge to give high gloss finish etc. complete |
| 45 | S&F Powder coated (minimum thickness of powder coating 50 micron) anodised aluminium frames for door, windows, ventilators, partitions etc. with one or more rebates including joining cleat for fixing etc complete all as specified and as directed. |
| 46 | S&F Powder coated (minimum thickness of powder coating 50 micron) anodised aluminium door shutters, aluminium section weighing not less than 0.55 Kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 nos in each door, hinges, anodised aluminium snap beading screws etc. complete all as specified and as directed. |
| 47 | S&F Powder Coated for anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) for powder coating of any colour (thickness or powder coating not less than 50 micron etc. complete all as specified and as directed. |
| 48 | S&F 5.5mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and as directed. |
| 49 | S&F 3mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and as directed. |
| 50 | S&F stain-less steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed. |
| 51 | S&F factory made solid PVC door frame of size 40mm x 47mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube complete all as specified and as directed. |
| 52 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. |
| 53 | S&F 100 mm size aluminium alloy with galvanized mild steel hinge pin, anodised and fixed, type C-21 butt hinges, complete all as specified and as directed. |
| 54 | S&F 150mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed. |
| 55 | S&F 150 mm long extruded aluminium alloy handles, fabricated type anodised complete all as specified and as directed. |
| 56 | S&F Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe 290, Gde-E-165 completed all as specified and directed. |
| 57 | M&L for rolled mild steel roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc confirming to grade Fe-410-W (Gde E 250) for fixing complete all as specified and as directed. |
| 58 | M&L for preparation of new steel or iron surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paints over a coat of red oxide, zinc chrome primer complete all as specified and as directed. |
| 59 | M&L Pre- painted hot dip aluminium Zinc alloy metalic coated trapezoidal profile steel sheet 0.50mm thick ( Total coated thickness), any pattern corresponding to IS 15965 : 2012 of durability class 3, atmospheric classification category 3, coating class AZ 150 of an approved colour having yield strength of 550 Mpa as in roof covering/wall cladding, fixed with self tapping screws complete all as specified and as directed. |
| 60 | S&F 500 litres capacity rotational moulded polye-thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I with and including 20mm bore dia PTMT ball valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed etc complete all as specified and as directed. |
| 61 | S&F 20mm bore gun metal globe or gate valve cast copper alloy, screwed down, high pressure with iron wheel head screwed both ends for iron pipe complete all as specified and as directed. |
| 62 | S&F GI tubing15 mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed. |
| 63 | S&F GI tubing 20 mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed. |
| 64 | S&F CPVC pipes of 16 mm dia SDR 13.50 & Plain CPVC SDR 11 fittings in trenches, in wall and ceiling or laying in floors, including new fittings as required complete all as specified and as directed. |
| 65 | S&F CPVC pipes of 20 mm dia SDR 13.50 & Plain CPVC SDR 11 fittings in trenches, in wall and ceiling or laying in floors, including new fittings as required complete all as specified and as directed. |
| 66 | S&F bib taps 15mm dia cast copper alloy chromium plated, fancy type with crutch or butter fly handles screwed down for iron pipe or for brass ferrule complete all as specified and directed. |
| 67 | S&F stop valves/ angular stop valve, 15mm dia, cast copper alloy, fancy type, chromium plated, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or unions complete all as specified and as directe. |
| 68 | S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and as directed. |
| 69 | S&F 600 mm x 450 mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed. |
| 70 | S&F in repairs, vitreous china wash hand basin, white flat back size 550 mm x 400 mm including brackets and pillar tap, 15 mm bore chromium plated, cast copper alloy with capstan heads, 32 mm waste coupling brass chromium plated suitable for wash hand basins, with long screwed shanks and fly nuts and PVC waste pipe,15mm dia 450mm long PVC connection pipe complete all as specified and as directed. |
| 71 | S&F vitreous china wash down water closet (padestal pattern) including connection to drain (or outgoing pipe) and flushing pipe, anti syphonage pipe, trap set and including white or black seat cover for padestal pan with mild steel chromium plated aluminium hinging device, fixed to pan with suitable screws etc complete all as specified and as directed. |
| 72 | S&F vitreous China bowl, urinal flat back or corner wall type, size of 465X 355 X 265 mm white (minimum) with grating and union for discharge pipe including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60mm long brass screws, PVC connection pipe 15mm dia 450mm long, CP waste coupling 32mm (half or full thread) etc pointing around urinal back in cement etc. complete all as specified and directed. |
| 73 | S& F 110 bore PVC (SWR) pipes single socketed in any length laid in position on wall as in weep holes complete all as specified and directed. |
| 74 | S&F 110 mm dia PVC (SWR) pipes, single socketed in any length with rubber ring joints and laid in trenches or in floor/wall complete all as specified and as directed.Note : Earth work shall be measured and paid separately under respective item. |
| 75 | S&F 75 mm dia PVC (SWR) pipes, single socketed in any length with rubber ring joints and laid in trenches or in floor complete all as specified and as directed. |
| 76 | S&F 110 mm dia PVC (SWR) bends with access door any radius complete all as specified and as directed |
| 77 | S&F 75 mm dia PVC (SWR) bends with access door any radius complete all as specified and as directed |
| 78 | S&F 110mm dia PVC (SWR) junction single, (single T) equal or unequal provided with access door complete all as specifiec and as directed. |
| 79 | S&F 75mm dia PVC (SWR) junction single, (single T) equal or unequal provided with access door complete all as specifiec and as directed. |
| 80 | S&F 75 mm dia PVC(SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed. |
| 81 | S&F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement, complete all as specified and as directed. |
| 82 | S&F 75mm bore PVC (SWR) vent cowl complete all as specified and as directed. |
| 83 | M&L for extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and as directed. |
| 84 | S&F DWCPE (SN8) pipes, nominal dia 150 mm laid in trenches for sewer network, fixed and jointed with integral socket or coupler and EPDM sealing ring (depending on pipe ends) as per manufacturer complete all as specified and as directed.Make (DWCPE Pipe): Supreme, Prince, Berlia |
| 85 | M&L for concrete bed in cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) for drain pipes 150 mm bore including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed. |
| 86 | M&L for Cutting into existing manholes for connecting new drains of 150 mm internal dia of pipe, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished, and reforming benching as required complete all as specified and as directed. |
| 87 | S&F 100mm bore cast iron soil, waste and vent (spun) pipe, in any length with or without ears, with cement joints, fixed to walls complete all as specified and as directed. |
| 88 | S&F Cast iron cowl suitable for pipes of 100mm bore complete all as specified and as directed. |
| 89 | M&L for Construction of Soakage wells including excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonry in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.20 M dia X 3.00M effective depth all as specified and shown on drawing No. CE/TD/464(R) sheet 1/1.Note:- Drawing is only for reference purpose. |
| 90 | S&F mild steel angle iron post & strut etc. in fencing including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 GdeE-165 complet all as specified and as directed. |
| 91 | S&F galvanized two strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia bars at 75 mm spacing and straining and fixing to RCC / steel post etc., including securing or tying at crossing with and providing of galvanized mild steel wire, staples or steel pins, etc., (each line of wire to be measured separately) complete all as specified and as directed. |
| 92 | M&L for 610mm dia Concertina coil fencing having 15 Nos round per 6metre length, spring core 2.5mm thick wire of high tensile strength of 165kg/sqmm with tape 0.52mm thick and weight 43.478gm/meter over 'Y' angle iron post and strut laid over boundary wall complete all as specified and as directed. |
| 93 | M& L for drilling and tapping in CI/DI water mains (in position) for branch connection of the internal dia 25mm complete all as specified and as directed. |
| 94 | S&F GI tubing 25 mm bore, medium grade with all fittings and fixed complete laid in trenches/wall/floor complete all as specified and as directed. |
| 95 | S&F 25mm bore gun metal globe or gate valve cast copper alloy, screwed down, high pressure with iron wheel head screwed both ends for iron pipe complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 96 | S&F 25mm bore gun metal globe or gate valve cast copper alloy, screwed down, high pressure with iron wheel head screwed both ends for iron pipe complete all as specified and as directed. Please Enable Macros to View BoQ information |