| 1 | Supply and erection of CAT 6 with 23AWG solid bare copper conductor, special grade PE insulation with star separator, 4pair Unshielded Twisted Pair (UTP) industrial cable, FR PVC sheathed, Class-E, 250 MHz of bandwidth, supporting data transfer speeds of up to 10 Gbps (10GBASE-T) for distances up to approximately 180 feet, cables are manufactured and tested to meet the ANSI/TIA 568-C.2 and ISO/IEC 11801 Class E standards left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 2 | CAT 6 LAN cable |
| 3 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- |
| 4 | Double Walled Corrugated HDPE Pipe 63/51mm (Outer/ Inner dia.) |
| 5 | Supply, Installation , testing & commissioning ( SITC) of 4G Modem & SIM Card based Data Receiving & Sending Communication Devices working on Serial/I2C/ ModbusTCP/ EThernet TCP/IP protocols to be connected with separate City Signal Dashboard & Cloud Server System having following features and compatible for receving & sending data of Traffic Signal Controllers Systems. The device should allow for the following tasks: i. Register & Login for the Application to communicate with the existing Controller Systemsii. Location of Traffic Signal Systems iii. Sending Programs and Data to the Controller Stations iv. Live display of Power supply/Connectivity/Signal System UP or failure status v. Live Display of Traffic SIgnal Lights working with 4g time lag vi. App notification trigger to various Officials for Signal Failures indicators such as Power failure/ Signal Lights OFF (Optional) vii. Traffic Synchronisation Status, if any viii. Back-end admin panel for Maintenance Officials to pull out historical data of Signal Working fix. Fully customized Reporting module x. Switching ON/OFF Traffic SIgnals xi. Report for Special events at Traffic Signal System xi. Notification to concerned Officers and Contractors for failure of Traffic Signal Supply. Multiple alerts shall be configurable The device should be compatible with existing Traffic Signal Controllers complete in all respects as desired by the Engineer-in-charge:-at site. |
| 6 | SITC of Intelligent Motherboard Controller compatible with GSM Model and facility for connectivity to control room, Vehicle Actuation Cameras and ATCS mode for Vehicle Management with Live SKIP Timer and Camera Integration. The detailed specifications of the controller are as below: -HARDWARE Memory : NOVRAM with built in battery battery backup System clock: Calendar clock (RTC) with minimum 5 years Battery back-up clock Accuracy of Programming 1 sec per week Programming Facility Through external Engineering Application WITH BLUETOOTH operation FEATURES Number of signals Minimum 16 signals group should be programmable as either vehicular or Pedestrian groups. Additional Programmable dummy groups as desirable.Number of stage 16 stages Outputs The Motherboard should have Connector to connect further to the Sub Control Unit Vehicle Actuation: RS232/RS485/DI ports should be provided for communication with sensors and inbuilt software should be provided for Vehicle Actuation Facility so as to run the Traffic Signal in Vehicle Actuation Mode. The control system should have facility for working in Vehicle Actuation Mode. It should sense the inputs from various existing Traffic Sensors and adjust the Traffic Signals according to the intensity of traffic on all four/six roads of the Traffic Junction. The controller should be programmable so as to work in Vehicle Actuation with Cameras/Sensors etc at a particular time of the day/whole day/particular date etc. The controller should be integrated with Vehicle Detector cards, Vehicle Sensors cards etc. complete in all respects.Area Traffic control compatibility Controller should have live Ethernet/internet port for connecting to the area traffic control centre. Live port should be provided and testing / demo should be done /displayed before commissioning of controller . No hardware/software should be required to be provided up to controller at later stage when connection is required for area controller .ENVIRONMENTAL FEATURES Operating voltage:24VDC Temperature 00 C to 700 C Relative Humidity Max 95%The controller shall be installed in the pedestal and also making connections to it with all the incoming and outgoing cables as per site requirement.complete in all respectsas desired by the Engineer-in-charge:-at site. |
| 7 | SITC of Traffic Light sub control unit with facility of Output Isolation Through solid state devices with zero cross output solid state switching isolated from control circuit by optical isolation in male female plug type single module. The solid state device should not be used for switching ON/OFF of more than 2 Nos. LED Lamps including shall be installed in the pedestal and also making connections to it with all the incoming and outgoing cables as per site requirement. The Sub Control unit shall be provided with Overload/over voltage protection and modular plug-in type system shall be provided for easy maintenance. The Unit shall also be provided with Indicators for Operator use complete in all respects with continuous input voltage current control & overload. complete in all respectsas desired by the Engineer-in-charge:-at site. |
| 8 | LED SIGNAL HEAD ASSEMBLY:-SITC of IP-65 Approved One Aspect signal Head LED Light Assembly 300mm dia fabricated from polycarbonate materials die moulded Complete in all respects of nominal size 380 X 350mm complete in all respect with LED type traffic signals glasses. The visor shall be fabricated from UV Stabilised HDPE Materials of length min 254 mm depth and tilted 50 along the geometrix axis from the back side to front end as per IS 7537-1974 and the assemblies shall have provision for mounting of pole to permit directional adjustments. The lenses of red, amber or green colour shall be fabricated from 5mm dia LED’s of light intensity of minimum 5000 mcd and the electronic switching circuit wired on printed circuit board of epoxy material with transparent covering glass of polycarbonate materials. LED Viewing Angle should be 23 degree with max. Forward Current as 20 mA & lamp shall be visible from 400m under normal atmospheric conditions (Conforming to IEC60529) a) Glass with a minimum of 190 LED’s of Red/Amber colour.complete in all respectsas desired by the Engineer-in-charge:-at site. |
| 9 | Glass with a minimum of 190 LED’s of Red/Amber colour. |
| 10 | Glass with a minimum of 66 LED’s of Green colour in Arrow/Walking Man hape. |
| 11 | CANTILEVER POLE:- SITC of steel tubular pole 8.70mtr long and in two steps - bottom portion MS Pipe B class ISI mark 6mtr long 150mm dia and top portion MS pipe B class ISI mark gauge 3mtr long of 125mm dia with provision for the erection of bracket fabricated from 50mm dia M.S. pipe of A class upto 4mtr long, P type arm suitable for fixing of traffic lights and a 200mm dia round M.S. plate of 6mm thickness to be provided at the bottom of the pole. The pole will be erected 1.5mtr below ground level with 1:3:6 cement concrete mixture. The joining of the pole will be done so as to provide maximum supports to the joints including the cost of the all labour and material required for the job. The pole will also be provided with suitable reinforced plastic pole top for the safety of cables etc. The mounting arrangement of the lanterns should be made in such a way that signal heads can be adjusted as per required direction of the site complete in all respectsas desired by the Engineer-in-charge:-at site. |
| 12 | SITC of Smart Android based App for Traffic Signals to control all important parameters such as Programs, Timings, Vehicle Actuation parameters, Live Signal Working, Manual Control, Smart Icon etc shall be transferred and configurable from Smart Android APP - The following parameters shall be programmable from anywhere in Jalandhar city: - Live Simulation of Traffic Signal actual working at site - Add , edit or delete data of Programs and sets in the Controller - Check working of Cameras - Check working of Downcounters - Mains Power Status - Battery Status - 24v - battery ststaus - 12v - Logs of all important traffic data - Put Signal into manual Mode.complete in all respectsas desired by the Engineer-in-charge:-at site. |
| 13 | SITC of on PVC under ground copper conductor 1.5mm Sq mm size armoured cable suitable for A.T.C. signals 660/1100 volts conforming to ISS 1554-1998 laid in existing pipe or in trench including cost of labour material required for the job.complete in all respectsas desired by the Engineer-in-charge:-at site. |
| 14 | 14 core (loose in pipe) |
| 15 | 8 core (loose in pipe) |
| 16 | SITC of Providing Machine slit cutting 100m X100mmX 50mm Cut through manual means/ machine cut 4\\" deep with recarpeting with Tar under metal surface for road crossing & reconditioning the same after laying of pipe to complete the job as required at site complete in all respectsas desired by the Engineer-in-charge:-at site. |
| 17 | SITC of PVC copper conductor 6 core 1mmsq. wire complete in all respects including making connections complete in all respectsas desired by the Engineer-in-charge:-at site. |
| 18 | SITC of 24V 200Amp-Hr Power Pack with Sealed Maintenance free Batteries complete in all respects with connecting terminals etc. The Batteries should be mounted in existing Panels/MS Boxes and duly provided with special arrangement so as to prevent thefts.complete in all respectsas desired by the Engineer-in-charge:-at site. |
| 19 | SITC of Heavy Duty 24V cum 12V DC Rectifier of upto 20Ampere Capacity for extra charging of 24V DC 300AH Batteries complete in all respects as desired by the Engineer-in-charge:-at site. |
| 20 | SITC of Outdoor grade MS Pedestal box of approximate size 900 X 600 X 600mm (Nominal) fabricated from 1.6mm thick MS sheet and required supporting members of MS angle iron/ MS Flat duly painted & with separate compartments for batteries & Control System etc. Facility for theft proof installation of Batteries shall also be provided in the pedestal. The pedestal box should have 4 legs 70cm long of 35 x35x 5mm angles iron and grouted 30 cm below ground level in cement concrete mixture complete in all respects with provision for cable entry etc.complete in all respectsas desired by the Engineer-in-charge:-at site. |
| 21 | SITC of Industrial Grade Intelligent 1400W Battery Charger Systems provided with intelligent float charging circuit for total capacity of 300Ahbatteries @ 24V and 1 No 12V 42Ah. The system shall be provided with low/high voltage cut arrangement so as to ensure that in the event of continuous power failure, the batteries do not get deep discharged/ over charged. The charger shall be fabricated from weather resistant heavy duty Power Diodes, Switching FETs/Transistors assembled on Aluminium Heat Sink units, charging ciruicts and metering to show Voltage levels etc. The Charger should also have intgerated 12V Charging System. The system shall be housed in existing box. The cost shall include required wiring of the same. complete in all respectsas desired by the Engineer-in-charge:-at site. |
| 22 | SITC of MS Pole 100mm dia A Class ISI Mark 6.1m long duly welded for traffic signal head assemblies as requirement at site. The pole should be painted with primer red oxide and two coats of golden yellow synthetic enamel paint. The pole is to be erected 1.00m below ground level in 1:3:6 cement concrete mixture. The provision for cable entry should also be made complete in all respects with all labour and material required for the job including welding of 200 x 200 x 5mm M.S. Plate at the bottom and erection of the same in 1:3:6 cement concrete foundation. The pole top canopy fabricated from Reinforced Fiber Plastics in White Colour shall be mounted on the Top of the pole. .complete in all respectsas desired by the Engineer-in-charge:-at site. |
| 23 | SITC of Video Camera Recording & Traffic Detection System with te following minimum specifications: - Image Sensor 1/2.7″ Progressive Scan CMOS - Pixels Minimum 2.0mp - Video Compression H.264, H.265 and Motion JPEG - Video Bit rate 32 Kbps –16 Mbps - Memory 500 MB RAM - Frame Rate Support Between 20 to 30 fps - Minimum Illumination Color: 0.002Lux @ (F1.2, AGC ON), Black and white:0.0002Lux@ (F2.0, AGC ON) - Shutter Speed 1/3 s - 1/100,000 s - S/N Ratio 50 dB or better - Video Standard PAL - Lens Mount CS or C Mount - Lens Type Varifocal, C/CS Mount - Lens 3mm - 12 mm or as per site requirement - Focus Simple focus / Manual, Button control (Manual, Simple focus) - Day/Night Mode Auto (ICR) /Color / B/W Configuration - Function Vehicle Detector for counting of vehicles at each arm of the traffic junctions. The detector to be managed through web-based interface locally. The outputs of the detectors shall indicate the presence of vehicles and shall be used to influence the operation of the traffic signal controller and shall generate counts.Width of Detection 1 to 3 lanes- IR Detection (In-Built or external) - Integration The camera shall provide view of the area covered. - Enclosure External IP rated housing - Certification CE/FCC/BIS complete in all respectsas desired by the Engineer-in-charge:-at site. |
| 24 | SITC of 12 Port siwtch for communication of Controller, Internet, Timers and Cameras including cost of programming at site and setup charges complete in all respects as desired by the Engineer-in-charge:-at site. |
| 25 | SITC of Live Signal receiving Multi-Media Messaging Displays with SKIP Functionality and in-built Timer display for showing Traffic Light Remaining Time. The display shall have 3 sections- 1. Timer Display part - Two Colour Microprocessor based Down Counter Timer for computerized ATC Signals to display the timings of Red, Straight Green or Side Green timings independently (as per requirement) in respective Red or Green colour. The down counters should have 2½ digits with a capability of counting down of Red/ green times duly synchronized with multi programmable microprocessor controller. The system should function in 3 modes- 1) Time reading Mode- the Timer should itself note the change in programmable timings of the controller and it should adjust to changed Red/ Green timings in the next cycle with GO & STOP Messages. The display of amber cycle should be optional. 2) SKIP Mode- In this mode, the timer should adjust times as per Sensor Data received from the controller and reduce the times instantly on all roads.3) ATCS Mode- the Timer shall receive live inputs from the Controller via LAN Cables and display the time accordingly. The job also includes the cost of calibration of the system including the cost of material and labour existing Lamp/ sub control unit/LAN to the down counter with PVC sheathed Copper wire. The second part shall be able to display various Images as desired by Department.The image can be full colour or single colour as per requirement of Police.Bottom Part shall be message area where Important City Traffic or Emergency messages can be shown.The display specifications can be as follows:*The display shall weather-poof, and excellent capability of antisepsis, waterproof.• Display Size – 384mm X 768mm X 100mm• No. of LED Pixels in Frame- 128 X 256• LED pitch- 6mm• Brightness- 5000mCd• LED Config- 1R, 1G, 1B in 1 SMD• Modular Construction ensures easy carrying and assembling.• Power Supply Bank of min Capacity 20 Amperes @ 5V.• Screen Border fabricated from Mild Steel• Body Thickness- 1.5mm CR• Clamping & Mounting System- Compatible with existing Site Structures complete in all respectsas desired by the Engineer-in-charge:-at site. Please Enable Macros to View BoQ information |