| 1 | Supply of 11KV lines |
| 2 | Supply of 110 mm dia. HDPE pipe by Manual/molling method as per site condition, for underground piping |
| 3 | Supply of G.I. pipe 4\\" dia with height of 3 meter with clamps, Nut and Bolts for hoisting of cable. |
| 4 | Supply of MS Angle 25x25x3 sq mm |
| 5 | Supply of 50x5 MS Strip |
| 6 | Supply of DTR and LT U.G Line |
| 7 | Supply of Out Door Type Feeder Piller Panel to be made of 2 mm CRCA Sheet & covered will be 1.6 mm CRCA Sheet Duly Pouder coated paint with 400 Amp Allu. busbar. Incomer - 250 Amp, TPN MCCB - 01 NoOutgoing - 100 AMP TPN MCCB - 05 NoThe cubicle shoud be weather proof |
| 8 | Supply & Erection of 3-ph 415 V , Distribution Service Piller for LT. 125 Amp Incoming 4 nos 32 Amp, TPN 12 Nos 32 Amp SPN.Rating Feeder Type Distribution Service Piller suitable for Outdoor Installation. |
| 9 | Supply of Outdoor type LT Distribution Board with a Rupturing capacity of 50 KA at 415 V or As called for individual Items ( CPRI Approved Manufacturer) Openable in frant and back suitable for 3 Phase 4 wire 50Hz AC Supply and an Ambient temp. of 45 Deg.C. The cubical should be weather proof and enclosure protection shall be IP-55 As per IS 2147-1962 and IS 8623. The Panel / Switches board shall be fabricated out of 14 SWG CRCA Sheet Steel & Provided with 16-S WG Hinged Doors in main LT Pannel at S/s.Incommer - 01 No 1250 Amp, TPN ACB with inbuilt MPR Release with on / Off indiacating lights Metering on incommer - 01 Set off Digital Meter with ASS01 Set of Digitel Volt Meter with VSS01 Set of LED Type Phase Indecating Lights With control MCBsOutgoing - 4 Set of 400 Amp TPN MCCB with Spreader & estended handle 02 Set of 250 Amp TPN MCCB & 02 Set of 100 AMP TPN MCCB with Spreader & estended handle |
| 10 | Supply of Outdoor type LT Distribution Board with a Rupturing capacity of 50 KA at 415 V or As called for individual Items ( CPRI Approved Manufacturer) Openable in frant and back suitable for 3 Phase 4 wire 50Hz AC Supply and an Ambient temp. of 45 Deg.C. The cubical should be weather proof and enclosure protection shall be IP-55 As per IS 2147-1962 and IS 8623. The Panel / Switches board shall be fabricated out of 14 SWG CRCA Sheet Steel & Provided with 16-S WG Hinged Doors in main LT Pannel at S/s.Incommer - 01 No 800 Amp, TPN ACB with inbuilt MPR Release with on / Off indiacating lights Metering on incommer - 01 Set off Digital Meter with ASS01 Set of Digitel Volt Meter with VSS01 Set of LED Type Phase Indecating Lights With control MCBsOutgoing - 4 Set of 250 Amp TPN MCCB with Spreader & estended handle & 02 Set of 100 AMP TPN MCCB with Spreader & estended handle |
| 11 | Supply of WPC Board |
| 12 | Supply of 3 ½ Core ,240 sqmm. Armoured Al conductor XLPE insulated 1.1 kV grade armoured Power cable as per Technical specification |
| 13 | 3 ½ Core ,150 sqmm. Armoured Al conductor XLPE insulated 1.1 kV grade armoured Power cable as per Technical specification. |
| 14 | Supply of 3 ½ Core ,25 sqmm. Armoured Al conductor XLPE |
| 15 | Supply of HDPE Pipe 50 mm Suitable for 3.5 C x 25 sqmm Cable Manual Method. |
| 16 | Supply of Single Phase two wire Cu. LT armoured PVC cable (2x4 Sq.mm.) incl. Clamp & Assessories with laying & Restoration |
| 17 | Supply of Three Phase Four wire Cu. LT armoured cable (4x10 Sq.mm.) incl. Clamp & Assessories with laying & Restoration |
| 18 | Shifting of 11KV lines |
| 19 | Laying of 11 kV XLPE insulated armoured Al. cable of size 3Cx185 sq.mm in RCC Pakka Tranch by supporting of cable tray properly as per norms |
| 20 | Erection of Heat Shrinkable Jointing Kit Outdoor for 11 KV 3x185 sq. mm XLPE Cable make rycheme/3M |
| 21 | Erection of Heat Shrinkable Jointing Kit Straight through for 11 KV 3x185 sq. mm XLPE Cable make rycheme/3M |
| 22 | Laying of 110 mm dia HDPE Pipe by HDD/Manual Methode for laying of 11 kv cable |
| 23 | Laying of 11 KV XLPE cable in Already laid HDPE Pipe |
| 24 | Digging of pit1200 mm from ground level for Laying of LT cable by Providing of Brick on both side of HDPE Pipe and trench covered with stone slab after filling sand into the trench/ molling method by providing of HDPE Pipe |
| 25 | Laying of 11 KV 3Cx185/300 sq.mm XLPE Cable underground through HDPE Pipe at 950 mm below the ground surface. (by HDD method) |
| 26 | Laying of G.I. pipe 4\\" dia with height of 3 meter with clamps, Nut and Bolts for hoisting of cable. |
| 27 | Errrection of 11Mtr STP for making Double pole structure complete |
| 28 | Hoisting of 11 kv 3x185 sq mm XLPE cable with support of G.I Pipe & jumpring complete |
| 29 | Erection of Earthing of pole by MS earthing rod of 20x2500 mm. and 6 SWG earthing wire etc. |
| 30 | Errection of MS Angle 25x25x3 sq mm & 50x5 MS Strip for making cable tray with support of angle as per design for laying of 11 kv cable |
| 31 | Supply and errection of Chemical pipe earthing for Cable J/Kit including cost of GI earth strip of size 25x5mm and connection as rerquired. |
| 32 | Shifting of DTR and LT U.G Line |
| 33 | Erection of Out Door Type Feeder Piller Panel to be made of 2 mm CRCA Sheet & covered will be 1.6 mm CRCA Sheet Duly Pouder coated paint with 400 Amp Allu. busbar. Incomer - 250 Amp, TPN MCCB - 01 NoOutgoing - 100 AMP TPN MCCB - 05 NoThe cubicle shoud be weather proof |
| 34 | Erection of 3-ph 415 V , Distribution Service Piller for LT. 125 Amp Incoming 4 nos 32 Amp, TPN 12 Nos 32 Amp SPN.Rating Feeder Type Distribution Service Piller suitable for Outdoor Installation. |
| 35 | Erection of LT DB on RCC Structure as per drawing |
| 36 | Supply & Erection of Al. crimping lugs 400 sq.mm. |
| 37 | Supply & Erection of Al. crimping lugs 240 sq.mm. |
| 38 | Erection of WPC Board fencing all around DT and RMU/Sectionaliser including cost of material as per specification. |
| 39 | Laying of 3 ½ Core ,240 sqmm. Armoured Al conductor XLPE insulated 1.1 kV grade armoured Power cable in Pakka cable tranch on cable tray |
| 40 | Laying of 3 ½ Core ,150 sqmm. Armoured Al conductor XLPE insulated 1.1 kV grade armoured Power cable in Pakka cable tranch on cable tray |
| 41 | Supply & laying of HDPE Pipe 110 mm Suitable for 3.5 C x 95/150 sqmm Cable Manual Method. |
| 42 | Supply & laying of HDPE Pipe 160 mm Suitable for 3.5 C x 240 sqmm Cable Manual Method. |
| 43 | Laying of 110 mm dia HDPE Pipe by HDD/Manual Methode for laying of LT cable off size 3 ½ Core ,150 sqmm |
| 44 | Laying of 160 mm dia HDPE Pipe by HDD/Manual Methode for laying of LT cable off size 3 ½ Core ,240 sqmm |
| 45 | Laying of 3 ½ Core ,25 sqmm. Armoured Al conductor XLPE insulated 1.1 kV grade armoured Power cable as per Technical specification. |
| 46 | Laying of 50 mm dia HDPE Pipe by HDD/Manual Methode for laying of LT cable off size 3 ½ Core ,25 sqmm |
| 47 | Supply & Erection of Cable gland of suitable size along with all accessories |
| 48 | Supply & Erection of Chemical earthing of Outdoor type LT Disribution Boards (A-type)and Distribution feeder pillar Box ( B Type)(80 mm dia,3 M long) using GI Strip |
| 49 | Sundries |
| 50 | Supply & erection Foundation & Support Structure of Distribution Service Piller Box with grouting |
| 51 | Erection of Earthing of Distribution Service Piller Box by MS earthing rod of 20x2500 mm. and 6 SWG GI wire etc. together with fixing arrangement as per TS. (C-Type) |
| 52 | Shifting and connection of single phase meter on the boundary wall outside the premises with all connections |
| 53 | Shifting and connection of three phase meter on the boundary wall outside the premises with all connections |
| 54 | Laying of Single Phase two wire Cu. LT armoured PVC cable (2x4 Sq.mm.) incl. Clamp & Assessories with laying & Restoration |
| 55 | Laying of Three Phase Four wire Cu. LT armoured cable (4x10 Sq.mm.) incl. Clamp & Assessories with laying & Restoration |
| 56 | Supply PVC pipe Heavy Gauge 25 mm dia. Inc all necessaory Assesories for LT 1-ph & 3-ph Cosumers with laying in trench ater digging of road for S/Cthen Restoration |
| 57 | Dismantling of Old Existing line |
| 58 | Carriage of dismentalled Pole/Conductor/all other material upto utility Store as per site condition. Please Enable Macros to View BoQ information |