| 1 | Sub Head-I (Wiring & ITC of fan & Fittings) |
| 2 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 3 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 4 | Wiring for circuit/ sub main wiring along with 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 5 | Wiring for circuit/ sub main wiring along with 4 X 1.5 sq. mm + 2 X 1.5 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 6 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 7 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in surface/recess etc. as required. (Make: Legrand /Havells/Anchor/Schneider) |
| 8 | 8 Module (125mmX125mm) |
| 9 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 10 | 5/6 A switch |
| 11 | 3 pin 5/6 A socket outlet |
| 12 | Supplying and fixing 5 stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. (2M) |
| 13 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 14 | Supplying and fixing following rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make: Legrand/Siemens/ L & T) |
| 15 | 6-32Amps Single pole |
| 16 | Supply and Fixing of MCB protected Socket outlet 3 modules with metal box comprising of 01no. 25Amps socket and 01no. 25Amps Plug and 01no. 25Amps \\"C\\" series SPMCB for Split AC units’ i/c grouting in wall, connection, testing etc. as required. |
| 17 | Replacement of faulty and damaged ceiling fan by new one of following size of Havells /Usha / Crompton/SS Make suitable for operation on 240 volts AC, 50Hz i/c fixing and connection etc. as required. |
| 18 | a) 300 mm sweep wall mounting fan |
| 19 | Sub Head-II (Dismantling & Shifting of AC units) |
| 20 | Dismantling of the existing faulty faulty DOL Starter of the 3 HP Centrifugal pump motor set i/c shifting the same to workshop for repairing i/c replacement of the damaged relay, sockets etc and refixing the same i/c testing, commissioning etc complete as required. |
| 21 | Dismantling of split AC units unit with all assessories and associated items etc complete as required |
| 22 | Closing the existing wall openings of the old WAC units properly i/c supplying of required materials i.e 35 mm x 5 mm MS angle, 12 mm square bar, fiber glass etc. i/c cutting welding etc complete as required. |
| 23 | Closing the wall openings for Window AC units by cement bricks i/c plastering etc. complete as required. |
| 24 | Installation , testing , & commissioning of 1.5 TR Split A.C. Unit , mounting / Fixing of indoor & outdoor unit ,fixing of refrigerant piping with expanded polythene foam insulation, laying of cable for interconnections and laying drain pipe of standard length which is supply along with AC unit, minor civil work i/c making holes on wall for laying refrigerant pipe lines, control cable and drain pipes and closing the extra openings with cement sand, making good the damages etc. as reqd. |
| 25 | Providing and fixing of suitable size L- shaped powder coated MS bracket (2 nos. per set ) for fixing of the outdoor unit of the split A/C units and fixing on wall with anchor bolts, drilling holes etc. complete as reqd. |
| 26 | Providing and laying of additional drain pipe of size 20mm dia PVC braided/ solid (M class-ISI) along with all accessories and fixing on surface of wall with PVC saddles (if required) suitable for drainage of condensate water etc. as reqd. |
| 27 | Dismantling of unsued Electrical appliances like Main LT panels, electrica |
| 28 | Shifting of above items from Door Sanchar Bhawan Link Road, Cuttack to BSNL Electrical Division Ofiice at Cantonment Road, Cuttack i/c loading/unloading etc complete as required. Please Enable Macros to View BoQ information |