| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE NAMS Name of Work : REPAIR/ FITTINGS/ FIXMENTS/ MAINT AND REPLACEMENT OF INTERNAL ELECTIRCAL, DISTRIBUTION BOARD INCLUDING WIRING IN OFFR'S MESS, JCO'S MESS/ OR'S MESS & CENTRAL INSTITUTE Contract No: GE NAMS-04/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. TEXT # Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT With Taxes TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Taking down aluminium/unsv copper point wiring from existing conduit / batten (light, fan, socket or power) complete such as switches, ceiling rose, pendent, regulators, socket, light fittings etc and removing material from site and making good the disturbed surface of wall / floor etc, complete all as specified and directed |
| 3 | M&L for point wiring with 1.5 sqmm (Nominal area ) 1100 Volt PVC Insulated , FRLS unsheathed and multi stranded copper conductor cable in and PVC Concealed conduit 20mm dia 1.5mm thick for one light / fan point or bell point controlled by one switch (including cutting chases and making good the distributed surfaces) and fixing new 3mm thick hylem sheet top cover, sheet screws and sunken boxes after removing old unserviceable plastic laminated sheeet and sunken boxes included 1.5 Sqmm stranded copper conductor with green PVC Insulation earth contunity conductor connected to common earth dolly etc complete all as specified and directed for the following :- (a) for one light /fan/ buzzer point controlled by one 5 Amp switch one wayNote : (i) The cost of sunken boxes and bakellite sheet is included in the quoted rate. (ii) On RCC roof ceiling PVC conduit shall be provided on surfaces for any necessary point with proper fixing clips and no extra cost shall be paid for the job etc. |
| 4 | All as per ser item No 2.00 above here-in-above but one light /fan/ buzzer point controlled by one 5 Amp two way switch complete all as specified and directed. |
| 5 | All as per ser item No 2.00 above here-in-above but one three pin socket outlet 5 Amps independent board complete all as specified and directed. |
| 6 | All as per ser item No 2.00 above here-in-above but one three pin 5 Amps socket outlet on the same board with other switches complete all as specified and directed. |
| 7 | All as per ser item No 2.00 above here-in-above but with 2.5 Sq mm size cable multi stranded FRLS copper wire unsheathed for one 3 pin socket outlet 15 Amps on independent board including continuous earth wire of PVC insulated 2.5 Sq mm copper standed conductor connecting to common earth dolly complete all as specified and directed. |
| 8 | Supply and Fixing switch piano type 6 Amps one way 230 volts AC complete all as specified and as directed. |
| 9 | Supply and Fixing socket outlet 5 pin, 6 Amps flush type 230 volts AC complete all as specified and as directed. |
| 10 | Supply and Fixing switch piano 16 Amps type one way 230 volts AC complete all as specified and as directed. |
| 11 | Supply and Fixing socket outlet 5 pin 6/16 Amps multi purpose flush type 230 volts AC complete all as specified and as directed. |
| 12 | Supply and Fixing switch piano 6 Amps type two way 230 volts AC complete all as specified and as directed. |
| 13 | Supply and fixing ceiling rose 65X50 mm two to three terminals complete all as specified & directed. |
| 14 | Material and labour of lamp holder insulated body with 9 Watt LED Bulb, back plate batten/angle type for batten fitting fixed on bakelite sheet 100mmx100mm 230V AC, cool day light 6500K complete all as specified and directed. |
| 15 | Supply and fixing of fan regulator, electronic step type heavy duty socket type 230 volts complete all as specified and as directed. |
| 16 | S&F in replacement MCBs single pole (SP) 40 Amp with 10 KA breaking capacity of 'B' series in distribution boards complete all as specified and as directed. |
| 17 | S&F in replacement MCBs single pole (SP) 6 to 32 Amps with 10 KA breaking capacity of 'B' series in distribution boards complete all as specified and as directed. |
| 18 | S&F in replacement MCBs single pole and neutral (SPN) 40 to 63 Amps with 10 KA breaking capacity of 'C' series in distribution boards complete all as specified and directed. |
| 19 | Supply & fixing in replacement of single pole and neutral sheet metal enclosures with two pin & earth plug and socket complete with one single pole MCB of 20 Amps complete all as specified and as directed. |
| 20 | Supply and fixing in replacement of sheet metal enlosure for DBs when MCBs to be used double door factory made flush fixed complete with 100 amps rated bus-bar 240 volts single phase 8 ways including necessary brick work and plaster to match with the existing surface complete all as specified and directed. |
| 21 | Supply and fixing in replacement of sheet metal enlosure for DBs when MCBs to be used double door factory made flush fixed complete with 100 amps rated bus-bar 240 volts single phase 12 ways including necessary brick work and plaster to match with the existing surface complete all as specified and directed. |
| 22 | Supply and fixing in replacement of MCCB 100 Amps , AC 415 Volts 16KA 4 pole,ics=75% icu with spreader terminal including making connections with suitable size lugs complete all as specified and directed. |
| 23 | Supply and fixing in replacement of sheet steel enclouser distribution boards, double door factory made TPN Vertical 4 way 3 phase 415 volts 4 way with 200 amps rating copper bus bar and PVC insulated copper jumpers of suitable size from the MCCB to the out going circuits one incoming MCCB and 12 outgoing MCBs circuits comprising of 3 phase 4 wire of suitable rating complete all as specified and directed with the following accessories :- (a) MCCB 100 amps, 16 KA, ics=75% icu, with spreader terminal, FP, 415 volts, 50 Hz = 01 No. (Note: Out going MCB shall be measured and paid for separately). |
| 24 | S&F in repairs Sub Main Wiring two single core PVC insulated cable of size 6.0 Sqmm multistranded copper conductor two run drawing into and including concealed rigid non-metallic PVC conduit, medium grade not less than 25mm dia with all conduit fitting,fixing accessories and one run of 6.0 Sqmm multistrand copper conductor cable as continuous earth wire complete all as specified and directed.Note :-Two Nos of 6.0 Sqmm Wire and one No of 6.0 Sqmm Earth wire in One RM length Measured as one unit length. |
| 25 | S&F in repairs Sub Main Wiring two single core PVC insulated cable of size 4.0 Sqmm multistranded copper conductor two run drawing into and including concealed rigid non-metallic PVC conduit, medium grade not less than 25mm dia with all conduit fitting,fixing accessories and one run of 4.0 Sqmm multistrand copper conductor cable as continuous earth wire complete all as specified and directed.Note : Two Nos of 4.0 Sqmm Wire and one No of 4.0 Sqmm Earth wire in One RM length Measured as one unit length. |
| 26 | Supply and fixing LED mirror light fitting with high out put diffuser 2 feet, 10 watt 220 V AC pf > 0.95 decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 27 | Supply and fixing in replacement of LED T-8 tube light fitting with single side connection polycarbonate LED tube rod 18/20W 4 feet with CRCA box Suitable box complete including rotary type bipin holder and connection with PVC insulalted twin core 23/0.0076 twisted copper cable from ceiling rose to tube light fitting complete all as specified and directed. Note:- led box and led channel should be of same make. |
| 28 | Supply & fixing of AMAZE Square shaped recess mounted down lighter ,12 Watt including separate replaceable electronic driver celling cut out as per existing shape/size polycarbonate fixture complete all as specified and directed. |
| 29 | Supply & fixing of AMAZE Square/Round recess mounted down lighter , 18 Watt including separate replaceable electronic driver celling cut out as per existing shape/size square shaped polycarbonate fixture complete all as specified and directed. |
| 30 | Supply & fixing of AMAZE Square/Round recess mounted down lighter, 15 Watt including separate replaceable electronic driver celling cut out dia as per existing shape/size round shaped polycarbonate fixture complete all as specified and directed. |
| 31 | Supply & fixing in replacement of Garden light/ Post Top lantern with provision of LED bulb holder type 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact with corrosion resistant complete with driver and 9 Watt LED lamp complete all as specified and directed |
| 32 | Supply and fixing in replacement of security light fitting LED 35 Watt with dusk and dawn sensor aluminium pressure dia cast housing with touched glass cover IP-66 protection including suitable size GI Bracket and accessories complete mounted including connection with 3 core PVC insulated overall sheathed flexible cable with multi-stranded copper conductor of size not less than 1.0 Sqmm from ceiling rose to fitting terminal including taking down old CFL security light fitting all as specified and as directed. |
| 33 | Supplying and fixing LED bulk head light fittings 10watt white including LED strip as per IP65 in enginnering plastic housing with clear prismatic diffuser and making necessary connections complete all as specified and directed. |
| 34 | Supply and fixing in replacemnt LED tube Rod 18/20W, 1.2 mtr length output 6000 to 6500 lumens 220V AC white effect complete all as specified and directed. |
| 35 | Supply and fixing PVC Exhaust fan AC 230Volts 200/250mm ventilator DX high quality engineering plastic complete with louvers and shutters complete all as specified and directed . |
| 36 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 37 | Supply and fixing in replacement bracket made out of GI pipe suitable size for mounting building security light of medium grade 1.2 mtr long made to shape with fixing clamps of MS flat 40x6mm nut bolts etc for street light complete all as specified and directed. |
| 38 | Taking out existing unserviceable switch board plates any type, dismantling switches carefully, stacking at site for use of serviceable switches and supply and fixing new 3mm thick masonite laminated sheet top cover fixed on 9 inch x 11 inch or nearest size as per site requirement MS box with brass screw for mounting switches, sockets, regulator etc including making necessary electrical connection with 1.5 sqmm single core copper multistranded cable complete all as specified and directed.(Note : New Switches, sockets, fan regulators etc if required will be measured and paid separately under relevant items). |
| 39 | Taking out existing unserviceable switch board plates any type, dismantling switches carefully, stacking at site for use of serviceable switches and supply and fixing new 3mm thick masonite laminated sheet top cover fixed on 5 inch x 8 inch or nearest size as per site requirement MS box with brass screw for mounting switches, sockets, regulator etc including making necessary electrical connection with 1.5 sqmm single core copper multistranded cable complete all as specified and directed.Note : New Switches, sockets, fan regulators etc if required will be measured and paid separately under relevant items. |
| 40 | Supply and Install in replacement of Off Load Change over switch 415 Volts in sheet metal enclousure 4 Pole of capacity minimum 100 Amps complete all as specified and directed. |
| 41 | Supply and fixing in replacement of 40mm dia tube light grade galvanised with all fittings complete to wall or for garden lights or laid in floors for cable protection including cutting chases and necessary brick work and plaster work to making good the distributed surface complete all as specified and directed. |
| 42 | M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade) and watering pipe 20 mm bore GI pipe (light grade ) and chamber of pcc 1:4:8 type D2 using 40 mm graded stone aggregate and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PART 1 , with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switche, DBs) complete all as specified & testing on completion. |
| 43 | Supply & Fixing in replacement Batten Series, LED luminaire using LEDs 20 watt with 'Eye Soft' technology & glarefree diffuser for perfect application , Energy efficient, Flicker free start Inbuilt driver unit Suitable for wall and ceiling mounting using brackets complete all as specified and directed. |
| 44 | M&L in replacement of single core wiring 6 Sqmm multi-strand PVC insulated copper conductor FRLS cable including connections of cable with MCBs or bus bars complete all as specified and directed. |
| 45 | M& labour for aluminium service wire 10 sqmm 2 core pvc insulated and pvc sheathed 1100 volts grade complete all as specified and directed |
| 46 | M& labour for aluminium service wire 16 sqmm 2 core pvc insulated and pvc sheathed 1100 volts grade complete all as specified and directed. |
| 47 | Supply and fixing modular fan regulator,120 W, two module, electronic step type heavy duty socket type 230 volts complete all as specified and as directed. |
| 48 | Supply and Fixing Modular switch 6 /10 Amps one module 230 volts AC complete all as specified and as directed. |
| 49 | Supply and Fixing Modular socket, 6A 2/3 pin combined 2 module, 230 volts AC complete all as specified and as directed . |
| 50 | Supply and Fixing Modular switch 16 Amps one module 230 volts AC complete all as specified and as directed. |
| 51 | Supply and Fixing Modular socket 6A/16A, 2/3 pin combined, two module 230 volts AC complete all as specified and as directed |
| 52 | Supply and fixing in replacement of driver 25 watt to 36 Watt as per requirement at site for building security light/2'x2' recessed type Panel light complete all as specified and as directed. |
| 53 | Supply and fixing in replacement of driver 6 watt to 18 Watt as per requirement at site for recessed type light complete all as specified and as directed. |
| 54 | Supply and Laying in replacement in trenches or passing through pipe or fixing to pole/wall UG cable XLPE, of cross section area 35 sqmm 3.5 core, PVC insulated,armoured heavy duty electric cable with aluminum conductor, 1100 Volts grade complete all as specified and directed.Note : Earth work/ sand cushioning shall be measured and paid separately . |
| 55 | Excavation in trenches in soft/loose soil n.exc. 1.5mtr wide and n. exc. 1.5mtr in depth and getting out for laying of cables complete all as specified and directed |
| 56 | Removing excavated material n. exc. 50m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed. |
| 57 | Returning, filling in, and including spreading, levelling,watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed. |
| 58 | Supply,laying & fixing in replacement double wall corrugated (DWC) pipes made of high density polythyline (HDPE) with all accessories i.e. all type of joints, Sockets, Elbows, bends and End caps of size 63 mm outer dia and 50 mm inner dia etc. complete all as specified and directed. |
| 59 | Labour for drilling hole under the road with the help of drilling machine without damaging the road horizonally for rod crossing for cable protection complete all as specified and directed Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |