| 1 | Excavation over areas, n exc 1.5 m deep and getting out in hard / dense soil complete all as specified and directed. |
| 2 | Excavation over areas, exc 1.5 m and not exc 3.0 m deep and getting out in hard / dense soil complete all as specified and directed. |
| 3 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 4 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. |
| 5 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 6 | Demolition of brickwork or stone/boulder masonary, built in cement mortar including all plain concrete cement, coping, quoins, arches, pillars, etc including removal of rubbish/ demolished materials out of MD land complete all as specified and directed. |
| 7 | M & L PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in foundations filling and mass concrete complete all as specified and directed. |
| 8 | M&L Brick work with sub class `B' bricks straight or curved on plan exc 6.0m mean radius built in CM (1:6) complete all as specified and directed. |
| 9 | M & L Brickwork with sub class ‘B’ bricks in one brick thick honey comb walling, built in CM (1:3) complete all as specified and directed . |
| 10 | M&L RCC M-25 Design mix (using 20mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed |
| 11 | M&L RCC M-25 Design mix (using 20mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span upto a height of 8.00m from ground level complete all as specified and directed |
| 12 | M&L RCC M-25 Design mix (using 20mm graded stone aggregate) as in columns upto a height of 8.00 m from ground level complete all as specified and directed |
| 13 | M&L RCC M-25 Design mix (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floor, roofs, landings, balconies, canopies, deck slabs and in shelves and the like upto a height of 8.00 m from ground levelcomplete all as specified and directed |
| 14 | M&L RCC M-25 Design mix (using 20mm gradedstone aggregate) as in chajjas supported on walls, beams and columns in floor, roofs, landings, balconies, canopies, deck slabs upto a height of 8.00m from ground level complete all as specified and directed |
| 15 | M&L TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips,complete all as specified and directed. |
| 16 | All as per Item No.15 above,but 5mm dia and over upto and including 10mm dia as in stirrups , spacers and binders etc. |
| 17 | Use and waste of Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter finished rough surfaces complete all as specified and directed. |
| 18 | Use and waste of Formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surfaces complete all as specified and directed. |
| 19 | Use and waste of Form work to sides and soffits of floor or roof beams, beam haunching, lintel etc rough finished surfaces of concrete flat surfaces complete all as specified and directed. |
| 20 | Use and waste of Form work to soffits and sides of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for rough finished surfaces of concrete complete all as specified and directed. |
| 21 | M & L Dholpur stone with hammer dressed facework (with maximum depression from a straight edge held against the dressed surface not exc 20mm), size as approved by GE about 40mm high, 75mm deep in straight courses, laid and jointed in cement and stone dust mortar 1:3, recess pointed (10mm x 20mm) with an admixture of white cement and Dholpur stone dust 1:1 or with approved apoxy as in horizontal and vertical surfaces etc. upto a height of 8 mtr from GL to match over & incl 10mm thick rendering in CM (1:4) complete all as specified and as directed. |
| 22 | M&L Glazed ceramic coloured tiles of size 350x250x7 mm/ 450 x 350x 7mm thick as in vertical surfaces, such as skirting or dado,etc. set and jointed in neat cement slurry/paste and pointed to match the surfaces over and including 10 mm thick CM (1:4) rendering as backing coat complete all as specified and as directed. |
| 23 | M&L Decorative Mangalore tiles, white house roof design style of red colour of any size as directed and approved by GE and including fixed with necessary adhesive complete all as specified and directed. |
| 24 | M&L Decorative Mangalore ridge tiles,white house roof design style of red colour of any size as directed and approved by GE and including fixed with necessary adhesive complete all as specified and directed. |
| 25 | M&L 150 mm thick PCC (1:2:4) mix, type B2 (using 40 mm graded stone aggregates) as in subbase to floor complete all as specified and as directed. |
| 26 | M&L 100 mm thick PCC (1:4:8) type D-2, (using 40 mm graded stone aggregates) as in subbase to floor complete all as specified and as directed. |
| 27 | M& L 100 mm X 100 mm X 100 mm kabul Stone (granite) machine cut at all sides and laying as per approved pattern. etc, bedded in cement mortar (1:3), joints 20mm thick; grouted in cement mortar (1:2) with an admixture of metallic floor hardner 5% by weight of cement complete all as specified and as directed. |
| 28 | M&L Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and as directed. |
| 29 | M&L Rendering 15 mm thick CM (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed |
| 30 | M&L Rendering 5 mm thick CM (1:3) on fair faces of ceilings finished even and smooth without using extra cement complete all as specified and as directed |
| 31 | M&L Rendering 15 mm thick CM (1:4) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed |
| 32 | M & L Preparing newly plasterd surfaces of ceillings and applying two coats of Acrylic distemper over and including a coat of primer over and including 3 mm thick wall care putty complete all as specified and as directed. |
| 33 | M & L Preparing newly plasterd wall surfaces of walls and applying two coats of Acrylic distemper over and including a coat of primer over and including 3 mm thick wall care putty complete all as specified and as directed. |
| 34 | M&L Preparation of new plastered wall surfaces and aplying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over and including 3mm thick wall care putty complete all as specified and as directed. |
| 35 | S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc, complete, drilled for fixing of steel sheeting or other covering, doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging fittings and conforming to Fe 410-W (Gde E-250) quality ‘B’ including dismantling existing complete all as specified and as directed. |
| 36 | S&F Decorative knobs for gates any size, etc., complete all as specified and as directed. |
| 37 | M&L Preparing the new steel or iron surfaces of any description over 10 centimetre width or girth and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer complete all as specified and as directed |
| 38 | M&L Providing concealed point wiring of any length complete with stranded copper conductor cables in PVC conduit 1.5 Sqmm (nominal area) PVC insulated unsheathed cable up to 1100 V grade FRLSH conforming to IS - 694 multistranded drawn including conduit with new sunk type pressed steel terminal boxes suitable for MODULAR switches including fixing/grouting sunken/ surface as per site requirement covered with suitable modular white cover plate for suitable size for mounting of MODULAR switches, regulators and drawing continuous earth wire with one run of 1.5 Sqmm (nominal area) PVC insulated unsheathed cable up to 1100 V grade FRLSH conforming to IS - 694 multistranded copper conductor as earth wire and connecting to common earth dolly for one light point controlled by one, one way switch 5 amps, SP and making good the disturbed wall surfaces to match with the existing surfaces complete all as specified and as directed for the following :- Note: Modular cover plate with frame and modular metal flux box included in the rate quoted. |
| 39 | All as per Item No.38 above,but one 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board . |
| 40 | All as per Item No.38 above,but one 3 point 5 Amps switch socket outlet point controlled by one switch on the same board. |
| 41 | All as per Item No.38 above,but using 2.5 Sqmm single core FRLSH copper conductor cable of multistranded PVC insulated unsheathed 1100 Volts grade for 3 Pin 15 Amps switch socket combination point on independent board including running of 2.5 Sq mm FRLSH copper conductor PVC insulated cable as earth continuity conductor. Note: Cutting/chases will me measured and paid seperately. |
| 42 | S&F MODULAR switch 1 way 6 A, 1 Module capacity 230 volts complete all as specified and as directed. |
| 43 | S&F MODULAR socket 5 pin 6 amps 2 MODULE, 230 Volts complete all as specified and directed. |
| 44 | S&F MODULAR socket 6 pin 6/16 amps 2 MODULE, 230 Volts complete all as specified and as directed. |
| 45 | S&F Switch MODULAR 1 WAY 16 amps, 230 Volts complete all as specified and as directed. |
| 46 | S&F LED downlighter surface mounted light ABS body (round) 18 watts, 6500K complte with all accessories all as specified and directed. |
| 47 | S&F Energy saving, aesthetically designed, recessed mounted LED spot Light 30W , 3000K, down light pressure die-cast alluminium heat sink & high efficiency long life COB LED mounted on MCPCB with gigh efficiency aof 140 Lm/W used for enhanced lumen output with all accessories complete all as specified and directed. |
| 48 | S&F Sheet metal enclosure vertical type MCCB DB TPN 4 way double door with suitable rated bus bar 415 volts suitable for and including MCCB TPN as incomer with suitable rated copper bus bar with neutral link including provision for 100 Amps MCCB 25KA TPN as incomer and SP/TP MCBs as outgoing and total number of modules equal to MCCB TPN + 12 with blanking plates and fixed flush to wall and making good the disturbed surfaces etc, complete all as specified and as directed. Note: MCB SP/TPN will be measured and paid seperately. |
| 49 | S & F MCCB 100A 16KA complete all as specified and as directed |
| 50 | S & F Sheet metal enclosure MCB DB SPN 8 way with 200 amps rated bus bar 240 volts double door with magnetic locking system complete all as specified and directed. |
| 51 | S & F MCB SP 6 to 32 Amps 240 volts for fixing on MCB DB's complete all as specified and directed. |
| 52 | S & F MCB SPN 32-40 Amps 240 volts for fixing on MCB DB's complete all as specified and directed. |
| 53 | S & F Ceiling rose three terminal surface bakelite type AC 50 Hz 230 volts of size 65 x 50 mm complete all as specified and directed. |
| 54 | M&L Providing earthing with galvanized mild steel earth plate electrode 60 centimetre x 60 centimetre x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below ground level, the top edge of the earth plate at a depth of not less than 1.5 metres below ground level connected to galvanized iron earth wire of 4 mm dia by means of bolts, nuts and washers made out of GI / steel earth wire protected by GI light grade pipe 15 mm bore, 20mm dia light grade galvanised iron pipe with funnel wire mesh for watering and connecting to main switch board / control board all s shown in electrical plate of SSR Pt - I connected to earthing test point and including testing on completion complete all as specified and as directed.Note: The unit rate shall also include for excavation, earth work in hard/dense soil, plain cement concrete 1:3:6 type C1 by using 20 mm graded aggregate in pit, 50 mm thick RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) as in cover duly reinforced with 8 mm dia TMT bars @ 100mm centre to centre both ways, galvanised iron funnel with watering pipe, wire mesh, etc |
| 55 | M & L Submain wiring with 2 runs of single core 4.0 sqmm FRLS PVC insulated unsheated multistranded 1100 volts grade with copper conductor drawn through and including steel medium grade conclead and conduit accessories of medium grade not not less than 20 mm dia including one run of single core 4.0 sqmm FRLS PVC insulated unsheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable submain riwing complete all as specified and as directed.Note: 3 runs of 4 sqmmcable and 1 run of PVC conduit with accessories shall be measured as 1 unit of running metre. Note: Cutting/chases will me measured and paid seperately. Please Enable Macros to View BoQ information |