| 1 | Demolition of brickwork or stone boulder masonry, built in cement mortar or cement lime mortar including all quoins,arches, pillars,etc. but excluding ashlar facings, dressed stonework and precast concrete articles including removal of debris outside MoD land complete all as specified and directed. |
| 2 | M&L for brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed. |
| 3 | M&L for brick work with sub class 'B' bricks straight or curved on plan to any radius in half brick thick walling built in cement mortar 1:4 complete all as specified and directed. |
| 4 | Demolition of reinforced Concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) including removal of debris outside MoD land complete all as specified and directed. |
| 5 | M&L for Reinforced cement concrete (nominal mix) Type B1 1:2:4 (20mm graded stone aggregate) in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed. |
| 6 | Taking down cement plaster on brick or stone wall surfaces including glazed tiles wherever exists including raking out joints, hacking for key and scrubbing down with water including removal of debris outside MoD land complete all as specified and as directed. |
| 7 | M&L for 5mm thick plastering on ceiling surfaces in CM (1:3) surface finished even and fair complete all as specified and directed. |
| 8 | M&L for 20mm thick (in two layer) plastering on fair face of Brick surface with CM (1:4) mixed with WPC finish surface even and smooth with out using extra cement complete all as specified and directed. |
| 9 | M&L for 15mm thick cement plaster with CM (1:6) on other than fare face of brick wall finsh even and smooth without using extra cement complete all as specified and directed. |
| 10 | Taking down chowkhats or frame with shutter (without taking off shutters from the frame) area exc 1.5 sqm n.exe 4 sqm each complete all as specified and as directed. |
| 11 | Taking down rusted steel windows/ventilator of any description and size including shutters complete all as specified and as directed. |
| 12 | S&F factory made single extruded WPC(Wood polymer composite) solid door Frames of size 45 x 70mm comprising of virgin PVC polymer of K value 58-60(Suspension grade), calcium carbonate & natural fibres and non-toxic additives fabricated with mitre joints after applying PVC solvent cement and screwd with full body threaded star headed SS screws having minimum frame density of 750 Kg/cum, screw withdrawal strength of 2200 N(Face) & 1100 N (Edge), mimimum compressive strength of 58 N/Sqmm and resistance to spread of flame of class A category with property of being termite/borer proof, water/moisture proof & fire retardant & fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete all as specified and directed. |
| 13 | S&F factory made single extruded WPC(Wood polymer composite) solid flush door shutter of 30mm size comprising of virgin PVC polymer of K value 58-60(Suspension grade), calcium carbonate & natural fibres and non-toxic additives fabricated with mitre joints after applying PVC solvent cement and screwd with full body threaded star headed SS screws having minimum density of 650 Kg/cum, screw withdrawal strength of 1800 N(Face) & 900 N (Edge), mimimum compressive strength of 50 N/Sqmm, modulas of elasticity 850 N/sqmm & resistance to spread of flame of class A category with property of termite/borer proof , water/moisture proof & fire retardant & fixing with SS butt hinges of required size with necessary full body threaded star headed counter sunk SS screws, complete all as specified and directed. |
| 14 | S&F Aluminium anodised (powder coated) Three track sliding window frame with shutters with (2 nos glazed and one wire gauzed shutter) including all necessary joining cleats, hold fast, rubber gasket, snap beading and locking arrangements fixed with screws to wall etc. complete with glazing and including 5 mm thick tinted glass to aluminium frame work using rubber gasket and including stainless steel wire cloth of 0.36 mm dia & average width of aperture 1.40mm with staple or suitable fillets wire mesh fitted with screws and washers including deco aluminium grill with the following section of frame and shutter complete all as specified and directed:- (A) Sections for shutter :- (i) 'Vertical' section 38 x 20 x 1.10 mm thick. (ii) 'Interlock' section 38 x 20x 1.50 mm thick. (iii) 'Top/ Bottom' section 41 x 20 x 1.20 mm thick.(B) Section for frame :- (i) Top & Sides 92.36 x 29.70 x 1.50 mm thick. (ii) Bottom 92.36 x 29.70 x 1.50 mm thick |
| 15 | S&F Anodised powder coated aluminium (minimum thickness of powder coating 50 micron) frame for doors, windows, ventilators or aluminium frame for partition works etc with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. |
| 16 | S&F Anodised aluminium powder coated door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed. |
| 17 | S&F Anodised powder coated aluminium (minimum thickness of powder coating 50 micron) window and ventilator shutters, sliding type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed. |
| 18 | S&F 12 mm thick prelaminated particle boards (ISI marked), interior grade prelaminated both side with decorative choice lamination, fixed with necessary clips and other like to aluminium frame work, as in doors, windows, partition etc complete all as specified and as directed. |
| 19 | S&F decorative laminate of thickness 0.9 mm of type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instructions complete all as specified and directed. |
| 20 | S&F 5.5 mm thick glass ordinary quality, frosted on one side fixed to aluminium frame work exc 0.5 Sq. m in each pane complete all as specified & as directed. |
| 21 | S&F in repairs heavy duty double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box,main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel complete all as specified and directed. |
| 22 | S&F aluminium 4 levers Mortice lock, vertical type, size 100 mm complete all as specified and directed. |
| 23 | S&F Stainless steel handles 150mm long, bright polished complete all as specified and directed. |
| 24 | S&F Stainless steel handles 100mm long, bright polished complete all as specified and directed. |
| 25 | S&F 300mm long sliding door bolts with hasp stapple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bots and sliding bolts of extruded or cast aluminium alloy complete all as specified and directed. |
| 26 | S&F 150mm long sliding door bolts with hasp stapple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bots and sliding bolts of extruded or cast aluminium alloy complete all as specified and directed. |
| 27 | S&F Aluminium anodised barrel tower bolts of extruded section with 200 mm long bolt, complete all as specified and directed. |
| 28 | S&F Aluminium anodised barrel tower bolts of extruded section with 150 mm long bolt, complete all as specified and directed. |
| 29 | S&F Bearing hinges 100mm, cast brass, with Stainless steel hinge pin, bright polished and fixed, typeB-11 complete all as specified and directed. |
| 30 | S&F in repairs Stainless steel wire cloth having 0.36 mm nominal dia of wire and average width of appreature 1.40 mm and fixed with stainless wire staples complete all as specified and directed. |
| 31 | S&F in repairs aluminium (extruded section) body door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed. |
| 32 | S&F floor door stopper overall length of cover plate 150mm of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed. |
| 33 | Dismantling floor , earth or wall tiling including cement mortar bedding but not backing, removing serviceable tiles to store and rubbish off the premises outside MoD land complete all as specified and directed. |
| 34 | M&L for Anti-skid joint free ceramic (coloured) tiles 7-8mm thick area of each tiles exeeding 0.06sqm but n.exceeding 0.11 sqm in toilet/bath floor etc.set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified & as directed.Note: Screed bed shall be measured and paid separately |
| 35 | M&L for Anti-skid joint free ceramic coloured tiles area of each tiles (Square / rectangular) area exc 0.11 sqm but n. exc 0.18 sqm 7 to 8 mm thick in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed. Note: Screed bed shall be measured and paid separately |
| 36 | M&L for light shade Vitrified ceramic tiles 9-10 mm thick (Sqr/ rectangular) Polished, area of each tiles n.exc. 0.36sqm, in floors etc. set and jointed in neat cement slurry over & including a bedding layer of screed bed 15 mm thick in CM 1:6 and pointed in white/colour cement to match complete all as specified and directed. |
| 37 | M&L for glazed ceramic (coloured) tiles of size 450x300 6-7mm thick as in vertical surface/dado set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 38 | M&L for screed bed or bedding layer of mortar 15 mm thick in CM 1:6 for laying floor finishes complete all as specified and directed. |
| 39 | M&L for bedding layer of mortar 10 mm thick in CM 1:3 for laying wall/dado finishes complete all as specified and directed. |
| 40 | Demolition of cement concrete above ground floor n.exe 15cm thickness(below or above ground level) including removal of debris outside MoD land complete all as specified and directed. |
| 41 | M&L for 25mm thick cement concrete type B-0, 1:2:4 using 12.5mm graded stone aggregate as in sub base etc complete all as specified and directed. |
| 42 | Supply and applying two coats of High performance elastomeric cementitious waterproof coating sandwiched with 45 GSM glass fibre reinforcement on the entire floor and 1.0 m of all walls of all toilets as per following methodology:- Cleaning of exposed concrete surface by mechanical means or by hydro blasting to remove laitance, loose particles, contamination etc. which may hinder bonding. Coving of RCC joints with PCC (1:1.5:3) mixed with Integral Water Proofing compound. Applying one coat of Waterproofing membrane to concrete surfaces followed by application of 45GSM glass fibre on the wet surface. Applying second coat of waterproofing membrane at the right angles to the direction of first coat. Second coat shall be applied after the first coat gets dry. Sprinkling fine aggregate immediately after the application of second coat to get the mechanical key for protective plaster. Curing to Water proofing membrane to be carried out for minimum period of 3 days with ponding complete. The Water Proofing Product Should have Mixed density: 1.68g/cc (brushable consistency) complete all as specified and directed.Adhesion to concrete : >1N/mm2. Static crack accommodation: 1mm.( Fosroc/Elantas beck/Kunal conchem) ( Make : SIKA/FOSROC/Hindcon or equivalent as approved by GE) |
| 43 | M&L for bore packing of all the Spouts to be done with grouting admixture mixes with Cement Concrete / Mortar @225 ml per bag of Cement complete all as specified and directed. |
| 44 | M&L for cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing etc., and making good, cutting not exc 10 cm girth complete all as specified and directed. |
| 45 | Taking up or down 20mm bore steel water tubing and connections complete all as specified and as directed. |
| 46 | Taking up or down 25mm bore steel water tubing and connections complete all as specified and as directed. |
| 47 | Taking up or down 40mm or 50mm bore steel water tubing and connections complete all as specified and as directed. |
| 48 | Taking down UPVC pipe 50 mm bore with fittings complete all as specified and directed. |
| 49 | Dismantling of 100mm cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required complete all as specified and directed. |
| 50 | S&L 20 mm bore (Outer dia) CPVC pipes of SDR 11and plain CPVC SDR 11 fitting fixed on wall or floor (concealed ), ceiling or laying in floors complete all as directed. |
| 51 | S&F in repairs 25 mm bore (Outer dia) CPVC pipes of SDR 13.5 and plain CPVC SDR 11 fitting fixed on wall or floor, ceiling or laying in floors complete all as specified and directed. |
| 52 | S&F galvanised 40mm bore steel water tubing (GI pipe), medium grade with all fittings and fixed to wall, floor and ceiling complete all as specified and as directed.Note: Work shall be carried out to bldg upto height of 8 storey |
| 53 | S&F 50 mm bore (Outer dia) UPVC pipes of SCH-40 and plain UPVC SDR 11 fitting fixed on wall or floor, ceiling or laying in floors complete all as specified and directed. |
| 54 | S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 55 | S&F 110mm dia PVC (SWR) pipes double socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 56 | S&F 20 mm bore CPVC Male Brass Threaded Adaptor (MTA/ MBTA) complete all as specified and directed. |
| 57 | S&F 25 mm bore CPVC Male Brass Threaded Adaptor (MTA/ MBTA) complete all as specified and directed. |
| 58 | S&F 20mm bore CPVC Female Brass Threaded Adaptor (FTA/ FBTA) complete all as specified and directed. |
| 59 | S&F 25mm bore CPVC Female Brass Threaded Adaptor (FTA/ FBTA) complete all as specified and directed. |
| 60 | S&F 50 mm bore CPVC Male Brass Threaded Adaptor (MTA/ MBTA) complete all as specified and directed. |
| 61 | S&F 50 mm bore CPVC Female Brass Threaded Adaptor (FTA/ FBTA) complete all as specified and directed. |
| 62 | S&F PVC (SWR) bends 110mm dia complete all as specified and directed. |
| 63 | S&F PVC (SWR) junction single, (Single T) equal or unequal 110 mm dia complete all as specified and directed. |
| 64 | S&F PVC (SWR) junction double, (Double T) equal or unequal 110 mm dia complete all as specified and directed. |
| 65 | S&F in repairs vitreous china squatting pan of “Orissa” pattern of size 580 mmx 440mm white with integral foot rest (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe, anti syphonage pipe etc and making good to floor complete all as specified and as directed. |
| 66 | S&F in repairs vitreous China wash down water closet pan (padestal pattern) incl PVC seat cover , (excluding fixing bolts, flushing cistern and flush pipe) , including connection to drain ( or outgoing pipe) and to flushing pipe , etc., complete all as specified and directed. |
| 67 | S&F in repairs vitreous china wash hand basin, white, flat back, size 550mm x 400mm, exc chain and plug and porcelain stopper but including cutting for and pinning in ends of and with & including brackets, waste pipe & CP brass waste coupling of 32mm dia complete all as specified and directed. |
| 68 | S&F in repairs half stall Vitreous China urinals, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe complete all as specified and directed. |
| 69 | S&F in repairs Brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed complete all as specified and directed. |
| 70 | S&F in repairs 15mm bore CP angular valve fancy type,with crutch handle, screwed for iron pipe or for brass ferrule and fixed of following size complete all as specified and directed. |
| 71 | S&F in repairs 15 mm Dia CP Bib taps,fancy type with crutch handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 72 | S&F in repairs 15 mm Dia CP Bib taps (Two-in-one), fancy type with crutch handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 73 | S&F in repairs 15 mm Dia CP stop cock(concealed type) , with crutch handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 74 | S&F in repairs 15 mm bore CP pillar taps, with capstan heads, chromium plated, Fancy type screwed down for pipe, high pressure ,complete all as specified and directed. |
| 75 | S&F in repairs 25 mm Dia brass gun metal gate valve , with crutch handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 76 | S&F in repairs 15 mm bore brass CP mixer, for mixing Hot and Cold water screwed down for iron pipe, complete all as specified and directed. |
| 77 | S&F in repairs 15 mm bore Brass CP Clinical faucet screwed down for iron pipe and fixed complete all as specified and directed. |
| 78 | S&F in repairs wall mounted Grab bar/Hand Rails for disable pateints 600 mm long fixing in wall complete all as specified and directed. |
| 79 | S&F in repairs wall mounted L Shaped Grab bar with 500 & 700 mm long for disable pateints fixing in wall complete all as specified and directed. |
| 80 | S&F in repairs CP Health faucet with 1 mtr SS Tube & Hook complete all as specified and directed. |
| 81 | S&F in repairs 600 mm PVC connection pipe 15 mm size with PTMT nut of following length complete all as specified and directed . |
| 82 | S&F in repairs 110/125 mm floor trap fixed in floor with grating incl jointing with solvent 1:2:4 cement concrete, complete all as specified and directed. |
| 83 | S&F in repairs 600 mm x 450 x 6 mm bevelled edge mirror of selected quality glass, mounted on 6mm thick| AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass| screws and cup washers complete all as specified and directed. |
| 84 | S&F in repairs 15 mm bore brass Chromium Plated Centre Hole basin mixer, for mixing Hot and Cold water screwed down for iron pipe, complete all as specified and directed. Make : Prayag Cat part No 9350-N or equivelant as approved by GE |
| 85 | S&F in repairs brass CP Shower roses in repair with or without swivel joints, 125mm size, including fixing to steel pipes or union complete all as specified and directed. |
| 86 | S&F in repairs CP Soap dish, fixed to plugs with chromium plated brass screws comlete all as specified and directed. |
| 87 | S&F in repairs Curtain rails with Decorative type drappery Rod along with all fittings of 25 mm dia complete all as specfied and directed. |
| 88 | S&F in repairs brass CP Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specfied and directed. |
| 89 | S&F in repairs peg set (six pin) including all necessary fittings all as per manufacturer's instructions complete all as specified and directed. |
| 90 | S&F in repairs washroom Corner shelf (Three tier) including all necessary fittings complete all as specified and directed. |
| 91 | S&F in repairs sinks with drainage board made of stain less steel 1mm thick,kitchen with plugs, washer and wastes; Including bedding in cement mortor to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mmx460mm bowl size 410mmx330mmx160mm complete all as specified and directed. |
| 92 | S&F in repairs sinks without drainage board made of stain less steel 1mm thick,kitchen with plugs, washer and wastes; Including bedding in cement mortor to dwarf wall or including fixing cantilever brackets and connecting union to pipe bowl size 410mmx330mmx160mm complete all as specified and directed. |
| 93 | S&F in repairs PVC valveless, symphonic action type low level flushing cistern white with inlet ball valve, float and handle including brackets, 10 ltr capacity complete with flush pipe(Long bend) 32mm dia complete all as specified & directed. |
| 94 | S&F in repairs Louvers type powder coated Aluminium ventilator assembled partially with PVC exhaust fan of 200mm sweep and partially fixed with frosted glass of area n.exc 0.5 sqm including all necessary fittings complete all as specified and directed. |
| 95 | Dismantling of old unserviceable water tank, removing from site and supply and fixing of rotational moulded polythene water storage tank 1000 litre capacity ISI marked (cylindrical, vertical, double layered with closed top) hoisted and fixed in position with & including PVC float valve 20mm bore weight not less than 210gms. Complete. |
| 96 | All as per BOQ serial item No 95 above but capacity 2000 litre complete all as specified and directed. |
| 97 | S&F in replacement framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 98 | Complete removal of existing treatment by using electric sander machine or steel wire brushing to remove all dust and loose scale etc of wall surfaces & prepare to receive wall care putty complete all as specified & directed. |
| 99 | M&L for 1mm thick wall care putty on wall including rubbing with sand paper to achieve a smooth surface & sharp straight edges etc. complete all as specified & as directed. |
| 100 | Preparation old decorated walls and M&L for applying two coats of acrylic oil emulsion distemper complete all as specified and directed. |
| 101 | Preparation of decorated Ceiling and M&L for applying two coats of acrylic oil emulsion distemper complete all as specified and directed. |
| 102 | Preparation of newly plastered wall surface and M&L for applying two coats of oil bound distemper over & including a coat of primer on complete all as specified and directed. |
| 103 | Preparation of newly plastered ceiling surface & M&L for applying three coats of white wash complete all as specified and directed. |
| 104 | M&L for two coats of Anti fungal anti bacteria paint on old decorated surface of internal walls incl removal of existing preparation and 3mm wall care putty as per manufacturers instructions complete all as specified and directed. |
| 105 | All as per BOQ Serial item No 104 above but in ceiling surface complete all as specified and as directed. |
| 106 | M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over 2mm thick wall care putty and icluding priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed. |
| 107 | Preparing of new steel surfaces and M&L for applying two coats of synthetic enamelled paint over a coat of red oxide primer complete all as specified and as directed. |
| 108 | M&L for two Coats of Synthetic Enamel Paint over one coat of primer to steel and iron surfaces of any description, not otherwise described including preparation of new or previously untreated surface complete all as specified and directed. |
| 109 | M&L for one coat of synthetic enamel paint, area exc.10cm width or girth over Old painted wooden surfaces including preparation of surface complete all as specified and directed. |
| 110 | Providing mixing and applying over the finished substrate using Nitocote EP140 or equivalent based on solvented epoxy resins specially formulated to provide a durable coating suitable for application to both vertical and horizontal surfaces. As a hygienic and chemical resistant coating for mild steel, steel tanks and metal columns, sluices and ducts having properties Specific gravity 1.25 to 1.35 g/cc, No. of coats - 2, Wet film thickness per coat 100 microns, total dry film thickness 90 microns, Adhesive bond strength Exceeds 1N/mm2, time between coats 4 - 6 hrs at 20°c 3 - 5 hrs at 35°c, Initial hardness 24 hrs at 20°c 18 hrs at 35°c, Full cure 7 days and shall be applied over prepare substrate at a thickness of 180 micron (90micron/coat} dry film in two coats for internal sides of tank as per manufacturers specifications. The item rate shall be including of all kinds of labour, tools & tackle, machineries, lead & lift, mathadi charges, curing, wastages, consumable, cleaning, shifting of debris outside the site premises, surface preparation etc. complete as per design, drawing & instructions of EiC complete all as specified and directed. |
| 111 | M&L for one coat of plastic emulsion paint on old decorated surface of internal walls incl preparation complete all as specified and directed. |
| 112 | S&F in repairs L-shaped rubberised corner guard for sharp vertical edges of length 1200mm, width 100 x 100mm reflective type of thickness 10mm complete all as specified & as directed. |
| 113 | M&L for cement concrete type B0 (1:2:4) using 12.5 mm graded stone aggregate as in hold fast block kerbs or mud stops, rounded or chamfered etc comlete all as specified and directed. |
| 114 | Supply only Intregal water proofing compound complete all as specified and directed. |
| 115 | S&F in repairs 3 mm thick ACP sheet, the ACP panel contains, 0.21 to 0.25 mm thick aluminium alloy coil along with a 2.5 mm core. The thin coils of the same thickness in the bottom and top layer, above which there is either a two coat or three coat PVDF paint coat along with the protective film upto 8storey incl scaffolding complete all as specified and directed. Please Enable Macros to View BoQ information |