| 1 | Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 2 | M& for Plain cement concrete 1:3:6 type C2 using 40mm graded stone aggregate as in path/hard standing, surface channel and drains, complete all as specified. |
| 3 | M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:6, complete all as specified and directed. |
| 4 | M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in built in CM 1:4, complete all as specified and directed. |
| 5 | M&L for Pre-cast cement concrete block (PCC 1:3:6 Type C-1) masonry with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6, complete all as specified and directed. |
| 6 | M&L for Boulder pitching, pitching is grouted with cement and sand mortar 1:6, complete all as specified and directed. Note : Thickness of stone shall be 20cm. |
| 7 | M&L for Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in CM 1:6 complete all as specified and directed. |
| 8 | M&L for Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in CM 1:6 (Except stone) complete all as specified and directed. |
| 9 | Extra over stone walling for hammer dressing to face stones and dressing of face beds and joints, as specified, of random rubble walling, uncoursed or brought upto courses Hammer dressing with maximum depression on face from straight edge held against the dressed surface not exc 40mm granite or trap stone complete all as specified and directed. |
| 10 | Demolition of brickwork/blockwork or stone/ boulder masonry, built in cement or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 11 | Taking down cement or cement lime plaster of any description on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water, etc. |
| 12 | M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 including finished the surface even and smooth with out using extra cement complete all as specified and directed. |
| 13 | M&L for preparation of new plastered surface of wall and applying two coats of weather coat paint APEX Ultima or equivalent product over a coat of alkali resistance primer complete all as specified and directed. |
| 14 | M&L for PCC 1:2:4 type B1 (20mm graded stone aggregate) as in coping complete all as specified and directed. |
| 15 | Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar complete all as specified and directed. |
| 16 | M&L for chequered cement concrete tiles 300x300x20mm thick set and jointed and pointed in neat cement slurry in floor with grey cement and no pigment complete all as specified and directed. |
| 17 | M&L 75mm thick PCC 1:4:8 type D2, using 40mm graded stone aggregate as in floors complete all as specified and directed. |
| 18 | M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 19 | M&L for 20mm thick screed bed or bedding layer for laying floor finishes in CM 1:6 complete all as specified and directed. |
| 20 | M&L for cement concrete type C-2 1:3:6 (40mm graded stone aggregate) 75 mm thick in Plinth protection including necessary formwork for sides complete all as specified and directed |
| 21 | S&F Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and no pigment. complete all as specified and directed. |
| 22 | -ditto- same as tem No.46 but except tiles complete all as specified and directed. |
| 23 | Supply and spreading coarse aggregate from 12.5mm to 4.75mm not exc 25cm thick complete all as specified and directed. |
| 24 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed. |
| 25 | S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed. |
| 26 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed. |
| 27 | S&F mild steel work as hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 28 | S&F mild steel work as framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 29 | S&F rolled mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed. |
| 30 | S&F rolled mild steel work as in framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed. |
| 31 | S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.11611979 grade St.-240 complete all as specified and directed. |
| 32 | Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement etc,omplete all as specified and directed. |
| 33 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 34 | M&L prepartion of new steel surface of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc crome complete all as specified and directed. |
| 35 | M&L for preparation of old decorated wall surfaces and applying one coat of exterior emulsion weather coat paint ACE of Asian paints or equivalent of other brands complete all as specified and directed Note: The above item used for compound wall, Road side kerbs,Decorative wall, Boundary wall and certain buildings which needs frequent paintings due to VIP visits |
| 36 | M&L for preparation of old steel surface of any description over 10 CM width/girth and applying one coat of synthetic enamal paint complete all as specified and directed. |
| 37 | M&L one coat of exterior emulsion weather coat anti fungal paint over the old wall surface including the preparation of the surfaces complete all as specified and directed.Make : Asian paints Apex Ultima/Berger Weather coat Antidust/Nerolac Excel total or other equivalent product |
| 38 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground embedded in concrete, brick work, masonry etc complete all as specified and directed. |
| 39 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed. |
| 40 | M&L for PCC 1:3:6 type C2, using 40mm graded stone aggregate as in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) complete all as specified and directed. |
| 41 | S&F Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 42 | M&L for Providing reinforced cement concrete type B-l, 1:2:4(20 mm graded aggregate) in precast posts, fencing posts, straining or terminal posts, struts etc. for fencing, average sectional area exc 100 sq. cm and not exc 250 sqcm, with or without chamfered angles and flat, splayed, rounded or mitred tops as directed and fixed complete all as specified and directed. |
| 43 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed. |
| 44 | Supply only Chain link MS galvanisd fencing, any size or type complete all as specified and directed. |
| 45 | Dismantling of chain link fencing any type and any size complete all as specified and directed. |
| 46 | S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long, diameter of neck 11 to 15mm complete all as specified and directed. |
| 47 | S&F in repairs Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured complete all as specified and directed. |
| 48 | Restraining Resecuring including making good staples of Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured complete all as specified and directed. |
| 49 | S&F Galvanised steel punched type concertina coil 610mm dia(in stretched position) with no of circles 80 Nos of 200 clips with weight 7.5 to 8Kg/coil and recommended average coverage is 6Rm per coil, hot dipped galvanised steel wire coated with CLR anti corossive paint, making diamond shape with help of dove tail clips (18 SWG) fixed over barbed wire at points wherever coil touches the bottom of barbed wire with the help of hog rings (14 SWG) complete all as specified and as directed. |
| 50 | Cleaning of septic tank by removing man hole cover including removing of earth/soil spread over the cover if any, from the frame of a septic tank and receiving chambers, pumping out liquid contents and excavating night soil sediments and waste materials etc, clearing off up to the bottom floor and dispose off the materials to a distance not exceeding 100 mtrs from the septic tank to a pit suitably as directed by Hygenic authorities excavated to contain night soil, place back the man hole cover to its original position and removing all vegetable roots if any and making good surroundings complete all as specified and directed, including the cost of excavating the pit and refilling back. Note:-The measurment shall be inclusive of water content from bottom of tank to the invert level of outlet pipe, complete all as specified and directed. |
| 51 | Opening manholes of septic tanks, removing night soil, other sediments, solid waste and liquid waste in any condition by pumping or any other mechanical means, cleaning internal surfaces of the tank with clean water and refixing the manhole on completion of work complete all as specified and directed.Notes:-(a) The night soil, sediments, solid and liquid waste in any condition removed from septic tank shall be taken away from respective vicinities and premised in closed containers/converyance and disposed off out of Defence land.(b) Disposal of the same shall be the responsibility of the Contractor. Disposal of waste shall be made in accordance with the regulations of authorities concerned without any extra expediture to the Government. |
| 52 | Material and labour for Cleaning of existing sewage system/pipe line 100/150/200mm dia (length of pipe line manhole to manhole not exceeding 15mtr) including cleaning of manholes (any type rectangular/square/circular) located in different situations/sites, taking off the manhole cover (CI or RCC) and placing in the same original position after getting out liquid/sludge/solid contents from the manholes/sewage line and complete perfect function/running/flowing condition without any obstruction by removing all blockage in system with manual labour (rodding manually) or by mechanically sewage suction pump (at contractor;s discretion as required at site) making it fully functional to the entire satisfaction of Engineer-in-charge including removing of all wastes, solid or liquid sludge through closed container and depositing the sludge in a pit (at empty/open area) of suitable size from the line/clony area where directed and covering the same with the soil obtained from excavation of pit after treating the sludge by spreading the bleaching powder as directed to reduce the foul gases including all excavations and earthwork complete all as specified and as directed by Engineer-in-Charge. Note :- Disposal of the same shall be the responsibility of the Contractor. Disposal of waste shall be made in accordance with the regulations of authorities concerned without any extra expediture to the Government |
| 53 | Material and labour for Cleaning of existing sewage system/pipe line 100/150/200mm dia (length of pipe line manhole to manhole exceeding 15mtr but not exceeding 30mtr) including cleaning of manholes (any type rectangular/square/circular) located in different situations/sites, taking off the manhole cover (CI or RCC) and placing in the same original position after getting out liquid/sludge/solid contents from the manholes/sewage line and complete perfect function/running/flowing condition without any obstruction by removing all blockage in system by mechanically sewage suction pump making it fully functional to the entire satisfaction of Engineer-in-charge including removing of all wastes, solid or liquid sludge through closed container and depositing the sludge in a pit (at empty/open area) of suitable size from the line/clony area where directed and covering the same with the soil obtained from excavation of pit after treating the sludge by spreading the bleaching powder as directed to reduce the foul gases including all excavations and earthwork complete all as specified and as directed by Engineer-in-Charge. Note :- Disposal of the same shall be the responsibility of the Contractor. Disposal of waste shall be made in accordance with the regulations of authorities concerned without any extra expediture to the Government |
| 54 | Cleaning SWG/PVC/CI pipe sewage line manually or mechanically using cleaning rod or compressor and removing foreign material after clearing existing blockage for 75mm dia pipe in vertical walls/floors complete all as specified and directed. |
| 55 | Cleaning SWG/PVC/CI pipe sewage line manually or mechanically using cleaning rod or compressor and removing foreign material after clearing existing blockage for 110mm dia pipe on vertical walls/floors complete all as specified and directed. |
| 56 | M&L for surface dressing not exc 15cn deep in soft/loosed soil with grass around the manhole, soak well, drain and septic tank all as specified and directed. |
| 57 | Material and labour for Cleaning/removal of blockage from bathroom, kitchen, WHB and urinals including connected Nahani traps / gully traps/floor traps, grating of trap, waste pipes, pipe in any length upto Ist manhole etc choked with mud / other accumulated sludge and getting out, washing thoroughly at any location, at any floor by rodding/choke remover/Pressure technique/manually or otherwise to clear blockage upto entire satisfaction of users, including refixing of oval assess door covers with new nuts & washers, refixing manhole covers and for making good damaged surfaces of sorroundings of nahani trap, Gulli trap/floor traps etc with CM 1:3 or white cement complete all as directed by Engineer in Charge. Note :- Obtained waste materials shall be disposed to a distance not less than 100 mtrs as directed by Hygenic authorities) and covering the same with the soil obtained from excavation of pit after treating the sludge by spreading the bleaching powder as directed to reduce the foul gases complete all as specified and directed. |
| 58 | Material and labour for Cleaning/removal of blockage from EWC/IWC (any type) including connected traps (any type), pipe in any length upto Ist manhole etc choked with mud / other accumulated sludge and getting out, washing thoroughly at any location, at any floor by rodding/choke remover/Pressure technique/manually or otherwise to clear blockage upto entire satisfaction of users, including refixing of oval assess door covers with new nuts & washers and refixing manhole covers, complete all as specified and as directed by Engineer-in-Charge. Note :- Obtained waste materials shall be disposed to a distance not less than 100 mtrs as directed by Hygenic authorities) and covering the same with the soil obtained from excavation of pit after treating the sludge by spreading the bleaching powder as directed to reduce the foul gases complete all as specified and directed. |
| 59 | Excavation in trenches n.exc 1.5 M wide and n exc 1.5 M depth and getting out in hard/dense soil complete all as specified and directed. |
| 60 | M&L for PCC 1:4:8 type D2, using 40 mm graded aggregate in foundation, mass concrete complete all as specified and directed. |
| 61 | S&F in repairs 150 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in walls or floors complete all as specified and directed |
| 62 | M&L for cement concrete bed to drain pipe 150 mm dia in cement concrete 1:3:6 type C2 including packing under the haunching on sides all as directed and specified |
| 63 | S&F in repairs 50mm bore Unplasticized PVC pipes of pressure rating 10 kgf/sqcm in repairs complete all as specified and directed |
| 64 | S&F in repairs 75 mm, bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls, ceilings or in floors etc and including necessary scafolding where is required, complete all as specified and directed. |
| 65 | S&F in repairs 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls, ceilings or in floors etc and including necessary scafolding where is required, complete all as specified and directed. |
| 66 | S&F in reapirs PVC (SWR) gully trap 125/110 mm setting and jointing with solvent cement and making good the surfaces all as directed and specified |
| 67 | S & F in repair 110 mm bore PVC(SWR) bends of any radius etc, complete all as specified and directed . |
| 68 | S & F in repair 110 mm bore PVC (SWR) junction single,(Single T) equal or unequal etc, complete all as specified and directed . |
| 69 | S & F in repair 75 mm bore PVC(SWR) bends of any radius etc, complete all as specified and directed . |
| 70 | S & F in repair 75 mm bore PVC (SWR) junction single,(Single T) equal or unequal etc, complete all as specified and directed . |
| 71 | S&F PVC eaves gutter with rounded edges for drain out for surrounding of bldg/shed as per directed by Engr-in-charge complete all as specified and directed |
| 72 | Returning, filling ramming etc in layers n.exc 25 cum including levelling, watering etc complete all as directed |
| 73 | Removing excavated materials not exc 50 Mtr and depositing where directed at level n. exc 1.5 Mtr above from the starting point complete all as specified and directed. |
| 74 | M&L of cement concrete type B1 1:2:4 20mm graded aggregate as in surface channels, benching inside manholes complete all as specified and directed |
| 75 | Demolition for cement concrete (reinforcement cut as required to facilitate demolition) is reinforced of any description and in any position not otherwise specifically provided for |
| 76 | S&F mild steel TMT bar 6 to 8mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm including clips, complete all as specified and directed. |
| 77 | M&L for precast reinforced concrete 1:2:4 type B1 using 20 mm graded stone aggregate for cover slab set in and pointed in CM 1:6 including necessary formwork complete all as specified and directed. |
| 78 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises. |
| 79 | M&L non skid ceramic coloured tiles 7 to 8 mm thick (Square/ rectangular ) in floors ,area of each tile exc 0.11 sqm but n.exc. 0.18 sqm set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tiles, over and including 15 mm thick screed plaster in CM 1:6 complete all as specified and directed |
| 80 | S&F in repair Vitreous china wash down water closet pan (pedestal pattern) including connect to outgoing pipe and flush pipe (excluding fixing bolts, flushing cistern) complete all as specified and directed by Engr-in-Charge. |
| 81 | S&F in repairs PVC overhead tank cover for tanks of capacity 1000 ltr incljuding locking bolts and securing the hinges in proper position complete all as specified and directed. |
| 82 | S&F in repairs PVC overhead tank cover for tanks of capacity 500 ltr incljuding locking bolts and securing the hinges in proper position complete all as specified and directed. |
| 83 | S&F in repairs tank connector, PVC suitable for fixing to outlet pipe of any description and 32mm dia bore commplete all as specified and directed. |
| 84 | S&F in repairs PVC gate valve with handle, fixed both end for PVC pipe of 32mm dia bore complete all as specified and directed. |
| 85 | Cleaning and removing all scale and dirt etc from tanks of capacity exc 500 and not exc 1000 ltrs and from mouth of circulation pipes etc complete all as specified and directed. Note : Tank has to be cleaned mechanically by reputed firm |
| 86 | Cleaning and removing all scale and dirt etc from tanks of capacity exc 250 and not exc 500 ltrs and from mouth of circulation pipes etc complete all as specified and directed. |
| 87 | S&F in repairs ball brass valve, high pressure, with polyethene float and fly nut complete, screwed for iron pipe of brass ferrule of 25mm dia bore complete all as specified and direceted. |
| 88 | S&F 500 ltr Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part including dismantling water tanks and removing to store complete all as specified and directed. complete all as specified and directed. |
| 89 | S&F 750 ltr Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-1 including dismantling water tanks and removing to store complete all as specified and directed. |
| 90 | S&F 1000 ltr Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-1 including dismantling water tanks and removing to store complete all as specified and directed. |
| 91 | S&F in repairs 20mm dia bore Unplasticised PVC ASTM pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe |
| 92 | S&F in repairs 32mm dia bore Unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe |
| 93 | S& F in repairs health faucet, CP with flexible arm for pipe 15mm bore dia complete all as specified and directed by Engr-in-Charge. |
| 94 | S&F in repairs fancy type Bib taps, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe 15mm bore or for brass ferrule and fixed complete all as specified and directed. |
| 95 | S&F in repairs Pillar taps,fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed to pipe complete all as specified and directed for 15mm bore pipe |
| 96 | S&F in repairs Stop valve/angle vavles, cast copper alloy, fancy type chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed for 15mm dia pipe complete all as specified and directed. Please Enable Macros to View BoQ information |