| 1 | Purchasing and installation of Shreader Machine with specification as mentioned below:-motor output - 4HPfeed system - manual feedfeed opening size - 500x500x300 mminput torque - 1628 nmcutting mechanism - rotary bladesno. of blades - 24shredding speed - 16 rpmVoltage-3 phase 440 Vincluding all labour charges and transportation etc.as per directions of engg in charge. |
| 2 | Boring, Providing and installing cast in situ single under reamed pilesof specified diameter and length in M 20 cement concrete, excludingthe cost of steel reinforcement but including the cost of boring,cement concrete, all complete. (Length of pile for payment shall bemeasured upto to the bottom of pile cap) :300 mm dia piles |
| 3 | Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding upto floor level including costof binding wire, wastage and over laps upto 12mm horizontal/ inclinedposition of reinforcement bars in slab and beams, plinth, chajjas,lintels, upto 4.5m vertical length of reinforcement in wall columns (overlaps shall be provided as per requirement of IS : 13920; IS 456 & SP :34) etc. complete. Mild steel and Medium Tensile steel bars. |
| 4 | Cement concrete grade M-10 (Nominal Mix) with 40 mm maximumsize of stone aggregate |
| 5 | Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding upto floor level including costof binding wire, wastage and over laps upto 12mm horizontal/ inclinedposition of reinforcement bars in slab and beams, plinth, chajjas,lintels, upto 4.5m vertical length of reinforcement in wall columns (overlaps shall be provided as per requirement of IS : 13920; IS 456 & SP :34) etc. complete. Mild steel and Medium Tensile steel bars. |
| 6 | Centering and shuttering including strutting, propping stretching etc.complete for and removal of form work by sheet plate or ply woodshuttering for :Foundations, footings, bases of columns, etc. For mass concrete |
| 7 | Providing and laying in position specified grade of reinforcedcement concrete excluding the cost of centering, shuttering,finishing and reinforcement - All work up to plinth level :Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum sizeof stone aggregate. |
| 8 | Centering and shuttering including strutting, propping stretching etc.complete for and removal of form work by sheet plate or ply woodshuttering for : Foundations, footings, bases of columns, etc. For mass concrete. |
| 9 | Providing and laying in position specified grade of reinforcedcement concrete excluding the cost of centering, shuttering,finishing and reinforcement - All work up to plinth level :Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum sizeof stone aggregate. |
| 10 | Brick work with fly ash lime bricks (FALG Bricks) conforming to IS:12894-2002, class designation 75 Kg/CM2 (average compressive strength) insuperstructure above plinth level up to floor 2 level including the cost ofscaffolding : Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 11 | Supplying and filling in plinth under floors including,watering, ramming consolidating and dressing complete.Moorum/Hard copra |
| 12 | Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding upto floor level including costof binding wire, wastage and over laps upto 12mm horizontal/ inclinedposition of reinforcement bars in slab and beams, plinth, chajjas,lintels, upto 4.5m vertical length of reinforcement in wall columns (overlaps shall be provided as per requirement of IS : 13920; IS 456 & SP :34) etc. complete.Mild steel and Medium Tensile steel bars |
| 13 | Providing and laying in position specified grade of reinforcedcement concrete excluding the cost of centering, shuttering,finishing and reinforcement - All work up to plinth level :Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum sizeof stone aggregate. |
| 14 | Steel work in built up M.S. tubular section (round, square orrectangular Hollow tube etc.) trusses/frame work etc./ railing work etc.including cutting, hoisting fixing in position and applying a priming coatof approved steel primer, welded and bolted including special shapedwashers etc. complete.Hot finished welded type tubes |
| 15 | Supply & installation of precoated galvanised iron profile sheets(size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm ±5% total coated thickness (TCT) thick Zinccoating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 micronsepoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 micronsminimum to avoid scratches while transportation and should besupplied in single length upto 12 meter or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tappingscrews of size (5.5x 55mm) with EPDM seal or with polymer coatedJ or L hooks, bolts and nuts 8mm diameter with bitumen and G.I.limpet washers or with G.I. limpet washers filled with white leadcomplete upto any pitch in horizontal/vertical or curved surfacesexcluding the cost of purlins, rafters and trusses and includingcutting to size and shape wherever required. |
| 16 | Providing & fixing UV stabilised fiberglass reinforced plasticsheet roofing up to any pitch including fixing with polymer coated'J' or 'L' hooks, bolts & nuts 8mm dia. G.I plain/bitumen washerscomplete but excluding the cost of purlins, rafters, trusses etc. Thesheets shall be manufactured out of 2400 TEX panel rovigsincorporating minimum 0.3% Ultra-violet stabiliser in resin systemunder approximately 2400 psi and hot cured. They shall be ofuniform pigmentation and thickness without air pockets and shallconform to IS 10192 and IS 12866.The sheets shall be opaque ortranslucent, clear or pigmented, textured or smooth as specified.2mm thick flat. |
| 17 | Structural steel work riveted, bolted or welded in built upsections, trusses and framed work, including cutting, hoisting, fixingin position and applying a priming coat of approved steel primer allcomplete: |
| 18 | Kota stone 25mm thick flooring over 20 mm (average) thick base laid overand jointed with grey cement slurry mixed with pigment to match theshade of the slab including rubbing and polishing complete withbase of 1:4 cement mortar (1 cement : 4 course sand) (minimum size ofkota stone 2.0 sqft) |
| 19 | 15 mm cement plaster on rough side of single or half brick wall of mix 1:4 (1 cement: 4 sand) |
| 20 | Applying one coat of cement primer of approved brand andmanufacture on wall surface : Cement primer. |
| 21 | Wall painting with plastic emulsion paint of approved brand andmanufacture to give an even shade: |
| 22 | Painting Steel work with Deluxe Multi Surface Paint to give an evenshade. Two or more coat applied @0.90 ltr/10 sqm over an under coatof primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture Please Enable Macros to View BoQ information |