| Sl. No. | Item Description |
| 1 | Labour only for dismantling stay assembly complete as specified.Note : demolition of concrete and excavation shall be measured separately. |
| 2 | Supply & fixing stay assembly complete with all accessories, such as stay-plate 300x300x6mm, stay-rod 180 cm long and 20 mm dia with nuts including GI bow turn buckle etc., all as per Electrical plate No 1 or SSR -2009 Part-I complete all as specified. Note. Loop type insulator, stay clamp, excavation, concrete shall be measured and paid separately under relevant items of Sch A |
| 3 | M&L for loop type insulators vitreous porcelain white, brown or green large size with overall dimensions 65x90 mm clearance of hole 25.5 mm complete all as specified. |
| 4 | Labour only dismantling of ACSR or AAC conductors complete all as specified. |
| 5 | S&F ACSR conductor of any type and size stretching properly on insulators and binding with aluminium binding wires, jumpers including fixing on insulators on each poles in span and tightening with permissible sag in between spans etc complete all as specified. |
| 6 | Labour only dismantling insulators any type, any size |
| 7 | S&F pin type porcelain white / brown / green / insulator(in place of defective one) including galvanized mild steel spindle, two galvanized iron Washers and one galvanized iron nut,100mm height 65mm dia for 1100 volts grade complete all as specified. |
| 8 | S&F shackle type insulator(in place of defective one) vitreous porcelain white / brown / green with and including galvanized mild steel straps, washers, insulator, bolts and nuts, insulators of size 100mm height and 115mm max dia with working pressure 1100 volt and galvanized steel straps 31X 5 mm size and dia of bolts 14mm complete all as specified. |
| 9 | Supplying and fixing 1100 volts grade heavy duty 2 core x 10 Sqmm cable PVC insulated solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4mm suspension wire, one twin core cable circular complete all as specified. |
| 10 | S&F in replacement of 1100 V grade straight through cable jointing kit complete with jointing material heat shrink type and accessories suitable for 3.5 / 4 Core X 10 to 16 Sqmm size XLPE/ AB cable, armoured, Al conductor cable and taking down of old cable etc all as sped and directed. |
| 11 | All as per Item No. 10 above but for cable size 4/3.5 core x 25 - 50 Sqmm |
| 12 | All as per Item No. 10 above but for cable size 4/3.5 core x 70 - 95 Sqmm |
| 13 | Supply and fixing cable jointing kit for 1100 V (Earthed) Grade cable for indoor/out door type termination heat shrink type joint complete with jointing material and accessories suitable for three core XLPE armoured alumunium conductor cable of size 95-150 Sqmm all as specified and directed. |
| 14 | Supply and fixing cable jointing kit for 1100 V (Earthed) Grade cable for indoor/out door type termination heat shrink type joint complete with jointing material and accessories suitable for three core XLPE armoured alumunium conductor cable of size 185 Sqmm all as specified and directed. |
| 15 | Supply, laying, testing and commissioning 4 core 10sqmm, 1100 volts grade heavy duty XLPE cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape, armoured with galvanized steel wire or strip and over all PVC sheathed solid conductor complete all as specified and directed including taking down/removing the old unserviceable cable complete all as specified.Note:- Earth work, sand cushioning, bricks protection & GI pipe where reqd. shall be measured & paid separately under relevant items. |
| 16 | All as per Item No. 15 above but cable size of cross sectional area 10 Sqmm of 2 core |
| 17 | All as per Item No. 15 above but cable size of cross sectional area 16 Sqmm of 2 core |
| 18 | All as per Item No. 15 above but cable size of cross sectional area 16 Sqmm of 4 core |
| 19 | All as per Item No. 15 above but cable size of cross sectional area 25 Sqmm of 4 core |
| 20 | All as per Item No. 15 above but cable size of cross sectional area 50 Sqmm of 3½ core |
| 21 | All as per Item No. 15 above but cable size of cross sectional area 70 Sqmm of 3½ core |
| 22 | All as per Item No. 15 above but cable size of cross sectional area 95 Sqmm of 3½ core |
| 23 | Supply and fix factory SMC outdoor pole mounted Junction box of size not less than 300x200x105 mm with and including MCB SP 6 Amp, 240 V 'B' series 10 kA and bus bar including fixing with two FI clamps 25x3mm including nut-bolts and washers etc. and taking down old UNSV kiosk box complete all as specified. |
| 24 | Supply and fix LT overhead lines on existing 09 mtr LT steel tubular poles with XLPE insulated AB cable 3-corex95 sqmm (insulated phase conductors) + 1x70 sqmm (bare neutral messenger conductor) + 1x16 sqmm (street light phase) ISI marked complete all as specified and directed. |
| 25 | Supply and fix LT overhead lines on existing 09 mtr LT steel tubular poles with XLPE insulated AB cable 3-core x 70 sqmm (insulated phase conductors) + 1x50 sqmm (bare neutral messenger conductor) + 1x16 sqmm ISI marked complete all as specified and directed. |
| 26 | Supply and fix LT overhead lines on existing 09 mtr LT steel tubular poles with XLPE insulated AB cable 3-core x 50 sqmm (insulated phase conductors) + 1x35 sqmm (bare neutral messenger conductor) + 1x16 sqmm ISI marked complete all as specified and directed. |
| 27 | Supply and fix insulation piercing connectors (IPC) for main cable of 16-95 sqmm with taps ranging from 4-50 sqmm for connecting service cables from LT OH aerial bunched cable (AB cable), contact plate made of aluminium, long neck share head nut ensuring reliable installation , weather and UV resistant glass fiber reinforced material complete all as specified and directed |
| 28 | Supply and fix suspension clamp suitable for 16-95 sqmm size neutral conductor, clamp and link made of polymer to give additional insulation between cable and pole, clamp made of weather resistant polymer and UV resistant glass fiber complete all as specified and directed.Note : MS Clamp, nut-bolts and washers shall be measured separately. |
| 29 | Supply and fix anchoring clamp suitable for cable size 16-95 sqmm with Al. alloy body, bail made of stainless steel , wadges of weather and UV resistant polymer complete all as specified and directedNote : MS Clamp, nut-bolts and washers shall be measured separately. |
| 30 | Supply and fix eye hook with clamp of required size suitable for 16-95 Sqmm size neutral conductor, made of galvanized steel complete all as specified.Note : MS Clamp, nut-bolts and washers shall be measured separately. |
| 31 | Supply and fix fire retardant engineering thermoplastic (PC) three phase Distribution box of size not less than 275x310x210mm IP65 rated, with spring loaded busbar connection with a provision of 01 No main incomer and 02 Nos outgoing cable connections including fixing with MS clamps, nut-bolts and washers complete all as specified.Note : MS Clamp, nut-bolts and washers shall be measured separately. |
| 32 | Labour only for tightening, stringing of ACSR conductor or aerial bunched (AB) cable of any size for LT over head lines on poles including taking down the aerial bunched cable for repair, testing and commissioning complete all as specified. |
| 33 | M&L GI tubing light grade 80mm dia with all fitting laid in trenches across the road or in culvert or fixed to pole for cable protection complete all as specified. |
| 34 | M&L GI tubing light grade 50mm dia with all fitting laid in trenches across the road or in culvert or fixed to pole for cable protection complete all as specified. |
| 35 | M&L GI tubing light grade 40mm dia with all fitting laid in trenches across the road or in culvert or fixed to pole for cable protection complete all as specified. |
| 36 | Labour only for repair of LT feeder pillar/ panel cubical type 3 phase 4 wire, 415 volts, 50 HZ, AC supply system as per latest IS/IEC standards & regulations, made out of CRCA sheet steel of 3mm thick for outer shell and 2mm thick for inner shell with front and rear openable single/double door. Rate for this item shall include :-(i) checking of UNSV Voltmeter, Ammeters, CTs & control wiring of the panel.(ii) Rewiring of UNSV control wiring of panel as per requirement by 1.5sqmm, 2.5sqmm or 4 Sqmm copper wire.(iii) Re-fixing of panel doors by welding hinges complete.(iii) Making necessary connection with suitable size lugs of incoming and outgoing cables.(iv) Testing and commissioning of LT panel after repair work complete all as specified. |
| 37 | Supply and fix in replacement of ammeter three phase 96x96/144x144mm square type, digital 0-400 Amp complete all as specified. |
| 38 | Supply and fix in replacement of voltmeter three phase 96x96/144x144mm square type, digital 0-500 Volts complete all as specified. |
| 39 | Supply and fix in replacement of CTs of suitable range (100/5,200/5 ratio) with making necessary connection and testing complete all as specified. |
| 40 | Supply and fix in replacement of 3 Pole power contactor with 1 NO & 1 NC & of capacity range 9-30 Amp with making necessary connection and testing complete all as specified. |
| 41 | Supply and fix in replacement of Time switch FM1 / Quartz daily 240 V AC Base/DIN mounting with making necessary connection and testing complete all as specified. |
| 42 | Supply and fix in replacement of 03 Nos of 600 Amp rating & 01 No of 400 Amp rating electrolytic Aluminium bus bars of high conductivity and proper insulated with Red, Yellow, Blue & Black colour respectively and fixing Aluminium bus bars on porcelain support in existing LT panel including making all necessary connections, testing and commissioning complete all as specified. |
| 43 | Supply and fix MCCB of capacity 63 Amp 3/4 pole, 415 V, 50 Hz 16 KA with adjustable thermal and adjustable magnetic protection release to existing LT panel board, making all connections including suitable lugs, testing commissioning including taking out UNSV MCCBs by disconnecting all electrical connection on existing position from LT Panel board and complete all as specified.Note : MCCBs shall be fixed in existing panel and of same type and size as per site requirement. |
| 44 | All as per item No 43 above as but MCCB 100 Amp 3/4 pole, 415 V, 50 Hz 16 KA. |
| 45 | All as per item No 43 above as but MCCB 125 Amp 3/4 pole, 415 V, 50 Hz 16 KA. |
| 46 | All as per item No 43 above as but MCCB 160 Amp 4 pole, 415 V, 50 Hz 16 KA. |
| 47 | All as per item No 43 above as but MCCB 200 Amp 4 pole, 415 V, 50 Hz 25 KA. |
| 48 | All as per item No 43 above as but MCCB 250 Amp 4 pole, 415 V, 50 Hz 25 KA. |
| 49 | All as per item No 43 above as but MCCB 400 Amp 4 pole, 415 V, 50 Hz 25 KA. |
| 50 | Excavation in trenches soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5mtr in depth for foundation etc or for cables / GI tubings etc. not exc 10sqmm on plan and not exceeding 1.5mtr in depth and getting out complete all as specified. |
| 51 | Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in 25mm thick layer complete all as specified and as specified. |
| 52 | Removal of surplus excavated soil to a distance exc50 m but not exc in 100 m and deposited where directed at a level n exc 50 m above the starting point complete all as specified. |
| 53 | Material & Labour for Sand cushioning (dry sand) to under ground cable for cable protection provided with layers 8cm thick before laying and 15cm thick after laying the cable and punned down to 18 cm thickness complete all as specified and directed. Note : For payment purpose, punned thickness of 18cm shall be measured against spread thickness of 23cm as mentioned in para19.75 of SSR Part-I, 2009. |
| 54 | Supply and laying sub class B bricks old size for protection of cables laid lengthwise perpendicular to the axis of cable, adjacent to each other complete all as specified. |
| 55 | Labour only for dismantling and taking down street light for repair or replacement of burnt /worn out accessories or carrying to MES store for issuing under schedule of credit complete all as specified. |
| 56 | Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics, suitable for 40 mm pipe complete with IP 65/66 protection complete all as specified. |
| 57 | Supply and fixing LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics, suitable for 40 mm pipe complete with IP 65/66 protection complete all as specified. |
| 58 | Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver including clamp for fixing as required complete all as specified and directed. |
| 59 | S&F in replacement of bracket made out of 40 mm bore light grade GI pipe bent to shape fixed as bracket suitable for street light fittings not less than 1.2 m long bent/welded to shape including necessary nut, bolt and clamp-02 No made of MS flat 40x5mm as required duly painted by unscrewing nut and bolts complete all as specified. |
| 60 | M&L for 1100 volts grade heavy duty cable with PVC insulated aluminium solid / stranded conductor served with an inner sheathing of PVC tape armoured with overall PVC sheathed 3 core x 1 Sqmm nominal cross sectional area including taking down unserviceable cable complete all as specified. |
| 61 | Labour only for dismantling steel tubular pole any size |
| 62 | Supply and erection, in truly vertical position LT Steel tubular swaged pole complete with cast iron base plate finial taper plug, bolt , nut and screwed type 410 (SP-31) 09 mtrs long Class -10 including painting of poles with two coats of synthetic enamel paint in black and white strips upto 1.5 mtr height from coping over a coat of red oxide primer including numbering of poles complete all as specified and directed. (Note : PCC, Earth work and MS work as cross arms clamps etc shall be measured and paid separately under relevant item) |
| 63 | M&L for PCC 1:3:6 type C-2 using 40mm graded aggregate as in foundation/ for stay assembly etc. all as specified and directed |
| 64 | M&L for PCC 1:4:8 type D2 using 40mm graded aggregate as in foundation/ for pole etc. all as specified and directed. |
| 65 | M&L for cement concrete type B2, 1:2:4 using 20mm graded aggregate for coping etc complete all as specified and directed |
| 66 | M&L for painting to steel tubular poles 9 m long including cross arms, street light brackets, earth pipe, clamps with one coat of aluminium paint including preparation of old painted surfaces properly and providing 3 bands /straps 25 cm wide with paint red signal post office colour and 2 band 25 cm wide with white synthetic enamel paint 300 mm apart from plinth block and numbering of poles 100 mm height with white paint in black box of size 125x125mm, complete all as specified and directed. |
| 67 | Cutting/ Trimming the tree branches touching/ embracing the OH line of LT up to 1.5 Mtr on both side of the OH line & upto 1.5 RM above the over head line including removing the same from site to a distance not less than 250 Mtr away complete all as specified and directed. including providing T&P where required.Note:- Distance between two pole considered as one span. |
| 68 | Labour only for repair of burnt out/perished cable ends 4 Nos each on incoming and outgoing feeders of panels equipment and other machinery by removing burnt ends including cleaning and preparing the cable ends including making necessary connection with suitable size of cable lugs of any size with R, B, Y, N colour code complete all as specified and directed. |
| 69 | Supply, installation, testing and commissioning LT 415 volt, 4 wire AC 50Hz cubical panel factory made outdoor (KIOSK) floor mounted type, weather and vermin proof fabricated from angle of size 50x50x6.0mm and 3.00mm thick MS black sheet, powder coated inside and outside with approved paint over a coat of red oxide primer locking arrangement comprising 50mm godrej type pad lock with duplicate key, two earth terminal, suitable cable glands for incoming and all outgoing cables including grouting KIOSK on floor (60cm above the ground surface) in floor angel iron 50x50x6mm imbeded to fixed the KIOSK with nut bolt, floor PCC (1:2:4) type B1 using 20mm grade stone aggregate complete all as specified and directed by EIC including consisting of following accessories and components:(i) Incoming- MCCB 4P, 200 Amp, 10kA capacity, adjustable thermal and fixed magnetic setting type - 01 No.(ii) Outgoing- (a) MCCB 4P, 100 Amp, 10kA capacity, adjustable thermal and fixed magnetic setting type - 01 Nos (b) MCCB 4P, 63 Amp, 10kA capacity, adjustable thermal and fixed magnetic setting type - 03 Nos (c) MCCB 4P, 40 Amp, 10kA capacity, adjustable thermal and fixed magnetic setting type - 02 Nos (iii) Volt meter (0-500V) three phase, digital type with selector switch -01 No . (iv) Ammeter(0-500A) three phase, digital type with selector switch with suitable capacity of CTs - 01 set. (v) ON/OFF indication lamp with toggle switch- Set of 03.(vi) 4 Nos electrolytic Aluminium bus bars of high conductivity proper insulated of 1½ times of the incoming capacity with provision of extension and mounting on porcelain support.(vii) Internal or control wiring of feeder pillar with suitable size cables including thimbles etc. |
| 70 | Supply, installation, testing and commissioning Street light timer panel LT 415 volt, 4 wire AC 50Hz cubical panel factory made outdoor (KIOSK) floor mounted type, weather and vermin proof fabricated from angle of size 30x30x5.0mm and 3.00mm thick (outer shall) MS black sheet, 2.00mm thick inner shall, duly spray painted with powder coated paint, suitable locking arrangement, two earth terminals, internal or control wiring with suitable size PVC insulated copper conductor cables, suitable cable glands for incoming and all outgoing cables including grouting KIOSK on floor (60cm above the ground surface) in floor angel iron 50x50x6mm imbeded to fixed the KIOSK with nut bolt, floor PCC (1:2:4) type B1 using 20mm grade stone aggregate complete all as specified including arrangement of operation both in auto and manual mode and consisting of following accessories and components:(i) Incoming- MCCB 4P, 63 Amp, 10kA capacity, adjustable thermal and fixed magnetic setting type.(ii) Outgoing- (a) MCCB 4P, 40 Amp, 10kA capacity, adjustable thermal and fixed magnetic setting type. (iii) ON/OFF indication lamp with toggle switch- Set of 03.(iv) 3 Pole power contactor with 1 NO & 1 NC & of capacity range 9-30 Amp(v) Time switch FM1 / Quartz daily 240 V AC Base/DIN mounting.(vi) 3 way selector switch for manual ON/OFF/AUTO switching of street light luminaries |
| 71 | Demolition of cement concrete (un-reinforced) any description and laid in any position complete all as specified and directed. |
| 72 | Labour only for repair of APFC panel cubical type 3 phase 4 wire, 415 volts, 50 HZ, AC supply system as per latest IS/IEC standards & regulations, made out of CRCA sheet steel of 3mm thick for outer shell and 2mm thick for inner shell with front and rear openable single door. Rate for this item shall include :-(i) checking of UNSV MCBs, contactors & capacitors.(ii) taking down / disconnecting the UNSV MCBs, contactors & capacitors.(iii) Rewiring of UNSV control wire of APFC panel as per requirement by 2.5sqmm, 4sqmm or 6 Sqmm copper wire.(iv) Testing and commissioning the APFC panel after repair work complete as directed by Engr-in-Charge. |
| 73 | Supply & fix three phase capacitor duty contactor 5KVAr Make : L&T/Havells/Schneider |
| 74 | Supply & fix three phase capacitor duty contactor 10KVAr Make : L&T/Havells/Schneider |
| 75 | Supply & fix capacitors 15 KVAR Make : L&T/Havells/Schneider |
| 76 | Supply & fix APFC controller for contactor switching with 1 CT input and 144X144 size all as specified and directed. |
| 77 | Supply & fix MCBs Four Pole 415Volt, 16 to 32 Amp 10kA, 'B' curve type |
| 78 | Supply & fix MCBs Four Pole 415Volt, 40 to 100 Amp 10kA, 'B' curve type |
| 79 | Labour only for repair of Solar Street light system by cleaning the solar photovoltaic module (SPV) panel, checking the battery system by measuring the battery gravity and electrical connections of solar charge controller and replacing the unserviceable accessories complete for making the serviceable the Solar Powered LED Street light system complete all as directed by Engr-in-Charge.Note : (i) Spare parts (accessories) shall be measured and paid separately. |
| 80 | Labour only for transporting the solar powered discharged battery from site to workshop for charging and return back the same after full charging of battery as directed by Engr-in-Charge. |
| 81 | Solar street light 40 watt and more all in one with lithium ferro phosphate battery, solar panel and charger inbuilt with bracket all as specified and directed. |
| 82 | Supply & fix 36 Watt solar street light suitable for existing panel all all as specified and directed. |
| 83 | Supply & fix 12 volt 150 Ah Solar powered Battery. |
| 84 | Supply & fix MPPT solar charge controller generation - 5LV-12V, 24V, 36V, 48V in 100A model. |
| 85 | M & L for cutting the road as per requirement upto depth 35 cm and width 30 Cm to lay the GI pipe complete all as specified and directed. |
| 86 | Supply and fix bus bar chamber suitable for three phase supply IP 43 ,with 03 Nos alunimium bus bar for 3 phase ,01 aluminium bus bar for neutral of rating 200 Amp all as specified and directed . Thickness sheet should not less than 3 mm thick Bus bar chamber with one incoming and 4 out going all as specified and directed |
| 87 | M&L GI tubing light grade 100mm dia with all fitting laid in trenches across the road or in culvert or fixed to pole for protection of cables complete all as specified. |
| 88 | M&L for disconnecting the transformer of capacity upto 315 KVA from the electrical system, taking out and shifting the same for repair to workshop, drain out old transformer oil, opening the top cover of the transformer with conservator and taking out core with limbs and primary & secondary windings after the disconnecting and removing iron core, removing damaged primary & secondary windings etc. re-assembling transformer winding and core heating including insulating and packing material in order to take out all moisture from the transformer assembly complete, lowering the core assembly with winding in transformer body, connection work and re-assembling in position top cover, conservator, breather with relay control wiring complete including transportation of transformer back from workshop to site, installation of transformer on foundation, commissioning and testing complete all as specified and directed by Engr-in-Charge. |
| 89 | M&L for copper wire complete as per existing gauge for existing numbers of turns for LV coil/leg rewinding of transformer capacity 63-315 KVA complete all as specified. |
| 90 | M&L for copper wire complete as per existing gauge for existing numbers of turns for HV coil/leg rewinding of transformer capacity 63-315 KVA complete all as specified. |
| 91 | M&L for gasket set made out of cork sheet cut into shape sticking on transformer body with adequate quantity of adhesive to make the complete transformer body leak proof complete all as specified. |
| 92 | Topping up and replacement of old transformer oil with new transformer oil in the existing transformer 11/0.433 KV for topup or to achieve the required level after centrifuging by the centrifuging machine. |
| 93 | Supply and fix in replacement of silica gel pot filled with fresh dehydrating agents (Silica gel) and oil in bowl suitable for transformer of cap 63-160 KVA, 11/0.433 KV transformer outdoor/indoor type complete all as specified. |
| 94 | Supply and fix in replacement of silica gel pot filled with fresh dehydrating agents (Silica gel) and oil in bowl suitable for transformer of cap 200-315 KVA, 11/0.433 KV transformer outdoor/indoor type complete all as specified. |
| 95 | S&F in replacement of LT bushing (Brass stud and bolts with poreclien insulator) suitable size to fixed the transformer capacity range 63-160 KVA, 11/0.433 KV including replacement of gasket, cable glands etc to make the transformer leak proof all as specified. |
| 96 | S&F in replacement of LT bushing (Brass stud and bolts with poreclien insulator) suitable size to fixed the transformer capacity range 200-315 KVA, 11/0.433 KV including replacement of gasket, cable glands etc to make the transformer leak proof all as specified. |
| 97 | S&F in replacement of HT bushing (Brass stud and bolts with poreclien insulator) suitable size to fixed the transformer capacity range 63-315 KVA, 11/0.433 KV including replacement of gasket etc to make the transformer leak proof all as specified. |
| 98 | Paining of HT steel pole 11 mtr long including painting of MS work like crass arms, clamps, pipe channel, bracing etc after cleaning and preparation of surface, painting externally above painting depth with one coat of alumunium paint including 30cm width of circular band 3 Nos alternative upto 1 Mtr height from pole copping with red paint and writing pole No complete all as specified. |
| 99 | Dismantling cross-arms of M.S. channel or angle sections etc. complete and depositing to MES store yard complete all as specified. |
| 100 | M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified. |
| 101 | Dismantling air break gang operated switches vertical/horizontal mounted including insulators and operating mechanism for repair/ replacement of broken/worn out components and insulators etc. or depositing to MES store complete all as specified. |
| 102 | Supply, installation, commissioning and testing of switch air break gang operated HT 11KV grade triple pole with 12 insulator 200Amp rating with drop out fuse assembly with fuse carrier fuse element mounted on insulator and fitted on steel frame mechanically operated mechanism from ground level consisting of operating rod 25mm bore light grade GI pipe to suitable length work from ground level consisting of operation rod 25mm bore. |
| 103 | Supply, laying, testing and commissioning XLPE insulated, screamed, PVC graded galvanized steel strip are wire armoured electric power cable (heavy duty) with alumunium conductor 11000 volts, grade cross section 3 core 95 Sqmm complete all as specified. |
| 104 | S&F CI cable path indicator, voltage written on IT and fixed on angle iron, shall be painted brown for HT cables or yellow for LT cables complete all as specified. |
| 105 | Supply and fixing cable jointing kit for 11KV (Earthed) Grade cable for in door termination heat shrink type joint complete with jointing material and accessories suitable for three core XLPE armoured alumunium conductor cable of size 95Sqmm |
| 106 | Supply and fixing cable jointing kit for 11KV (Earthed) Grade cable for out door termination heat shrink type joint complete with jointing material and accessories suitable for three core XLPE armoured alumunium conductor cable of size 95Sqmm |
| 107 | Supply and fixing cable jointing kit for 11KV (Earthed) Grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for three core XLPE armoured alumunium conductor cable of size 95Sqmm |
| 108 | S&F lightening arrestor expulsion type suitable for 11000 volts complete with all fittings, transmission class, discharge capacity 65kilo Amp including taking down/out old unserviceable LA complete all as specified. |
| 109 | Labour only for dismantling insulators any type, any size |
| 110 | M&L for pin type, porcelain, vitreous, white, brown or green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 150mm height, 150mm dia for 550 volts grade complete all as specified. |
| 111 | M&L for disc type, porcelain, vitreous white, brown or green insulator 145mm high and 255mm dia ball and socket type, single disc assembly for tension with tension clamps for conductors, working pressure 11000 volts complete all as specified. |
| 112 | Labour only for dismantling steel poles/ struts, any size complete all as specified. |
| 113 | M&L for steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11 meters long), staying the poles in a truly vertical position including painting steel tubular pole exposed surface with two coats of aluminium paint over a coat of red oxide primer and providing 3 bends/ straps with paint red signal post colour and two bends with black synthetic enamel paint 300 mm apart from plinth block and numbering of pole and painting embedded portion of pole with one coat of bituminous paint complete all as specified.Note: Earth work, PCC and MS work as cross arms clamps etc shall be measured and paid separately under relevant item |
| 114 | Cutting / Trimming the tree branches touching/ embracing the OH line of HT up to 1.5 Mtr on both side of the OH line & upto 1.5 RM above the over head line including removing the same from site to a distance not less than 250 Mtr away complete all as specified including providing T&P where required. Note:- Distance between two pole shall be measured as one span. |
| 115 | Unbinding ACSR conductor of any type from insulators and re-fixing the same on insulators of HT poles after tightening/ re-stretching to achieve the permissible sag in between spans with and including 2mm dia aluminium binding wire complete all as specified.Note :- Distance between two poles shall be measured as one span. |
| 116 | S&F cradles, hexagonal/ rectangular, fabricated with galvanized steel wire 3.15 or 4mm dia including dismantling of old wire complete all as specified. |
| 117 | Cutting of bushes/ grass, unwanted veg growth in and around the electrical installations, transformers, panel boards, HT 4 pole / 2 pole structures, HT electric poles, etc in complete station and disposed off to the location not less than 50 Mtr all as required at site complete all as specified. |
| 118 | M&L for painting to 2 poles structure of 11 mtr long steel tubular pole including cross arms, channel bracing, earth pipe, anti climbing device, clamps, GOD insulators mounting channels, with one coat of aluminium paint including preparation of old painted surfaces properly and providing 3 bands/ straps 25 cm wide with paint red signal post office colour and 2 band 25 cm wide with white synthetic enamel paint 300 mm apart from plinth block and numbering of poles 100 mm height with white paint in black box of size 125x125mm complete all as specified.Note:-(i) HT tubular pole shall be 11 m long.(ii) All T&P should be provided by contractor. |
| 119 | all as per item No 118. but painting for four pole structure. |
| 120 | all as per item No 118. but painting for Six pole structure. |
| 121 | Maintenance and complete overhauling of 11 KV VCB of existing make/ type/ mode/ capacity including disassembling of operating mechanism parts well cleaning with petrol and CRC-226 and replacing unserviceable spare parts reassembling of parts including well cleaning the complete panel board, main bus bar, decarbonizing all joints bus bar CTS, PTS, spouts metal parts and making VCB perfect operating in manual and electric mode and calibration & checking of tripping system of 11 KV circuit breaker through IDMT over current and earth fault relay at plug setting by primary current injection method to ensure proper function of trip coil control circuit etc. during fault condition setting by expert from authorized agency of state electricity board including submission of calibration certificate complete all as specified.Note:- Spare parts required to make VCB functional shall be measured and paid separately under respective items. |
| 122 | Supply only Breaker control switch 10A 660V |
| 123 | Supply only Closing coil |
| 124 | Supply only Tripping coil |
| 125 | Supply only Vaccum interrupter bottle module with ceramic housing as same as existing or approved by GE/ suitable for outgoing VCB of 400 Amp rating |
| 126 | Supply only Red,Yellow, Blue phase indicator neon light. |
| 127 | Supply only contactor for 630 Amp VCB complete all as specified |
| 128 | Supply only master trip relay of VCB complete all as specified. |
| 129 | Supply and fix 3 Phase Over Current + Earth Fault Relay as per sample at site complete all as specified . |
| 130 | Supply and fixing Multi functional meter for VCB all as specified and directed. |
| 131 | M&L for Earthing complete with galvanized steel earth plate electrode 60 × 60cm × 6mm thick, buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanized iron strip 25×4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel protected by 40 mm bore GI pipe (medium grade) all as shown in electrical plate No. 3, connected to earthing test point all as specified or indicated including concrete pit in PCC (1:3:6) type C1, precast RCC (1:2:4) type B1 cover slab 40x40 Cm x 6Cm reinforced with 8 mm dia deformed bar @ 5 cm c/c with one handle for lifting made out of 8 mm dia MS bar, funnel, wire mesh, 20 mm bore GI pipe (medium grade) for watering including charcoal and salt in alternative layers necessary excavation and earth work in any type of soil and testing complete all as shown on electrical plate No-3 of SSR part-I, 2009. |
| 132 | M&L for earthing complete with galvanized steel earth plate electrode 600x600x6.3 mm thick, buried directly in ground (earth pit not less then 2.25 meters deep below ground level) with top edge of the plate not less then 1.5 meters below normal ground level, connected to galvanized earth wire 4.0 mm dia by means of bolts, nuts, cheek nuts and washers of galvanized or iron protected by 15 mm bore GI pipe (medium grade) and connected to main switch board as directed including concrete pit in PCC (1:3:6) type C1 precast RCC (1:2:4) type B1 cover slab 40x40 Cm x 6Cm reinforced with 8 mm dia deformed bar @ 5 cm c/c with one handle for lifting made out of 8 mm dia MS bar, funnel, wire mesh, 20 mm bore GI pipe (medium grade) for watering including charcoal and salt in alternative layers necessary excavation and earth work in any type of soil and testing complete all as shown on electrical plate No-3 of SSR part-I, 2009. |
| 133 | Supply and fix LED bollard 10 watt sturdy IP 65 with excellent light all as specified and directed. |
| 134 | Supply and fix one hole lugs aluminium 25 to 35 Sqmm size all as specified and directed |
| 135 | Supply and fix one hole lugs aluminium 50 to 70 Sqmm size all as specified and directed |
| 136 | Supply and fix one hole lugs aluminium 95 to 120 Sqmm size all as specified and directed |
| 137 | Supply and fix one hole lugs aluminium 240 Sqmm size all as specified and directed |
| 138 | Supply and fix electric insulating matting class 1 to provide safety against Electric work 1 meter with 2 meter long all as specified and directed. |
| 139 | Dismantling post or struts any section, embedded in concrete etc including taking out embedded portion and making good the disturbed ground complete all as specified and directed. |
| 140 | S&F MS posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 all as spfd and directed |
| 141 | M & L for MS round bars (Fe-410-W (Gde E-250) quality A or Fe-290 (Gde-E-165)) 10mm dia and over cut to Length bent to shape required incl cranking, bending, spirally for hooping for columns with an including MS wire( Annealed not less than 0.90 mm Dia) or securing with clips complete all as specified and directed. |
| 142 | Supply only chain link MS galvanized fencing any size and type complete all as specified and directed. |
| 143 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc., including provision of binding wire complete all as specified and directed. |
| 144 | S & F Galvanized, 2 strand, steel barbed wire 2.24 mm dia., barbed with 2 mm dia., barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings with and provision of galvanized mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and directed. |
| 145 | M&L for 2 coats of synthetic enamel paint over one coat of red oxide on newly prepared steel surface of any description ,not otherwise description over 10cm width or girth. |
| 146 | Supply, installation, testing and commissioning LT 415 volt, 4 wire AC 50Hz cubical panel factory made outdoor (KIOSK) floor mounted type, weather and vermin proof fabricated from angle of size 50x50x6.0mm and 3.00mm thick MS black sheet, powder coated inside and outside with approved paint over a coat of red oxide primer locking arrangement comprising 50mm godrej type pad lock with duplicate key, two earth terminal, suitable cable glands for incoming and all outgoing cables including grouting KIOSK on floor (60cm above the ground surface) in floor angel iron 50x50x6mm imbedded to fixed the KIOSK with nut bolt, floor PCC (1:2:4) type B1 using 20mm grade stone aggregate complete all as specified and directed by EIC including consisting of following accessories and components:(i) Incoming- MCCB 4P, 350 Amp, 10kA capacity, adjustable thermal and fixed magnetic setting type - 01 No.(ii) Outgoing- (a) MCCB 4P, 160 Amp, 10kA capacity, adjustable thermal and fixed magnetic setting type - 02 Nos (b) MCCB 4P, 125 Amp, 10kA capacity, adjustable thermal and fixed magnetic setting type - 01 Nos (c) MCCB 4P, 100 Amp, 10kA capacity, adjustable thermal and fixed magnetic setting type - 01 Nos (d) MCCB 4P, 63 Amp, 10kA capacity, adjustable thermal and fixed magnetic setting type - 01 Nos (e) MCCB 4P, 40 Amp, 10kA capacity, adjustable thermal and fixed magnetic setting type - 01 Nos (iii) Volt meter (0-500V) three phase, digital type with selector switch -01 No . (iv) Ammeter(0-500A) three phase, digital type with selector switch with suitable capacity of CTs - 01 set. (v) ON/OFF indication lamp with toggle switch- Set of 03.(vi) 4 Nos electrolytic Aluminium bus bars of high conductivity proper insulated of 1½ times of the incoming capacity with provision of extension and mounting on porcelain support.(vii) Internal or control wiring of feeder pillar with suitable size cables including thimbles etc. |
| 147 | M &L Loose filling with aggregates of broken stone or bouldersof gauge 40 to 80 mm in four/ six pole structure. Note - Before depositing, the aggregates should be cleaned and washed with water. |
| 148 | Taking up or down 150 mm dia bore GI tubing with all connections including cutting and segregating serviceable part for re-fixing and removing UNSV part to store complete all as specified and directed.Note: Earth work will be measured and paid separately |
| 149 | All as per item No. 148 above but GI tubing 100 mm dia bore |
| 150 | All as per item No. 148 above but GI tubing 80 mm dia bore |
| 151 | All as per item No. 148 above but GI / HDPE tubing 50 mm dia bore |
| 152 | All as per item No. 148 above but GI tubing 25 mm dia bore |
| 153 | All as per item No. 148 above but GI tubing 20 mm dia bore |
| 154 | All as per item No. 148 above but GI tubing 15 mm dia bore |
| 155 | Re-fixing only old serviceable GI tubing of 150mm dia bore including cleaning and rerunning the old screw threads & laying in trenches or on floors complete all as specified and directed. |
| 156 | All as per item No. 155 above but for GI tubing of 100 mm dia bore. |
| 157 | All as per item No. 155 above but GI tubing of 80 mm dia bore. |
| 158 | All as per item No. 155 above but GI tubing of 50 mm dia bore. |
| 159 | All as per item No. 155 above but GI tubing of 25 mm dia bore. |
| 160 | All as per item No. 155 above but GI tubing of 15/20 mm dia bore. |
| 161 | Supply, fixing & laying 150 mm dia bore GI tubing, medium grade with and including all fittings and fixture like socket, nipple, elbow, reducer etc complete laid in trenches or laid in floor complete all as specified and directed. |
| 162 | All as per item No. 161 above but GI tubing 100 mm dia bore |
| 163 | All as per item No. 161 above but GI tubing 80 mm dia bore |
| 164 | All as per item No. 161 above but GI tubing 50 mm dia bore |
| 165 | All as per item No. 161 above but GI tubing 25 mm dia bore |
| 166 | All as per item No. 161 above but GI tubing 20 mm dia bore |
| 167 | All as per item No. 161 above but GI tubing 15 mm dia bore |
| 168 | Supply and fix of GI bend of any angle, not exceeding 1.5 mtr length, suitable for the 150 mm dia of GI pipe complete all as specified and directed |
| 169 | Supply and fix of GI bend of any angle, not exceeding 1.5 mtr length, suitable for the 100 mm dia of GI pipe complete all as specified and directed |
| 170 | Supply and fix of GI bend of any angle, not exceeding 1.5 mtr length, suitable for the 80 mm dia of GI pipe complete all as specified and directed. |
| 171 | Rubber or fiber board gaskets for flanged ends suitable for 150mm dia GI pipe complete all as specified and directed. |
| 172 | Rubber or fiber board gaskets for flanged ends suitable for 100mm dia GI pipe complete all as specified and directed. |
| 173 | Rubber or fiber board gaskets for flanged ends suitable for 80mm dia GI pipe complete all as specified and directed. |
| 174 | Supply & fix HDPE flexible pipe 50mm dia bore PE 100 , 3 to 3.4 mm wall thick PN 6 of capacity 4 kg/cm2 black in colour as sample kept with AGE office including all fittings and fixtures for jointing for water supply purpose from intake point of source to existing pipe line all as required at site and complete all as specified.Note : These pipe shall be laid during summer season in Gad-Gad or Galati nallah which is 6-7 KM away from MES Office. Please Enable Macros to View BoQ information |
| 175 | Supply & fix HDPE flexible pipe 50mm dia bore PE 100 , 3 to 3.4 mm wall thick PN 6 of capacity 4 kg/cm2 black in colour as sample kept with AGE office including all fittings and fixtures for jointing for water supply purpose from intake point of source to existing pipe line all as required at site and complete all as specified.Note : These pipe shall be laid during summer season in Gad-Gad or Galati nallah which is 6-7 KM away from MES Office. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail