| 1 | Taking down plaster in cement mortar on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc. in shafts area including all necessary scaffolding, etc as required complete all as specified and directed.Note: Work shall be carried out in bldgs with height upto 12 Storey. |
| 2 | M&L for 15 mm thick rendering on fair faces of brick work in cement mortar (1:6) and finished the surfaces even and smooth without using extra cement complete all as specified and as directed. |
| 3 | M&L for 5mm thick rendering in CM (1:3) on concrete surfaces as in ceilings and finishing the surfaces even and smooth without using extra cement. complete all as specified and as directed. |
| 4 | M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar (1:4) and finishing the surface even and smooth with applying WPC in shaft area incl scaffolding complete all as specified and directed.Note: (i) Note: Work shall be carried out in bldgs with height upto 12 Storey.(ii) WPC will be measured and paid separately |
| 5 | Supply only liquid water proofing compound complete all as specified and directed. |
| 6 | Preparation of newly plaster surfaces of ceiling surface and M&L for applying three coats white wash on walls complete all as specified and directed. |
| 7 | Preparation of newly plaster surfaces of walls and M&L for applying two coats of Acrylic washable distemper over & including a coat of primer complete all as specified and directed. |
| 8 | Preparation on new plastered surfaces of walls and M&L for applying two coats of cement base paint over including a coat of primer complete all as specified and directed.Note: Work shall be carried out in bldgs with height upto 12 Storey. |
| 9 | Preparation of old decorated surfaces by complete removal of existing treatments by brooming down or steel wire brushing scrapping down smoke soot and greasy spots and M&L for applying two coats of cement base paint on walls complete all as specified and directed.Note: Work shall be carried out in bldgs with height upto 12 Storey. |
| 10 | Complete removal of old decorated surfaces by brooming down or steel wire brushing, scrapping down smoke soot, moulds, etc and M&L for applying one coat of cement base paint on walls complete all as specified and directed.Note: Work shall be done in bldgs with height upto 12 Storey. |
| 11 | Preparation of old plastered surfaces and M&L for applying one coat of oil bound distemper on walls complete all as specified and as directed. |
| 12 | Complete removal of existing treatment and M&L for applying two coats of Oil Bound Distemper over & including a coat of primer on walls complete all as specified and directed. |
| 13 | M&L for applying 2mm thick wall care putty on walls/ ceilings complete all as specified and as directed. |
| 14 | Preparation of old plastered surfaces and M&L for applying one coat of interior emulsion paint on walls complete all as specified and as directed. |
| 15 | Preparation of old decorated surfaces by brooming down or steel wire brushing, scrapping down smoke soot, moulds,etc and M&L for applying one coat of anti-algae and anti-fungal exterior grade weather coat paint complete all as specified and directed.Note: Work shall be carried out in bldgs with height upto 12 Storey. |
| 16 | Preparation of old decorated surfaces by brooming down or steel wire brushing, scrapping down smoke soot, moulds,etc and M&L for applying one coat of anti-algae and anti-fungal exterior grade weather coat paint over & including a coat of primer complete all as specified and directed.Note: Work shall be carried out in bldgs with height upto 12 Storey. |
| 17 | Preparation of old decorated surfaces by brooming down or steel wire brushing, scrapping down smoke soot, moulds,et and M&L for applying one coat of white wash on walls complete all as specified and directed. |
| 18 | M&L for french polishing on surfaces of any description width or girth including cleaning and preparing the surface including a coat of wood filler on old works with one or more coats complete all as specified and directed. |
| 19 | Preparation of old decorated surfaces by brooming down or steel wire brushing, scrapping down smoke soot, moulds,etc and M&L for applying one coat of white wash on ceilings complete all as specified and directed. |
| 20 | Complete removal of old decorated surfaces by brooming down or steel wire brushing, scrapping down smoke soot, moulds,etc and M&L for applying two coats of indigo weather coat paint / floor paint complete all as specified and directed.Note: Work shall be carried out in bldgs with height upto 12 Storey. |
| 21 | Preparation of old steel surfaces of any description over 10 cm width or girth and M&L for applying one coat of synthetic enamel paint complete all as specified and directed. |
| 22 | Preparation of old wooden surfaces of any description over 10 cm width or girth and M&L for applying one coat of synthetic enamel paint complete all as specified and directed. |
| 23 | Removal of plants, shurbs, weeds upto 4.5 ft height complete incl roots dia n.exc 25mm on chajja/ shaft/ masonry at any height incl applying root killer poeder(copper sulphate) as per manufacturers instructions including all necessary scafolding as per requirement for execution of work with safety precautions and removal of rubbish/ spoils outside MoD land/area complete all as specified and directed.Note: Work shall be carried out in bldgs with height upto 4 Storey. |
| 24 | All as per BOQ Serial item No 23 above but above 5 to 8 storey of building complete all as specified and directed. |
| 25 | All as per BOQ Serial item No 23 above but above 9 to 12 storey of building complete all as specified and directed. |
| 26 | All as per BOQ Serial item no 23 above but roots of dia exc 25mm upto 50mm complete all as specified and directed. |
| 27 | All as per BOQ Serial item No 26 above but above 5 to 8 storey of building complete all as specified and directed. |
| 28 | All as per BOQ Serial item No 26 above but above 9 to 12 storey of building complete all as specified and directed. |
| 29 | Preparation of old surface including brooming down or steel wire brushingf, scrapping down smoke shoot, mould, moss and efflorocent salts and trading oil and greasy spots in place remove the vegetation with using root killer powder where vegetation removal to be done upto 4 story bldg including all necessary scafolding as per requirement to execution of work with safty precaution and removal of rubbish/ spoils outside MoD land/area complete all as specified and as directed |
| 30 | All as per BOQ Serial item No. 29 above but above 5 to 8 storey of building complete all as specified and directed. |
| 31 | All as per BOQ Serial item No. 29 above but above 9 to 12 storey of building complete all as specified and directed. |
| 32 | Taking up or down 15mm steel tubing and connections complete all as specified and directed. |
| 33 | Taking up or down 20mm steel tubing and connections complete all as specified and directed. |
| 34 | Taking up or down 25mm steel tubing and connections complete all as specified and directed. |
| 35 | M&L for cutting chases, pinning, in making good to facing where required of of brick wall and pointing in cement motrar 1:3 to ends and cutting chases for concealed water tubing and concealed conduit wiring ete and making good surfaces complete all as specified and directed. |
| 36 | S&F 15mm bore steel tubing medium grade galvanised with all fittings fixed complete to wall and ceiling complete all as specified and directed. |
| 37 | S&F 20mm bore steel tubing medium grade galvanised with all fittings fixed complete to wall and ceiling complete all as specified and directed. |
| 38 | S&F 25mm bore steel tubing medium grade galvanised with all fittings fixed complete to wall and ceiling complete all as specified and directed. |
| 39 | Supplying and laying for 20 mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches/walls including all brass fitting/fixtures in any grade to receive plumbing fittings and fixtures complete all as specified and directed |
| 40 | Supplying and laying for 25 mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches/walls including all brass fitting/fixtures in any grade to receive plumbing fittings and fixtures complete all as specified and directed |
| 41 | Supplying and laying for 32 mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches/walls including all brass fitting/fixtures in any grade to receive plumbing fittings and fixtures complete all as specified and directed |
| 42 | S&F in repairs 20mm bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipes complete all as specified and as directed. |
| 43 | S&F in repairs 25mm bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipes complete all as specified and as directed. |
| 44 | Demolition of Brickwork, quoins, arches, pillars etc but excluding ashlar facings, dressed all stone work and precast concrete articles built in cement mortar complete all as specified and directed. |
| 45 | M&L for brick work with sub class 'B' bricks built in cement mortar 1:6 straight or curved on plan exceeding 6 mtr mean radius complete all as specified and directed. |
| 46 | M&L for brick work with sub class 'B' bricks straight or curved on plan or to any radius in half brick work built in CM (1:4) complete all as specified and directed. |
| 47 | Demolition of cement concrete of any description and in any position not other wise specifically provided for complete all as specified and as directed. Note: Work shall be carried out in bldgs with height upto 4 Storey. |
| 48 | Dismantling bitumenous felt of any type and removal of rubbish/ spoils outside MoD land/area complete all as specified and as directed. Note: Work shall be carried out in bldgs with height upto 12 Storey. |
| 49 | M&L for PCC 1:2:4 type B0 using 12.5 mm graded stone aggregate, as in roof kerbs/pading, with water proofing compound etc complete all as specified and as directed. Note: WPC will be measured and paid seperately. |
| 50 | M&L for Water Proofing Treatment on existing cleaned RCC Roof with the following Specifications and Manufacturer's instructions, complete all as specified and as directed :- (a) Rendering 10mm thick in Cement Mortar 1:4, Plastered Surfaces finished Even and Smooth. The Plastered Surfaces shall be cured properly for 7 Days by Ponding of Water over Roof. (b) Preparing and cleaning of fully dry Plastered Surfaces as per IS:3067-1966. (c) Applying Bitumen Primer conforming to IS-3384-1986 over the Cleaned Plastered Surface @ 0.30 Litre per Sqm. (d) Applying evenly One Coat Blow Hot Bitumen of grade 85/25 @ 1.20 Kg per Sqm on Primed Surfaces. (e) Applying a layer of APP based Polymeric Membrance 3.0mm thick (minimum) weighing 3.50 Kg per Sqm (reinforced) with Polyster Non-woven Fabric weighing not less than 160 Grams per Sqm by Torch application. The Overlaps shall be minimum 100mm on the Transverse direction and 75mm on Longitudinal direction. (f) Applying One Coat of Aluminium Paint @ 0.10 Litre per Sqm over APP based Polymeric MembraneNote: Work shall be carried out in bldgs with height upto 12 Storey. |
| 51 | Dismantling cast iron or re-inforced concrete drain pipes of 100mm bore, jointed in cement mortar complete all as specified and as directed. |
| 52 | Taking down Eaves gutter, rain water pipes (any size and pattern) including all fitting, bends, shoes, swan neck etc inculing cleaning and removing from site etc complelete all as specified and directed. |
| 53 | S&F 110mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall complete all as specified and as directed. |
| 54 | S&F 75mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall complete all as specified and as directed. |
| 55 | S&F 110mm PVC (SWR) bends any radius complete all as specified and as directed. |
| 56 | S&F 75mm PVC (SWR) bends any radius complete all as specified and as directed. |
| 57 | S&F 110mm PVC (SWR) junction with acsses door any radius complete all as specified and as directed. |
| 58 | S&F 75mm PVC (SWR) junction with acsses door any radius complete all as specified and as directed. |
| 59 | S&F CI spun pipes with out ears in any length fixed to wall with brackets of 100mm bore including bitummous paints both side complete all as specified and as directed. |
| 60 | S&F CI bend with door of 100mm bore complete all as specified and as directed. |
| 61 | S&F CI branch pieces single equal or unequal with door of 100mm bore complete all as specified and as directed. |
| 62 | S&F CI 'T' of 100mm bore complete all as specified and as directed. |
| 63 | S&F CI cowl of 100mm bore complete all as specified and as directed. |
| 64 | S&F rotational moulded poly-ethylene water storage tanks of 500 ltr capacity, (cylindrical vertical with closed top) hoisted and fixed in position including dismantling of existing water tank and remove from site complete all as specified and directed. |
| 65 | S&F rotational moulded poly-ethylene water storage tanks of 1000 ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position including dismantling of existing water tank and remove from site complete all as specified and as directed. |
| 66 | S&F 20mm dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed |
| 67 | S&F in repairs 20mm dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed |
| 68 | S&F in repairs 25mm dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed. Please Enable Macros to View BoQ information |