| 1 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres in All kinds of soil |
| 2 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 3 | Supplying and laying including digging, carrying by lorry, filling River Bed Material including watering & consolidation in layers to specified lines, camber, grades and cross sections. Finished work including material , labour all leads , lifts and carriage of material by MT/HL. |
| 4 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) |
| 5 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) |
| 6 | Providing and laying in position specified grade of reinforced cement concrete inclu. curing but excluding the cost of centering, shuttering, finishing & reinforcement. All works upto plinth level 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone agg. 20 mm nominal size) |
| 7 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 8 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 9 | Centring and shuttering including strutting propping etc and removal of form work |
| 10 | Foundations, footings, bases of columns etc. for mass concrete |
| 11 | Suspended floors, roofs, landing, balconies and access platforms. |
| 12 | Providing and laying damp-proof Course 50 mm thick with cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and curing complete. |
| 13 | Brick work with F.P.S. bricks of class designation 75 in foundation and plinth including all shapes, leads, lifts and carriage of material by MT / H.L. in cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 14 | Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level. |
| 15 | 15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 6 ( 1 cement : 6 fine sand). |
| 16 | 12mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 coarse sand) |
| 17 | 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) incl. all lifts, carriage of material by MT/HL. |
| 18 | Finishing walls with acrylic smooth exterior paint of required shade onNew work (Two or more coats applied @ 1.67 liter/10sqm over andincluding priming coat of exterior primer applied @ 2.20kg/10sqm) |
| 19 | Distempering with oil bound washable distemper of approved brand andmanufacture to give an even shade on New work (two or more coats) overand including priming coat with water thinnable cement primer |
| 20 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete. In colour such as White, Ivory, Grey, Fume Red Brown |
| 21 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointingin white cement mixed with pigment of matching shade complete. |
| 22 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mmangle iron and 3mm M.S. gusset plates at the junctions and corners, allnecessary fittings complete, including applying a priming coat of approvedsteel primer. Using flats 30x6mm for diagonal braces and central cross piece |
| 23 | Providing and fixing 30mm wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge : First class kail wood |
| 24 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 25 | Providing and fixing on wall face unplasticized - Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.110 mm diameter |
| 26 | Providing and fixing on wall face unplasticised- PVC moulded fittings/accessories for unplasticised- Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 1 0 mm gap for thermal expansion .- Bend 110mm |
| 27 | Providing and fixing on wall face un-plasticized - PVC mouldedfittings/accessories for un plasticized Rigid PVC rain water pipesconforming to IS : 13592 Type A including jointing with seal ringconforming to IS : 5382 leaving 10 mm gap for thermal expansion. 110 mm shoe |
| 28 | Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggreagate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. |
| 29 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittings complete: 32 mm dia |
| 30 | Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931 |
| 31 | Providing & fixing 15mm nominal bore C.P. brass angle valve for basin mixer and gyser points of approved for conforming to IS : 8931 |
| 32 | Providing and fixing 15 mm nominal bore C.P. stop cock (concealed) of standard design and of approved make conforming to IS : 8931 |
| 33 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover & suitable locking arrangement of Finolex, Sintex or Vectus or equivalent make & making necessary holes for inlet, outlet & overflow pipes but without fittings & the base support for tank |
| 34 | Providing and fixing 15 mm nominal bore C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. |
| 35 | Providing and fixing on PVC pipe 6 kg/ cm2 pressure excluding pvc fittings, jointing wutg adgesive/seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion.Single socketed pipes. |
| 36 | 10 mm dia |
| 37 | 80 mm dia |
| 38 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot and cold water supply, including allCPVC plain and brass threaded fittings. This includes jointing of pipesand fittings with one step CPVC solvent cement and testing of jointscomplete as per direction of Engineer-in-charge. |
| 39 | .15mm nominal outer dia pipes. |
| 40 | 20mm nominal outer dia pipes |
| 41 | Providing and fixing PPR Unions PPR Union 32mm |
| 42 | Providing and fixing CPVC pipe elbow 90 degree |
| 43 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete |
| 44 | 15 mm nominal bore |
| 45 | 20mm nominal bore |
| 46 | Providing and fixing of Soap dish holder with all fittings as per direction of Engineer-in-charge. |
| 47 | Providing and laying PVC soil waste pipe including bed concrete and all around PVC pipe as per standard design (Prince, finolex, supreme make of 4 kg / cm² pressure. 110mm dia. |
| 48 | Providing and fixing PVC plain bend of approved make Supreme/ Finolex/Astral or equilant complete 100mm dia. |
| 49 | 100mm dia. |
| 50 | 160mm dia. |
| 51 | P/F of PVC Floor Trap of approved Quality size 110 mm |
| 52 | 110 mm |
| 53 | 160mm |
| 54 | Providing and fixing C.P Jali of approved make complete 110 mm |
| 55 | Providing and fixing PVC Plain Tee of approved make Supreme/Finolex/Astral or equilant complete 110 mm x 80 mm |
| 56 | Providing and fixing PVC Door Bend of approved make Supreme/Finolex/Astral or equilant complete 110 mm |
| 57 | Providing and fixing PVC Door Tee of approved make Supreme/Finolex/Astral or equilant complete 110 mm |
| 58 | Providing and fixing PVC Coupler of approved make Supreme/Finolex/Astral or equilant complete 110 mm |
| 59 | Providing and fixing PVC Clamps for pvc pipe of approved make complete 110 mm |
| 60 | Providing and fixing PVC Cowl of approved make complete 110 mm |
| 61 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 62 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 63 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with a minimum distance of 37 mm from wall face with concealed fittings arrangements of approved quality and colour, weighing not less than 88 gms. |
| 64 | Add for plaster drip course/grooves in plastered surface or moulding to R.C.C. projections |
| 65 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 gradedstone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. |
| 66 | Wiring for light point, fan point/exaust fan point/call bell point with 1.5 sqmm FRLS PVS insulated copper conductor single core cable in surface/recessed PVC conduit, with modular switch, modular plate, suitable GI Box earthing the point with 1.5 sq. mm Frils PVS insulated copper conductor single core cable etc as required. |
| 67 | Applying synthetic enamel paint of approved brand and manufacture to give and even shade two or more coats on new works including drawing 3d painting like fruits, Animals, plants, alphabet writing, drawing, slogan writing etc as per requirement/approved by authority and as per direction of engineer in charge. |
| 68 | Chequerred precast cement concrete tiles 22mm thick in footpath andcourtyard, jointed with neat cement slurry mixed with pigment to matchthe shade of the tiles, including rubbing, cleaning and curing complete,on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand) . Light shade using white cement |
| 69 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 70 | Providing and laying dry stone agg. Using 40mm nominal size incl. spreading,levelling sand grouting, watering, ramming, etc all complete |
| 71 | carriages of materials by mechinical trancsport incl. loading, unloading and stacking complete |
| 72 | Sand for a lead of 5 kms. |
| 73 | stone agg below 40mm 5 kms |
| 74 | stone agg 40 mm and above 5 kms |
| 75 | Bricks for an avg lead of 5 kms Please Enable Macros to View BoQ information |