| 1 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 2 | Chequerred precast cement concrete tiles 22mm thick in footpath and courtyard, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing, cleaning and curing complete, on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand) . Ordinary cement without any pigment. |
| 3 | sand/stone aggregate below 40 mm nominal size at an avg lead of 30km |
| 4 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 5 | 12mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 fine sand) |
| 6 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over theplastered wall surface to prepare the surface even and smooth complete. 2mm thick |
| 7 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood KD wood and well matched teak face veneers on both faces of shutters. With ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. 30mm thick |
| 8 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. 30mm thick KD WOOD |
| 9 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. |
| 10 | Providing and fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0mm thick glass panes |
| 11 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade, one or more coats on new work including a priming coat of approved brand . |
| 12 | Providing and fixing ISI marked oxidized M.S. tower bolt black finish, (Barrel type) with necessary screws etc complete DOORS |
| 13 | windows 100x10mm |
| 14 | Providing and fixing ISI marked oxidized M.S. Aldrop conforming to IS : 4992 with necessary screws etc. complete : |
| 15 | Providing and fixing ISI marked oxidized M.S. window lock conforming to IS : 4992 with necessary screws etc. complete : |
| 16 | Providing and fixing ISI marked oxidized M.S.handles with necessary screws etc. complete : |
| 17 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer |
| 18 | Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm) |
| 19 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 20 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylenerandom fittings. This includes testing of joints complete as per direction of Engineer-incharge. PN-16 pipe , 25mm OD(SDR-7.4) |
| 21 | Providing and fixing 15 mm nominal bore C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. |
| 22 | Grating (C.I.) 100x100 mm |
| 23 | stainless steel soap case |
| 24 | P/F Tee 100 mm dia PVC of Approved make type B |
| 25 | P/F p trap |
| 26 | P/F collar 75mm |
| 27 | P/F collar 100mm |
| 28 | P/F 100mm pvc pipes |
| 29 | P/F 75mm pvc pipes |
| 30 | P/F elbow 100mm |
| 31 | P/F elbow 75mm |
| 32 | P/F PVC cowel cover over vent pipe of approved |
| 33 | P/f of pipes including cost of unions , sockets etc 25mm nominal bore ( Supply Line 50 Rft) approved brand and manufacture. |
| 34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes i/c ball cock |
| 35 | Earth work in excavation by mamual means in foundation trenches or drains (not exceeding 1.5M in width as well as 10Sqm on plan) including dressing of sides ramming of bottoms lift up to 1.5M including getting out the excavated soil and disposal of surplus excavated soil within a lead of 1 M from edge of cutting. |
| 36 | Supplying and laying of stone soling hand packed tightly including ramming, watering. |
| 37 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. All work up to plinth level.1:4:8 (1Cement: 4 fine sand: 8 graded stone aggregate 40mm nominal Size) |
| 38 | Brick work with FPS bricks of class designation 75 in super structure in cement mortar 1:6 (1 Cement : 6 Coarse sand) (including Extra Brick |
| 39 | 12mm plaster in 1:6 mix |
| 40 | Dry random rubble masonry with hard stone in foundation and plinth: With bond stone. |
| 41 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 42 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level Mild steel and medium tensile steel bars |
| 43 | Centering and shuttering including strutting, propping etc. and removal of form for: suspended floors |
| 44 | Providing and fixing 1st quality ceramic glazed floor tiles conforming toIS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 45 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cementmortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 46 | Providing/hoisting and fixing trusses /purlins/rafters/posts/post plates or like components includings cost of screws etc complete, first class Popular wood |
| 47 | Providing corrugated G. S. sheet roofing including vertical/ curved surface and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape whereever required i/c ridges and hips required as per the truss drawing. 0.40mm thick with zinc coating not less than 275gm/m2 including fixing of plained sheets over ridges and valleys. |
| 48 | sand/aggregates at an vag lead of 20 km |
| 49 | stones at an avg lead of 50 km |
| 50 | ADD COST OF ELECTRICIFICATION |
| 51 | Provision for signboard and photograph Please Enable Macros to View BoQ information |