| 1 | PART-A Survey, Soil Testing and Design Engineering & Cost |
| 2 | Detailed survey & soil investigation of the area within battery limit and submission of report |
| 3 | Design & engineering on Plant and Machineries (Electrical) to be supplied by the Bidder inclusive of Overhead construction cost, Contingencies but excluding GST |
| 4 | Design engineering cost for Civil & Strucrural works |
| 5 | PART-B Civil And Strucrural Works inclusive of Insurance, Contingencies but excluding GST |
| 6 | Main Sub-station Building (As per the NIT and System Requirement) |
| 7 | MPMKVVCL Metering room (As per the NIT and System Requirement) |
| 8 | Outdoor steel structures (As detailed in the NIT) |
| 9 | Foundation of outdoor structures including Transformer foundations (As per the NIT and System Requirement) |
| 10 | Cable Trenches (As per the NIT and System Requirement) |
| 11 | Boundary Wall along with Concertina Coils and gates (As detailed in the NIT) |
| 12 | Surface Dressing (As per the NIT and Site Requirement) |
| 13 | Stone Laying (As per the NIT and Site Requirement) |
| 14 | Anti Weed Treatment (As per the NIT and Site Requirement) |
| 15 | Oil Overflow Chamber with Oil drain pipes (As per the NIT and System Requirement) |
| 16 | Bore well with casing and gravel packing (As per the NIT and System Requirement) |
| 17 | Security Room (As per the NIT and System Requirement) |
| 18 | RCC Sump, Pump House, Water tank and Connection arrangements (As per the NIT and System Requirement) |
| 19 | Shed for Diesel Generator (DG) Set (As per the NIT and System Requirement) |
| 20 | Oil Filtration Room (As per the NIT and System Requirement) |
| 21 | Drain along Boundary Wall (As per the NIT and System Requirement) |
| 22 | Parking Shed (As per the NIT and System Requirement) |
| 23 | Cement Concrete ROAD (5 metre wide) (As per the NIT and System Requirement) |
| 24 | Pathway (3.75 metre wide) (As per the NIT and System Requirement) |
| 25 | PART-C Supply of Plant & Machineries, Erection installation and Commissioning |
| 26 | Isolators 33 kV (nominal), 3 poles, 1250A, 25kA, Motorised , cranking type, OFF- Load Isolators, arrangement for interlocking with 33 kV Vacuum Circuit breaker |
| 27 | Isolators 33 kV (nominal), 3 poles, 1250A,25kA, Motorised , cranking type, OFF- Load Isolators, arrangement for interlocking with 33 kV Vacuum Circuit breaker along with D.O. Fuses and earthing switch |
| 28 | Isolators 33 kV (nominal), 3 poles, 1250A,25kA, Motorised , cranking type, OFF- Load Isolators, arrangement for interlocking with 33 kV Vacuum Circuit breaker with earthing switch |
| 29 | Lightning arrester, station class, 30 kV, 10 kA, suitable for 33 kV supply, solidely earthed (each set consists of 3 Nos.) with counters/surge monitors |
| 30 | Single phase current transformer (CT), outdoor type, 33 kV, 3 cores, CTR as required (each set consists of 3 nos.) |
| 31 | Potential transformer (PT), outdoor type, 33/√3 kV / 110/√3 V, 2 cores, 100 VA for metering and protection each for three phase system |
| 32 | Vacuum Circuit Breaker, 33kV, 1250 A, outdoor type, 750 MVA symmetrical breaking capacity with indoor type remote control panel having IDMTL relay for O/L and E/F protection, ammeter & energy meter etc. |
| 33 | Power transformer, outdoor, plinth mounted, 33/3.3kV, 5.00 MVA, ONAN cooled, DY-11, conforming to IS:2026 (current) having ON - load tap changer on HV side and LV neutral effectively earthed through required value of resistance. (Restricted Neutral System) with all accessories including 33 kV remote control panel for on load tap changer as per IS:3639 (Current) with the rating as given below:- i) Rated KVA:5000 ii)Rated Voltage(primary):33000Viii)Rated voltage Secondary:3300Viv)Connection with Vector group:Dy11 |
| 34 | Neutral Grounding Resistors with Protection for Transformers (33/3.3 kV) |
| 35 | 3.3 kV off-load isolator with earthing switch and arrangement for electrical & mechanical interlocking suitable for outdoor installation, structure mounted,1250 Amps |
| 36 | 3 kV grade, 5 kA lightning arrestor, station class, metal oxide, suitable for 3.3 kV system in outdoor switch yard of substation in set of 3 nos with counters/surge monitors |
| 37 | 3.3 kV switch-board, indoor type, 25 panel, with vacuum circuit brakers 150 MVA symmetrical breaking capacity. All panels will conform to IS:3427 (Current) and relevant parts to IS:2516 ( current). These will be provided with cable entry boxes. The incoming panels will be provided with restricted earth fault protection. All panels will be provided with IDMTL relays for over current and earth fault protection. The incoming and outgoing panels shall be provided with Trivector meters. |
| 38 | Station Transformer, Outdoor type rated as follows:Rated KVA:160Rated Voltage(Primary): 33000VRated Voltage(secondary):415VCu wound, plinth mounted |
| 39 | Lighting Transformer, Outdoor type rated as follows: Rated KVA:100 Rated Voltage(Primary): 33000VRated Voltage(secondary):230V Cu wound, plinth mounted |
| 40 | Power distribution board, 415V, 3 ph and neutral with MCCB/MCB’s for control and distribution of auxiliary loads including firefighting system of the substation except lighting load |
| 41 | Lighting main distribution board, 230 V(L-L) indoor type with required no. of MCCBs/MCBs, etc. |
| 42 | Capacitor bank, 3.3 kV indoor type 1750 kVAR including APFC. |
| 43 | Battery (110 V) lead Acid type, 200 AH and battery charging (with one stand bye battery charging unit) equipment, control panels, wooden racks etc |
| 44 | Earthing system (Safe Earth Electrode type) including earth pits, required galvanised strips/flats for inter connection etc |
| 45 | Lightning protection system consisting of spikes, earth pits, galvanised strips/flats, shield conductors etc. |
| 46 | Luminairies |
| 47 | Decorative, LED light fittings of required watt |
| 48 | Tubular steel poles, 11m height along with 90W LED lamps with fittings (Min.) |
| 49 | Lighting masts, 16m height (Min) along with 6 nos. of 200 W LED lamps with fittings (Min.) |
| 50 | 90 W (min) LED lamps (complete) fitted on substation building (Min.) |
| 51 | Emergency lighting system suitable for operation on 110 V DC supply in substation building. |
| 52 | Accessories such as sub distribution board, junction boxes, individual control cables, PVC conduits/ casings, back up fuses, switches, sockets, ceiling roses, single core PVC cable with copper conductors, flexible wire etc. |
| 53 | Cable and accessories |
| 54 | HT power cable, 3300 V grade, XLPE, FRLS, Copper conductor |
| 55 | LT Power cable, 1100V grade, PVCSWA, 10 sq. mm.(minimum),3/4 core copper stranded conductors |
| 56 | Outdoor Lighting cable, 1100V, PVCSWA , 2 cores, 10 sq mm (minimum) stranded aluminium conductors |
| 57 | Outdoor Control cables, 1100V grade, PVCSWA, not less than 2.5 sq mm , copper conductors of with required number of cores |
| 58 | Wires for internal wiring of 1.5 sq mm and 6 sq mm size, PVC insulated copper conductor cable of 1100 V grade |
| 59 | Cables for internal control wiring of illumination, ceiling fans, power sockets etc. 2.5 sq mm size, PVC insulated copper conductor of 1100 V grade |
| 60 | Cable trays, cable racks, binding materials, cable glands/lugs, cable jointing kit, bolts, nuts, washers, termination kit etc. |
| 61 | Overhead conductors, Insulators, Towers, poles, insulators, strung bus, ACSR conductors, steel hardware etc for 33 kV sides in the outdoor switchyard. |
| 62 | Two pole structure fitted with gang operated AB switch, lightning arrester etc for 3.3kV out going feeders |
| 63 | SCADA System with associated electricals. |
| 64 | CCTV System with associated electricals and accessories |
| 65 | Fire Fighting System |
| 66 | Automatic fire protection system for main transformers (Nitrogen Injection Type) as per requirement of DGMS norms and TAC guidelines and specification (for 5.00 MVA, 33kV/3.3kV Main Transformers) |
| 67 | Fire extinguishers of different types, sand buckets, etc. as per specification complete with mounting arrangement |
| 68 | Fire / Smoke detection alarming system for Substation buildings, etc. |
| 69 | Fire hydrant system for outdoor yard including Hose Pump, Auxiliary diesel pump, Pipe hoses, hydrant pipe ,valves etc |
| 70 | Miscellaneous items |
| 71 | Room air conditioners, 2 ton capacity min. ( 5 star rating ) including servo stabilizer (Min.) |
| 72 | Supply of 63 kVA Diesel Generator set (silent type) with 3 ph, 50 Hz ,415 V output supply with cable, change over switch and earthing etc. |
| 73 | Exhaust fans, 600 & 225 mm sweep. |
| 74 | Ceiling fan, 1200 mm sweep along with electronic regulator (min.) |
| 75 | Vacuum cleaner Set |
| 76 | Oil Filtration Machine (Min 3000 lph capacity) |
| 77 | Submersible pump with associated electricals & cables complete |
| 78 | Water purifier (RO+UV+UF) with hot & cold water dispenser |
| 79 | Miscellaneous Items (Like Rubber mat, hand gloves, earthing rod, paper chart, danger plate, notice board etc. shall be provided as per safety requirement.and other items which is required to complete the work but not mentioned here. Etc.) for the Substation |
| 80 | PART-D Component of DLP Payment INCLUDING THE Operation of Plant (13.34% of the total quoted cost) |
| 81 | Total impact of GST for the purpose of CTC Please Enable Macros to View BoQ information |