Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Redevelopment of Thiruvananthapuram Railway Station – Departure Concourse (DCC) - Balance Civil work. |
| 2 | Schedule A - Civil Works - DSR |
| 3 | Schedule B - Civil Works - Non-DSR |
| 4 | Schedule C - Electrical works |
| 5 | Schedule D - Fire protection and Life safety system |
| 6 | Schedule A - Civil Works - DSR |
| 7 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 8 | Close timbering in case of shafts, wells, cesspits, manholes and the like including strutting, shoring and packing cavities (wherever required) etc. complete (Measurements to be taken of the face area timbered). |
| 9 | Close timbering in case of shafts, wells, cesspits, manholes and the like including strutting, shoring and packing cavities (wherever required) etc. complete (Measurements to be taken of the face area timbered). |
| 10 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for : PCC |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for : RCC |
| 13 | Concrete of M40 grade with minimum cement content of 390 kg /cum |
| 14 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 15 | Centering and Shuttering - Suspended floors, roofs, landings, balconies and access platform |
| 16 | Centering and Shuttering - Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 17 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 18 | Stairs, (excluding landings) except spiral-staircases |
| 19 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, PortlandPozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairingstrength; including pumping of concrete to site of laying, curing, carriagefor all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement contentin design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 5.33.1 All works upto plinth level |
| 20 | Providing and laying autoclaved aerated cement blocks masonry with150mm/230mm/300 mm thick AAC blocks in super structure aboveplinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar allcomplete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). |
| 21 | 12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) |
| 22 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface |
| 23 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 24 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes.110 dia |
| 25 | Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.0.80 mm thick with zinc coating not less than 275 gm/m² |
| 26 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab all colour and texture except black, Cherry/Ruby red |
| 27 | Providing and laying factory made Precast concrete solid blocks of 200 mm thickness of grade M10 made of C&D waste from approved manufacturer in superstructure above plinth level up to floor V level |
| 28 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 29 | Fabrication, supply & installation of top mounted SS 304 grade glass railing approved make made of SS top rail dia. 50 x 1.5 mm thk. mounted on SS baluster dia. 50 x 2 mm thk. with SS modular CNC made neck to hold the top rail as per drawing, laminated glass (8 mm clear toughened + 1.52 PVB + 8 mm clear toughened) of height 775 mm & length as per layout connected to the baluster with the help of CNC made modular glass holder as per drawing, fixed on the RCC floor with M8 GI stud chemically grouted by using Mungo VIT 400. All SS components are in SS 304 grade with satin finish, made by using modern, automatic machines like CNC machine, laser cutting, water jets etc. The item includes of materials, base plate screws, bolts, fabrication, any locking arrangements, transportation, cutting & making good the floor/walls, loading & unloading, handling of machineries complete as directed by engineer in charge. |
| 30 | Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including groutingthe joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. |
| 31 | Schedule B - Civil works Non-DSR Item |
| 32 | Boring, providing and installation of bored cast in-situ Reinforced Cement Concrete piles using Hydraulic Piling Rig of specified diameter and length below pile cap, of specified grade, with Design Mix Cement Concrete using 20 mm graded crushed stone aggregate and coarse sand of approved quality, to carry a safe working load not less than specified; including concreting by machine batching, machine mixing, scaffolding, using admixture in approved proportion (as per IS:9103), placing with tremie pipe, chipping off pile top to remove laitance concrete above cut-off level, pumping and bailing out water, etc., complete in all respects as per approved drawing, specification, and direction of the Engineer-in-Charge.Notes:Payment for only cement and reinforcement shall be made extra.Length of the pile for payment shall be measured up to the bottom of the RCC pile cap.Plasticiser shall invariably be used in approved proportion to increase workability with minimum possible quantity of cement for all grades of Design Mix Concrete, unless it is specifically approved citing reasons for not using plasticiser at the stage of Mix Design; in such cases, deduction shall be made as per relevant item. |
| 33 | Supplying, fabrication, and assembling of all types of sstructural steel for concourse of specified spans with structural steel conforming all structural steel and plates shall conform to grade E 350 (fe 490) as per is 2062, including erection / slewing / end launching of steel girders with cranes or any other approved launching methods as per site conditions on substructure, complete as per approved drawings.Detailed design drawings and launching methodology will be supplied by KRDCLThe contractor has to submit the QAP, shop drawings, fabrication and erection etcThe rate is all inclusive, including launching in position, complete in all respects including the cost of Painting (epoxy as per schedule DC).Payment shall be made on the theoretical weight of main components and gusset plates only.Payment Schedule:(i) Supply, fabrication and transporttion to the site – 60%(ii) Erection / Launching – 20%(iii) Completion in all respects – 20% |
| 34 | Providing and laying leather finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 25 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : |
| 35 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 25 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. |
| 36 | Providing and laying leather finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 40 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : |
| 37 | Providing sacrificing shutter with 1.0 mm thick galvanized steel deck sheet confirming to IS 277:1992 for shuttering of floor slab, including cost of material, transportaion and fixing in postion all complete as per direction of Engineer -in charge. No extra payment for overlapping. |
| 38 | Supply, fabrication and fixing 3mm thick, brush finish SS sheet (grade-316) cladding on columns with rounding at edges up to 3000mm height from floor finish level |
| 39 | Providing and fixing false ceiling as a combination of metallic open grid ceiling and gypsum board (ratio- 70% metallic open grid ceiling and 30% gypsum board ceiling finished with acrylic emulsion paint)at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating, etc. |
| 40 | Providing 50mm x 100mm powder coated aluminium baffle ceiling in wodden finish with 50mm gap screwed to steel channel welded on roof structural members at all heights etc. |
| 41 | Providing and fixing metallic open grid false ceiling finished with acrylic emulsion paint)at all height including providing and fixing of frame work etc |
| 42 | Providing and laying SS tactile studs (for vision impaired persons as per standards) of required size, complete as per direction of Engineer-in-Charge. |
| 43 | Semi unitized curtain wall glazing system on Polyester powder coated aluminum frames as per design and glass panels of Single Glass/ SGU (conforming to GRIHA standards- minimum 3star and confirming to minimum detailed specifications) and Powder Coated Aluminum Louvers as per design and as per architectural drawings |
| 44 | Providing portable fencing along running track where work is to be done in close vicinity of track, maintaining during execution of work and removing after completion of the work as per direction of the Engineer. Fencing shall consist of self supporting steel angles of size 50mm x 50mm x 6mm, 1.5m long provided with hooks etc. and embedded in CC 1:2:4 block of size 0.23m x 0.23m x 0.23m placed at c/c distance of 2m along track. 12mm dia rods in three horizontal layers shall be tack welded with angle posts.Note : Released material will be property of the contractor after completion of work. Cost of cement required for CC blocks shall be paid separately. |
| 45 | Barricading |
| 46 | Schedule C - Electrical works |
| 47 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 48 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 49 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 50 | 2 x 1.5 sq.mm + 1 x 1.5 sq.mm earth wire |
| 51 | 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire |
| 52 | 2 x 4 sq.mm +1 x 4 sq.mm earth wire |
| 53 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 54 | 20 mm |
| 55 | 25 mm |
| 56 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 57 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 58 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 59 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 15/16 A modular switch, connections etc. as required. |
| 60 | DISTRIBUTION BOARDS |
| 61 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 62 | 6 way (8 + 18), Double door |
| 63 | 8 way (8 + 24), Double door |
| 64 | Supplying and fixing Cable End Box (Loose wire box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. |
| 65 | CABLE MANAGEMENT SYSTEM |
| 66 | Supply and fixing of Perforated Cable tray with horizontal & vertical bends, reducers, Tee's, cross over, suitable supports and brackets and other accessories as required confirming to IEC-61537. The Tray shall be galvanized for corrosion protection confirming to DIN EN 10346 / ISO 1461. The trays should be tested for a max. safe working load of 150 Kgs with a span distance of 1.5 meters and the deflection should be within the limits as per standard. The safety factor shall be 1.7 times of the safe working load. The perforated tray shall be supplied with the standard length of 3 Mtr. Make: OBO Bettermann or Equivalent |
| 67 | 50 mm width X 60mm Height |
| 68 | 100 mm width X 60mm Height |
| 69 | 150 mm width X 60mm Height |
| 70 | MV CABLE SUPPLY, LAYING, & END TERMINATION |
| 71 | LT CABLE SUPPLY |
| 72 | Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) amended up to date. |
| 73 | 3.5C X 70 Sq.mm Al Cable |
| 74 | 3.5C X 35 Sq.mm Al Cable |
| 75 | 4C X 25 Sq.mm Al Cable |
| 76 | 4C X 10 Sq.mm Al Cable |
| 77 | 2C X 10 Sq.mm Al Cable |
| 78 | Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) amended up to date. |
| 79 | 3C X 2.5 Sq.mm Cu Cable |
| 80 | MV CABLE LAYING |
| 81 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface/cable tray as required. |
| 82 | Up to 35 sq. mm (clamped with 1mm thick saddle) |
| 83 | Above 35 sq. mm and up to 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 84 | MV CABLE JOINTING & END TERMINATION |
| 85 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. |
| 86 | 3.5C X 70 Sq.mm Al Cable |
| 87 | 3.5C X 35 Sq.mm Al Cable |
| 88 | 4C X 25 Sq.mm Al Cable |
| 89 | 4C X 10 Sq.mm Al Cable |
| 90 | 2C X 10 Sq.mm Al Cable |
| 91 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. |
| 92 | 3C X 2.5 Sq.mm Cu Cable |
| 93 | MCB, RCBO, MCCB, & ISOLATORS |
| 94 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 95 | Single pole |
| 96 | Double pole |
| 97 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 98 | RCBO - Supplying, fixing, testing and commissioning following four pole and double pole , 415 volts and 240 volts, residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity current in the existing MCB SPN and TPN horizontal/vertical DB's complete with connections, etc. as required and instructed by engineer in charge/consultant.. |
| 99 | 32A 30mA FP RCBO |
| 100 | Isolator With Enclosure - Supply and fixing of following DP/FP 230V / 415V, isolators in sheet steel powder coated enclosure with door interlock facility on surface confirming to IEC 60947-3 complete with all accessories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation. |
| 101 | 6A - 40A DP Isolator with enclosure |
| 102 | LT PANELS |
| 103 | LIFT PANEL 1 & 2 |
| 104 | Fabrication, supply, erection, testing, and commissioning of a cubicle-type, dust and vermin-proof, floor-mounted, front-operated Main Panel Board, constructed to Form 4A specifications, with a protection rating of IP-54 for dust and water ingress. The panel shall be made from 16 SWG thick CRCA sheet with 11-tank treatment, fully compartmentalized, and complete with hinged and earthed front doors. It shall include a nameplate, danger notice board, heavy-duty rubber gaskets, and removable gland plates made of 3mm thick sheet steel. All components will be as shown in the schematic drawing. All opening parts of the panel shall be sealable to ensure enhanced security and protection. |
| 105 | Incomer - 80A, FP MCB Isolator - 1No. |
| 106 | 80A, 415V, 25 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. |
| 107 | Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency, Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh - 1Set |
| 108 | Class B+C / Class 1 + 2 Surge arrestor device with necessary rating MCB for back-up protection - 1 No. |
| 109 | RYB phase indicating LED lamps with control fuses and switches - 1 set. |
| 110 | Outgoing |
| 111 | 40A, 100mA, FP RCBO - 2 No. |
| 112 | 16A, 30mA, DP RCBO - 2 No. |
| 113 | 16A, 415V, 16 kA best conductivity Al DP bus bar with SMC supports, heat shrinkable sleeves etc complete as required - 2 Sets |
| 114 | 10A, 10kA, SP MCB - 2 No. |
| 115 | 6A, 10kA, SP MCB - 6 Nos. |
| 116 | Supply, Installation, Testing and Commissioning |
| 117 | ESCALATOR PANEL |
| 118 | Fabrication, supply, erection, testing, and commissioning of a cubicle-type, dust and vermin-proof, floor-mounted, front-operated Main Panel Board, constructed to Form 4A specifications, with a protection rating of IP-54 for dust and water ingress. The panel shall be made from 16 SWG thick CRCA sheet with 11-tank treatment, fully compartmentalized, and complete with hinged and earthed front doors. It shall include a nameplate, danger notice board, heavy-duty rubber gaskets, and removable gland plates made of 3mm thick sheet steel. All components will be as shown in the schematic drawing. All opening parts of the panel shall be sealable to ensure enhanced security and protection. |
| 119 | Incomer - 125A, FP MCCB Isolator - 1No. |
| 120 | 125A, 415V, 25 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc. complete as required. |
| 121 | Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency, Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh - 1 Set |
| 122 | RYB phase indicating LED lamps with control fuses and switches - 1 set. |
| 123 | Outgoing |
| 124 | 63A, 100mA FP RCBO - 4 Nos |
| 125 | Supply, Installation, Testing and Commissioning |
| 126 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side as required. |
| 127 | LIGHT & FAN FIXTURES |
| 128 | INTERIOR LIGHT FIXTURES |
| 129 | Supply of a 100W LED highbay light with a luminous efficacy of up to 140 lumens per watt. The system wattage shall not exceed 120W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. It should have a color temperature of 5700K and a CRI > 80.The luminaire’s driver shall have a THD < 10% and a power factor (PF) > 0.95. It shall offer an IP66 protection rating. The die-cast aluminum housing facilitates free airflow, ensuring excellent thermal management by keeping heat away from the optics and electrical components. The high-transmittance polycarbonate lens enhances optical efficiency.The driver compartment is isolated from the housing, insulating the driver from heat to ensure a long service life with low running and maintenance costs. A factory-fitted eye bolt is also provided for ease of installation in suspension mounting The light fixture including driver shall comply to IEC and IS. Similar to Wipro Make Model No: LH21-122-060-57-X2 or equivalent. |
| 130 | Supply, fixing, testing and commissioning of Linear Surface / 40W LED Batten with a nominal system lumen output of minimum 4400 lumens. The system wattage shall not exceed 40 W.The luminaire shall have a rated system lifetime of minimum 50,000 burning hours at L70B50. The color temperature shall be 5700 K, with CRI > 80.The LED driver shall have THD < 10% and PF > 0.95.The heat sink shall be constructed from extruded aluminium, and the luminaire shall be provided with a high-efficiency polycarbonate diffuser.The luminaire shall have an Ingress Protection rating of IP40, suitable for indoor industrial / commercial / utility applications.The complete light fixture including driver shall comply with IEC and IS standards.The fixture shall be suitable for direct mounting / suspended mounting from ceiling / wall / false ceiling using clamps / GI chain / rope, complete with all necessary accessories.Connections shall be made using 1.5 sq.mm FRLS PVC insulated copper conductor single-core cable, including proper earthing, as required for complete installation. Similar to wipro (Model: LE23-491-XXX-57-G1 or equivalent) |
| 131 | Supply, fixing, testing and commissioning of LED Bulk Head Luminaire with max wattage of 10W with system lumens not less than 300 Lumes. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. Housing shall be pressure die cast aluminium with IP 65 rating. luminaire should have a color temperature of 5700K and CRI>80. Driver of the luminaire shall have THD<10% and PF >0.9. There should be in-built surge protection up to 2 KV. The LED Shall be ANSI Bin C78.377A and IEC62471 with class1 electrical insulation. Similar to Wipro Make LW07-141-XXX-57-XX or Equivalent, directly / suspended on ceiling / wall / false ceiling using clamps / GI chain / rope, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required with all accessories required for complete installation. |
| 132 | FAN FIXTURES |
| 133 | Supply, installation, testing and commissioning of HVLS Fan (2.5 m sweep) of approved make, direct drive / gearless type, complete with high-efficiency PMSM motor and aerodynamic aluminium alloy blades with corrosion-resistant finish. The fan shall be provided with an integral VFD / controller for smooth speed control, soft start, low noise and energy-efficient operation. The system shall include all necessary mounting hardware, down rods, safety cables, vibration isolators, control panel with overload and phase protection, earthing, and accessories. Similiar to Marley MPF08 -05 or Equivalent |
| 134 | EARTHING PROTECTION |
| 135 | Supply and laying the following sizes of earthing bare copper/strips on cable tray or wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts etc as required for complete installation as instructed by engineer in charge/consultant. |
| 136 | 25 X 3 Cu strips tinned at the joints |
| 137 | Copper wire No.10 SWG |
| 138 | Schedule D - Fire Protection & Life Safety System |
| 139 | FIRE PIPES, VALVES & ACCESSORIES |
| 140 | Hydrant, Sprinkler System and Plant Room : Providing, fixing, pressure testing and commissioning of Above Ground Pipe Work with Heavy Duty (Class-C) Mild Steel Pipes, confirming to IS: 3589/1239 Part - I (wherever applicable) and with Heavy Duty Black Ductile Iron Screwed Fittings for Pipes up to 50mm. dia. and But Welded Fittings, for pipes above 50mm. dia. confirming to IS:1239 Part - II with all accessories such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, welding, joining, fixing in ducts, on walls, ceiling etc. by using suitable and strong enough supports as per requirement, providing higher sizes of Sleeves / Opening, wherever required, and closing the gap between the pipes and sleeves/openings as per the direction of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting system as per technical specification. |
| 141 | 25 mm. |
| 142 | 32 mm. |
| 143 | 40 mm. |
| 144 | 50 mm. |
| 145 | 65 mm. |
| 146 | 80 mm. |
| 147 | 100 mm. |
| 148 | 150 mm. |
| 149 | Providing, fixing, testing and commissioning of Forged Ball Valve, PN-16 or above gunmetal /cast alloy, SS handle including necessary accessories and connections. |
| 150 | 25 mm. |
| 151 | Providing, fixing, testing and commissioning of Butterfly Valve, PN-16 or above, slim seal, standard lever operated type confirming to IS: 13095 Mark, with required companion flanges, nuts, bolts etc. complete. |
| 152 | 150 mm. |
| 153 | Providing and fixing sight glass assembly of brass body and brass ball with chrome plated Test & drain valve (25 mm), steel handle, PN16 or above, UL Listed & FM Approved. Test and drain valve shall be with compact 3 position ball valves with drain orifice having K-factor 5.6 and a sight glass. 3 positions consist of OFF, TEST and DRAIN. Test and drain valves shall be provided for test as well as express drain functions in wet sprinkler systems with grooved end connection ends. The Test and Drain Valve shall be in Brass ASTM B584 material of construction. These have integral tamper resistant sight glass. |
| 154 | Supply, installation, testing and commissioning of following 4\\" dia. Bourdon Type Pressure Gauge, with ISI Mark or of equivalent International Standards. |
| 155 | Standard Type for indoor use Pressure Gauge with shut off cock and connection Pipe. |
| 156 | FIRE HOSE REEL & HYDRANT SYSTEMS |
| 157 | Supply, installation, testing and commissioning of Manual Swing Type Fire Hose Reel Complete Set with heavy duty drum / reel, 19 mm. dia, 30 Meter long 2-ply polyester yarn braided / rubber braided pressure hose, Red Coloured, heavy duty nylon on/off jet/spray nozzle, 22 mm. isolating valve and all other necessary fixing accessories including Fabrication and Erection of M.S. Support, as per requirement, for Fixing the Fire Hose Reel Set. |
| 158 | Supply, installation, testing and commissioning of Fire Hydrant Valve, bearing to ISI:5290 Type-A mark, Stainless Steel-304 body with 63 mm. oblique instantaneous single outlet, 75 mm. N.B. flanged inlet, Stainless Steel - 304 spindle, complete with PVC blank cap, G.I. chain etc. |
| 159 | Supply, installation, testing and commissioning of Fire Hose, RRL hose jacketed with circular woven synthetic fiber. conforming to IS: 636:88, with Working Pressure 14 Kg/Cm2, Proof Pressure 22 Kg / Cm2 and Burst Pressure 38 Kg / Cm2. The Fire Hose shall be with IS: 636 Type-A marking and 63mm. dia., 15 Meter long with pair of 63mm. male and female instantaneous couplings, Stainless steel - 304, having IS: 903 mark and duly S. S. wire wounded. The hose shall be rolled and hung to suitable M. S. support in the Fire Hose Cabinet. |
| 160 | Supply, installation, testing and commissioning of Branch Pipe, Stainless Steel-304, short type, with 63mm. male instantaneous inlet, male threaded outlet, fitted with 16mm. bore nozzle, having IS: 903 mark. |
| 161 | Supply and fix at site in position MS Fire Hose Cabinet made out of 16 gauge MS Sheet, wall / pole mounting type, to accommodate two 15m length of delivery hose and branch pipe, acrylic fronted double door, with lock, 2 keys and a break glass recess for keys, painted Fire Red. The words \\"FIRE HOSE\\" to be painted on the box. The price shall be inclusive of fixing with all accessories and as per requirement. |
| 162 | AUTOMATIC FIRE SPRINKLER SYSTEM |
| 163 | Providing, fixing, testing and commissioning of Standard Coverage, Quick Response Automatic Fire Sprinkler, K- Factor: 5.6 (80 Metric) with all accessories necessary for complete installation. The Fire Sprinklers shall be UL listed / FM Approved |
| 164 | Pendant Type, 68 Degree C Rating. |
| 165 | Providing & Fixing 2 Piece Chrome Plated Friction Fit recessed escutcheon for pendant sprinklers, as per requirement. |
| 166 | Providing, Fixing, Testing and Commission Flexible Sprinkler Hose; UL Listed & FM Approved, 25mm. (1\\") BSP Male Inlet, 15mm. (1/2\\") NPT Female Outlet, Braided, Working Pressure 13.8 Bar, 1 meter long, and with all connecting systems and accessories required for complete installation. |
| 167 | Providing, Fixing, testing and commissioning of Flow Switch, with 20 Bar Working Pressure Protection with all necessary accessories, for monitoring Fire Sprinkler System. The control cabling from flow switches to Fire Sprinkler Annunciating Panel shall be measured separately. |
| 168 | INTELLIGENT ADDRESSABLE FIRE ALARM SYSTEM |
| 169 | Providing, fixing, test and commission Intelligent / Analogue Addressable Multi Sensor Detectors. The detectors shall have multiple sensitivity (adjustable at site) levels, programmable for timed automatic sensitivity selection complete with Standard Base, junction box and other accessories as required. Detectors shall be UL listed. |
| 170 | Providing, fixing test and commission Intelligent / Analogue Addressable Manual Call Station Point (Break Glass Type) with The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. The device shall comply UL Listed. |
| 171 | Providing, fixing, test and commission of Intelligent / Analogue Addressable notification device (Hooter cum Strobe) rated minimum 80 dB @ 3 Mtr. for audible annunciation and minimum 75 Candela flashing at 1Hz for visual indication, complete as per technical specifications. fully supervised and powered from FACP. Hooter and Strobe elements of the combined unit shall have independent activation & deactivation criteria. Suppliers not having single notification device meeting these requirements shall quote for Hooter cum Strobe with supervised control module separately, powered by FACP notification appliance circuit. No external 3rd party power supply shall be permitted. |
| 172 | Supply, installation, testing and commissioning of Intelligent / Analogue Addressable Input / Monitor Module, as per specification for interface with Flow Switches, Fire Pumps, Supervisory Switches, Alarm Valve, Water Tank Level etc. |
| 173 | Supply, installation, testing and commissioning of Intelligent / Analogue Addressable control / Relay Module, as per specification for interface with Lift Panel, Water Curtain Partition, AHUs, Ventilation System, Smoke Management System, Power Distribution, Public Address System etc. |
| 174 | Supply, installation, testing and commissioning of Intelligent / Analogue Addressable Fault Isolator Module capable of monitoring shorted loop circuit and automatically restore communications when shorted conditions are corrected, all as per technical specifications. |
| 175 | Supplying & laying of 2 Core 1.5 sqmm fire survival armoured cable, Red Colour, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. |
| 176 | FIRE EXTINGUISHERS |
| 177 | Supply, & fixing of following Portable Fire Extinguisher as per BIS 2190 and BIS: 15683:2006 and with relevant ISI Stamping/Marking. |
| 178 | ABC Dry Powder, Propellant - Dry Nitrogen, Store Pressure Type - 4 Kg. |
| 179 | Fire Bucket including Fabricated M. S. Stand |
| 180 | TALK BACK SYSTEM |
| 181 | Supply, installation, testing and commissioning of Public Address speaker with talk back facility 6 Watts with L M T and call switch, made out of powder coated CRCA sheet, wall mounting type and to be installed at a height of not less than 150 CM from the finished floor levels, suitable for concealed mounting. |
| 182 | SIGNAGES |
| 183 | Fire Exit Light |
| 184 | Fire Exit Light - Laser type, with High Glow LED Light, size: 12” x 6” or nearby, Ceiling Mounting type with hanging clamps, on/off switch, Red / Green Colour option, power consumption: 8 Watt or less with all accessories required for complete installation as directed by the engineer in charge. Power supply should be provided with UPS back-up. |
| 185 | Supply and install in position following Sign Boards made out of 3mm thick \\"Opaque\\" PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners with all accessories required for complete installation as directed by the Engineer in charge. |
| 186 | Signage Printed \\"IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE\\" of 1.25cm. height letters in red with white back ground. The size of the board shall be 25 x 30 Cm. and shall be fixed at the height of 2Mts. from finished floor near Manual Pull Stations. |
| 187 | Floor Identification Signage ( i.e., GROUND FLOOR, FIRST FLOOR, etc.) at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 5 Cm. with contrasting colour from back ground. Size shall be 15cm x 30cm. |
| 188 | Floor Identification Signage (MAIN STAIRCASE, FIRE STAIRCASE, FIRE ASSEMBLY POINT, PUMP ROOM, FIRE CONTROL ROOM, ELECTRICAL ROOM, FIRE LIFT, PASSENGER LIFT Etc.) at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 5 Cm. with contrasting colour from back ground. Size shall be 15cm x 30cm. |
| 189 | Supply and install in position the Signage \\"FIRE ORDER\\" it should contain the matter specified in the technical details on 3mm thick \\"Opaque\\" PVC foam board of computerized cut, PVC non-reflective self adhesive vinyl painted foam board of 2' x 3'. |
| 190 | MISCELLANEOUS ITEMS |
| 191 | FIRE SEALANT for all Shafts - Supply and Fixing of load bearing Fire stop mortar system with minimum 2 hours fire rating when tested in accordance with UL 1479 standards, for openings in floors or slabs after passing service lines. The mortar shall be a light weight cementitious product and shall carry test certificate in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product shall be age tested as per Dafstb and DIBT standards. The product shall carry test certificate for mold resistance rating of 0 as determined by ASTM G21-96 and shall have a VOC content of approx. <1 g/l as per LEED 2009. Firestop installation should be done by trained applicators (HAFSC) and in accordance with manufacturer's guidelines by providing 10mm dia rebars at 200mm c/c both ways with chemical anchoring along the length and breadth of the shaft and provide 2 layers of chicken mesh etc. The mortar shall be applied with a minimum thickness of 65 mm & having load bearing capacity of 200kg/sqm. Proper engineering judgement needs to be submitted through the manufacturer. Complete installation report through Software CFS DM shall also be submitted for inspection purpose. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |