| 1 | Supplying and fixing following size modules GI box along with modular base and cover plate for modular switches in recess etc as reqd |
| 2 | 1 or 2 Module |
| 3 | 3 Module |
| 4 | 4 Module |
| 5 | 6 Module |
| 6 | 8 Module |
| 7 | 12 Module |
| 8 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required Group B |
| 9 | Group A |
| 10 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box i/c connections but excluding modular plate etc. as reqd. |
| 11 | 5 amp switch |
| 12 | 5 amp socket |
| 13 | 15 amp switch |
| 14 | 15 amp socket |
| 15 | Bell Push |
| 16 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 17 | Supplying and fixing suitable size GI box wuth modular plate and cover in front or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SPMCB . 'C' curve including connections , painting etc as reqd |
| 18 | Suppling and fixing suitable sie GI Box modular Plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16A modular socket outlet and 15/16 A modular switch, connection etc. as reqd |
| 19 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required.Group A |
| 20 | Supplying and fixing Brass batten/angle holder including connection etc as reqd |
| 21 | Supplying and fixing 3 pin . 5 amp ceiling rose on the existing junction box/wooden block including connections etc as reqd |
| 22 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required |
| 23 | 1x1.5 sqmm |
| 24 | 2x2.5 sqmm |
| 25 | 2x4 sqmm |
| 26 | 2x6 sqmm |
| 27 | Supplying and fixing of following sizes of heavy class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required |
| 28 | Supplying and fixing call bell/buzzer suitable for single phase , 230 Volts complete as reqd |
| 29 | Supply, installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Moter, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. conopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as reqd. |
| 30 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.(But without MCB/ RCCB/ Isolator) |
| 31 | 12 Way Double Door |
| 32 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole |
| 33 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps |
| 34 | Suppyling and fixing following rating, double pole (Single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as reqd. 63 Amp |
| 35 | Supplying & fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as reqd |
| 36 | Supply, Instalation, testing and commissioning of pre-wired, single box fitting with one no. LED tube of frosted cover desig, T waty |2100 lm, 50000 burning hours, size 1200 mm complete i/c all accessories etc. directly on ceiling/wall, including connection with 1.3 Sq.mm FRLS PVC insulated, copper conductor cable and earthing etc. as required. fitting equivalent to Philips Make, Cat No. TMC 502 1X1-LED|22W, Tube equivalent to Philips Make, Cat No. Mas LEDTube 1200mm 18w 865 T81-2100lm |
| 37 | Supply, Installation, testing and commissioning of pre-wired, wall mounted fancy white light, suitable for installation of LED bulb, 220-240 V, 50 Hz complete li/c all accessories but without bulb etc. including connection, etc. complete as required. Make Philips, Cat No. Cat No. Comet wall fancy light B22 or equivalent model of Thorn/Trilux |
| 38 | Replacement of condenser of 2.5/3.15 mfd for ceiling fan including making necessary connections etc. complete as required Please Enable Macros to View BoQ information |