| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE(I) Kanpur Name of Work : SPL REPAIR/REPLACEMENT OF LOW TENSION (LT) OVERHEAD LINE INTO UNDERGROUND CABLE AT 4 ASSAM UNDER GE (I) KANPUR Contract No : GE(I)/KAN/T-84 OF 2025-26 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Items/Works Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Conversion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Excavation in trenches in any type of soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables,foundation filling of poles or stays and for rerouting of cables complete all as specified and directed. |
| 3 | Returning filling, including spreading, leveling, watering and well ramming in layers not exc 25 cm each all as required complete all as specified and directed. |
| 4 | Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed. |
| 5 | M&L for sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm, thick after laying, stretching and testing the cable complete all as specified and directed.Note:- Punned thickness shall be measured and paid. |
| 6 | M&L for Sub class ‘B’ bricks old size. laid dry flat over the cable abutting each other, length of cable equal to width of brick all as required complete all as specified and directed. |
| 7 | Supply and laying in trenches or fixing to wall/pole or passing through pipe of XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 240 Sqmm 3.5 core complete all as specified and directed. (Note : Incl making good all distributed wall surfaces/ flooring/tilling to match with existing specification) |
| 8 | Supply and laying in trenches or fixing to wall/pole or passing through pipe of XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 120 Sqmm 3.5 core complete all as specified and directed. (Note : Incl making good all distributed wall surfaces/ flooring/tilling to match with existing specification) |
| 9 | Supply and laying in trenches or fixing to wall/pole or passing through pipe of XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 95 Sqmm 3.5 core complete all as specified and directed. (Note : Incl making good all distributed wall surfaces/ flooring/tilling to match with existing specification) |
| 10 | Supply and laying in trenches or fixing to wall/pole or passing through pipe of XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 70 Sqmm 3.5 core complete all as specified and directed. (Note : Incl making good all distributed wall surfaces/ flooring/tilling to match with existing specification) |
| 11 | Supply and laying in trenches or fixing to wall/pole or passing through pipe of XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 50Sqmm 3.5 core complete all as specified and directed. (Note : Incl making good all distributed wall surfaces/ flooring/tilling to match with existing specification) |
| 12 | Supply and laying in trenches or fixing to wall/pole or passing through pipe of XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 35Sqmm 3.5 core complete all as specified and directed. (Note : Incl making good all distributed wall surfaces/ flooring/tilling to match with existing specification) |
| 13 | Supply and laying in trenches or fixing to wall/pole or passing through pipe of XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 25 Sqmm 4 core complete all as specified and directed. (Note : Incl making good all distributed wall surfaces/ flooring/tilling to match with existing specification) |
| 14 | Supply and laying in trenches or fixing to wall/pole or passing through pipe of XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 16 Sqmm 4 core complete all as specified and directed. (Note : Incl making good all distributed wall surfaces/ flooring/tilling to match with existing specification) |
| 15 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm 4 core complete all as specified and directed. |
| 16 | Material and labour for GI tubing light grade 50mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as specified and as directed. NOTE-clamps for fixing pipe, nuts, bolts washers shall be included in quoted unit rate complete all as specified and directed. |
| 17 | All as per item No 15.00 above but 40mm bore complete all as specified and directed. |
| 18 | Supply & fix of cable PVC insulated flexible Copper conductor cable of size 1.5 Sqmm 3 core cut to pieces all as required for connetion with proper thimbles, drawn in existing/new GI pipe fixed to wall or pole complete all as specified and directed. |
| 19 | S&F of bus bar chamber outdoor type of size 400 x 380 x 190 mm made out of MS sheet 2 mm thick with 200 Amp aluminium bus bar three phase & neutral each 320 x 20 x 6 mm of size fixed on insulators and fixing on steel pole with proper clamps, nuts , bolts & washers of required size and making connection of LT cables with thimbles, glands and making good the disturbed surfaces incl water proof PVC sticker like danger mark complete all as specified and directed. |
| 20 | Supply and installation, connecting eclectically & commissioning of LT feeder pillar box outdoor type of size 0.90 x 0.60 x 0.50 Mtr size factory fabricated made out of MS sheet of thickness 3.15 mm front door openable with locking arrangement mounted on angle iron legs made out of angle iron of size 40x40x6mm, 1.5 mtr long, 1.0 mtr above ground level and 0.50 mtr embedded in PCC blocks of size 0.30x0.30x0.50 mtr- 04 Nos duly painted with two coats of synthetic enamel paint over and including a coat of red oxide complete with 200 amps rated aluminium bus bar suitable for 3 phase 4 wire supply system duly drilled holes and making all cable connection with proper thimbles mounted on epoxy based post insulators and one MCCB 100 Amps 4 pole 415 Volt, 35 KA complete all as specified and directed. |
| 21 | Dismantling from insulators and taking down ACSR conductor any size from HT/LT over head lines and depositing to MES store yead complete all as specified and directed. |
| 22 | Dismantling insulator any type and any size from HT/LT over head lines and fixing other side or depositing to MES store yard complete all as specified and directed. |
| 23 | Dismantling, cross arms, clamps, supports made of channels or angle section etc including nuts and bolts and setting aside for reuse on the same or new location or depositing to MES store yard complete all as specified and directed. |
| 24 | Supply,installing, testing and commissioning outdoor type LT feeder piller box double door type (Safety Centre) of suitable size, padestal mounted, CPRI approved factory made totally enclosed, dust and vermin proof, double, front side openable, type IP-54 protection made of CRCA sheet 3.15 mm thick of outer panel and 2.00 mm thick inner compartment of panel size as per IS and having proper locking arrangement in front side door suitable for 440 volts, 50 Hz, 3 phase 4 wire system including cable glands of suitable size for incoming and outgoing cables and comprising with and including following accessories and mounted on PCC Plat form min 45 cm from ground level and PCC 1:3:6, 100 mm thick, 0.5 m all round the panel board including disconnecting cable from old unsv LT feeder piller box with MCCB, MCB, main switch, busbar and dismantling the same with the following items housed in :-BUSBAR :- 600 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite / DMC insulator bus bar support (Square / round) insulators of suitable size and good insulation resistance (Busbar to MCCB shall be connected through suitable size of copper busbar).INCOMING:- (i) 4 pole MCCB of capacity 400 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 36 KA with microprocessor release type with overload adjustability - 01 No. (ii) Digital multifunctinal meter V, A, F, kW, KVA, kWh, kVAh, kVArh, THD, Neutral current, Max Demand (with RTC),- 01 No.(iii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (RED, ORANGE, BLUE) -01 set(iv) CT (200/5A) -03 Nos (v) Square type heavy duty capacitor 440 V,10 KVAr conforming to IS 13340-1993 incl suitable fixing and paralell connection with the commercial line Outgoing: (a) 4 pole MCCB of capacity 250 Amp, breaking capacity 25 KA with microprocesser release adjustable type-3 Nos (b) MCCB 4 Pole of capacity 125 Amp breaking capacity 25 KA with microprocessr release, adjustable type- 1Nos. (Note) : Rate quoted shall be deemed to be inclusive of replacement of all cable lugs by removing damage part of cable and taking out cable from premises shall be carried out by the Engr-in-Charge or rep of GE (I) Kanpur has detaild by GE. |
| 25 | Supply,installing, testing and commissioning outdoor type LT feeder piller box double door type (Safety Centre) of suitable size, padestal mounted, CPRI approved factory made totally enclosed, dust and vermin proof, double, front side openable, type IP-54 protection made of CRCA sheet 3.15 mm thick of outer panel and 2.00 mm thick inner compartment of panel size as per IS and having proper locking arrangement in front side door suitable for 440 volts, 50 Hz, 3 phase 4 wire system including cable glands of suitable size for incoming and outgoing cables and comprising with and including following accessories and mounted on PCC Plat form min 45 cm from ground level and PCC 1:3:6, 100 mm thick, 0.5 m all round the panel board including disconnecting cable from old unsv LT feeder piller box with MCCB, MCB, main switch, busbar and dismantling the same complete with the following items housed in :-BUSBAR :- 400 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite / DMC insulator bus bar support (Square / round) insulators of suitable size and good insulation resistance (Busbar to MCCB shall be connected through suitable size of copper busbar).INCOMING:- (i) 4 pole MCCB of capacity 250 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 25 KA with overload adjustability with rotary handle- 01 No. (ii) Digital multifunctinal meter V, A, F, kW, KVA, kWh, kVAh, kVArh, THD, Neutral current, Max Demand (with RTC),- 01 No.(iii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (RED, ORANGE, BLUE) -01 set(iv) CT (200/5A) -03 Nos OUTGOING:- (a) 4 pole MCCB of capacity 100 Amp, breaking capacity 25 KA with themal magnetic release adjustable type - 04 Nos(b) MCCB 4 pole of capacity 63 Amp breaking capacity 25 KA with thermal magnetic release, adjustable type with rotary handle - 01 Nos(NOTE: Rate quoted shall be deemed to be inclusive of replacement of all cable lugs, by removing damaged part of cable and taking out cable from loop to required length including necessary earth work as per site requirement or as directed by Engr-in-charge) |
| 26 | S&F in replacement of weatherproof junction box of size 325x220x150 mm outdoor type made out of thermo polycarbonat to accmmodated 04 Nos aluminium bus bar of size 25x6 mm rating 200 Amps and MCB SP 6 Amps IP-65 with hinged door and triangular locks water proof, shocked proof, rust proof, corrosion free, acid resistance/fire retardent and self extinguishing UV resistance complete fixed on pole with flat iron clamps of size 25 x 3mm, nuts, bolts, washers etc., including two coats of synthetic enamel paint over and including a coat of redoxide zinc chrome primer on iron/steel parts complete all as specified and directed. |
| 27 | Supply, fixing, testing and comissioning of automatic street light switch of capacity 8 KW in single phase using nature switch for automatic switching of street lights based on LUX level of natural light. The sensor (nature switch) along with suitable power contactor, MCB and support terminals enclosed in pole / wall mounted enclosure made of rust proof, electric shock proof, termite proof and FR grade SMC junction box conforming to IP54, including mounting arrangement with suitable size of FI clamps 02 Nos with complete acessories as under including taking down old street light switch complete all as specified and directed. (i) Contactor rating (AC3) single phase, 50-63 Amp(ii) MCB 63Amps (SP),10 KA, 240 volts(iii) NATURESWITCH-01 |
| 28 | Supply and fixing in replacement of LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified & directed. |
| 29 | M&L for Earthing with galvanised iron earth plate electrode of size 600x600x6.3 mm thick as earth electrode with top edge of the earth plate not less than 1.5mtr below ground level using galvanised iron strip 32x6mm as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers including providing earth wire protection pipe GI light grade 40mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover in PCC 1:3:6 adequate quantity of charcoal dust and salt all around the earth plate, earth work in any type of soil reaming surplus excavated material all as required at site and specified in EP No 5 of SSR part I 1991 or directed by Engineer-in-charge incl testing on completion. |
| 30 | M&L for drilling manually in soft / loose soil under road / hard standing / culvert / nala of suitable bore for protection cable & pipe upto 80 mm bore complete all as specified. Note: Depth of bore shall not be more than 1 Mtr from original ground level complete all as specified and directed. |
| 31 | Supply & laying DWC pipe of 38 mm internal and 50 mm outer dia for cable protection complete all as specified and directed. |
| 32 | Supply fixing cutting welding jointing etc to LT cable rout indicator made out by MS angle 60 CM long in size 40 MM x 40 MM and 5 MM thick as stand and 6 inch dia with 5 MM thick rounded indicating plate continious welding on top edge of stand incl painting in two coats using synthetic enamelled paint over and including one coat of primer red oxide and stand grouting in cement concrete brick foundation minimum 30 CM etc to be fixed complete all as specified and directed. Note : (i) Indicating sign shall be embossed on MS round plate and cost cement concrete work shall be included in quoted item rate. (ii) Quoted rate shall be included cost for required earth work to trace the correct route of cable. Total in Figures 0.0 23 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |