| 1 | Supply and laying in replacement UG cables in trenches, or fixing on walls or passing through cable duct / pipe XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric power cables (heavyduty) with aluminium conductor, 1100 volts, grade having cross sectional area 3.5 core 300 sqmm with necessary thimble, suitable cable gland, including taking down of old unservicable cable complete all as specified and directed. |
| 2 | Supply and laying in replacement UG cables in trenches, or fixing on walls or passing through cable duct / pipe XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric power cables (heavyduty) with aluminium conductor, 1100 volts, grade having cross sectional area 3.5 core 240 sqmm with necessary thimble, suitable cable gland, including taking down of old unservicable cable complete all as specified and directed. |
| 3 | Supply and laying in replacement UG cables in trenches, or fixing on walls or passing through cable duct / pipe XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric power cables (heavyduty) with aluminium conductor, 1100 volts, grade having cross sectional area 3.5 core 185 sqmm with necessary thimble, suitable cable gland, including taking down of old one complete all as specified and directed. |
| 4 | Supply and Lay in replacement UG cable in trenches/passing through pipes/fixed on walls or poles cable XLPE insulated ,screened,PVC bedded,steel strip or wire armoured electric power cables(Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 core 150 Sqmm with suitable cable glands complete all as specified and directed. |
| 5 | Supply and laying in replacement UG cables in trenches, or fixing on walls or passing through cable duct / pipe XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric power cables (heavyduty) with aluminium conductor, 1100 volts, grade having cross sectional area 3.5 core 120 sqmm with necessary thimble, suitable cable gland, including taking down of old unservicable cable complete all as specified and directed. |
| 6 | Supply and laying in replacement UG cables in trenches, or fixing on walls or passing through cable duct / pipe XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric power cables (heavyduty) with aluminium conductor, 1100 volts, grade having cross sectional area 3.5 core 95 sqmm with necessary thimble, suitable cable gland, including taking down of old unservicable cable complete all as specified and directed. |
| 7 | Supply and laying in replacement UG cables in trenches, or fixing on walls or passing through cable duct / pipe XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric power cables (heavyduty) with aluminium conductor, 1100 volts, grade having cross sectional area 3.5 core 70 sqmm with necessary thimble, suitable cable gland, including taking down of old unservicable cable complete all as specified and directed. |
| 8 | Supply and laying in replacement UG cables in trenches, or fixing on walls or passing through cable duct / pipe XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric power cables (heavyduty) with aluminium conductor, 1100 volts, grade having cross sectional area 3.5 core 50 sqmm with necessary thimble, suitable cable gland, including taking down of old one complete all as specified and directed. |
| 9 | Supply and laying in replacement UG cables in trenches, or fixing on walls or passing through cable duct / pipe XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric power cables (heavyduty) with aluminium conductor, 1100 volts, grade having cross sectional area 3.5 core 35 sqmm with necessary thimble, suitable cable gland, including taking down of old one complete all as specified and directed. |
| 10 | Supply and laying in replacement UG cables in trenches, or fixing on walls or passing through cable duct / pipe XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric power cables (heavyduty) with aluminium conductor, 1100 volts, grade having cross sectional area 3.5 core 25 sqmm with necessary thimble, suitable cable gland, including taking down of old one complete all as specified and directed. |
| 11 | Supply and laying in replacement UG cables in trenches, or fixing on walls or passing through cable duct / pipe XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric power cables (heavyduty) with aluminium conductor, 1100 volts, grade having cross sectional area 4 core 16 sqmm with necessary thimble, suitable cable gland, including taking down of old one complete all as specified and directed. |
| 12 | Supply and laying in replacement UG cables in trenches, or fixing on walls or passing through cable duct / pipe XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric power cables (heavyduty) with aluminium conductor, 1100 volts, grade having cross sectional area 4 core 10 sqmm with necessary thimble, suitable cable gland, including taking down of old one complete all as specified and directed. |
| 13 | Supply and fixing,cable straight through jointing kit for 1.1 KV (earthed) grade cable,heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 16 to 50 Sq mm including taking down old item, complete all as specified and directed. |
| 14 | Supply and fixing,cable straight through jointing kit for 1.1 KV (earthed) grade cable,heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 70 to 95 Sq mm including taking down old item, complete all as specified and directed. |
| 15 | Supply and fixing,cable straight through jointing kit for 1.1 KV (earthed) grade cable,heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 120 to 150 Sq mm including taking down old item, complete all as specified and directed. |
| 16 | Supply and fixing,cable straight through jointing kit for 1.1 KV (earthed) grade cable,heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 185 to 240 Sq mm including taking down old item, complete all as specified and directed. |
| 17 | Supply and fixing,cable straight through jointing kit for 1.1 KV (earthed) grade cable,heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 300 to 400 Sq mm including taking down old item, complete all as specified and directed. |
| 18 | Supply and fixing of LT cable route indicators of material Cast iron complete all as specified and directed. |
| 19 | Taking down of unservicable and unused LT UG cable of any size or any capacity from trench/wall/floor and issue the unservicable cable to contractor under schedule of credit complete all as specified and directed. |
| 20 | Material and labour 150 mm bore high density polyethylene pipes (HDPE) PN 10 laid in trenches/Wall/road crossing for suitable length as per site requirement complete all as specified and directed. |
| 21 | Material and labour 100 mm bore high density polyethylene pipes (HDPE) PN 10 laid in trenches/Wall/road crossing for suitable length as per site requirement complete all as specified and directed. |
| 22 | Material and labour 75 mm bore high density polyethylene pipes (HDPE) PN 10 laid in trenches/Wall/road crossing for suitable length as per site requirement complete all as specified and directed. |
| 23 | Material and labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in GI pipe40 mm or fixed with poles or any other indicated situation for loop earthing etc as required using galvanised iron strip of size 32 x 6 mm complete all as specified and directed. |
| 24 | Supply and fixing LT aluminium bus bar panel with TPN bus bar of 500 Amps , outdoor type, pedestrial mounted fabricated through CPRI approved factory manufacturers, totally enclosed dust and vermin proof openable from both front and rear side made out of self 3 mm thick CRCA (Cold Rolled Cold Annealed) MS sheet of suitable length, width and height as per IE rule to accomodate all the items and conforming to IS-8623 and built upon 40 x 40 x 6 mm size angle frame work having front and rear hinged doors with neoprene rubber gasket, danger plate, GI earthing strips at rear side, bottom detachable gland plate complete with suitable size single plated and passivated nuts, bolts, spring washers. The cabinet and all members shall be chemically treated with MSR solution for aircorrosive treatment and powder coated (shade RAL - 7032) with 9 tank process and shall be with IP-65 grade protection. The Panel should be mounted/fixed at a height of above 70 cm from foundation to avoid water stagnation during monsoon season.The panel shall be suitable for 415 volts, 50 Hz 3 phase 4 wire system and internal connections which shall be provided with aluminium strips of suitable size and comprising of the following accessories:- BUS BAR CHAMBER : (i) Sheet steel bus bar chamber having front hinged covers with a set of electrolytic grade high conductivity TP&N solid aluminium bus bars, rated 500 Amps supported at required intervals sleeved with heat shrinkable PVC sleevings. The bars shall be colour coded at required intervals for identification - 01 No (Set of 04) (i) MCCB, 4 pole, 320 Amps, 50 KA - 01 No(Incomer) (ii) MCCB 4 pole 200 Amps,35 KA - 01 No(iii) MCCB 4 pole 100 Amps,25 KA - 02 Nos(iv) Digital volt meter with selector switch 500 V 1 No(v)Digital Ampere meter with selector switch and CT's 1 No(vi) Connecting the existing UG cables with suitable size cable thimbles and new nuts washers etc as per site requirement all as directed. |
| 25 | Supply and fixing LT aluminium bus bar panel with TPN bus bar of 400 Amps outdoor type, pedestrial mounted fabricated through CPRI approved factory manufacturers, totally enclosed dust and vermin proof openable from both front and rear side made out of self supported 2 mm thick CRCA (Cold Rolled Cold Annealed) MS sheet of suitable length, width and height as per IE rule to accomodate all the items and conforming to IS-8623 and built upon 40 x 40 x 6 mm size angle frame work having front and rear hinged doors with neoprene rubber gasket, danger plate, GI earthing strips at rear side, bottom detachable gland plate complete with suitable size single plated and passivated nuts, bolts, spring washers. The cabinet and all members shall be chemically treated with MSR solution for aircorrosive treatment and powder coated (shade RAL - 7032) with 9 tank process and shall be with IP-65 grade protection.The panel should be mounted/fixed at a height of above 70 cm from foundation to avoid water stagnation during monsoon season. The panel shall be suitable for 415 volts, 50 Hz 3 phase 4 wire system and internal connections which shall be provided with aluminium strips of suitable size and comprising of the following accessories:- BUS BAR CHAMBER : (i) Sheet steel bus bar chamber having front hinged covers with a set of electrolytic grade high conductivity TP&N solid aluminium bus bars, rated 400 Amps supported at required intervals sleeved with heat shrinkable PVC sleevings. The bars shall be colour coded at required intervals for identification - 01 No (Set of 04) (i) MCCB, 4 pole, 250 Amps, 50 KA (Incomer) (ii) MCCB 4 pole,100 Amps,25 KA - 03 Nos(iii) Digital volt meter with selector switch 500 V 1 No(iv)Digital Ampere meter with selector switch and CT's 1 No(v) Connecting the existing UG cables with suitable size cable thimbles and new nuts washers etc as per site requirement all as directed. |
| 26 | Excavation in tenches not exceeding 1.5M in depth and not exceeding 1.5M wide for laying pipes and getting out in soft/loose soil complete all as specified and directed. |
| 27 | Returning fitting in soil inclduing spreading, leveling , watering and well ramming in layers not exceeding 25 cm complete all as specified and directed. |
| 28 | Removing excavated materials not exceeding 50 Mtr depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 29 | Supply and laying of DWC (double wall corrugated) pipes of size 50 mm outer dia,IS:16205(Part-24) laid in trenches for underground cable protection complete all as specified and directed. |
| 30 | Supply and laying of DWC (double wall corrugated) pipes of size 63 mm outer dia,IS:16205(Part-24) laid in trenches for underground cable protection complete all as specified and directed. |
| 31 | Supply and laying of DWC (double wall corrugated) pipes of size 90 mm outer dia,IS:16205(Part-24) laid in trenches for underground cable protection complete all as specified and directed. |
| 32 | Supply and laying of DWC (double wall corrugated) pipes of size 120 mm outer dia,IS:16205(Part-24) laid in trenches for underground cable protection complete all as specified and directed. |
| 33 | Supply and laying of DWC (double wall corrugated) pipes of size 160 mm outer dia,IS:16205(Part-24) laid in trenches for underground cable protection complete all as specified and directed. |
| 34 | Material and labour for rerouting of UG LT cables of any size passing through drains by taking down old rusted GI pipe of different size and clamping the cable properly on wall/along the drain and supplying new GI pipe of various sizes for cable protection complete all as specified and as directed as per site requirement. Note:- GI Pipes for cable protection shall be measured and paid separately. |
| 35 | Supply and fix in replacement junction box made of hot press moulded SMC junction boxes of size 250x200x100 mm GSJB-2520 including one MCB SP 6 Amps,cable connector and suitable size clamps fixing for pole/in pcc foundation and including taking down old unservicable fitting complete all as specified and directed. Please Enable Macros to View BoQ information |
| 36 | Supply and fix in replacement junction box made of hot press moulded SMC junction boxes of size 250x200x100 mm GSJB-2520 including one MCB SP 6 Amps,cable connector and suitable size clamps fixing for pole/in pcc foundation and including taking down old unservicable fitting complete all as specified and directed. Please Enable Macros to View BoQ information |