| 1 | Excavation in trenches not exc 1.50 m wide and not exc 1.50 m deep for foundation, laying of pipe or for shafts, wells cesspits, man holes, pier holes, laying of cable etc not exc 10 Sqm on plan and n exc 1.5m in depth and getting out in soft / loose soil complete all as specified and as directed. |
| 2 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm in soft / loose soil complete all as specified and as directed. |
| 3 | Removing excavated soil to distance not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting point etc complete all as specified and as directed. |
| 4 | M & L for PCC 1:4:8 Type D-2 ( Using 40 mm graded crushed stone aggregate) as in foundation , filling, and mass concrete complete all as specified and directed. |
| 5 | M & L for PCC 1:2:4, type B1 (using 20 mm graded crushed stone aggregate) as in benching and coping, pole coping, cills, fixing of post, water trough etc. including necessary formwork (straight or curved) including demolition of old concrete complete all as specified and as directed. |
| 6 | M & L for PCC 1:2:4, type B1 (using 20 mm graded crushed stone aggregate) as in benching and coping, pole coping, cills, fixing of post, water trough etc. including necessary formwork (straight or curved) complete all as specified and as directed. |
| 7 | Supplying, erecting & fixing in true vertical position, steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31 (9.0 metres long) confirming to IS-273 (Part I & II) including painting of pole with two coats of aluminium paint over a coat of red oxide zinc chrome primer from top of the pole to 1.5m above the bottom of the pole and painting with two coats of black bituminous paint over a coat of red oxide zinc chrome primer upto 1.5m from bottom of the pole with numbering of poles including dismantling of old PCC pole complete all as specified and as directed. |
| 8 | M&L for Cross arms, bracings, supports, clamps, eye hook and back plates fabricated from structural steel sections including pole clamps, stay clamps, D clamps nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and including two coats of aluminuum paint over a coat of red oxide primer including dismantling of old cross arms complete all as specified and as directed. |
| 9 | S&F in repairs, SMC kiosks box/ PVC Junction box for pole suitable for three phase 415 volts AC supply with 04 Nos Aluminium bus bar rating 63 amps with one No. MCB 10 Amps, SP having size 350mmx270mmx200mm complete including flat iron clamp and all making fixing arrangement with pole complete all as specified and as directed. |
| 10 | M&L for Flexible cable of size 1.5 Sqmm 3 core with multistranded copper conductor FR round 1100 Volts grade heavy duty cable PVC insulated in street light connection from pole junction box at bottom to street light fittings by making two holes for inserting cable including taking down old cable complete all as specified and as directed. |
| 11 | S&F in repairs, MCBs, SP 6 to 32 Amps, 10 KA, 'B' curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. |
| 12 | M&L for preparation of newly plastered surface or concrete (Pole coping) exceeding 10 cm width or girth and applying two coats of plastic emulsion paints complete all as specified and as directed. |
| 13 | Supply, laying and testing XLPE Insulated , PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 16 sqmm 4 core laid in trenches /floor or fixed on wall/pole in existing or new location including brass compression cable glands, terminal lugs etc,including dismantling of old cable of any description complete all as specified and as directed. |
| 14 | Supply, laying and testing XLPE Insulated , PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 25 sqmm 3.5 core laid in trenches /floor or fixed on wall/pole in existing or new location including brass compression cable glands, terminal lugs etc,including dismantling of old cable of any description complete all as specified and as directed. |
| 15 | M&L for sand cushioning with dry river sand in trenches for cushioning of underground cable including spreading, leveling, punning down the thickness of sand upto 18cm and consolidated complete all as specified and as directed. Note: Punned thickness of sand cushioning will be measured and paid. |
| 16 | M&L for sub class ‘B’ old size well burnt brick laid flat in trenches with length of brick perpendicular to length of cable, over the cable for protection of LT cable complete all as specified and as directed. |
| 17 | Relaying of old serviceable bricks for cable protection obtain from taking out of old cable complete all as specified and as directed. |
| 18 | M& L for manual boring under roads/hard standing using required T&P without disturbing the top surface of the road, inserting GI pipe n exc 100 mm dia for cable protection complete all as specified and as directed. Note : - GI pipe will be measured & paid separately. |
| 19 | Supply and laying GI tubing 40mm bore light grade with fittings laid in trenches, on pole and road crossing for protection of LT underground cables complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 20 | Supply and laying GI tubing 40mm bore light grade with fittings laid in trenches, on pole and road crossing for protection of LT underground cables complete all as specified and as directed. Please Enable Macros to View BoQ information |