| 1 | M&L for dismantling &Taking down unserviceable street light fittings LED Fittings/ CFL Fittings,post top lantern,garden light, Pin /Holder type from pole or from Bldgs for repairs including replacement of unserviceable Lamp, holder, integral wiring with appropriate gauge copper conductor and refixing the same after repairs in original position properly using PVC insulation tape or where directed complete including replacement of any spares,cable connections from OH conductors,or from junction boxes to light fitting all as specified and as directed.Note : Spares items such as LED driver and cable etc, will be measured and paid separately under respective items. |
| 2 | Dismantling and taking down broken/damaged PCC/Steel pole complete all as specified and directed. |
| 3 | Taking down old u/s cable complete all as specified and directed. |
| 4 | Supply & Fixing in replacement of the following spare parts in street lights :- |
| 5 | PVC insulated weather proof sheated alluminium cable 2.5 sq mm 2 core |
| 6 | LED Driver 60 Watt of Make Bajaj/Equivalent |
| 7 | LED Driver 90 Watt of Make Bajaj/Equivalent |
| 8 | LED Driver 100 Watt of Make Bajaj/Equivalent |
| 9 | Supply and fixing in replacement Integral LED security light luminaire 90W LED 230 volts made of pressure die cast aluminium housing with high power LED’s lens & toughned glass IP-66 suitable for mounting existing bracket of size 32/40mm dia G I pipe, fixing clamps ,bolts, nuts of suitable size as required at site complete all as specified and as directed. |
| 10 | Supply and fix Integral LED security light luminaire 60W LED 230 volts made of pressure die cast aluminium housing with high power LED’s lens & toughned glass IP-66 suitable for mounting existing bracket of size 32/40mm dia G I pipe, fixing clamps ,bolts, nuts of suitable size as required at site complete all as specified and as directed. |
| 11 | Supply and fix Integral LED security light luminaire 35W LED 230 volts made of pressure die cast aluminium housing with high power LED’s lens & toughned glass IP-66 suitable for mounting existing bracket of size 32/40mm dia G I pipe, fixing clamps ,bolts, nuts of suitable size as required at site complete all as specified and as directed. |
| 12 | Supply and fix Integral LED security FLOOD light luminaire 120W LED 230 volts made of pressure die cast aluminium housing with high power LED’s lens & toughned glass IP-66 suitable for mounting existing bracket of size 32/40mm dia G I pipe, fixing clamps ,bolts, nuts of suitable size as required at site complete all as specified and as directed. |
| 13 | M&L outdoor type street light junction boxes with PVC water tight encloser, ready made type, with provision of suitable aluminium bus bars for three phases and one neutral mounted on insulators and bus bar having provision of 10 A SP MCB terminal connection and inter connection of street light from pole to pole and pole to light fittings including necessary PVC insulated weather proof twin core 2.5 Sqmm (nominal area) aluminium conductor cable, 1100 volts grade drawn and including PVC conduit of suitable size with clamps (3 Nos) , nuts, bolts etc from Junction box to street light connection, including taking down of existing unserviceable of junction box complete all as specified and as directed. |
| 14 | M&L for steel tubular poles complete with cast iron base plate, final taper plug, bolt, nuts and screws as specified type 410 SP-31(9 mtr long). Including painting pole with two coats of bituminous paint internally and external embedded portion in ground concrete and painting exposed surface with two coats of aluminum paint over one coats of aluminum paint over one coat of red oxide primer including taking down of existing LT pole of any size and re-fixing of chaneel, insulator and electric connection etc, all as specified and directed. |
| 15 | Supply and laying XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked as per IS 7098-I laid in trenches ducts or fixing or passing through GI pipe across the road/path/drains/along wall/floor/equipment etc. cross sectional area 70 Sqmm 3.5 core with necessary cable lugs, ncluding taking down unserviceable cable, complete all as specified and directed. |
| 16 | All as per item no- 15 here in before but 50 Sqmm 3.5 core |
| 17 | All as per item No 15 here in before but 35 Sqmm 3.5 core |
| 18 | All as per item No 15 here in before but 25 Sqmm 3.5 core |
| 19 | All as per item No 15 here in before but 16 Sqmm 4 core |
| 20 | All as per item no- 15 here in before but 16 Sqmm 2 core |
| 21 | Supply and fixing 1100 volts grade heavy duty PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 mtr apart including 4mm dia suspension GI wire with stranded conductor 10sqmm twin core cable flat or round including taking down old unserviceable service connections complete all as specified and directed. |
| 22 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation, laying of pipe etc and not exceeding 10 sqm on plan for manhole etc and getting out in soft/loose soil, complete all as specified and directed. |
| 23 | Excavation in trenches not exceeding 1.5 mtr wide and exceeding 1.5 mtr in depth for foundation, laying of pipe etc and not exceeding 10 sqm on plan for manhole etc and getting out in soft/loose soil, complete all as specified and directed. |
| 24 | Returning , filling in , with approved excavated soil including spreading levelling watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed. |
| 25 | Removing excavated material (soils) to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 26 | Supply and laying dry burnt bricks, sub class ‘B’ old size in cable trenches, as cable protection complete all as specified and directed. |
| 27 | M&L for dry sand cushioning to under ground electric cable on layer of 08 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified in clause 19.75 of M.E.S Schedule Part-I complete all as specified and directed. |
| 28 | M&L for Cutting/Boring of road/Hard standing to a size of 30 cm in width and not exceeding 60 cm in depth for laying of protection pipe/water line/Cable including returning filling, Including spreading and providing PCC in 1:2:4 B1 using 20 mm grade stone aggregate for the top 100mm layer, complete all as specified and directed. |
| 29 | Supply and laying galvanised iron pipe 40mm bore light grade fixed to poles with steel clamps laid under road crossing, fixed to wall etc complete all as specified and directed. |
| 30 | Material and labour for P.C.C (1:3:6) type C-2 using 40 mm graded aggregate as in foundation of pole and filling of mass concrete including providing necessary form work complete all as specified and as directed. |
| 31 | M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in coping to existing and new poles including necessary form work removing the debris to a distance n.exc. 50m complete all as specified and as directed. |
| 32 | Material & Labour for fabrication of Sheet metal enclosure , powder coated of Time lite Distribution Boards for automatic Switching of street lights internally pre wired by using suitable copper lugs including fixing with MS Clamp 40X5 mm to steel/RCC poles incl connection consisting of the following (i) ASTRONOMICAL time switch 24 hrs operation 240 Volts Cat Part No.TDA45163 of Indo asian or Equivalent of Legrand/Scneider (ii)3 pole contactor 40Amps (iii) MCB FP 32 Amps |
| 33 | M&L for street light bracket made out of 32 mm dia GI pipe medium grade 120 cm long cut to size and bend to shape , fixing on poles with flat iron clamps 40mm x 6 mm – 02 sets including nuts, bolts and washers including one coat of aluminium pait over a coat of red oxide primer including taking down of old unserviceable complete all as specified. |
| 34 | M&L earthing complete with galvanised steel earth plate electrode 60cmx60cm.x6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts,nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part I 2009 connected to earthing test point, 20 mm bore medium grade GI watering pipe, 15mm bore light grade GI protection pipe, PCC chamber with RCC cover, funnel with wire mesh etc including necessary test including taking down of existing earthing, on completion all as specified and as directed. |
| 35 | Servicing of DG Set 100 KVA of any make, checking entire system as per manufacturer's catalogue such as checking all parts for serviceablility, taking down defective parts such as fuel filter assy, by pass filter assembly, lub oil filter assembly, air cleaner assy, air filter, flexible hose pipe, radiator coolent, distill water, tightening the base bolt and nuts and mounting bolts and nuts etc and replacing the same with same size, make and capacity of parts, draining out the old used burnt engine oil from the sump, cleaning all serviceable filters and oil sump with cleaning solution such as petrol/ diesel and refilling new engine oil upto required level, cleaning of battery terminals with warm water, checking the radiator and radiator hose and arresting small leaks, checking the fuel pump timing and adjusting if required and including testing to DG Set to entire satisfaction of Engr-in Charge, complete all as specified & directed. |
| 36 | Notes :- (i) Spare parts/ Engine oil/ Check kit/ filter shall be measured and paid for saperately under respective items of BOQ as 'Supply only'. (ii) Minimum 6 months gap/ 200 Hrs of run whichever is earlier shall be considered for next service. (iii) Repair guarantee for replaced parts/ servicing of DG Set shall be for six month/ 200 Hrs run from the date of service whichever is earlier.(iv) Cost of small spares required for maint of DG set shall be deemed to be included in the unit rate quoted by the contractor(v) Service Engineer must be skilled and must have knowledge of maintenance of DG sets and attending minor and major fault when it arise. |
| 37 | All as per Srl item No.35 above but DG set of capacity 62.5 KVA. |
| 38 | All as per Srl item No35 here-in-before but DG set of capacity 50 KVA. |
| 39 | All as per Srl item No.35 here-in-before but DG set of capacity 40 KVA. |
| 40 | All as per Srl item No.35 here-in-before but DG set of capacity 30 KVA. |
| 41 | All as per Srl item No.35 here-in-before but DG set of capacity 10 KVA. |
| 42 | Supply only Air filter element (OEM manufactured) suitable for 10 KVA DG set, complete all as specified & directed. |
| 43 | Supply only Air filter element (OEM manufactured) suitable for 30 KVA DG set, complete all as specified & directed. |
| 44 | Supply only Air filter element (OEM manufactured) suitable for 40 KVA DG set, complete all as specified & directed. |
| 45 | Supply only Air filter element (OEM manufactured) suitable for 50 KVA DG set, complete all as specified & directed. |
| 46 | Supply only Air filter element (OEM manufactured) suitable for 62.5 KVA DG set, complete all as specified & directed. |
| 47 | Supply only Air filter element (OEM manufactured) suitable for 100 KVA DG set, complete all as specified & directed. |
| 48 | Supply only Diesel filter (OEM manufactured) capacity 1/2 litre with 'O' ring (Primary & Secondary) suitable for 10 KVA DG set, complete all as specified & directed. |
| 49 | Supply only Diesel filter (OEM manufactured) capacity 1/2 litre with 'O' ring (Primary & Secondary) suitable for 30 KVA DG set, complete all as specified & directed. |
| 50 | Supply only Diesel filter (OEM manufactured) capacity 1/2 litre with 'O' ring (Primary & Secondary) suitable for 40 KVA DG set, complete all as specified & directed. |
| 51 | Supply only Diesel filter (OEM manufactured) capacity 1/2 litre with 'O' ring (Primary & Secondary) suitable for 50 KVA DG set, complete all as specified & directed. |
| 52 | Supply only Diesel filter (OEM manufactured) capacity 1 litre with 'O' ring (Primary & Secondary) suitable for 62.5 KVA DG set, complete all as specified & directed. |
| 53 | Supply only Diesel filter (OEM manufactured) capacity 1 litre with 'O' ring (Primary & Secondary) suitable for 100 KVA DG set, complete all as specified & directed. |
| 54 | Supply only Oil filter (OEM manufactured) capacity 1/2 litre with 'O' ring suitable for 10 KVA DG set, complete all as specified & directed. |
| 55 | Supply only Oil filter (OEM manufactured) capacity 1/2 litre with 'O' ring suitable for 30 KVA DG set, complete all as specified & directed. |
| 56 | Supply only Oil filter (OEM manufactured) capacity 1/2 litre with 'O' ring suitable for 40 KVA DG set, complete all as specified & directed. |
| 57 | Supply only Oil filter (OEM manufactured) capacity 1 litre with 'O' ring suitable for 50 KVA DG set, complete all as specified & directed. |
| 58 | Supply only Oil filter (OEM manufactured) capacity 1 litre with 'O' ring suitable for 62.5 KVA DG set, complete all as specified & directed. |
| 59 | Supply only Oil filter (OEM manufactured) capacity 1 litre with 'O' ring suitable for 100 KVA DG set, complete all as specified & directed. |
| 60 | Supply only Rocker cover / sump packing kit (OEM manufactured) suitable for 10 to 100 KVA DG set, complete all as specified & directed. |
| 61 | Supply only Fuel line (OEM manufactured) complete with clamps suitable for 10 KVA DG set, complete all as specified & directed. |
| 62 | Supply only Fuel line (OEM manufactured) complete with clamps suitable for 30 KVA DG set, complete all as specified & directed. |
| 63 | Supply only Fuel line (OEM manufactured) complete with clamps suitable for 50 KVA DG set, complete all as specified & directed. |
| 64 | Supply only Fuel line (OEM manufactured) complete with clamps suitable for 62.5 KVA DG set, complete all as specified & directed. |
| 65 | Supply only Fuel line (OEM manufactured) complete with clamps suitable for 100 KVA DG set, complete all as specified & directed. |
| 66 | Supply only Low lube oil pressure sensor (OEM manufactured) complete suitable for 10/ 30/ 40/ 50/ 62.5/ 100 KVA DG set, complete all as specified & directed. |
| 67 | Supply only Water hose pipe kit (OEM manufactured) complete with clamps, nuts & bolts suitable for 10/ 30/ 40/ 50/ 62.5/ 100 KVA DG set, complete all as specified & directed. |
| 68 | Supply only engine oil 15W/ 40, complete all as specified & directed. |
| 69 | Supply only water coolent suitable for DG set, complete all as specified & directed. |
| 70 | Supply only distilled water for filling in batteries, complete all as specified & directed. |
| 71 | Taking down/ Dismantling of unserviceable self starter 12/24 volts from engine of DG Set , opening of stator and armature for repairing by replacing the worn out carbon brushes, brush holder, bearings, ignition / solenoid coil, replacement of burnt armature, rewinding of field coils, replacement of pinion gears, bushing etc, complete servicing , varnishing of stator /armature and refixing after repair, testing / commissioning complete for DG Set of any capacity, complete all as specified & directed. |
| 72 | S&F battery terminals (positive and negative) brass heavy duty complete suitable for fixing on battery poles with bolts, nuts and washers complete including taking down old unserviceable battery terminals, complete all as specified & directed. |
| 73 | Supply, installation, testing and commissioning of maintenance free lead acid battery, 12V, 180 AH conforming to IS:7372 including dismantling of old unserviceable battery, complete all as specified & directed. |
| 74 | Supply, installation, testing and commissioning of maintenance free lead acid battery, 12V, 150 AH conforming to IS:7372 including dismantling of old unserviceable battery, complete all as specified & directed. |
| 75 | Supply, installation, testing and commissioning of maintenance free lead acid battery, 12V, 90 AH conforming to IS:7372 including dismantling of old unserviceable battery, complete all as specified & directed. |
| 76 | Draining out the existing diesel from the tank from the capacity 10 to 100 KVA DG set, kept aside for repouring, taking down the complete fuel tank of any capacity from its position after disconnecting all the fuel lines, carryout cleaning work with solutions, removing the dust and foreign materials from the tank, drying the tank, blow with air painting and carry out recaliberation of diesel tank to the specified level including replacement of PVC level pipe, refix the tank in its original position, connecting all the removed fuel connections, refilling the kept diesel back to the tank carefully, remove air from the fuel connections, start the engine and test for satisfactory function, complete all as specified & directed . |
| 77 | Disconecting the existing battery of capacity 12V 92 /100 AH from the DG set, shifting it to battery workshop, draining out the complete unserviceable sulphuric acid from the battery, filling up with new sulphuric acid to the required level, charging the battery, testing the battery for correct specific gravity, bringing back to the location, connecting to DG Set, and testing for satisfactory function, complete all as specified & directed. |
| 78 | Disconecting the existing battery of capacity 12V 150 /180 AH from the DG set, shifting it to battery workshop, draining out the complete unserviceable sulphuric acid from the battery, filling up with new sulphuric acid to the required level, charging the battery, testing the battery for correct specific gravity, bringing back to the location, connecting to DG Set, and testing for satisfactory function, complete all as specified & directed. |
| 79 | Taking down existing worn out battery charging dynamo belt & water pump fan belt (V Belt) from the following capacity of DG set installed at various installations and supply and fixing with new fan belt of same specifications, complete & specified and as directed :- |
| 80 | 10 to 40 KVA |
| 81 | 50 to 100 KVA |
| 82 | Taking down the existing turbo charger unit from the capacity 30 to 100 KVA Diesel engine, transporting to private work shop, dismantling opening including replacement of worn out bearing, bushes, fanblade, gaskets, o ring, seal etc., and reassembling testing/ connecting, complete all as specified & directed . |
| 83 | Taking down brunt unserviceable automatic voltage regulator assy from alternator of DG set by disconnecting its electrical connections, supply and fixing new AVR 12V suitable for 10 to 63 KVA DG Set including connecting all electrical connections, testing voltage after starting engine and setting properly complete all as specified & directed. |
| 84 | Disconnecting, removing and dismantling radiator assembly from the following capacity DG sets and descaling the radiator throughly with CTC solution/ any other chemical solvent agent as approved by the Engineer-in-charge, stopping of leakage at place to copper cores and tubes by brazing scrapping the existing oil paint, dusting and painting the radiator with enamelled paint etc., re-installing and commissioning complete all as specified & directed :- |
| 85 | 10 to 40 KVA |
| 86 | 50 to 100 KVA |
| 87 | Taking down existing unserviceable water pump assembly of following capacity DG sets installed at various installation and replaced with new water pump assembly (OEM Manufactured), complete all as specified & directed :- |
| 88 | 10 to 30 KVA |
| 89 | 40 to 50 KVA |
| 90 | 62.5 to 100 KVA |
| 91 | Dismantling the alternator in parts and removing the burn out copper winding coil carefully, cleaning slots and replacing the insulation paper and re-winding 'F' class copper conductor winding wire of existing size/ shape, glass sleeves of connecting leads, binding/ tightening loose coils with binding cloths, varnishing and applying the bactol on the excitor coil/ winding with supper varnish, heating the windings at appropriate tempeature to achive required insulation resistance with out damaging the other parts, replacement of driving and non-driving end bearings, cleaning, greasing, reassembling and testing with megger for insualtion resistance etc., complete all as specified and as directed :- |
| 92 | 50/62.5/100 KVA |
| 93 | 10/ 30/ 40 KVA |
| 94 | Taking down existing defective injector and fuel injection pump (FIP) for the following capacity DG set installed at various installation and replacement of worn out spares like delivery valves, nozzles, bearings, fly weight, packing kit, and copper washer kit, injector element, kit injector, retainer injector cup, fixing tappit cover packing set and recalibration of FIP and refixing in same position and testing of full load checking of pressure and adjustment by dial gauge complete all as specified and as directed :- |
| 95 | 50 to 100 KVA |
| 96 | 10/ 30/ 40 KVA |
| 97 | Dismantling of unserviceable battery charging dynamo of 12 Volts from DG set of capacity 10 KVA to 100 KVA, repair and servicing of dynomo including replacement of bushes, bearings, carbon brushes, rectifires, rewinding of field magnet coil / rotor armeture coils and any other minor parts required for smooth functioning and refixing on DG set after repair/service including testing after commissioning, complete all as specified & directed. |
| 98 | Dismantling of old unserviceable battery charging dynomo of rating 12 volts and supply and fixing new battery charging dynomo of same specifications as per existing model suitable for fixing on DG set, 1500 rpm including testing after complete installation, complete all as specified & diirected. |
| 99 | M&L for electronic type Starting Switch suitable for 10KVA to 100 KVA DG set including taking down old unserviceable switch, complete all as specified & directed. |
| 100 | M&L feed pump (OEM manufactured) suitable for 10 KVA to 100 KVA DG set including taking down old unserviceable pump, complete all as specified & directed. |
| 101 | Taking down the existing defective DC ammeter and volt meter from the panel and to be replaced with new combined DC ammeter and volt meter including necessary wiring & wiring material, complete all as specified & directed . |
| 102 | M&L engine safety unit (ESU) alongwith meter for pressure, fuel, RPM etc. with all electrical instruments and accessories including testing and taking down old unserviceable ESU, complete all as specified & directed. |
| 103 | S&F Door hinges suitable for any capacity / size of DG set canopy at different locations including taking down old unserviceable/ broken hinges, complete all as specified & directed. |
| 104 | M&L on load change over switch in sheet metal enclosure, 100 Amps, 415 volts, 4 pole, modular type, positive isolation, door interlock & padlock facility, conforming to IS:13947 (Part-3); IEC:60947-3 including all connecting/ jointing materials & taking down old unserviceable change over switch, complete all specified & directed. |
| 105 | M&L on load change over switch in sheet metal enclosure, 160 Amps, 415 volts, 4 pole, modular type, positive isolation, door interlock & padlock facility, conforming to IS:13947 (Part-3); IEC:60947-3 including all connecting/ jointing materials & taking down old unserviceable change over switch, complete all specified & directed. |
| 106 | M&L on load change over switch in sheet metal enclosure, 200 Amps, 415 volts, 4 pole, modular type, positive isolation, door interlock & padlock facility, conforming to IS:13947 (Part-3); IEC:60947-3 including all connecting/ jointing materials & taking down old unserviceable change over switch, complete all specified & directed. |
| 107 | M&L MCCB of capacity 63 Amps, 4 pole, 415volt, 50Hz, breaking capacity 16 KA (minimum) or higher, adjustable thermal and fixed magnetic release, complete as per OEM standard design including taking down old unserviceable MCCB, complete all as specified & directed. |
| 108 | Material and labour servicing and cleaning of oil cooled servo voltage stabilizer 40-50KVA by transporting to workshop , carefully lifting of core from the tank by opening cover, cleaning of tank, removing of sediments, cleaning of coils/ electrical connections, filtration of transformer oil ,fixing the core back in the tank, making electrical connections by replacing the consumble spares such as gaskets, rubber oil seals complete etc but other spares as listed here-in-after shall be replaced and cost of spare parts as\\" supply only shall be measured and paid separately under relevent item iron padling back at work site ,working electrical coinnection all complete as directed by Engr-in-charge capacity servo voltage stabilizer 100 KVA single/ 3 phase. Note: (i) Spare parts required to make serviceable of above oil cooled sevo voltage stabilizer shall be measured and paid separately under relevant item here-in-after.(ii) Rewinding of barrier assembly and transformer assembly will be measured and paid separately.) |
| 109 | Supply only the following spare parts / components to be incorporated against serial item No 108 here in before |
| 110 | copper Dimmer stat 40A |
| 111 | Servo Motor 3KG with RC network |
| 112 | Carbon brush 40A with holder |
| 113 | Controlling circuit |
| 114 | Aluminium arm set 32A |
| 115 | (f)pipe bush |
| 116 | (g)current collector plate copper |
| 117 | indicating lamps |
| 118 | Toggle switch |
| 119 | Voltmeter 0-500V |
| 120 | Input Output connection busbar with bakelite |
| 121 | Fresh transformer oil(top up) Please Enable Macros to View BoQ information |