| Sl. No. | Item Description |
| 1 | Repair,maint including comprehensive preventive maintenance of DG set, including replacement of defective parts, filters, V-belt etc, decanning of the used engine oil from DG set by opening of drain out plug/nuts, cleaning of engine oil sump complete and refilling of new approved grade of engine oil as per requirement. Complete inspection and cleaning of DG set and rectified the all defects, tightening the all nuts, bolts, moving parts etc complete all as specified and directed of the following capacity.Notes : (i) Spare parts, 'V' - Belt, Filters, Air cleaner, hose, Engine Oil etc shall be measured and paid separately. (ii) Any Minor items like washer, gasket, nuts, bolts, 'O' Ring etc other than spare parts maintained in the respective Sch if required during maintenance of work, they shall be provided by the contractor and rate deemed to be included in the item rate for which no extra payment shall be paid.(iii) Periodicity of maintenance of DG set shall be carried out as per following instruction :(a) by check oil level and quality (Every 50-100 hours or as recommended by manufacturer)(b) Inspect air fltrer (Every 100 - 200 hours or as recommended by manufacturer)(c) Check fuel system (Every 100 -200 hours or as recommended by manufacturer)(d) Inspect cooling system (every 200 - 500 hours or as recommended by manufacturer). |
| 2 | (e) Check battery (every 200 - 500 hours or as recommended by manufacturer)(f) Inspect exhaust (every 500 - 1000 hours or as recommended by manufacturer)(g) Check electrical system (every 500 - 1000 hours or as recommended by manufacturer)(h) Load test (every 500 - 1000 hours or as recommended by manufacturer)(j) Inspect engine and generator mounts (every 500 - 1000 hours or as recommended by manufacturer)(h) Perform general inspection (every 1000 - 2000 hours or as recommended by manufacturer) and when required/ directed by Engr-in-Charge. Measurement shall be carried out as per maint carried out by the Contractor.(iv) Maint shall be carried out in the present of Engr-in-charge/Rep of Engr-in-charge.(v) Maint shall be carried out through service centre of original equipment manufacturers/Auth Service centre of DG set. (vi) All tool and plants shall be provided by the contractor.(vii) Contractor shall maintain proper documents of DG set wise pertains to maint carried out and submitted to the Engr-in-charge as & when maint carried out. |
| 3 | (a) Capacity of DG Sets 160 KVA. |
| 4 | (b) Capacity of DG Sets 100/125 KVA. |
| 5 | (c) Capacity of DG Sets 30/35 KVA. |
| 6 | (d) Capacity of DG Set upto 15 KVA. |
| 7 | Repair / Maint of existing control panel of DG Set by replacing the connected items such as Connectors, leads, copper wire, thimble, digital multifunction meter, control wiring etc along with any other items requierd to be replaced as directed by E-in-Charge. |
| 8 | M&L for cleaning of fuel tank of DG sets of any make and capacity including replacement of fuel level indicating tube and markings complete all as specified and directed. |
| 9 | Replacement of flame proof asbestos rope of specified dia wrapped around the exhaust pipe complete all as specified and directed. |
| 10 | Taking out unserviceable charging alternator from 100 KVA to 160 KVA DG set and removing starter and rotor, removing old burnt out winding wire and rewinding the stator of suitable size with super enameled copper wire and insulating materials complete including re-assembling the complete alternator, fixing in position and testing on load complete including replacement of bearing of suitable size – 01 Set complete all as specified and directed. |
| 11 | S&F, in replacement battery charger SMPS compatible with existing arrangement, 12 volt, 10 Amp complete all as specified and directed by engr-in-charge. |
| 12 | S&F, in replacement battery charger SMPS compatible with existing arrangement, 24 volt, 10 Amp complete all as specified and directed by engr-in-charge. |
| 13 | Repair & Replacement of Metal Radiator Fan Blade for 100KVA to 160 KVA DG set as per sample complete all as specified and directed. |
| 14 | Repair/ Over hauling of self starter assembly of any type/make/model including of basic servicing/ cleaning, starter motor overhauling, overhauling with carbon brush and bush,solenoid/ armature repair etc complete as required for proper functioning complete for 15 KVA to 35 KVA capacity of DG sets all as specified and Directed by E-in-Charge. |
| 15 | Repair/ Over hauling of self starter assembly of any type/make/model including of basic servicing/ cleaning, starter motor overhauling, overhauling with carbon brush and bush,solenoid/ armature repair etc complete as required for proper functioning complete for 100 KVA to 160 KVA capacity of DG sets all as specified and Directed by E-in-Charge. |
| 16 | Repair and servicing of Radiator including radiator removal from DG set, internal chemical flushing/descaling, external air pressure cleaning of fins, leak testing, welding/ soldering if leakeage founded, coolant refilling and Re-assemble the same in Original Position with new gaskets, hoses and clamps complete all as directed by E-in-Charge. for 15 KVA to 35 KVA capacity DG Sets. Note: Parts shall be measured and paid seperately in respective items |
| 17 | Repair and servicing of Radiator including radiator removal from DG set, internal chemical flushing/descaling, external air pressure cleaning of fins, leak testing, welding/ soldering if leakeage founded, coolant refilling and Re-assemble the same in Original Position with new gaskets, hoses and clamps complete all as directed by E-in-Charge. for 15 KVA to 35 KVA capacity DG Sets. Note: Parts shall be measured and paid seperately in respective items |
| 18 | Repair / over hauling of automatic/manual, governor assembly of any capacity/make/type/model complete including overhauling with spare parts replacement like spring, linkage, actuator parts complete all as specified and directed |
| 19 | Reconditioning Battery of any capacity upto 180 AH by replacing all cells, Battery terminals posts, plate repair, acid change etc all as required including charging etc for proper functioning for one year (Guaranteed Service) |
| 20 | Repair/over hauling servicing of dynamo assembly of any make/type/rewinding of armature and field coil including replacement of bearing/bushing, carbon bush etc all as required to make dynamo 100% serviceable. |
| 21 | S&F, in repair, indicator lamp LED type as per existing complete all as specified & directed by E-in-Chrage |
| 22 | S&F, in repair, Selector switch three pole knob of any make/capacity complete all as specified & directed by E-in-Chrage. |
| 23 | S&F batteries for DG Sets Factory charged with SMPS Charger built in sealed maintenance free generator starting system euivalent to 01x12 Volts 170 AH/180 AH red, green and yellow for charging indicator process built in battery body with warranty of 36 months complete all as specified & directed by E-in-Chrage and visit at site before precurement |
| 24 | S&F in repair change over switch manual of rating upto 160A 4-pole for DG set of any approved make and capacity all as specified and directed by Engr-in-charge. |
| 25 | S&F, in repair, Automatic Tansfer Switch(ATS) for upto 100 kVA DG setwithcurrent rating upto 160A with system voltage 415 V AC and frequency 50Hz control voltage 24 V DC and protection class IP42(Indoor) of approved make all as specified and directed by Engr-in-charge |
| 26 | Taking out of defective automatic voltage requlator (AVR) of DG set (alternator side) of 15 KVA to 35 KVA of capacity of any make and supply and fix New automatic voltage regulator (AVR) including necessary connection, testing and cable work etc complete all as directed by E-in-Charge for the foolowing: |
| 27 | Taking out of defective automatic voltage requlator (AVR) of DG set (alternator side) of 100 KVA to 160 KVA of capacity of any make and supply and fix New automatic voltage regulator (AVR) including necessary connection, testing and cable work etc complete all as directed by E-in-Charge for the foolowing: |
| 28 | Supply & fill the compatible engine oil for the DG set 15W40 complete all as specified and directed by Engr-in-charge. |
| 29 | Supply & fill coolent complete all as specified and directed by Engr-in-charge. |
| 30 | Supply only the following spare parts for DG set 160KVA and labour should be included in Sl No. 1.01 here in before as per existing Make. |
| 31 | (a) Oil drain valve |
| 32 | (b) Hose plain |
| 33 | (c) Water Pump |
| 34 | (d) Vibration damper |
| 35 | (e) Piston Ring |
| 36 | (f) Air filter element |
| 37 | (g) Screw, Hex flange Head Cap |
| 38 | (h) Expansion plug |
| 39 | (j) Bushing |
| 40 | (k) Vibration damper |
| 41 | (l) Belt, V Ribbed |
| 42 | (m) Seal, Rectangular Ring |
| 43 | (o) Gasket, Gear cover |
| 44 | (p) Valve Intake |
| 45 | (q) Valve exhaust |
| 46 | (r) Coil cooler |
| 47 | (s) Gasket, Thm housing cover |
| 48 | (t) Fuel filter |
| 49 | (u) Sealant liquid gasket |
| 50 | (v) Upper Gasket |
| 51 | (w) Lower gasket |
| 52 | (x) Screw hexagon Head Cap |
| 53 | (y) Lubricating oil pump |
| 54 | (z) Lub oilfilter catridge |
| 55 | (ab) Thermostat |
| 56 | (ac) Hose, Elbow |
| 57 | (ad) Bearing, connecting rod |
| 58 | (ae) Main bearing |
| 59 | (af) Fuel strainer |
| 60 | (ag) Gear, fly wheel Ring |
| 61 | (ah) Piston Kit |
| 62 | (aj) Fuel water separater |
| 63 | (ak) Hose clamp |
| 64 | (al) Corrosion inhibitor |
| 65 | (am) Vibration damper |
| 66 | Supply only the following spare parts for DG set 100/125 KVA and labour should be included in Sl No. 1.02 here in before as per existing Make. |
| 67 | (a) Oil drain valve |
| 68 | (b) Hose plain |
| 69 | (c) Water Pump |
| 70 | (d) Turbo repair kit |
| 71 | (e) Piston Ring |
| 72 | (f) Air filter element |
| 73 | (g) Screw, Hex flange Head Cap |
| 74 | (h) Expansion plug |
| 75 | (j) Bushing |
| 76 | (k) Belt, V Ribbed |
| 77 | (l) Seal, Rectangular Ring |
| 78 | (m) Gasket, Gear cover |
| 79 | (n) Valve Intake |
| 80 | (o) Valve exhaust |
| 81 | (p) Coil cooler |
| 82 | (q) Gasket, Thm housing cover |
| 83 | (r) Fuel filter |
| 84 | (s) Sealant liquid gasket |
| 85 | (t) Upper Gasket |
| 86 | (u) Lower gasket |
| 87 | (v) Salvage sleev |
| 88 | (w) Lubricating oil pump |
| 89 | (x) Lub oil filter catridge |
| 90 | (y) Int manifold Cover gasket |
| 91 | (z) Thermostat |
| 92 | (aa) Hose, Elbow |
| 93 | (ab) Bearing, connecting rod |
| 94 | (ac) Main bearing |
| 95 | (ad) Fuel strainer |
| 96 | (ae) Gear, fly wheel Ring |
| 97 | (af) Piston Kit |
| 98 | (ag) Fuel water separater |
| 99 | (ah) Hose clamp |
| 100 | (aj) Corrosion inhibitor |
| 101 | (ak) Vibration damper |
| 102 | Supply only the following spare parts for DG set 30/35 KVA and labour should be included in Sl No. 1.03 here in before as per existing Make. |
| 103 | (a) Oil drain valve |
| 104 | (b) Hose plain |
| 105 | (c) Water Pump |
| 106 | (d) Turbo repair kit |
| 107 | (e) Piston Ring |
| 108 | (f) Air filter element |
| 109 | (g) Screw, Hex flange Head Cap |
| 110 | (h) Expansion plug |
| 111 | (j) Bushing |
| 112 | (k) Belt, V Ribbed |
| 113 | (l) Seal, Rectangular Ring |
| 114 | (m) Gasket, Gear cover |
| 115 | (n) Valve Intake |
| 116 | (o) Valve exhaust |
| 117 | (p) Coil cooler |
| 118 | (q) Gasket, Thm housing cover |
| 119 | (r) Fuel filter |
| 120 | (s) Sealant liquid gasket |
| 121 | (t) Upper Gasket |
| 122 | (u) Lower gasket |
| 123 | (v) Salvage sleev |
| 124 | (w) Lubricating oil pump |
| 125 | (x) Lub oilfilter catridge |
| 126 | (y) Int manifold Cover gasket |
| 127 | (z) Thermostat |
| 128 | (aa) Hose, Elbow |
| 129 | (ab) Bearing, connecting rod |
| 130 | (ac) Main bearing |
| 131 | (ad) Fuel strainer |
| 132 | (ae) Gear, fly wheel Ring |
| 133 | (aj) Piston Kit |
| 134 | (ak) Fuel water separater |
| 135 | (al) Hose clamp |
| 136 | (am) Corrosion inhibitor |
| 137 | (an) Vibration damper |
| 138 | Supply only the following spare parts for DG set upto 15 KVA nd labour should be included in Sl No. 1.04 here in before as per existing Make. |
| 139 | (a) Oil drain valve |
| 140 | (b) Hose plain |
| 141 | (c) Water Pump |
| 142 | (d) Turbo repair kit |
| 143 | (e) Piston Ring |
| 144 | (f) Air filter element |
| 145 | (g) Screw, Hex flange Head Cap |
| 146 | (h) Expansion plug |
| 147 | (j) Bushing |
| 148 | (l) Belt, V Ribbed |
| 149 | (m) Seal, Rectangular Ring |
| 150 | (o) Gasket, Gear cover |
| 151 | (p) Valve Intake |
| 152 | (q) Valve exhaust |
| 153 | (r) Coil cooler |
| 154 | (s) Gasket, Thm housing cover |
| 155 | (t) Fuel filter |
| 156 | (u) Sealant liquid gasket |
| 157 | (v) Upper Gasket |
| 158 | (w) Lower gasket |
| 159 | (x) Salvage sleev |
| 160 | (y) Lubricating oil pump |
| 161 | (z) Lub oilfilter catridge |
| 162 | (aa) Int manifold Cover gasket |
| 163 | (ab) Thermostat |
| 164 | (ac) Hose, Elbow |
| 165 | (ad) Bearing, connecting rod |
| 166 | (ae) Main bearing |
| 167 | (af) Fuel strainer |
| 168 | (ag) Gear, fly wheel Ring |
| 169 | (af) Piston Kit |
| 170 | (ag) Fuel water separater |
| 171 | (ah) Hose clamp |
| 172 | (aj) Corrosion inhibitor |
| 173 | (ak) Vibration damper |
| 174 | S&F in repair starting flywheel gear & starter gear matching with plates of same type and make (Kirloskar/Cummins) for DG set of capacity 100 KVA all as specified and directed by Engr-in-charge |
| 175 | M and L for repair to gate of DG set canopy by fixing suitable hinges complete all as specified and directed by Engr-in-charge |
| 176 | M&L for dismantling, existing fuel pump assy from 06 cylinders, water cooled Engine, of Make : Kirloskar/ cummins, (DG SET 100 KVA) over hauling/calbiration by replacement of injector nozzle tips-06 Nos, pressure timing spring, piston plunger, gear pinion, solenoid valve and testing complete all as specified and as directed. |
| 177 | M&L for dismantling, existing fuel pump assy from 06 cylinders, water cooled Engine, of Make : Kirloskar/ cummins, (DG SET 160 KVA) over hauling/calbiration by replacement of injector nozzle tips-06 Nos, pressure timing spring, piston plunger, gear pinion, solenoid valve and testing complete all as specified and as directed. |
| 178 | Repair and Replacement of battery terminal including apply petroleum jelly on terminal after cleaning of brass suitable for 12V, 180 AH battery complete all as specified and directed. |
| 179 | Dismantling the electric induction motor AC 3 Phase, capacity upto 5 HP, irrespective make and type from the foundation and sump after disconnecting electric cable connection, lifting from sump /foundation and earthing etc. and transportation to civil workshop for repair, if required, for overhauling the motor duly painted with two coats of synthetic enamel paint of existing shed and re-assembling the complete motor and installing at site with electric cable connection for its serviceability up to entire satisfaction of Engineer-in-charge.Note:- (i) Cost of copper wire, T&P, minor repair incl minor spare included in this item. |
| 180 | Dismantling the electric induction motor AC 3 Phase, capacity upto 10 HP, irrespective make and type from the foundation and sump after disconnecting electric cable connection, lifting from sump /foundation and earthing etc. and transportation to civil workshop for repair, if required, for overhauling the motor duly painted with two coats of synthetic enamel paint of existing shed and re-assembling the complete motor and installing at site with electric cable connection for its serviceability up to entire satisfaction of Engineer-in-charge.Note:- (i) Cost of copper wire, T&P, minor repair incl minor spare included in this item. |
| 181 | Dismantling the electric induction motor AC 3 Phase, capacity upto 15 HP, irrespective make and type from the foundation and sump after disconnecting electric cable connection, lifting from sump /foundation and earthing etc. and transportation to civil workshop for repair, if required, for overhauling the motor duly painted with two coats of synthetic enamel paint of existing shed and re-assembling the complete motor and installing at site with electric cable connection for its serviceability up to entire satisfaction of Engineer-in-charge.Note:- (i) Cost of copper wire, T&P, minor repair incl minor spare included in this item. |
| 182 | Disconnecting Air Blower of capacity 20 HP of make siemen (Twin lobe blower, suction cap 500 M3/hr, suction pressure atmosphere, suction temp ambient, discharge pressure 0.5/kg cm2, blower speed 1400 RPM, BHP at duty point 15.8 BHP, motor 20HP/1500 RPM, Drive V blet, cooling Air cooled, duty continueous, rotation clockwise, lub oil viscocity -ISO-VG 320/ servosystem, Suitable std elect motor) the foundation and disconnection of motor, all electric cable connection and earthing etc. and transportation to civil workshop if required and over hauling includign changing of necessary parts, greasing, painting, oiling and re-assembling the complete set & re-installation fo blower set at site with existing electric cable connection for its serviceability up to entire satisfaction of Engineer-in-charge .Note:- (i) Cost of M&L, T&P, greasing, oiling & other minor spare is included in this item. Nothing extra shall be paid on this account. (ii) Major parts to be measured and paid separately under respective sch of items. |
| 183 | Material and Labour for surface cleaning and application of two coats of enamel paint of suitable colour directed by engr-in-charge on induction motors/ non clog submersible pump of size upto 20 HP including necessary preparation and finishing all as directed by engr in charge |
| 184 | Repair,maint including comprehensive preventive maintenance of induction motor/ non clog submersible pump of capacity upto 5 HP including replacement of defective parts, check motor oil or moisture, inspection of foundation bolts and mounting alignment, check fan cover and cooling fan condition, Inspection of coupling and shaft alignment, check terminal connections for looseness or overheating, inspection of terminal box gasket and insulation,check phase voltage and current balance, inspection of erthing connection, inspection of motor bearing for noise or vibrations,inspection of shaft and coupling for wear,ensure roror rotates freely without abnormal noise, check bearing grease condition( add recommended grease if required), clean cleaning fan blades, ensure fan gurad is intact, clean motor with dry compressed air or brush rectifed all defects all as directed by engr in charge.Note:- (a) Maint shall be carried out in the present of Engr-in-charge/Rep of Engr-in-charge.(b)Maint shall be carried out through Auth Service centre and major parts payment will be paid separately. (c) All tool and plants shall be provided by the contractor.(d) Contractor shall maintain proper documents of DG set wise pertains to maint carried out and submitted to the Engr-in-charge as & when maint carried out. |
| 185 | Repair,maint including comprehensive preventive maintenance of induction motor/ non clog submersible pump of capacity upto 10 HP including replacement of defective parts, check motor oil or moisture, inspection of foundation bolts and mounting alignment, check fan cover and cooling fan condition, Inspection of coupling and shaft alignment, check terminal connections for looseness or overheating, inspection of terminal box gasket and insulation,check phase voltage and current balance, inspection of erthing connection, inspection of motor bearing for noise or vibrations,inspection of shaft and coupling for wear,ensure roror rotates freely without abnormal noise, check bearing grease condition( add recommended grease if required), clean cleaning fan blades, ensure fan gurad is intact, clean motor with dry compressed air or brush rectifed all defects all as directed by engr in charge.Note:- (a) Maint shall be carried out in the present of Engr-in-charge/Rep of Engr-in-charge.(b)Maint shall be carried out through Auth Service centre and major parts payment will be paid separately. (c) All tool and plants shall be provided by the contractor.(d) Contractor shall maintain proper documents of DG set wise pertains to maint carried out and submitted to the Engr-in-charge as & when maint carried out. |
| 186 | Repair,maint including comprehensive preventive maintenance of induction motor/ non clog submersible pump of capacity upto 15 HP including replacement of defective parts, check motor oil or moisture, inspection of foundation bolts and mounting alignment, check fan cover and cooling fan condition, Inspection of coupling and shaft alignment, check terminal connections for looseness or overheating, inspection of terminal box gasket and insulation,check phase voltage and current balance, inspection of erthing connection, inspection of motor bearing for noise or vibrations,inspection of shaft and coupling for wear,ensure roror rotates freely without abnormal noise, check bearing grease condition( add recommended grease if required), clean cleaning fan blades, ensure fan gurad is intact, clean motor with dry compressed air or brush rectifed all defects all as directed by engr in charge.Note:- (a) Maint shall be carried out in the present of Engr-in-charge/Rep of Engr-in-charge.(b)Maint shall be carried out through Auth Service centre and major parts payment will be paid separately. (c) All tool and plants shall be provided by the contractor.(d) Contractor shall maintain proper documents of DG set wise pertains to maint carried out and submitted to the Engr-in-charge as & when maint carried out. |
| 187 | Supply only the following spare parts for electric induction motor upto 5 HP and labour should be included in Sl No. 36.01 here in before. |
| 188 | (a) Ball bearings (6202/6203/6204) |
| 189 | (b) Cooling fan |
| 190 | (c) Fan cover/ guard |
| 191 | (d) Terminal block/ terminal plate |
| 192 | (e)Terminal Box |
| 193 | (f) Shaft Key |
| 194 | (g) Oil seal/ Grease seal |
| 195 | (h) Motor Shaft |
| 196 | (j) End Cover/ End Sheild |
| 197 | (k) stator rewinding Copper |
| 198 | (l) Rotor |
| 199 | (m) Star coupling |
| 200 | Supply only the following spare parts for Non clog submersible pump upto 5 HP and labour should be included in Sl No. 36.01 here in before.. |
| 201 | (a) Impeller Stainless steel |
| 202 | (b) Mechanical seal ( Tungsten/Carbon) |
| 203 | (c) Ball Bearing (heavy duty) |
| 204 | (d) Pump shaft (stainless steel) |
| 205 | (e) Wear ring/ Neck Ring |
| 206 | (f) Oil seal/ O-ring |
| 207 | (g) Pump casing/ Volute |
| 208 | (h) Guide bush/ sleeve |
| 209 | (j) Strainer/ Suction cover |
| 210 | (k) Motor Winding (Rewinding) |
| 211 | (l) Cable gland |
| 212 | Supply only the following spare parts for Non clog submersible pump upto 10 HP and labour should be included in Sl No. 36.02 here in before.. |
| 213 | (a) Impeller Stainless steel |
| 214 | (b) Mechanical seal ( Tungsten/Carbon) |
| 215 | (c) Ball Bearing (heavy duty) |
| 216 | (d) Pump shaft (stainless steel) |
| 217 | (e) Wear ring/ Neck Ring |
| 218 | (f) Oil seal/ O-ring |
| 219 | (g) Pump casing/ Volute |
| 220 | (h) Guide bush/ sleeve |
| 221 | (j) Strainer/ Suction cover |
| 222 | (k) Motor Winding (Rewinding) |
| 223 | (l) Cable gland |
| 224 | Supply only the following spare parts for Non clog submersible pump upto 15 HP and labour should be included in Sl No. 36.03 here in before.. |
| 225 | (a) Impeller Stainless steel |
| 226 | (b) Mechanical seal ( Tungsten/Carbon) |
| 227 | (c) Ball Bearing (heavy duty) |
| 228 | (d) Pump shaft (stainless steel) |
| 229 | (e) Wear ring/ Neck Ring |
| 230 | (f) Oil seal/ O-ring |
| 231 | (g) Pump casing/ Volute |
| 232 | (h) Guide bush/ sleeve |
| 233 | (j) Strainer/ Suction cover |
| 234 | (k) Motor Winding (Rewinding) |
| 235 | (l) Cable gland |
| 236 | M&L for repair of filter press with Electro Mechanical Plate Shifting Device Plates type Filter Press of SIZES 1200 X 1200 mm for 7 bar Filtration Pressure with hydraulic closing devices.Moc of Filter Element : Polypropylene Cast Iron, SS 304, SS 316 Liquid Holding capacity - 55 Lit Moc of Skeleton : Cast Iron or Mild Steel incl all necessary spare parts and accessories to make it serviceable complete all as specified and directed by Engr-in-charge |
| 237 | M&L in repair of starter panel by checking and fault finding by replacing the connected items such as Connectors, leads, copper wire, thimble, control wiring, replacement of contactor if required, Replacement of overload relay, Replacement of push button/ selector switch, servicing of all items like MCCB, Contactor, relays etc and refix the same duly cleaning/removing carbon etc scaling from Panel existed at STP and Sewage Pump House complete all as specified and as directed.Note : (i) MCCB, Contactor, relays etc measured and paid separately. cost of minor parts like thimble, MCBs upto 32A and labour charges included in this item. No extra cost to be paid for this. |
| 238 | Supply and fixing in repair MCCB, 25 to 100Amp as per site requirement, 415 Volts, TP, 50 cycle, breaking capacity 16KA complete all as directed. |
| 239 | Supply and fixing in repair MCCB, 160 Amp 415 Volts, TP, 50 cycle, breaking capacity 36KA complete all as directed. |
| 240 | Supply and fixing in repair MCCB, 200 Amp 415 Volts, TP, 50 cycle, breaking capacity 36KA complete all as directed. |
| 241 | Supply only in repair of power Contactors 415 volts, 50 cycles, 3 phase, current rating 25 Amp (Make: BCH electric Ltd/C&S / L&T) and labour should be included in item Sl No. 40 of here in before complete all as directed. |
| 242 | Supply only in repair power Contactors 415 volts, 50 cycles,3 phase, current rating upto 32 Amp for any star delta panel in STP, Seawage pump house ( Make : C&S / L&T/BCH electric Ltd) and labour should be included in item Sl No. 40 of here in before complete all as directed. |
| 243 | Supply only in repair of Thermal overload relay(OLR) adjustable uptoabout 11 Amp of make (L&T,Schneider, Siemens ) and labour should be included in item Sl No. 40 of here in before complete all as directed |
| 244 | Supply only in repair of Thermal overload relay(OLR) adjustable upto about 32 Amp of make (L&T,Schneider, Siemens ) and labour should be included in item Sl No. 40 of here in before complete all as directed |
| 245 | Supply only in repair of timer switch for starter panel timer range upto 0-60 Seconds and labour should be included in item Sl No. 40 of here in before complete all as directed |
| 246 | Supply and Fix in repair Digital multi function meter for star delta starter panel all as directed by E-in-Charge. |
| 247 | Supply and fix in repair copper cable multi stranded 4 Sqmm, 3 core including connection and testing complete all as directed. |
| 248 | Supply and fix in repair copper cable multi stranded 6 Sqmm, 3 core including connection and testing complete all as directed. |
| 249 | M&L for cleaning of underground RCC sewage sump of 16 mtrs deep by mechanical means, 12 mtrs internal dia, dewatering, taking out sludge/mud from the sump, rubbing, scraping all around vertical walls, floor, cleaning with fresh water, applying two coat of white wash on outer exposed sufaces of wall and floor including thrown away the sludge/mud, out side of the MD land, complete all as specified and as directed |
| 250 | M&L for cleaning of underground RCC sewage sump of 12 mtrs deep by mechanical means, 5.5 mtrs internal dia, dewatering, taking out sludge/mud from the sump, rubbing, scraping all around vertical walls, floor, cleaning with fresh water, applying two coat of white wash on outer exposed sufaces of wall and floor including thrown away the sludge/mud, out side of the MD land, complete all as specified and as directed |
| 251 | M&L for cleaning of underground RCC sewage sump/ collection tank of 9 mtrs deep by mechanical means, 5 mtrs internal dia, dewatering, taking out sludge/mud from the sump, rubbing, scraping all around vertical walls, floor, cleaning with fresh water, applying two coat of white wash on outer exposed sufaces of wall and floor including thrown away the sludge/mud, out side of the MD land, complete all as specified and as directed |
| 252 | Cleaning and removing sludge from walls /floor of one Nos Equilization tank/Aeration with the help of pressure jet pump & other required equipments and depositing, applying two coat of white wash on outer exposed sufaces of wall and floorwhere directed by Engineer - in - Charge at a distance 100 mtr away from outer wall of STP and white wash to walls complete all as directed by Engineer-in-Charge. |
| 253 | M&L for Cleaning and removing of sludge from walls/floor of tube settler tank off size 4.6 Mtr x 3.5 Mtr after taking out with the help of pressure jet pump & other required equipments and depositing where directed at a distance 100 mtr away from outer wall of STP including taking out old rusted wire mesh of sizes from tube settler media and replacement of the old tube settler with new tube settler media of length 750mm/ 1000 mm after all cleaning fixing wire mesh of same size with the tube settler and fixed in original position in the tube settler tank complete all as directed . |
| 254 | Cleaning,removing and bailing out stagnated sewage or sludge from walls/floor and any light particle with the help of pressure jet pump & other required equipments from MBBR/FAB Reactor reactor inner surface off sizes and taking out damaged and unbroken MBBR media without any damage and refilling it in each MBBR with old unbroken media cleaning of inner and outer surface of MS pipe placed in MBBR and removing any sludge particle from it to entire satisfaction of Engineer-in-Charge.Note : New media for topping up will be paid and measured separately under respective item of BOQ. |
| 255 | M&L for cleaning of closed treated water storage of 1 Lakh capacity by mechanical means, 5 mtrs internal dia, dewatering, taking out sludge/mud from the sump, rubbing, scraping all around vertical walls, floor, cleaning with fresh water, applying two coat of white wash on outer exposed sufaces of wall and floor including thrown away the sludge/mud, out side of the MD land, complete all as specified and as directed. Note- All T&P and safety measure kit for deployed workers shall be arranged by the contractor. |
| 256 | Hiring of Special T and P (e.g JCB etc) for lifting of Heavy pipes/ Pumps/Motor and removal of grass/ cleaning of STP and Sewage pump house are complete all as specified and directed by Engr-in-Charge |
| 257 | Inspection, fault finding and servicing of online water monitoring system of existing make installed in STP all as directed by Engr in charge |
| 258 | Supply only the following spare parts for Online water monitoring system and labour should be included in item Sl No 61 here in before |
| 259 | PH sensor/ Probe |
| 260 | TSS Sensor |
| 261 | Controller /transmitter for calibration |
| 262 | Signal cable, connector and wiring |
| 263 | Supply and fix voltage stabilizer for online water monitoring system with capacity upto 500VA, Input voltage : 130V to 290 V, outut voltage : 220V to 240V regulated, current rating :2 A to 4A with features of time delay system, LED indicator all as specified and directed by engr in charge |
| 264 | Testing of Raw Sewage Water (Inlet) parameters like BOD, COD, TSS, FC, pH, Total N, Coliform, E-Coli, Oil & Grease, Helminth Egg, Phosphorus as P from Government approved Lab/NABL approved Lab including proper collection sample in presence of all concerned. The transportation charges and all other expenses are deemed to be included in this rate. No extra charges are given to the bidder. |
| 265 | Testing of Treated Sewage Water (outlet) parameters like BOD, COD, TSS, FC, pH, Total N, Coliform, E-Coli, Oil & Grease, Helminth Egg, Phosphorus as P from Government approved Lab/NABL Lab including proper collection sample in presence of all concerned. The transportation charges and all other expenses are deemed to be included in this rate. No extra charges are given to the bidder. |
| 266 | M&L for repair of fire fighting pump 3 phase, 415 V supply, 15 HP Squirrel cage Induction motor fan cooled type 900 LPM and 35 m Head incl replacement of UNSV parts, copper winding etc to make it serviceable complete all as specified and direcetd by Engr-in-charge. |
| 267 | Supply and fix typical industrial online pH meter with range 0 - 14, accuracy + 0.01,, output signal 4- 20mA, Diplay Digital LCD, Power supply 230VAC, with IP 65 weatherproof, field mounted, sensor type: Glass elctrode with epoxy body , cable length of 5 mtr all as specified and directed by engr in charge |
| 268 | Supply and fixing of compact type chain pulley block with minimum 2 Ton capacityheavy duty manual chain of length 15 mtr hoist with alloy steel load chain hoist with alloy steel load chain, Heavy duty Geared Travelling Trolley suitable for lifting pumps and equipment in STP/ sewage pump house all as directed by engr in charge |
| 269 | Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, burieddirectly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected tousing galvanised iron strip 25x4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as specified and directed by engr-in-charge |
| 270 | Supply, laying, connecting, jointing and testing of uPVC pipes B class laid in trenches conforming to IS 13592 with minimum pressure rating 10 kgf/cm2 incl all fittings complete all as specified and as directed of 40mm size of pipe complete all as speicified and directed. |
| 271 | Supply, laying, connecting, jointing and testing of uPVC pipes B class laid in trenches conforming to IS 13592 with minimum pressure rating 10 kgf/cm2 incl all fittings complete all as specified and as directed of 50mm size of pipe complete all as speicified and directed. |
| 272 | Supply, laying, connecting, jointing and testing of uPVC pipes B class laid in trenches conforming to IS 13592 with minimum pressure rating 10 kgf/cm2 incl all fittings complete all as specified and as directed of 90mm size of pipe complete all as speicified and directed. |
| 273 | Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth, for taking out water pipes, etc in Soft/loose soil all as specified and directed by Engr-in-Charge. |
| 274 | Returning, filling in, including spreading, leveling, watering and well ramming in layer not exc 25 cm with soil obtained from excavation all as specified and directed by Engr-in-Charge. |
| 275 | Removing excavated material (Soil) not exc 50 mtr and depositing where directed by Engr-in-Charge at a level not exc. 1.5 m above the starting point. |
| 276 | Supply and fix cable tray on 100mm length 50mm depth 16 gauge with MS angle iron 50mm x 50mm x 6mm c- frame post support grouted in ground min 30 cm ,above the ground 35 cm including PCC 1:3:6 type C-1 all as specified and directed by engr-in-charge. |
| 277 | Supply and fix cable tray on 150 mm length 50mm depth 16 gauge with MS angle iron 50mm x 50mm x 6mm c- frame post support grouted in ground min 30 cm ,above the ground 35 cm including PCC 1:3:6 type C-1 all as specified and directed by engr-in-charge. |
| 278 | Horizontal drilling in any type of soil using trenchless technology suitable for insertion of GI pipe and LT cable along the pipe of size complete all as specified and directed of 50mm dia GI Pipe complete all as specified and directed. |
| 279 | Horizontal drilling in any type of soil using trenchless technology suitable for insertion of GI pipe and LT cable along the pipe of size complete all as specified and directed of 100mm dia GI Pipe complete all as specified and directed. |
| 280 | Supply and fixing in repair for sluice valve150mm cast iron wheel operated all as directed by engr-in-charge |
| 281 | Supply and fixing in repair for butterfly valve 80mm cast iron all as directed by engr-in-charge |
| 282 | Complete cleaning of external surface of sand filter, removal of rust, oil, grease, dirt, and old loose paint, surface operation by manual wire brushing/ emery paper, surface to be made smooth and rust free beafore application of primer coating with blue colour and thickness of primer should be 25- 30 microns, paint should be industrialgrade enamel paint all as specified and directed by engr-in-charge |
| 283 | Material and labour for repair of vertical pressure multigrade media filter 2 Mtr diameter and 2 Mtr Height of multimedia filter by opening filter taking out all old filter media and replacement of all type of media of adequate quantity not less than 6.5cum as per manufacturer recommendation and refilling, reconnecting of system each necessary welding/ refixing of filter cover and tightening, trial run and testing of filtration system upto satisfaction of engr in charge |
| 284 | Material and labour for repair of vertical pressure activated carbon filter 2 Mtr diameter and 2 Mtr Height of activated carbon filter by opening filter taking out all old filter media and replacement of all type of media with activated carbon granules of adequate quantity not less than 6.5cum as per manufacturer recommendation and refilling, reconnecting of system each necessary welding/ refixing of filter cover and tightening, trial run and testing of filtration system upto satisfaction of engr in charge |
| 285 | Design, Fabrication and installation of MS ach structure using MS channel/ pipe including bending, cutting and welding complete, supply and fixing of MS sheet / ACP sheet cladding on arch including and fixing of lettering with surface preparation and painting with one coat red oxide primer and two coats of synthetic enamel paint, supply and installation of LED lit board with written in area as per actual size required \\"Sewage Tratment Plant Capacity 1.2 MLD, AGE E/M Gandhinagar, GE(A) Gandhinagar\\" and back side of board with \\"Thank You\\" with electricalwiring with pvc conduit, switches and connection toexistiong power supply, transportation, erection and installation of arch at sit all as specified and directed by engr in charge.Note: Fixing of semicircular LED lighting board should be as per STP Gate dia and height of the top most part of the board approximate 5Mtr above the ground |
| 286 | Design, Fabrication and installation of LED lit board made from acrylic sheet with letter of size not less than 100mm size and board size not less than 4 ft x 3 ft, both side visible with LED lightning complete in all respect for SPH-I, SPH-II, SPH-III and Teritary treated water sump/ Pump all as specified and directed by engr in charge.Note: Fixing of LED lightning Lit board should be done with SS poles of dia not less than50mm and PCC grouting in ground below 0.8M and LED Lightning Lit should to be fixed not less than 1.5 m bove the ground Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail