| 1 | Structural steel work riveted, bolted or welded in built upsections, trusses and framed work, including cutting, hoisting, fixingin position and applying a priming coat of approved steel primer allcomplete: |
| 2 | Steel work in built up M.S. tubular section (round, square orrectangular Hollow tube etc.) trusses/frame work etc./ railing work etc.including cutting, hoisting fixing in position and applying a priming coatof approved steel primer, welded and bolted including special shapedwashers etc. complete Hot finished welded type tubes. |
| 3 | Earth work in excavation for foundation, trenches forpipes / cables or drains etc. by mechanical means /manual means (exceeding 30cm in depth.) includingramming of bottom, dressing of sides, disposal of excavatedearth including of all lift and lead upto 50m. Disposed earthto be levelled and neatly dressed. All kinds of soil |
| 4 | Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering All work up to plinthlevel. Cement concrete grade M-10 (Nominal Mix) with 20 mm maximumsize of stone aggregate |
| 5 | Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering All work up to plinthlevel. Cement concrete grade M-20 (Nominal Mix) with 20 mm maximumsize of stone aggregate |
| 6 | Supplying and filling in plinth under floors including,watering, ramming consolidating and dressing complete. Moorum/Hard copra |
| 7 | Supplying and filling in plinth under floors including,watering, ramming consolidating and dressing complete.Crusher Stone Dust |
| 8 | Providing and laying in position specified grade of reinforcedcement concrete excluding the cost of centering, shuttering,finishing and reinforcement - All work up to plinth level : Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum sizeof stone aggregate. |
| 9 | Centering and shuttering including strutting, propping stretching etc.complete for and removal of form work by sheet plate or ply woodshuttering for : Foundations, footings, bases of columns, etc. For mass concrete. |
| 10 | Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding upto floor level including costof binding wire, wastage and over laps upto 12mm horizontal/ inclinedposition of reinforcement bars in slab and beams, plinth, chajjas,lintels, upto 4.5m vertical length of reinforcement in wall columns (overlaps shall be provided as per requirement of IS : 13920; IS 456 & SP :34) etc. complete Thermo-Mechanically Treated bars. (Fe 500 D or more) |
| 11 | 40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 ( 1cement : 5 coarse sand) with joints finished flush. (minimum size of kota stone 0.25 sqm) Red sand stone |
| 12 | Wallpaintingwithplasticemulsionpaintofapprovedbrandandmanufacture to give an even shade: Two or more coats on new work |
| 13 | Distemperingwith1stqualityacrylicdistemper(readymixed)ofapprovedmanufacturer,ofrequiredshadeandcolourcomplete,aspermanufacturer's specification. Two or more coats on new work. Please Enable Macros to View BoQ information |