| 1 | Mechanical transportation, loading, unloading and handling of various items such as pump parts, motors, starters, voltage stabilizers, coil assemblies, welding tools & plant, etc. using appropriate means of transport as under:Private car, auto-rickshaw or similar with 1.0 km lead |
| 2 | Extra per kilometer for lead >1.0 kms upto 5.0 kms |
| 3 | Extra per kilometer for lead >5.0 kms upto 10.0 kms |
| 4 | Extra per kilometer for lead >10.0 kms upto 20.0 kms |
| 5 | Extra per kilometer for lead >20.0 kms upto 30.0 kms |
| 6 | Load carrier auto, mini van or similar with 1.0 km lead |
| 7 | Extra per kilometer for lead >1.0 kms upto 5.0 kms |
| 8 | Extra per kilometer for lead >5.0 kms upto 10.0 kms |
| 9 | Extra per kilometer for lead >10.0 kms upto 20.0 kms |
| 10 | Extra per kilometer for lead >20.0 kms upto 30.0 kms |
| 11 | Mini truck like Tata mobile, Bolero Camper or similar with 1.0 km lead |
| 12 | Extra per kilometer for lead >1.0 kms upto 5.0 kms |
| 13 | Extra per kilometer for lead >5.0 kms upto 10.0 kms |
| 14 | Extra per kilometer for lead >10.0 kms upto 20.0 kms |
| 15 | Extra per kilometer for lead >20.0 kms upto 30.0 kms |
| 16 | Truck, tipper or similar with 1.0 km lead |
| 17 | Extra per kilometer for lead >1.0 kms upto 5.0 kms |
| 18 | Extra per kilometer for lead >5.0 kms upto 10.0 kms |
| 19 | Extra per kilometer for lead >10.0 kms upto 20.0 kms |
| 20 | Extra per kilometer for lead >20.0 kms upto 30.0 kms |
| 21 | Head load carriage of machinery/ equipment at locations inaccessible by vehicles on plain/ rough terrain Upto 50 kgs load |
| 22 | Extra for every additional 50kgs load (Note: Fraction >=25kgs shall be taken as equivalent to next load of 50kgs) |
| 23 | Extra for uphill terrain (Ground Slope >= 07 deg) |
| 24 | TRANSFORMERDismantling of 33/0.4 kv or 11/0.4kV transformer by way of disconnecting of all HT and LT connections, opening of top lid, draining out of T. Oil and its safe placement for further refilling, taking out of coils after removal of core assembly, etc. Job also includes detaching of core HV/LV coils. upto 50 kVA |
| 25 | >50 upto 100kVA |
| 26 | >100kVA upto 250 kVA |
| 27 | greater than 250 kVA upto 630kVA |
| 28 | Complete assembling of 33/0.4 kv or 11/0.4kV transformer after cleaning of tank, fitting of coil assembly in the tank. Job further includes closing of the transformer lid by way of fitting of existing nuts/bolts and gaskets, insulators, etc. Refilling of t.oil upto required level in tank. Reconnecting of HT/ LT connections and testing.upto 50 kVA |
| 29 | >50 upto 100kVA |
| 30 | >100kVA upto 250 kVA |
| 31 | greater than 250 kVA upto 630kVA |
| 32 | INSULATORSSupplying and erection of galvanised ‘D’ iron clamps complete with shackle insulator (75 mm X 90 mm), G.I bolts, nuts and washers, coach screws etc. as required for LT lines. |
| 33 | Supplying and erection of 100 mm X 80 mm pin insulator complete with G. I. Spindle and nuts etc. as required for LT lines. |
| 34 | Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required. |
| 35 | Supplying and erection of 33 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required. |
| 36 | Providing and fixing of 12 KV Pin insulator with Pin |
| 37 | Supplying and erection of 11 KV disc insulator with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required. |
| 38 | Supplying and erection of a set of three 11 KV disc insulator for 33 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required. |
| 39 | LIGHTNING ARRESTORSupplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required. |
| 40 | Supplying and erection of single piece nonlinear resistor type lightning arrestor suitable for 3 wire, 33 KV overhead lines with rated voltage 30 KV (rms) with a nominal discharge current rating of 10 KA (station class) and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required. |
| 41 | Providing and fixing of lightning conductor finial, made of 25mm dia 300 mm long, G.I. tube, having single prong at top, with 85mm dia 6 mm thick G.I. base plate including holes etc.complete as required. |
| 42 | FUSESSupply and erection of 200A horn gap fuse set with post insulators suitable for 3 wire, 11 KV overhead lines. |
| 43 | Supply and erection of horn gap fuse set with post insulators suitable for 3 wire, 33 KV overhead lines. |
| 44 | Supply and erection of drop out fuse set suitable for 3 wire, 11 KV overhead lines. |
| 45 | Supply and erection of drop out fuse set suitable for 3 wire, 33 KV overhead lines. |
| 46 | Providing of 11Kv DO Operating Rod (FRP) with min. 18 ft length |
| 47 | Providing of 33Kv DO Operating Rod (FRP) with min. 18 ft length |
| 48 | Providing and fitting of fuse element of required current rating for DO Fuse. |
| 49 | Providing of requisite tinned copper fuse wire |
| 50 | Providing & fixing of HD link set – 200 Amp for 11 KV power supply. |
| 51 | SWITCHESProviding and fitting of 11 KV 200A 3-ph Gang operated Air Break Switch complete with operating mechanism |
| 52 | Providing and fitting of 33 KV 400A 3-ph Gang operated Air Break Switch |
| 53 | Providing and fitting of following Air Break switch accessoriesProviding and fixing of Air Break Switch Handle |
| 54 | Providing and fixing of 'DANGER' plate of standard size for 440V/ 11KV/ 33KV. |
| 55 | EARTHINGEarthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and 20mm GI (medium class) watering pipe 2.7 meter long, funnel etc. with charcoal/ coke and salt as required. |
| 56 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 57 | Supplying and laying 25mm X 5mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. |
| 58 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 59 | Providing and fixing 25 mm X 5 mm G.I strip on surface or in recess with GI saddles and allied fittings for connections etc. as required. |
| 60 | TRANSFORMERProviding new CRGO lamination to the core in place of damaged core wherever necessary including cost of materials and labour |
| 61 | Providing and fitting of finished new electrolytic grade copper wire windings with insulation in place of damaged windings including allied such as varnish and labour, drying, etc., (Both HV & LV) - per kg of winding. |
| 62 | Providing and fitting of finished new electrolytic grade copper strip windings with insulation in place of damaged windings including allied costs such as varnish and labour, drying, etc., (Both HV & LV) - per kg of winding. |
| 63 | Providing and fitting of finished new aluminium wire windings with insulation in place of damaged windings including labour costs, etc., (HV/ LV) - per kg of winding. |
| 64 | Providing and fitting of finished new aluminium strip windings with insulation in place of damaged windings including labour costs, etc., (HV / LV) - per kg of winding. |
| 65 | Rewinding with re-insulation of existing copper conductors (HV) by way of providing and replacement of inter-layer insulation - per kg of winding. |
| 66 | Rewinding with re-insulation, ducting of existing copper conductors (LV) by way of providing and replacement of inter-layer insulation - per kg of winding. |
| 67 | Rewinding with re-insulation of existing aluminium conductors (HV) by way of providing and replacement of inter-layer insulation - per kg of winding. |
| 68 | Rewinding with re-insulation of existing aluminium conductors (LV) by way of providing and replacement of inter-layer insulation - per kg of winding. |
| 69 | Providing and fitting of Hot dipped galvanised MS nuts, bolts and washers of assorted sizes |
| 70 | Supply of Neoprene Rubberized Gasket Sheet3mm thick |
| 71 | 5mm thick |
| 72 | 6mm thick |
| 73 | Providing and fitting of LV (1.1 KV) porcelain bushings of rating:250 A |
| 74 | 630 A |
| 75 | 1000 A |
| 76 | 2000 A |
| 77 | 3150 A |
| 78 | Providing and fitting of HV porcelain bushings of rating:250 A, 17.5KV |
| 79 | 630 A, 17.5KV |
| 80 | 1000 A, 17.5KV |
| 81 | 2000 A, 17.5KV |
| 82 | 250 A, 36KV |
| 83 | 630 A, 36KV |
| 84 | 1000 A, 36KV |
| 85 | 3150 A, 36KV |
| 86 | Providing and fitting of metal part stem with allied fittings of transformer bushings (HV/ LV) as under:Brass |
| 87 | Aluminium |
| 88 | Copper |
| 89 | 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 90 | 11kV Polymeric Composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 91 | Earthing of substation including H.T Transformer comprising of excavation of earth pit of Dia 650mm and depth 3000mm, installation of Earthing pipe of 40mm Nominal bore and requisite thickness and length of 2.5 Mtr as per IS 1239. GI strip for neutral earthing of size 25x3mm for connection of transformer body, Link set and Dropout set etc. |
| 92 | Labour for branch cutting of trees (1 Day @ 2 Persons) |
| 93 | Installation of 2 No. Departmental poles .The job includes Cement Bottoming of Poles in 1:2:4 mix as per REC Standards @ 0.5 Cum per pole. |
| 94 | Galvanized iron Channel /Angle/ Flat of various sizes including clamps for taping of 11kva line. |
| 95 | Earthing of H.T Poles Comprising of Installation of Earthing GI rod of 15 mm (approx.) and length of 2.5 Mtr and GI strip for earthing of size 25x3mm for connection of pole with earthing rod and fittings. |
| 96 | Supply and erection of Steel Tubular Poles duly painted with two coats of silver colour paint over a coat of red oxide.The job includes all carriages, leads and lifts, trench cutting ( depth = 1/6 of pole height), backfilling of trenches540 SP 28 |
| 97 | 410 SP 29 |
| 98 | 410 SP 30 |
| 99 | 410 SP 31 |
| 100 | 410 SP 32 |
| 101 | 410 SP 33 |
| 102 | .Providing and laying of ACSR conductor on poles 03 ACSR |
| 103 | .05 ACSR |
| 104 | Providing of T. oil conforming to IS 335 preffered make (Power oil, Indian Oil, Servo, HPCL) |
| 105 | Filterationof existing/ reclaimed T.oil on site at suitable temperature( Inclusive of all logistic and charges for filteration plant etc) (process loss maximum 5% allowed) |
| 106 | Structural steel for provding and installation of MS crosses, braces, channels of various size for HT/LT works |
| 107 | Complete winding of stator coils of 3-phase LV horizontal/ vertical induction motor/ submersible motor/ autotransformer/ voltage stabilizer/ etc. and the like with suitable copper wire (excluding carriage and dismantling/ reassembling charges).(Note: The unserviceable scrap copper generated is not taken into account for estimation of rates and shall be accounted separately).Providing and fitting of finished new electrolytic grade copper wire windings with insulation in place of damaged windings including allied jobs such as varnishing (Becks or any other reputed make) drying, etc., (Both HV & LV) - per kg of winding. |
| 108 | Providing and fitting of finished new electrolytic grade copper strip windings with insulation in place of damaged windings including allied costs such as varnish (Becks or any other reputed make), drying, etc., (Both HV & LV) - per kg of winding. Please Enable Macros to View BoQ information |