| 1 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: |
| 2 | G.S. Sheet |
| 3 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required with |
| 4 | Precoated galvanised iron profile sheets 0.50 mm thick |
| 5 | Providing and fixing precoated galvanised steel sheet roofing accessories , Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete : |
| 6 | Ridges plain (500 - 600mm). |
| 7 | Precoated galvanised iron profile sheets 0.50 mm thick |
| 8 | Extra for providing 3 mm thick translucent white acrylic plastic sheets of approved quality in false ceiling instead of 12 mm thick plain/or with design particle board ceiling tiles in item above. |
| 9 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked M.S butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. |
| 10 | Local best quality Tolhao wood. |
| 11 | 35 mm thick shutters |
| 12 | Providing wood work in frames of false ceiling, partitions etc. sawn and put up in position : |
| 13 | Local best quality Tolhao wood. |
| 14 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade |
| 15 | New work (two or more coats) over and including priming coat with cement primer:- |
| 16 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: |
| 17 | Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 18 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. |
| 19 | With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 20 | Demolishing lime concrete manually/ by mechanical means and disposal of material within 50 metres lead as per direction of Engineer in charge. |
| 21 | Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 22 | Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 23 | 40mm thick with 20mm nominal size stone aggregate. |
| 24 | Providing and fixing aluminium work for doors, windows, ventilators and partitionswith extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required EPDM rubber/ Neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleatangle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steelscrews, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and panelling to be paid for separately): |
| 25 | For fixed portion. |
| 26 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 27 | 66mm overall thickness Partition with 8mm thick double skin Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process with Compressive Strength 225 kg/sq.cm, Bending Strength 100 kg/ sqcm. |
| 28 | Providing and refixing precoated galvanised sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required with |
| 29 | Precoated galvanised iron profile sheets 0.50 mm thick Please Enable Macros to View BoQ information |