| 1 | Excavation in foundation in ordinary soil (loam,clay or sand) icluding lift up to 1.50 m. and lead up to 30m. and including filling watering and ramming of excavated earth into the trenches or into the space of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the engineer-in-charge upto a distance of 30m. from the foundation trenches ( where machine con not rech/move).SOR-251a |
| 2 | Extra rates for quantities of works, executed: In or under water and/or liquid mud, including pumping out water as required. (DSR-2018/2.24.1/A.R.) |
| 3 | Extra for every additional lift 1.5m or part there of all kinds of soil. (AR/GNIDA) |
| 4 | 1.5 mtr to 3.00 mtr. |
| 5 | CARTAGE OF Earth of fly ash when added to schedule item no. 253 |
| 6 | Lead upto 2 KM. (SOR-261C) |
| 7 | Surface dressing of the ground including removing vegetation and in equalities not exceeding 15cm deep and disposal of rubbish, lead upto 50m and lift upto 1.5m (All kind of soil) DSR-18/2.28.1 |
| 8 | Cleaning jungle including up rooting of rank, vegetations grass, push, wood trees and samplings of grith upto 30 cms.measured at a height of 1 M. above ground level and removal of rubbish up to a distance of 50M. out side the removal of rubbish upto area cleared. SOR/259(i) Same as above but grass only SOR-20/259(a)/4.06 |
| 9 | Tractor with trolley including POL and driver SOR-20/SI.NO.19/Chapter-2 |
| 10 | Supply of labour SOR-20/SI.NO.12/Chapter-2 |
| 11 | Supply of water tanker (5000 Litre capacity) with driver and including POL (AR/GNIDA) |
| 12 | Providing JCB with driver and including POL (AR/GNIDA) (SOR-20/S/NO. 31/Chapter 2) |
| 13 | M-150 Brick Work 1:6 one cement & four Coarse sand of 2.20 F.M. mortar in foundation and plinth including supply of all materials, labour and T&P etc. requried for proper completion of the work. SOR-2020, item-305(a) |
| 14 | 12 mm cement plaster of mix |
| 15 | 1:6 (1 cement: 6 coarse sand) DSR-18/13.4.2 |
| 16 | Excavating holes more than 0.1 cum & up to 0.5 cum including getting out the excavated soil, then returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering etc, disposing of surplus excavated soil; as directed within a lead of 50 m and lift up to 1.5 m. All kind of soil (DSR-18/2.30.1) |
| 17 | Providing and fixing R.C.C direction board size 200x510x80mm make in one 1:1.5:3 including reinforcement and shuttering etc. all complete direction of Engineer-in-Charge |
| 18 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: |
| 19 | 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size). |
| 20 | Painting or varnishing work in small areas or new wood work with one coat (upto one square metre of ready mixed priming paint and one coat of approved superior quality ready mixed paint or varnish including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. Paint to be used should confirm the ISI no. 103-1950. SOR-20/641 |
| 21 | painting letters up to 2.5 cm. size including supply of all materials, labours & tools and plants etc. required for proper completion of the work. As in item 820 above but size above 8cm. but up to 15cm.SOR-20/822/21.07 |
| 22 | Repainting letters up to 2.5 cm. size including supply of all materials, labours & tools and plants etc. required for proper completion of the work. Repainting border line upto 2.5 cm. to 5 cm. wide SOR-20/837b/21.14 |
| 23 | Finishing wall with water proof cement paint of approved make and quality on new wood with two coat to give an even shade including supply of all materials, labour, Tools & plant etc. required for proper completion of the work.Same as item 660 but for weather coat.(Asian or Berger Brand) SOR-20/New Item |
| 24 | Painting or varnishing with valsper or other approved high grade enamel or super par synthetic clean varnish complete one coat over previously painted surface including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. Paint to be used should confirm ISI no. 105/106/133-1950.As in item (647) above but for every subsequent coat on previously treated surface SOR-20/647+648 |
| 25 | Providing and fixing SFRC cover on chamber (without frame) 50mm thick size 600x600mm (AR/GNIDA) |
| 26 | Size 600x600mm (Heavy duty) |
| 27 | Providing and fixing SFRC cover on chamber (with frame) 50mm thick.(AR/GNIDA) |
| 28 | Size: 600x600mm (Heavy duty) |
| 29 | Providing and tieing fectory made precast RCC perforced drain coues having concrete of stregth not less than m-25 of size 1000x450x50mm reinforced with 8mm dia four nos long to dia all and I nos cross seasenal T.MT hoop bars, including providing 50mm dia perforations @ 100 to 125mm etc, including providing edge binding with m.s flates of size 50mm x1.6mm complete, all as per dircetion of engineers in charge. DAR-2018/19.19.3.1 |
| 30 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 31 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. (Sail Steel) (DSR-2018/10.25.2/AR) |
| 32 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing and staircase railing including applying a priming coat of approved steel primer. |
| 33 | G.I. pipes. DSR-18/10.26.2 |
| 34 | Fencing with R.C.C. post placed at required distance, embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall b sttutted on both sides and end post one side only, provided with horizontal lines and two diagonals of barbed wire 9.38 kg per 100 metres (mm) between the two posts fitted and fixed with G.l. staples on wooden plugs or G.l. binding wire tied to 6 mm bar nibs fixed while casting the post (cost of R.C.C. posts, struts, earth work and concrete to be paid for separately) :- Payment to be made per metre cost of total length of barbed wire used. |
| 35 | With G.l. barbed wire DSR-18/16.17.1 |
| 36 | Washed stone grit plaster on exterior walls height upto 10 mtr above ground level, in two layers, under layer 12mm cement plaster 1:4 (1 cement : 4 coarse sand), furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 2kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size), in pannels with groove all around as per approved pattern, including scrubbing and washing the top layer with brushes and water to expose the stone chippings, complete as per specification and direction of Engineer-in-charge (payment for providing shall be made separately).DSR-18/13.72 |
| 37 | Hiring of portable Re-cycle jetting calus section machinenmounted on mahindra volero maxi with hydraqulically operate mahindra de-silter upto depth of 15 water with driver for the area to gr.noida as direated by engineer in-chare for 8.50 hours per day overfine will be paid on pro rate basic processure 3000 PSI liters, rate as per (GNIDA) |
| 38 | Excavation in foundation in ordinary soil (loam,clay or sand) icluding lift up to 1.50 m. and lead up to 30m. and including filling watering and ramming of excavated earth into the trenches or into the space of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the engineer-in-charge upto a distance of 30m. from the foundation trenches ( where machine con not rech/move).SOR-251a |
| 39 | Providing and laying in position cement concrete 1:4:8 (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) in concrete cradle under NP-2 pipe of folling diameter including centring shuttring but excluding excavation: |
| 40 | 300mm NP-2 dia. RCC Pipes |
| 41 | 350mm NP-2 dia RCC Pipes |
| 42 | 400mm NP-2 dia RCC Pipes |
| 43 | 450mm NP-2 dia RCC Pipes |
| 44 | 500mm NP-2 dia RCC Pipes |
| 45 | 600mm NP-2 dia RCC Pipes |
| 46 | Supply of ISI marked RCC NP-2 pipes of following size including catting loading unloading at godown including all taxes and levies and rubber rings. |
| 47 | 300mm NP-2 dia. RCC Pipes |
| 48 | 350mm NP-2 dia RCC Pipes |
| 49 | 400mm NP-2 dia RCC Pipes |
| 50 | 450mm NP-2 dia RCC Pipes |
| 51 | 500mm NP-2 dia RCC Pipes |
| 52 | 600mm NP-2 dia RCC Pipes |
| 53 | Laying of NP-2 RCC S&S pipes jointing with stuff mixture of cement mortar in the propertion of 1:2 (1 cement :2 coarse sand) including testing of jointed complete |
| 54 | 300mm NP-2 dia. RCC Pipes |
| 55 | 350mm NP-2 dia RCC Pipes |
| 56 | 400mm NP-2 dia RCC Pipes |
| 57 | 450mm NP-2 dia RCC Pipes |
| 58 | 500mm NP-2 dia RCC Pipes |
| 59 | 600mm NP-2 dia RCC Pipes |
| 60 | Supply of dewatering pump 10 H.P (MORTH/P.NO.746/S.NO 109) |
| 61 | Painting with aluminium paint of approved brand and manufacture to give an even shade: One or more coats on old work. (DSR-2018/13.100.1/AR) |
| 62 | Labour Cess and GST will be paid extra as per govt.orders Please Enable Macros to View BoQ information |