| 1 | Excavation in trenches not exc 1.5m wide and n exc 1.5m in depth, for foundation, etc or for shaft , wells, cesspits, manholes, pier holes, etc n. exc 10 Sqm on plan and not exc 1.5m in depth and getting out in soft/ loose soil complete all as specified and directed. |
| 2 | ,---ditto--- all as per item No. 1 above but depth exc 1.5m but not exc 3m complete all as specified and directed. |
| 3 | ,---ditto--- all as per item No. 1 above but depth exc 3m but not exc 4.5m complete all as specified and directed. |
| 4 | ,---ditto--- all as per item No. 1 above but depth exc 4.5m but not exc 6m complete all as specified and directed. |
| 5 | Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm in soft/ loose soil complete all as specified and directed. |
| 6 | Removing excavated material n.exc 50m & depositing where directed at a level n.exc 1.50m above the starting point in soil complete all as specified and directed. |
| 7 | Demolition and breaking up 150mm dia drain pipes (Salt glazed ware, AC or reinforced concrete) alongwith fittings and accessories jointed in cement mortar and taking out from walls, floors or from trenches, if required complete all as specified and directed. Note : The length shall be measured along the centre line including fittings and accessories). |
| 8 | ,---ditto--- all as per item No. 7 above but 200mm dia complete all as specified and directed. |
| 9 | Supply & laying DWC pipe (Double wall corrugated ) of class SN-4, IS-16098 (Part –II) of size internal dia of 150 mm, laid in trenches and jointed complete with coupler, bend, Tee, reducer etc complete all as specified & directed .Note : Earth work shall be measured and paid seperately |
| 10 | ,---ditto--- all as per item No. 9 above but 200mm dia complete all as specified and directed. |
| 11 | Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and directed. |
| 12 | M & L Brick work with sub class ‘B’ bricks (using old size bricks) straight or curved on plan exc 6 mtr mean radius built in CM 1:6 including raising height of man holes from ground level complete all as specified and directed |
| 13 | M&L rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces, finished even and fair using water proofing compound complete all as specified and directed.Note : Waterproofing compound paid separately |
| 14 | M&L providing cement concrete type B-0 1:2:4 (using 12.5mm graded aggregate) in lintels up to 1.5m clear span, cills, bed plates,coping, kerbs water trough & the like including weathering, slightly rounded or chamfered angles & throating complete all as specified and directed by Engr-In-Charge |
| 15 | M&L PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed. |
| 16 | M&L PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in surface channels and drains and benching including finishing the top of benching even and smooth with using extra cement complete all as specified and directed. |
| 17 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stopped ends etc (inner girth only to be measured) complete all as specified and directed. |
| 18 | S& F RCC Ferro cover 75 mm thick of M-25 Grade and size 800mm x600 mm with mild steel plate frame of min 1.25mm thick, chequered finish on top with min 02 No. Hooks to place cover complete all as specified and directed by Engineer -in - charge. |
| 19 | S& F RCC Ferro cover 75 mm thick of M-25 Grade and size 450mm x 450 mm with mild steel plate frame of min 1.25mm thick, chequered finish on top with min 02 No. Hooks to place cover complete all as specified and directed by Engineer -in - charge. Please Enable Macros to View BoQ information |
| 20 | S& F RCC Ferro cover 75 mm thick of M-25 Grade and size 450mm x 450 mm with mild steel plate frame of min 1.25mm thick, chequered finish on top with min 02 No. Hooks to place cover complete all as specified and directed by Engineer -in - charge. Please Enable Macros to View BoQ information |