| 1 | Excavation in drains and channels etc. in earth work lift up to 1.5 meter stacking the excavated soil not more than 3 meters clear from the edge of excavation and then returning the stacked soil in 15 cm layer in trenches consolidatig each deposited layers by ramming and watering and then disposing of all surlus excavated earth as directed with in a lead of 20 meter in pick jumper work. |
| 2 | Providing Laying jointing,testing and commissioning at site in treches galvanised miled steel pipe 150 mm dia (medium grade) as under confirming to BIS-1239 (part 1) 1990 or latest with upto date amendments capable of with standing required test pressure as prescribed in BIS/ISO code, in random lengths of 5.50 to 5.60 meter. The pipe ends shall be bevelled suitable for butt welding, confirming to IS -816-1969 or latest as applicable (leak proof) in three layers at site of work with welding rods of standard make and all allied accessories what evere required for welding at site, tail pieces, tees, bends and other special manufactured from parent pipes etc. and cutting of pipes whatever required as per site requirment i/c carriage in all leads and lifts and as per directed by Engineer in Charge (earth work in trench to be measured and paid for separatly). |
| 3 | 80 mm dia |
| 4 | Providing and fixing MS plate flanges following dia conforming to ISI sapecification no- 6392-1971 table-5 & 17 to be fixed with GMS pipes as per item above including cost of welding, nuts and bolt, fire fly champion make gasket 3mm thick complete in all respect of following dia. |
| 5 | 80 mm dia (Table-17) |
| 6 | 80 mm dia (Table -5 ) |
| 7 | 15mm thick cement plaster in single coat with cement mortar1:5 (1 cement :5 sand)of rough side or brick masonary/ stone masonary /concrete / walls for interior plastering upto floor two level i/c arrises, internal, rounded angles, chambers and/or rounded angles not exceeding 80 mm in girth and finished even and smooth in cement mortar1:5 (1 cement :5 sand). |
| 8 | Finishing wall with water proofing cement paint of approved brand and manufacture and of requir shade on undecorated wall surfaces (two coats) to give an even shade after thoroughly brushing the surface to remove all dirt and remains of loose powered materials. |
| 9 | Providing and fixing of man hole cover,water guage and other accessories complete in all respect. |
| 10 | Providing chemical protection to the over head tank |
| 11 | Excavation in foundation & trenches etc. in in earth work lift up to 1.5 meter stacking the excavated soil not more than 3 meters clear from the edge of excavaton and then returning the stacked soil in 15cm layers when required into plinths, side of foundation etc. Consolidating each deposited layers by remming and watering and then disposing of all surplus excavated earth as direction within a lead of 20 mtr in pick work. |
| 12 | Providing and lying cement concrete 1:6:12 (1Cement: 6Sand: 12 approved quarry stone agg.40mm nominal size)& curing complete excluding cost of form work in Foundation and Plinth, i/c entire carriage of materials up to all leads and lifts |
| 13 | Ist class Brick work using common burnt clay building bricks in foundation and plinth in cement mortar 1:6 (1 cement :6 sand) complete in all respect i/c entire carriage of materials up to all leads and lifts |
| 14 | Ist class Brick work using common burnt clay building bricks in super structure in all heights and depth in cement mortar 1:6 (1 cement :6 sand) complete in all respect i/c entire carriage of materials up to all leads and lifts |
| 15 | Providing from work with steel plates 3.15 mm thic welded with angle iron in frame 30x30x5 mm so as to give a fair finish i/c centring, shuttering, strutting and proping etc with wooden battens and ballies. Height of proping and centring below suporting floor to ceiling not exceeding 4 mtrs and removal of the same for insitu -reinforced concrete and plain concrete work in flat surfaces such as soffits of suspended floors, roofs, landing and the like floor etc. up to 200 mm in thickness i/c carriage of material within all leads and lifts complete in all respect. |
| 16 | Providing and laying Cement concrete work 1:2:4 (1 cement :2 sand :4 water borne aggregate 20mm nominal size) and curing complete excluding the cost of form work and reinforcement for reinforced concrete work in suspended floors, roofs, landing shelve and their supports balconies beams, girders bressumers and centilevers upto floor two level. |
| 17 | Providing and placing Tor Steel reinforcement for RCC work including bending , binding and placing in position complete upto floor two level. |
| 18 | P/ F pressed steel door frames manufactured from commercial MS sheets of 1.25mm thickness including hinges, jump lock jamp. Bead and if required angle threshold of MS angle 50 x 25 mm or base tie of 1.25mm pressed MS welded or rigidly fixed together by mechanical means, adjustable lugs with split and tails to each jamp i/c steel butt hinges 2.5mm thick with guards, lock strike plate and shock as specified and applying a coat of steel primer after pretreatment or surface as directed by Engineer-in-charge. |
| 19 | Profile- \\"A\\" |
| 20 | Profile- \\"B\\" |
| 21 | Providing and fixing 1mm thick M.S sheet door with frame of 40mmx40mmx6mm angle iron 3 15mm MS gusse plate at the junctions and corners including all necessary fittings, complete including applying a priming coat of rep lead paint using flat 30mm x6mm for diagonal braces and control cross/pieces with in all leads and lifts |
| 22 | Filling in plinth with sand under floors including ramming consolidating and dressing cmplete. |
| 23 | Cement concrete flooring 1:2:4( 1 cement : 2 quarry sand :4 app. quality stone aggregate 20 mm nominal size laid in one layer finished with a floating coat of neat cement 40 mm thick complete in all respect i/c entire carriage of materials up to all leads and lifts |
| 24 | Providing and fixing on wall face PVC rain water pipe i/c fitting and comletein all respect. |
| 25 | Applying Birla white wall care putty over plaster surface after thoroughly brushing the surface free from mortar drops, dust, loose materials and other foreign matters sand papered smooth to give final matt finish to the surface complete. |
| 26 | Distempring (two coats) with oil bound washable distamper of approved brand and manufacture and of required shade on undercoated wall surface to given an even shade over and i/c primer coatwith distamper primer of approved brand and manufacture after thoroughly brushing the surface free from mortar dropings and other foreign matter i/c papering the surface even and sand paperd smooth. priming coat with distemper primer details of cost for 10 sqm. |
| 27 | Finishing wall with water proofing cement paint of approved brand and manufacture and of requir shade on undecorated wall surfaces (two coats) to give an even shade after thoroughly brushing the surface to remove all dirt and remains of loose powered materials. |
| 28 | Providing plinth protection50 mm thick in cement concrete 1:3:6 (1Cement: 3Sand: 6 Graded stone agg.20mm nominal size)& curing complete i/c entire carriage of materials up to all leads and lifts. |
| 29 | Painting two coats (excluding priming coat) on new steel and other metal surfaces with ready mixed paint brushing to give an even shade including cleaning the surface of dirt ,dust and other foreign matter with ready mixed paint other than white complete in all respect as per the direction of the Engineer - in - Charge. |
| 30 | Providing and fixing M S tower bolts (barrel type) with screws etc complete 250x16mm |
| 31 | Providing and fixing M S fan clamp type-I of 16 mm dia MS bar to shap with hooked ends in RCC during laying including printing the exposed portion of loop, all as per standared design complete. |
| 32 | P/F MS grills of required pattern in wooden frames/pressed steel frame with MS flat square/round bars 12 mm dia with round headed bolts and nuts or by screws or namental grill. |
| 33 | Supply, erection, testing & commissioning of submersible pumping set three phase of reputed make such asKBS/BS Johnston/wortington/ Kirloskar make three phase conforming to latest relevent BIS code. The pump should be fitted with free flow impellers of bronze/ suitable alloy as per BIS 5659 or latest with up to date ammendments suitable for raw /clear water having charctorstics as mentained in itemno. 1(a) greased packed bearings & shell with wound starter on motor side & with shaft protection sleeve on pump side ensuring better life for shaft conforming to BIS specifications. The pump shell be directly coupled to a submersible squirrel cage electric induction motor of kirloskar /Jyoti/ NGEF/ cromption make conforming to relevent BIS code with up to date ammendments totally dust & water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber & grease packed lubricated bearings & provided with stainless steel thrust bearing plate to with stand non vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansoin of water with the heating of motor. The pump should include water level guard, errection clamps, cable clips & depth gauge etc. including pannel board, starter and single phase cable complete in all respect & suitable for operation on data given below :- |
| 34 | Total head in mtrs (i/c depth of column pipe in case of t/ well. 62.77 mtrs |
| 35 | Capacity (in LPS ) of each pump set. 4.50 LPS |
| 36 | Dia of rising main :-80 mm Please Enable Macros to View BoQ information |