| 1 | Earth work in excavation of Foundation and plinth in hard soil including dressing and levelling of bed within initial lead of 50mtr.andlifi 1.5mtr etc complete as per the direction of the Engineer-in-charge. |
| 2 | Filling in foundation and plinth with sand including watering and ramming etc complete as per the direction of the Engineer-incharge. |
| 3 | Cement concrite(1:4:8) with 4cm size h.g.b. crusser broken metal of approved quality from approved quarry with ramming watering and curring etc.complete including cost , taxes, royality convence charges of all materials to work site,supply of cement T&P required etc.comelete as per the direction of the Engineer-incharge. |
| 4 | Cement concrite(1:2:4) with 12mm size black Crusher broken chips of approved quality from approved quarry with ramming watering and curring etc.complete including supply of all labours, cost.taxes,royality convence charges of all materials to work site,supply of cement T&P required etc.comelete as per the direction of the Engineer-incharge. |
| 5 | Brick work with KB Brick 25cm x 12cm x 8cm size having croshing strength not less than 100kg/cm2 to149kg/cm2 with dimensional tolerrance± 8% in cement morter (1:6) in foundation and plinth etc. complete as per the Engineer-incharge. |
| 6 | 12mm thick cement plaster in cement morter(1:6)finished smooth to brick work after racking out joints including watering and curring etc.complete including cost.taxes,royality convence charges of all materials to work site,supply of cement T&P required etc.comelete as per the direction of the Engineer-in-charge. |
| 7 | Rigid smooth centering & shuttering for R.C.C. Works walls & fins including false work & dismateling them after 28 days of curing including cost of all materials complete as per direction of Egineer-In-Charge |
| 8 | R.C.C. work in C.C.(1:2:4) including hoisting, laying & curing for 28 days with 12mm size black Crusher broken chips of approved quality from approved quarry with ramming watering and curring etc.complete including supply of all labours, cost.taxes,royality convence charges of all materials to work site,supply of cement T&P required etc.comelete as per the direction of the Engineer-incharge. |
| 9 | Labour charge for M.S. reinforcement for R.C.C. work including cutting, bending & tying the grills & placing in position including cost of binding wire 18 to 20 gauge including cost of HYSD steel bar etc. complete. |
| 10 | Cement punning over plastering including watering & curing with cost, taxes, royality & conveyance charges of all materials & supply of all materials & T& P etc complte as per direction of Engineer- in - charge. |
| 11 | Filling in foundation and plinth with excavated materials including watering and ramming as directed by the Engineer-incharge. |
| 12 | Wall painting two coats with approved paint over a coat of wall cement primer of approved shade after cleaning the surface with watering, curing, cost, conveyance royalties & taxes of all materials & labour T&P required for the work etc. complete |
| 13 | Writing charge of required information and data on both side of the transperancy pillar including supplying of approved paints and required material for writing etc. complete. |
| 14 | Fitting of un plasticised 160mm dia PVC Pipe for following inside dia mtr. for all classes of pipe including jointing the pipe with solvent cement by non-heat application method including fitting & fixing of required nos. of PVC Teee for outlet & PVC shaddle & PVC raiser, nipple for fitting of air valve, equal Tee etc. complete including conveyance of pipe from factory to work site & testing of pipe line etc complete as per direction of Engineer - in-charge. |
| 15 | Supply of solvent cement of approve quality for joiniting of PVC Pipe with all cost and all tax etc. complete as per direction of Engineer- in-charge. |
| 16 | Labour charges for lowering & Instalation of 7.5HP submersible pump Sets including fitting and fixing of delivery pipe to motor,NR Valve, Sluice valve and other fitting materials including cutting, welding and etc. including transportation to project site and site clearance etc. complete as per the direction of the Engineer-incharge. |
| 17 | Fabrication of special joint including cutting and welding of pipes out of M.S. pipe / 100mm dia G.I.pipe including welding charges etc. complete. |
| 18 | Construction of outlet at Tank |
| 19 | 100mm. Dia nominal bore G.I.pipe having wall thickness 4.5mm.Elecrical resistance welded.Medium class confirming to IS 1239(Pt-1/2004) with socketed at one end the other end protected with plastic thread protector.The socket confirming to IS-1239 ( pt-I/1992) with latest amendmewnts in random length of 4 to7 mtrs. Each pipe should bear ISI Certfication & manufacturers name/Trade mark including all taxes etc. with guarantee. |
| 20 | Cost of 100mm dia G.I. Bend confirming to IS-1239(Pt-II 1992) including all taxes etc. |
| 21 | Cost of 100mm dia G.I. Socket including all taxes etc. |
| 22 | 100mm dia G.I.Flange confirming to IS-6392/1971 including all taxes etc. |
| 23 | Cost of 7.5 HP Submerssible Pumpset 900 LPM at head of 25 mtr including 2.5 mm^2 submerssible flat cable 50 mtr. |
| 24 | Supply of 160mm dia unplasticised riged UPVCpipe ivory in colour having specific gravity of 1.40 to1.46 gms/cc of straight length of 6(six) meter for portable water supplies conforming to IS-4985/2000 of BIS-Amendment-2 read with Table-1 of IS-specification bearingISImarks for working pressure CI-I UPVC pipe to withstand pressure of 2.5kgf/sqcm& the specification and manufacture name should be prominently marked on body of each pipe as per the latest Amendment of IS-4985. It includes the cost of sockets in case of plain ended pipe. PDI test are to be condcuted and should be marked on body of each pipe and report is to be obtained from CIPET, Bhubaneswar necessary approval of authority including transporation to work site in complete shape and handed over to Pani Panchayat Chairman of Secretary. |
| 25 | CI double flanged 100mm Non-Return Valve swing type PN-1.0 as per IS:5312 part-I with by pass arrangement. |
| 26 | CI double flanged 100mm dia Sluice Valve |
| 27 | 50MM DIA Air release valve with saddle &Raiser pipe.The air release valve shall confirm to IS14845 with ISImark including all taxes &royality etc. |
| 28 | 160mmx160mmx160mm dia PVC Equal Tee |
| 29 | 160mm dia PVC End Cap |
| 30 | 160mm dia PVC Coupler |
| 31 | 5/8 ' x12\\" Nut bolt & washer F.T. for foundation |
| 32 | 5/8 ' x3\\" Nut bolt F.T. |
| 33 | 1/2\\" x2 1/2\\" Nut bolt F.T. |
| 34 | ⅛\\" thick Rubber Insertion |
| 35 | Cost of 200x100mm dia TW cap |
| 36 | 160 mm x100mm G.I. / M.S. Reducer |
| 37 | Cost, supplying of 160mmx160mmx110mm dia Weldless G.I.Tee (3.6mm thickness) with bend, closing and opening arrangement of reputed brand including all cost, conveyance, cess etc complete but excluding cost of GST |
| 38 | Cost of 12mm dia PVC Insulated Steel Wire rope |
| 39 | Control Pannel with Automatic Star delta Starter, sheet steel enclosure suitable for operation of squirrel cage induction motor up to 10 HP with 16 Amp ( AC - 3 ) duty contactor at 415 volt + 6% - 15 % , 3 phase, 50 Hz AC supply with over load relay range 6.00 to 9.50 Amp & no volt coil with electronic timer suitable for operation at voltage range of 300 to 440 V. The starter should provide dependable protection against over load & single phasing fitted with Volt Meter,Ameter,MCB etc.complete including indicator lamp. |
| 40 | 63 Amp. Main Switch Triple pole & natural of voltage range 440 volt of re-wirable fuse and shall confirming to IS-4064(PT-I& ) with ISI mark including all taxes etc. |
| 41 | Cost of 100 mm dia MS Clamp |
| 42 | Cost of T.W. safe guard |
| 43 | Base Plate for Pannel |
| 44 | 4 KVR Power shunt capacitor including all taxes and royalities etc. |
| 45 | 3 crorex10mm2 Tarpodar cable XLPE (Cross link polyethylin) confirming to IS-7098(part-II ) including laying below 0.9mtr of the ground and filling the excavated materials including watering and rammin including all taxed etc. |
| 46 | Electrical installation with electrical materials such as PVC tape, Ampere tape, 7/20 PVC copper wire, 3/20 PVC copper wire, GI flexible conduite pipe, No. 6 GI wire, Copper cable socket, GI socket and flange and petty materials required for electrical installation.All materials should be as per IS |
| 47 | Electrical earthing including all materials as per the direction of the Engineer-incharge |
| 48 | Construction of 3 phase 11 KV HT line as per REC standard confirming to IE Rules 1956 with 300 kg 9 M long PSC Pole with 55 Sqmm AAAC Conductor average span length 40mtr with ,11 KV \\"V\\" Cross arm, with required No.of 11 KV T & C Disc. Polymer Insulators in tension point & 11 KV Pin Polymer insulators, Couping & Padding of Poles with all G.I.Channels. Danger Board at each Pole, Anti Climbing Devices, Stay Set at Bending point & double stay at end point with 18 mm G.I.H.T.Stay, concreting of Stay with Anchor plate, guarding at Road crossings etc if required including cost of all materials, labour transportation,inspection & commissioning etc. complete. |
| 49 | Construction and erection of 11 /0.4 KV , 25 KVA Double Pole mounted Substation with 5mtrx3mtrx1.5mtr height mesonary toe wall /G.I. Flat fencing boundary wall with Flat with Polymer insulator ,L.T Dist Box with MCCB , Aluminim bus bar of single bay with kitkat fuse , sand filling and metal spearding with M.S.Grill gate ,all Channel matrials should be G.I , 7 Nos earthing with chamber with 3mtr G.I pipe of 40mm dia with connecting of 25mmx 5mm G.I flat to all earthing including 25KVA BIS Leble-II Star rated Transformer confirming to RE Rules 1956, mounted on 2.44 Mtr. Long structure, supported in 300 kg 9 mtr long PSC pole,transformer hard channel & top channel made of 2.8 M long 100 X 50 X 6 mm G.I.Channel, Transformer belting on 2.80 M long 50mm X 50mm X 5 mm G.I.Angle, (all REC SPN Std.F-3) with all accessories like 3 pole 11 KV HG Fuse(F-5)& A.B.Switches(F-9) both mounted on 2.8 M long 75mm X 40mm X 6 mm G.I.Channel and supported by 1.0 M long 50 X 50 X 5 mm G.I.Angle, with 3 No. 11 KV Lightening Arrestors and Danger board at each Pole, Anti climbing Devices & all other necessary fittings i.e required size Nuts & Bolts, Brackets, Cable, Cable Sockets as per TPCOCL specification etc. including cost of all materials, labour , transportation complete with liasioning for testing inspection & commissioning as per specification of TPCODL etc complete. Please Enable Macros to View BoQ information |