| 1 | Supply & fixing of 9 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 155 mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. (UPPWD-2018-645) |
| 2 | Supply and fixing of heavy duty cadmium plated copper connector with end plate complete in all respect (UPPWD-2018/1128 C) |
| 3 | Four way connector HKM 100 |
| 4 | Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 150 Watt. Confirming to IP 66 Protection complete in all respects (UPPWD-2018/1425) CAT-AA |
| 5 | Supply & Fixing of MS rod for earthing with 2.5 m long, solid, 20 mm dia hot dipped galvanised MS rod buried till the top reaches 1.7 mts. below the GL complete with bolts & nuts & Gl earth wire 7/14. Complete in all respect, as per direction of E-/C. GNIDA SOR-2024/41 |
| 6 | Supply and burying of 40mm dia x 4.5 metres long G.I. Pipe vertically for earthing having 12mm dia. Holes spaced 75mm apart drilled up to 2 metre from the bottom complete with earthing lead of No. 6 to 8SWG GI wire in GI Pipe up to appron (and from appron to switch board the cost of G.I. wire and pipe will be extra) upto switch board, 30cm square C.I. box with hinged cover masonary enclosure, unnel at top, alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all espects as per drawing (UPPWD-2018/701) |
| 7 | Supply and wiring of submains with 2 nos 2.5 sq mm & with 1 no earth wire of 1.5 sq mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in existing PVC conduit complete, including supply of all material, labour and T & P etc. required for proper completion of the work as directed by Engineer in charge. (UPPWD-2018/291) |
| 8 | Supply & laying of Aluminium conductor XLPE insulated, armoured served, sheathed cable 1100 V grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks onsides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the E/I, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc (UPPWD-2018/501) |
| 9 | 3.5CX25 Sqmm |
| 10 | 3.5 X 35 Sqmm |
| 11 | 3.5X50 Sqmm |
| 12 | 3.5X70 Sqmm |
| 13 | Supply and fixing of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connection etc, complete in all respect as per direction of the Engineer-Incharge. (UPPWD-2018/504) |
| 14 | 16 Sqmm |
| 15 | 25 Sqmm |
| 16 | 35 Sqmm |
| 17 | 50 Sqmm |
| 18 | 70 Sqmm |
| 19 | Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respect. (UPPWD-2018/716) |
| 20 | Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB's (Four Pole 36 KA with thermal magnatic release) Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA,P.F.KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB's shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm Cubicle type switch board shall be of cat A & B Only (UPPWD-2018/811) |
| 21 | Incoming-200 Amp. MCCB-1 No |
| 22 | Outgoing-100 Amp. MCCB-2 Nos. |
| 23 | Cat B. Pannel Cubicle Type |
| 24 | Supply, Installation, Testing and Commissioning of outdoor type IP-65 cluster control 63A Centralized and control monitoring system (CCMS) consisting of control panel with suitable memory/CPU, inbuilt battery to support operation upto 12 hours, suitable power supply Energy meter with IS 13779 and suitable for GSM/GPRS network complete in all respects as per specifications. This unit shall include timer also and shall function as a composite Unit for the LED luminaires FTS No-133716 Approved date: 22.11.2022 |
| 25 | S/L of 90mm dia. DWC pipe for drawing of power cable across the road by drilling of 120mm dia at 1mtr below the road level thereby doing the work of providing DWC pipe by Trenchless method. Pre Approved F.T.S.-132298 |
| 26 | Supply, delivery, testing, laying of Al, conductor HDPE/XLPE insulated 1100V grade Arial Bunched Cable with Messenger wire as below on pole complete in all respect. (CCI, Gloster, Asian, Universal, NICCO, ICL, Diamond, Havells, Kalinga, Suraj, Delton Grandley & Polycab, make) Complete in all respect, as per the direction of E-/c. GNIDA-SOR-2024/65 |
| 27 | 2Cx 25 Sqmm. + 1C X 25 Sqmm |
| 28 | Supply and Fixing 40mm. dia 1.5mtr. Long G.I. pipe 'B' Class bracket with 2 Nos. 'D' clamps 50X6mm. flat iron on steel tubular pole/ PCC pole with bolts, complete in all respect, as per direction of E-VC. GNIDA-SOR-2024/38 |
| 29 | Supply and Fixing 50 Sgm to 16Sqm LT ABC Connector on Pole complete in all respect, as per direction of E-/C. GNIDA-SOR-2024/39 |
| 30 | Dismantling of pole/ street light standard/ strut embedded in brick ballast foundation etc as required DSR-2018/12.41 |
| 31 | Supply & fixing of 75 mm x 90 mm shackle insulator/100 mm x 65 mm pin insulator including G.I Bolts/spindle nuts etc complete in all respect UPPWD-2018/620 |
| 32 | Supply & erection of \\"D\\" clamps of 50 mm x 6mm flat iron on steel tubular poles / steel rail poles with bolts, nuts etc complete in all respects including painting with aluminium paint UPPWD-2018/623 |
| 33 | Labour Cess and GST will be paid extra as per govt. orders Please Enable Macros to View BoQ information |