| 1 | Supply and laying of 3 core standered aluminium conductor XLPE (Cross linked polyethylene) insulated PVC bedded. Galvanised flat steel strip armoured cables confirming to 1.S. 7098 (Part-11 with latest amendments) 11 KV grade at a depth of 900 min below ground level over a cushion of 100 mm thick fine river sand all around and protected with well burnt bricks on sides and on top put across. The armouring of cable shall be properly connected with earth conductor by clamps etc. GNIDA 2/d |
| 2 | 11KV XLPE Cable 300x3C |
| 3 | S/E of Section Double pole structure on ST pole 410 SP-62 with 1/6 over length of poles grounted with cement conerete in 1:3:6 Cone cement: 3 coarse sand 6 Stone balleast) including plingthing of pole 30 em above grade level. plastering of plinth including excavation & back filling ete. The double pole structure consist of 100X50X2.24 mtr. & 75X40 mm 2.24 mtr. M.S. channel and bracings with M.S. clamp packing piece Nuts Bolts etc. The rates includes all materials labour T&P etc. required for proper completion I work as per direction of E/I GNIDA-28 |
| 4 | Supply. Delivery. Installation, Testing & Commissioning of 11 KV Out door type cable termination kit of 3 core cable for cable termination at the panel & transformer complete in all respects as required for proper completion of work. (650mm length) GNIDA-5/d (make Raychem/C.C.L/Frontec) |
| 5 | 3CX300 Sq.mm. |
| 6 | Supply. Delivery. Installation. Testing & Commissioning of 11 KV in door type cable jointing kit of 3 core cable for cable joint complete in all respects as required for proper completion of work. (650mm length) GNIDA-4/d (make Raychem/C.C.I./Frontee) |
| 7 | 3CX300 Sq.mm. |
| 8 | Supply & erection of strut consisting 410 SP-58 12 mtr long ST pole with M.S clamp complete with grouting ete complete in all respect etc as per Direction of Engineer in charge. GNIDA-30 |
| 9 | Supply & erection of stay set at least 3.5 Metres away from the pole complete with galvanised 19 mm día x1.80 Metre long stay rod. 30 cm x 30 cm x 6.3 mm anchor plate. thimble stay clamps. stay insulator. 19 mm x 600 double screw tightener. 7/4.00 mm G.1 stay wire etc. in 1:3:6 cement concrete complete in all respect.UPPWD-2018, S.N- 631 |
| 10 | S/F of one side cross arm made of 100x50x6mm M.S. channel 0.90mtr. Long & 50x50x6mm M.S. angle 1.0SMtr. Long with M.S. clamp, nut bolts etc. complete in all respect. GNIDA-34 |
| 11 | Supply and burying of 40mm dia x 4.5 metres long G.I. Pipe vertically for earthing having 12mm dia. Holes spaced 75mm apart drilled up to 2 metre from the bottom complete with earthing lead of No. 6 to 8SWG Gl wire in G.I. Pipe up to appron (and from appron to switch board the cost of G.I. wire and pipe will be extra) upto switch board, 30cm square C.I. box with hinged cover masonary enclosure, funnel at top, alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing, item no 701 |
| 12 | Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respect. Uppwd schedule 2018 item no 716 |
| 13 | S/F of 11 KV Dise with Gun fittings on cross arms/clamps lixed on poles including all Nut, belts & washer etc. for proper completion of work. (Jaishree, BIIEL. RR, Hindustan make) Approved rate FIS-134717 |
| 14 | S/F of Straight M.S. channel of 100X50 mm M.S. channel 2.5 mtr long on poles with packing, piece. M.S. clamp. Nut bolts etc. complete in all respect. GNIDA-SOR-2024, SN-33 |
| 15 | Supply & erection of overhead line with G.L. wire no. 8 to 4 SWG on poles/serivce bracket including binding etc. complete in all respect. (G.L. wire should use as a support to bind overhead line with it at interval of 5 mtr.) As per UPPWD Schedule-628 |
| 16 | S/L of 90mm dia. DWC pipe for drawing of power cable across the road by drilling of 120mm dia. at Imtr. below the road level thereby doing the work of providing DWC pipe by Trenchless method. Approved rate FTS-134717 SOR-2024 |
| 17 | Supply & fixing of anticlimbing device fabricated from G.1.(flat) of 25 mm x 6mm size in a shape of ring of the pole size. having G.I. flat pointed fins of length 225 mm in 8 nos. including all the materials, labour. T&P and other material required for proper completion for work and to the satisfaction of Engineer-in-Charge.as per uppwd schedule 2018 item no 635 |
| 18 | Supply and fixing danger board fabricated from 10 gauge M.S. Sheet as per 1.E. Rules. DPPOD-2018, SN-1109 |
| 19 | S/F of 11 KV Drop-out type fuse set channel type of Relco or equivalent make with insulators and other accessories required for proper completion of work. GNIDA-SOR-2024, S-N--46 |
| 20 | S/F of G.1. pipe 150 mm dia \\"B' class ZINDAL / TATA make including required material. T&P etc. complete in all respects. GNIDA-SOR-2024, S.N.-54 |
| 21 | Painting of the electric pole with two coat of Al-paint over red oxide primer complete in all respeet. (PWD-634) |
| 22 | S/E of D' clamps 50x6MM flat iron on steel tubular pole/steel rail pole with bolts, nuts etc. complete in all respect including with aluminium paint. (PWD-623 |
| 23 | Labour Cess and GST will be paid extra as per govt. orders Please Enable Macros to View BoQ information |