| 1 | Supply & erection of Steel tubular pole with 1/6 over all length of pole grouted with cement concrete in 1:3:6 (1) cement: 3 coarse sand: 6 stone ballast) including plinthing of pole 30 cm above the ground level, plastring of plinth including excavation back filling etc. The rates includes all materials labour & T&P. etc. required for proper completion of work as per direction of E/I. SOR-2025/27 |
| 2 | 410 SP-17, 8.5 mtr. (Approx wt. 92kg.) |
| 3 | Supply of 1.5mtr. long MS arm of size 60mm dia. X3.25mm thickness along with MS bracket of size 114.3mm diaX4.5mm thicknessX0.3mtr. long on steel tubular pole, complete in all respect including cutting, welding, threading, fabrication, nut & bolts and painting पूर्व स्वीकृत (FTS-133716) |
| 4 | Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 30 watt to 40 Watt. Confirming to IP66 Protection complete in all respect. (UPPWD-2018/1420) CAT-AA |
| 5 | Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 52 watt to 72 Watt. Confirming to IP66 Protection complete in all respect. (UPPWD-2018/1422) CAT-AA |
| 6 | Supply & fixing of MS rod for earthing with 2.5 m long. solid, 20 mm dia hot dipped galvanised MS rod buried till the top reaches 1.7 mts. Below the GL complete with bolts & nuts & Gl earth wire 7/14, SOR-2024/41 |
| 7 | Painting of the electric pole with two coat of Al-paint over red oxide primer complete in all respect. (UPPWD-2018/634) |
| 8 | Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect. UPPWD-2018/807 |
| 9 | 40 Α ΤΡΝ |
| 10 | Construction of Street light pole plinth with cement concrete complete in all respect. पूर्व स्वीकृत |
| 11 | S/F of Sintex type Junction Box of size 388X304X170mm with hinges and locking arrangement & M.S. clamp made of 50X6 mm flat, complete in all respect including 2 Nos. G.I. pipe 1.5\\" dia having 1.0 meter length each and chuck nut for cable connection etc. as per direction of E/I. (FTS-140395 E&M-3) |
| 12 | S/L of 90mm dia. DWC pipe for drawing of power cable across the road by drilling of 120mm dia. at 1mtr. below the road level thereby doing the work of providing DWC pipe by Trenchless method. SOR-2024/15 |
| 13 | Supply & laying of Aluminium conductor, XLPE insulated, armoured served, sheathed cable 1100 V grade at a depth of 750mm below ground level over a cushion of 75mm. thick sand alround and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S.clamps etc. of suitable size or as directed by the E/I, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. (CCI, Gloster, Asian, Universal, Nicco, ICL, make & for small works upto value of cable for Rs. 25.0 lacs Kalinga, Grandley make can be used) (UPPWD-2018/-501) |
| 14 | 3.5C x 25 sqmm. |
| 15 | 3.5 C x 70 sqmm. |
| 16 | S/F of street light panel cover of 2mm. Thick fibre sheet with 25X25X3mm. Angle iron frame on existing panel complete with Hings, locking arrangement & painting etc. complete in all respect. पूर्व स्वीकृत |
| 17 | Supply and wiring of submains with 2 nos. 2.5 sq mm & with 1 no earth wire of 1.5 sq mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in existing PVC conduit complete, including supply of all material, labour and T & P etc. required for proper completion of the work as directed by Engineer in charge. UPPWD-2018/291 |
| 18 | 2CX2.5+1.5 Sqmm. |
| 19 | Supply and fixing of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. UPPWD-2018/504 |
| 20 | 25 Sqmm. |
| 21 | 70 Sqmm. |
| 22 | Operation & Maintenace work of 1175 No. of LED + Street light point Rs. 19.49/- per point per month 32.20/- per point per month for cable infrastructure maintenance, total = 51.691-Say-52.00/- (Already approved by File no.-126210) per point per month including supplying and replacing all defective items e.g. LED street lights, cables, MCBS, junction box, panel complete infrastructure including all relevant items.Note:- Initial period of 2 years after date of Completion of work will be Defect liablity period (in this period Watch & Ward, Operation & Maintenance of light and any defect in the light and in cable infra network will be repaired/replaced by Contractor, No extra amount will be payble to contractor during this defect liability period. After completion of defect liabilty period Operation & Maintenance of 1175 No. street light points will be paid collectivly @ 52/- per point per month basis for next five years. (Rate approved in implementation of smart LED street lights and Installation of centeralized control and monitoring, system with O&M of2 years, Gr. Noida. File no-126210 Taken approved rates without GST) FTS-133716 |
| 23 | Part-B |
| 24 | Supply & fixing of 16 mtr High mast shaft of approved make with rising system hot dip glavanized inside & outside dip, heaving pole sheet thickness 3 mm. Top dia minium 150 mm, Bottom dia 360 mm base plate 32 mm thick suitable for wind velocity as per IS 875 part 3 & having no circumferential weld, with accessories for high mast such as head frame suitable for 6 to 12 luminaries & its control gear boxes 1.5 HP power tool moter, 3 point suspension system with steel wire rope 6 mm dia, double drum winch, including making suitable foundation as per manufature drawing/ site reuiment along with foundation bolts nuts, washers, anchor plates etc completee in all respect. UPPWD-2018/652 |
| 25 | Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 200 Watt. Confirming to IP 66 protection complete in all respect. CAT-AA UPPWD-2018/1455 |
| 26 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. UPPWD-2018/501 |
| 27 | 3.5CX50Sqmm |
| 28 | Supply and fixing of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. UPPWD-2018/504 |
| 29 | 25 Sqmm. |
| 30 | 50 Sqmm. |
| 31 | S/L of 90mm dia DWC pipe for drawing of power cable across the road by drilling of 120mm dia at 1mtr. Below the road level the work should be done by manual Trenchless method. Complete in all respect. GNIDA SOR-2024 (S.No-15) |
| 32 | Supply and burying of 600mm x 600mm x 6mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead of one no. 8 to 10 SWG GI wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing (This will apply for earthing of poles also). UPPWD-2018/702 |
| 33 | Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respect. UPPWD-2018/716 |
| 34 | Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect. UPPWD-2018/807 |
| 35 | 40 Α ΤΡΝ |
| 36 | Labour Cess and GST will be paid extra as per govt. orders Please Enable Macros to View BoQ information |