| 1 | M&L for Surface dressing n exc 15cm deep in soft/loose soil as in berm. |
| 2 | Returning, filling in,incl spreading,levelling,watering and well ramming in layers not exc 25CM soft/loose soil |
| 3 | M&L for Removing excavated soil to a dist exc.250m & n.exc 1.00 Km |
| 4 | Excavation in trenches n exe 1.5 mtr wide and n exe 1.5 mtr deep for foundation etc all as specified and directed |
| 5 | M&L Cement concretec D2 (1:4:8) 40 mm graded aggregate in foundations,filling and mass concrete all as specified and directed |
| 6 | M & L for providing precast cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in landings, cover slabs and similar work including necessary formwork and 32mm dia weep holes set in cement mortar 1:6 complete all as specified and directed. |
| 7 | M and L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips |
| 8 | M & L for mild steel round bars(Fe-410- (Gde.E-250)Part- I quality-A or Fe 290 (Gde -E-165) 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips/embedded in concrete complete all as specified and directed. |
| 9 | S and F of framed work such angles or tees/FI with web and flanges cut to shape,drilled and counter-sunk for screw,incl bending and welding angles,as necessery gusset plates not les than 10mm thick,reveting etc not exc 10 kg each brackets confirming toFe-290 gde-E-165 |
| 10 | M & L for preparation of new or previously untreated surfaces of steel any description over 10cm in width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. |
| 11 | Sand filling under floors for cushioning of including watering and consolidation |
| 12 | M & L for machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-40 Grade with grey cement and pigment complete all as specified and directed. |
| 13 | M & L for heavy duty endura parking coloured tiles, 12-15 mm thick layer over screed bed with neat cement complete all as specified and directed by Engr-in charge. |
| 14 | M & L for Providing, cement concrete type B1, 1:2:4 (using 12.5 mm graded stone aggregate) in cills, steps; seismic and other similar bands, plinth courses copings including necessary form work all as specified and as directed |
| 15 | M&L brickwork with sub class 'B' old size bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified. |
| 16 | M&L for rendering 15mm thick external surfaces on brick/concrete surfaces in CM 1:4 finished even and smooth without using extra cement with WPC 2% by wt of cement. Note:-WPC measured and paid separatly |
| 17 | M&L for moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering all as specified |
| 18 | Excavation in trenches, not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm area on plan and not exceeding 1.5 meter in depth and getting out in Hard /dense soil complete all as specified and directed. |
| 19 | M & L for 40 mm thick Cement Concrete M-15 Nominal Mix (using 12.5 mm graded stone aggregate) as in damp proof course (DPC) to horizontal or vertical surfaces including necessary form work and mixing of water proofing compound as per manufacturer’s instructions complete all as specified and directed. NOTE: - water proofing compound will be measured and paid separately. |
| 20 | Supply only Integral water proofing compound (WPC) complete all as specified and directed. |
| 21 | Removing of excavated Soil n exc 50m and depositing where directed at a level n.exc 1.50m above the starting point complete all as specified and directed |
| 22 | M & L for rendering 10mm thick internal surfaces on brick work in cm 1:6 in and finishing surfaces even and fair without using extra cement complete all as specified and directed |
| 23 | M & L for rendering 15mm thick in two layers on external surfaces on brick/concrete in CM 1:4 finished even and smooth without using extra cement with WPC complete all as specified and directed . Note :- WPC measured and paid separatly |
| 24 | M&L preparing newly plastered surfaces of wall and applying complete wall with 1.0 mm Wall putty and making smooth surfaces and applying two coats of Oil bound distemper over a coat of primer all as specified and directed . |
| 25 | Preparing New plastered surfaces and applying Two coats of cement base paint on surfaces of walls over one coat of white wash complete all as specified and directed . |
| 26 | M & L for PCC 1:2:4 type B-1, 25 mm thick, using 20mm graded stone aggregate complete all as specified and directed. |
| 27 | M & L for light shed virified ceramic tiles 7.5 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and incl 15mm thick screed bed or bedding layer with CM 1:4 complete all as specified and directed .Notes : Shade of the tile including colour, design and pattern shall be approved by AGE. |
| 28 | M & L for light shed virified ceramic tiles 7.5 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in skitting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and incl 10mm thick rendering bed or bedding layer with CM 1:4 complete all as specified and directed .Notes : Shade of the tile including colour,design and pattern shall be approved by AGE. |
| 29 | S & F of Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and directed. |
| 30 | S&F 4 mm thick HPSC (High Pressure steam cured) pre-primed textured designer board, water resistant, be placed in the grid system complete all as specified and directed . |
| 31 | S & F Powder coated aluminium frame/shutters for Door,windows, ventilators sliding/openable etc icluding joining cleat for fixing, locking arrangement,rubber beading, screws,etc complete all as specified and directed Note :(i) Glazing and wire mesh shall be measured and paid separetely only as the labour element included in the relavent item.(ii) Item shall be paid as per weight of aluminium section (iii) The rate quoted shall be inclusive of the cost of neoprene beading, glazing pin, screws and powder coated fittings such as locking arraangement etc as required, which shall not be measured for arriving the weight.(iv) The rate shall also be inclusive of complete packing with silicon gel around contacting surfaces of aluminium work, and including matching the existing. |
| 32 | S & F for 6mm Powder coated decorative aluminium grill complete all as specified and directed |
| 33 | S&F 5mm thick tinted glass in aluminium doors & windows with rubber packing glass complete all as specified and directed |
| 34 | S&F in repairs aluminium (Die cast ) body door closer hydraulically regulated designation No-3 universal type suitable for door shutters of 85 to 1000mm in width and of weight between 61 yo 80 kg snf complete all as specified and directed . |
| 35 | S & F 5 MM thick ACP Sheet fixed to alm frame work as specified and as directed |
| 36 | S&F in Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.18mm and fixed with beeding/Staples directed Supply and laying river bed fine sand in trenches/ ducts 15 cm under cable and 8 cm above the cable for cushioning / protection to cable including spreading, levelling and get thick 18cm after hand punning complete all as specified and directed at site. Please Enable Macros to View BoQ information |