| 1 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: All kinds of soil. |
| 2 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 3 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 4 | Providing and laying of damp proof course of 40 mm thick with cement concrete (1:2:4),mix with 12.50 mm thick crushed stone aggregates. |
| 5 | Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns etc. for mass concrete |
| 6 | Brick work with FPS bricks of class designation 75 in foundation and plinth in cement mortar in 1:6 mix incl carraige of bricks upto site of work complete including extra upto floor v level including carraige and head load |
| 7 | Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level. |
| 8 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level : 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 9 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level(Thermo-Mechanically Treated bars of grade Fe-500D or more.) |
| 10 | Centering and shuttering including strutting, propping etc :Suspended floors, roofs, landings, balconies and access platforms. |
| 11 | Edges of slabs and breaks in floors and walls (upto 200mm wide) |
| 12 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angles 40x40x6mm for diagonal braces |
| 13 | 15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 6 ( 1 cement : 6 fine sand) |
| 14 | 12 mm thick cement plaster in 1:6 cement mortar in walls using coarse sand. Including curing and carriage |
| 15 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete.e.In colour such as White, Ivory, Grey, Fume Red Brown. |
| 16 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shadesexcept burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 17 | Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : White Vitreous China Angle back wash basin size 400x400 mm with single 15 mm C.P. brass pillar tap |
| 18 | Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931 |
| 19 | Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm) |
| 20 | Painting of doors and windows with ready mixed synthetic enamel paint of approved brand and manufacture in all shades. |
| 21 | Colour washing such as green blue or buff to give an even shade New work (two or more coats) with basecoat of whiting |
| 22 | Making plinth protection 50mm thick with cement conc .(1:3:6) ,20 mm nominal size of stone aggregates over 75mm bed of dry brick ballast,40mm nominal size of well rammed and consolidated and grouted with fine sand including finishing the top smooth. |
| 23 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 24 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc. 15mm nominal outer dia pipes. |
| 25 | Providing and fixing brass bib cock of approved quality. 15 mm nominal bore |
| 26 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittings complete: Semi rigid pipe 32 mm dia |
| 27 | Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes 110 mm diametre |
| 28 | Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.Bend 87.5° 110 mm bend |
| 29 | Electric wiring with 1.5 sqm coppper cable including 20mm dia 2 mm thick PVC pipe 5 amp with socket box connnection to the main pole completed as dircted by the site engineer incharge |
| 30 | Providing and placing on terrace polyethylene water storage tank ISI:12701 marked indicating BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet ,outlet and overflow pipes but without fitting and the base support for tank (syntex,star,lotus or equivalent having valid ISI License. |
| 31 | Carriage 0f material by mechanical transport including loading ,unloading and stacking completed sand lead up to 20 km |
| 32 | Carriage 0f material by mechanical transport including loading ,unloading and stacking completed stone aggreate lead up to 20 kM |
| 33 | Carriage 0f material by mechanical transport including loading ,unloading and stacking completed brick lead up to 25 kM Please Enable Macros to View BoQ information |