Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | CIVIL WORKS |
| 2 | INTAKE WELL |
| 3 | Detailed hydrological and geological survey, Site Survey, Testing for bearing capacity of soil, Design, obtaining necessary approvals and Construction of INTAKE structure / well (Capacity 18.50 MLD) Cum Pump House and Approach bridge ,Dewatering arregement, well sinking, Approach Channel Shoring for Coffer Dam including removal of coffer dam. Cost includes all material, Tools & Plants and labour complete for construction of said intake well. Cost includes all necessary river protection works and all necessary arrangements to ensure required raw water intake in all seasons (especially for Dry weather flow) complete in all respect as directed by Engineer –in-charge. |
| 4 | WATER TREATMENT PLANT |
| 5 | Detailed Geographical and hydrological Survey, Site investigation, Testing for bearing capacity of soil, Designing, obtaining necessary approvals with Supply of all materials labour ,Tools & plants for Construction of Water Treatment Plant of 7 MLD capacity (Net out-put capacity i.e. excluding overloading,add 20 % overloading i.e 8.4 MLD) water treatment plant with PLC-SCADA based automation with space saver/ compact and efficient modern treatment technology with construction of MCWR 550 KL capacity. The Treatment Plant as per approved hydraulics essentially consists of the units for : Inlet Chamber, Pre-Sedimentation Unit, Settling Tank ,Venturi Flume ,Flash Mixer, Alum Solution, Tank Chemical House, high to ultra highrate clarifiers, Clarifloculator, high rate filtration unit, Rapid Graity Filters Back Wash Tank Air Blower Post Chlorination Inlet, Outlet , Back Wash Gutter , Troughs , Weirs Reuse of Back Wash Water Thickened Sludge Sump & Pump House Filterate Sump & Pump House Clear Water Sump for Backwash,Clear Water Outlet Chamber Sludge Drying Beds. All other required units. Cost includes all necessary Civil , E&M and SCADA works as per approved by competent authority complete in all respect as directed by Engineer –in-charge. |
| 6 | OVER HEAD TANK |
| 7 | Design, Supply of all materials, labour, T&P etc required for construction of Intz type RCC Over Head Tank including various works like - soil testing, Ventilator and Water level indicator, Lightening conductor, C.I. D/F Verticle pipes (Inlet Pipe, Outlet Pipe, Overflow Pipe & Washout Pipe), duck foot bend, puddle collers and bell mouths, Sluice valve on inlet, outlet & washout pipe and Valve Chamber, Bye-pass arrangement of OHT, Flooring, Apran & Drain (100 mm thick PCC of 1:2:4 & 100 mm thick RCC of 1:1.5:3), Floor shall be 30 cm above the finished ground level of Campus, Two coat apex painting over one coat primer of approved colour after finishing of RCC surface with grinder, repair of pin holes, unevenness., Railings - G.I. Pipe railing around stair case (both sides), balcony & top dome periphery, S.S ladder from opening of top dome to bottom dome, Stair case (Seperate two column based RCC staircase and 1 m wide balcony with arrangement of M.S Gate and Jali), Food grade epoxy coating of FOSROC / Ciba-Geigy or reputated brand on inside surface area of water container after testing for water tightness, of capacity and staging mentioned as under: For bidding purpose, bearing capacity of soil shall be considered as 8t/sq.m. Working design shall be based on the SBC determind after soil investigation / 8 tonne/sqm whichever is less complete in all respect as directed by Engineer –in-charge.Note :- The bid price of Over Head Tanks is to be submitted considering net safe allowablebearing capacity as 8 t/m2, keeping the minimum foundation depth to be 2.5 m below existing ground level at the site of work.The successful bidder will be required to investigate the soil bearing capacity. If net safe allowable bearing capacity is found to be equivalent or more than 8 t/m2, the design of OHT will be based on 8 t/m2 capacity. However, in case the net safe allowable bearing capacity is found to be below 8 t/m2, then the design of OHT will be based on the actual bearing capacity.To accommodate for the additional cost required, in the eventuality of net safe allowable bearing capacity falling below 8 t/m2, the payment shall be made as extra item of work. |
| 8 | CPT TANK 50 KL, 10 M staging |
| 9 | OHT of 1200 KL Capacity, 22 m staging (Zone 2) Inlet 250mm, Outlet 350mm, Over flow 250mm, Washout 100mm |
| 10 | OHT of 1300 KL Capacity, 24 m staging (Zone 3) Inlet 300mm, Outlet 350mm, Over flow 300mm, Washout 100mm |
| 11 | CLEAR WATER RESERVOIR CUM PUMP HOUSE |
| 12 | Design, supply of all material, labour, T&P etc. required for construction of Circular, R.C.C Clear Water Reservoir cum pump house including various works like soil testing, 1 m wide stair case with stainless steel hand railing to go inside reservoir, sump below the pump house area, stainless steel railing over the R.C.C slab of reservoir, Granular texture finish on exterior surface of pump house, gantry beam, food grade epoxy coating of FOSROC / Ciba-Geigy or reputated brand on inside surface area of water container after testing for water tightness, of capacity complete in all respect as directed by Engineer –in-charge.Note : The bid prices of Clear Water Reservoir / Pumping Stations are to be submitted considering the depth of excavation may extend up to 6 m BGL. |
| 13 | 400 KL Capacity in Zone-2 |
| 14 | 350 KL Capacity in Zone-3 |
| 15 | Supply of all material, labour, T&P required for repairing of Old existing CWR 360KL (Zone-1) Work involved in repair of old OHT all as per following-I-Surface cleaning, sealing of internal & external cracks in concrete structure by epoxy grouting and cement grouting.II-GI hand railing repair including for partially replacement of corroded pipes including vertical pipes ends in concrete which are dammaged due to corrosion.III-Replacement of old ladder to SS ladder.IV-Hydro testing of CWR.V-Cement/Epoxy grouting for water tightness of leakge observed during hydro testing.VI-The food grade epoxy cotting of FOSRAC/Ciba-geigy of reputed brand on inside surface area of water container after testing for water tightness.VII-Dismentling and reconstruction of floor inlet, outlet, over flow and wash out valves chambers.VIII-Replacement of all sluice valves and construction of sluice valve chambers. (inlet, outlet and wash out).IX-Replacement of dameged CI D/F pipes as required.X-Replacement of water level indicator and lightening conductor as required.XI-Two coat apex ultima painting over one coat primer of approved color after finishing of RCC surface with grinder, repairing of pin holes, unevenness etc complete required for completion of all works as directed by Engineer –in-charge. |
| 16 | Construction of Master Control Room as per type design (Size - 8.0m x 5.0m x 4.0m) including supply of all materials, labour, T&P etc. required for proper completion of the work as per the directions of Engineer-in- charge. |
| 17 | Construction of HT panel Room as per type design (Size - 5.0m x 4.5m x 4.0m) including supply of all materials, labour, T&P etc. required for proper completion of the work as per the directions of Engineer-in- charge. |
| 18 | Construction of LT panel Room as per type design (Size - 5.0m x 4.5m x 4.0m) including supply of all materials, labour, T&P etc. required for proper completion of the work as per the directions of Engineer-in- charge. |
| 19 | Construction of Meter Room as per type design (Size - 4.0m x 3m x 3m) including supply of all materials, labour, T&P etc. required for proper completion of the work as per the directions of Engineer-in- charge. |
| 20 | Supply of ISI mark DI K-9 and K-7 S&S pipes (push on joints) of following class and Rubber gasket of EPDM Quality and including Supply of D.I. S/S or flanged Specials conforming to I.S. 8329/2000 Suitable for above D.I. S/S F.O.R. destination and all statutary duties and taxes, third party inspection charges, transit insurance, freight, transportation to store/ site of work, unloading, stacking etc. complete as directed by Engineer –in-charge. |
| 21 | D.I. Pipe Class-K9 |
| 22 | 150mm dia |
| 23 | 300mm dia |
| 24 | 250mm dia |
| 25 | 350mm dia |
| 26 | 400mm dia |
| 27 | D.I. Pipe Class-K7 |
| 28 | 200mm dia |
| 29 | 250mm dia |
| 30 | 300mm dia |
| 31 | 350mm dia |
| 32 | 400mm dia |
| 33 | Supply of High Density Polyethelene Pipes (HDPE (PN-6)/PE-100), conforming to IS 4984 / 14151 / 12786 / 13488 in coils/ standard lengths and inluding Supply of HDPE Specials & jointing material like electro-fusion coupler, flanged joint, conforming to I.S.- 4984/2016 with solvent cement suitable for above HDPE pipe F.O.R. desination rates per meter (exclusive of GST) in Rs. every where in UP upto stores of consignees inclusive of third party inspection charges, packing and forwarding charges, transit insurance charges, road transportation chaloading & stacking the same etc. complete as directed by Engineer –in-charge. |
| 34 | 160 mm dia HDPE Pipe PN-6 |
| 35 | 140 mm dia HDPE Pipe PN-6 |
| 36 | 110 mm dia HDPE Pipe PN-6 |
| 37 | 90 mm dia HDPE Pipe PN-6 |
| 38 | Excavation for pipe line in ordinary soil (loam, clay, sand) with lift up to 1.5 m and lead up to 50 m and including filling back, watering and ramming of excavated earth into the trenches and removal and disposal of surplus earth within 50 meters.(Dia+0.5) |
| 39 | In ordinary soil |
| 40 | 0 - 1.5 |
| 41 | Carting, lowering, laying and jointing with SBR ruber gaskets D.I. K-7/ D.I. K-9 pipes of following dia & pressure including all specials, to site of work, lowering them into trenches, laying true to alignment and gradient, in proper position, cutting of pipes, making of joints including cost of jointing materials and rubber rings, labour, T&P, including hydraulic testing etc. complete as directed by Engineer in-charge. It includes provision for making of alignment on city roads, making trial pits to investigate location of various under grounds services like telephone cables, electric cable, existing pipe lines and sewer lines etc. arrangements for diversion of traffic and associated works etc. with supply of all necessary equipment, materials, labour and T&P etc. complete required for completion of work. The trenches shall be properly barricaded and fenced off wherever necessary. Red flags and caution boards during day and red lights during night shall be displayed so as to avoid any accidents and updating survey of laid pipe on Gati Shakti Portal and or directed by Engineer-in-Charge.Note : Only SBR Rubber gaskets to be used as per IS-5382 and IS- 12820. |
| 42 | D.I. Pipe Class-K9 |
| 43 | 150mm dia |
| 44 | 300mm dia |
| 45 | 250mm dia |
| 46 | 350mm dia |
| 47 | 400mm dia |
| 48 | D.I. Pipe Class-K7 |
| 49 | 200mm dia |
| 50 | 250mm dia |
| 51 | 300mm dia |
| 52 | 350mm dia |
| 53 | 400mm dia |
| 54 | Lowering, laying and jointing of HDPE pipe in proper position using electrofusion specials including supply of all Electrofusion specials & hydraulic testing as per relevent IS Code complete with all accessories like Electrofusion machine, power arrangements, hydraulic testing arrangements, labours, material etc. complete and updating survey of laid pipe on Gati Shakti Portal and or directed by Engineer-in-Charge. |
| 55 | 160 mm dia HDPE Pipe PN-6 |
| 56 | 140 mm dia HDPE Pipe PN-6 |
| 57 | 110 mm dia HDPE Pipe PN-6 |
| 58 | 90 mm dia HDPE Pipe PN-6 |
| 59 | Supply of following types of C.I. valves confirming to the I.S. specification inclusive cost of jointing materials (Rubber gasket of EPDM Quality) including all statutary duties and taxes, third party inspection charges, transit insurance, freight, transportation to store/ site of work, unloading, stacking etc. complete as directed by Engineer –in-charge. |
| 60 | 400 mm dia |
| 61 | 350 mm dia |
| 62 | 300 mm dia |
| 63 | 250 mm dia |
| 64 | 200 mm dia |
| 65 | 150 mm dia |
| 66 | 100 mm dia |
| 67 | Carting of CI Sluice valves of Following sizes to the site of works Lowering them into already Prepared trenches and fixing them In position including supply of Jointing materials such as bolt nut, Rubber insertion white lead complete with Excluding values and specials Required but including the testing etc. complete as directed by Engineer –in-charge. |
| 68 | 400 mm dia |
| 69 | 350 mm dia |
| 70 | 300 mm dia |
| 71 | 250 mm dia |
| 72 | 200 mm dia |
| 73 | 150 mm dia |
| 74 | 100 mm dia |
| 75 | Trenchless Technology Crossing of rising main 400mm dia D.I. Pipe in mixed soil Complete in all respect as directed by Engineer –in-charge. |
| 76 | Supply of all materials, labour, T & P etc. required and construct thrust blocks at the bends and below the Valves. |
| 77 | Supply of the following sizes of C.I. Double flanged scour valves as per I.S. 780 class-1 working pressure 10 kg/Sqcm F.O.R Destination including all taxes and insurance.complete in all respect as directed by Engineer –in-charge. |
| 78 | 80 mm dia |
| 79 | Carting of scour valves to the site of works lowering them into already Prepared trenches and fixing them In position including supply of Jointing materials such as bolt nut, Rubber insertion white lead complete with Excluding values and specials Required but including the testing etc. complete Excluding values and specials required but including the testing etc. complete in all respect as directed by Engineer –in-charge. |
| 80 | 80 mm dia |
| 81 | Supply of 25 mm dia screwed down type air valve with gun metal seat at site stone including all taxes in all respect as directed by Engineer –in-charge. |
| 82 | Carting of 25 mm dia screwed down air valves of following sizes to the site of works lowering them into already prepared trenches and fixing them In position including supply of Jointing materials such as bolt nut, Rubber insertion white lead complete with Excluding values and specials Required but including the testing etc. complete Excluding values and specials required but including the testing etc. complete in all respect as directed by Engineer –in-charge. |
| 83 | Supply of underground sluice valves type fire hydrant consisting of 80 mm dia tail pieces, 80 mm dia duck foot band and 63 mm dia standard make iron coupling with cap and chain etc. complete to ISS 909 at site including all taxes in all respect as directed by Engineer –in-charge. |
| 84 | Carting of 80 mm dia flanges fire hydrant of the site of works lowering them into already prepared trenches and fixing them In position including supply of Jointing materials such as bolt nut, Rubber insertion white lead complete with Excluding values and specials Required but including the testing etc. complete Excluding values and specials required but including the testing etc. complete in all respect as directed by Engineer –in-charge. |
| 85 | Dismantling of following type of road surfaces for laying of pipe line and house connection work including sorting out of serviceable materials and disposal of unserviceable materials including supply of all materials, labour, T&P etc. required for proper completion of the work. |
| 86 | B.O.E. ROAD |
| 87 | BITUMINOUS ROAD |
| 88 | C.C. ROAD |
| 89 | INTERLOCKING TILES |
| 90 | Permanent re-instatement of following type of road surfaces after laying of pipe line including supply of all materials, labour, T&P etc. required for completion of work. It also includes necessary excavation required for preparation of trench for reinstatement of road, disposal of surplus unserviceable material, watering, ramming, cleaning of surface for proper completion of the work as per directions of engineer-in-charge. |
| 91 | BOE (Brick on Edge) RoadConstruction of BOE road including supply of all materials, labour, T&P etc. required for proper completion of work as per following thickness:-Ist class brick shall be used for reinstatement of BOE road. Sand = 25mm thick local sand layer for preparation of surface |
| 92 | Bitumen road TYPE AConstruction of bitumen road as per UPPWD specification including supply of all materials, labour, T&P etc. required for proper completion of work as per following thickness:-GSB G-1 (One coat) (90-40 mm) = 12.5 cm G -2 (one coat) (45-63 mm) = 7.5 cmG - 3 (one coat) (22.5 - 53 mm) = 7.5 cm BM (One coat) = 7.5 cmSDBC (One coat) = 2.5 cm |
| 93 | Cement Concrete RoadConstruction of Cement Concrete road including supply of all materials, labour, T&P etc. required for proper completion of work as per following thickness:-PCC = 100 mm,1:4:8 (cement, coarse sand & stone ballast of 20-40 mm)CC =100 mm, 1:2:4 (cement, coarse sand & stone ballast of 16-20 mm) |
| 94 | C.C. Interlocking Tiles Road Type AConstruction of C.C. Interlocking Tile road including supply of all materials, labour, T&P etc. required for proper completion of work as per following thickness:-PCC = 100 mm,1:4:8 (cement, coarse sand & stone ballast of 20-40 mm) Sand = 50 mm thick local sand lair for preparation of surfaceNote : 100 mm thick rubber moulded interlocking tile shall be used for construction of interlocking tile road. |
| 95 | Supply of all materials, labour T&P etc. required and construct surface box/masonry type sluice / scour valve chamber as per type design including supply and materials labour, T&P etc. complete in all respect as directed by Engineer –in-charge. |
| 96 | Surface box type |
| 97 | Masonry type |
| 98 | Supply of all materials, labour T&P Etc. required and construct 350 x 350 x 500 mm size air valve chamber as per type design including supply and fixing the 500 mm dia CI manhole cover complete in all respect as directed by Engineer –in-charge. |
| 99 | Supply of all materials, labour T&P Etc. required and construct 750 x 450 mm size fire hydrant chamber as per type design including supply and fixing the 500 mm dia CI manhole cover complete in all respect as directed by Engineer –in-charge. |
| 100 | Trenchless Technology Crossing of Pipe-200 MM DI Pipe in Mixed Soil complete in all respect as directed by Engineer –in-charge. |
| 101 | Provision for crossing of Nalas (0.5m to 2.0 m width) for laying of pipe line including necessary specials, T&P and arrangement of diversion of water, baricatings etc required, with dismantelling of drains and reconstruction of same as per type design of the existing drain complete in all respect as directed by Engineer –in-charge. |
| 102 | 0.0 - 3.5 m |
| 103 | 3.5 - 7.0 m |
| 104 | 3.5 Culvert Crossing |
| 105 | Providing and making NEW water supply house connection from distribution pipe line of following diameters using 20 mm dia pipe (HDPE pipe (PE 100/ PN 12.5) below ground and medium class GI pipe above ground), saddle (electro-fusion tapping saddle for making connection with HDPE distribution pipeline, DI strap saddle, ferrule, for making connection with distribution pipeline other than HDPE), compression fittings (FTA, MTA etc.), ball valve, specials, including supply of all materials, labour, T&P etc. required for proper completion of the work. It also includes excavation, refilling of pit required for making house connection and updating data on Gati Shakti Portal as per direction Engineer-in-charge. |
| 106 | for 90 mm - 110 mm dia. |
| 107 | for 125 mm -160 mm dia. |
| 108 | for 180 mm -250 mm dia. |
| 109 | for 300 mm dia. |
| 110 | for 350 mm -500 mm dia. |
| 111 | Providing and shifting EXISTING water supply house connections from newly laid distribution pipe line of following diameters using 20 mm dia pipe (HDPE pipe (PE 100/ PN 12.5) below ground and medium class GI pipe above ground), saddle (electro-fusion tapping saddle for making connection with HDPE distribution pipeline, DI strap saddle, ferrule, for making connection with distribution pipeline other than HDPE), compression fittings (FTA, MTA etc.), ball valve, specials, including supply of all materials, labour, T&P etc. required for proper completion of the work. It also includes excavation, refilling of pit required for making house connection and updating data on Gati Shakti Portal as per direction Engineer-in-charge. |
| 112 | for 90 mm - 110 mm dia. |
| 113 | for 125 mm -160 mm dia. |
| 114 | for 180 mm -250 mm dia. |
| 115 | for 300 mm dia. |
| 116 | for 350 mm -500 mm dia. |
| 117 | Construction of compound wall comprising of RCC Columns @ 3.0m c/c distance with beam atplinth and top, brick work in 1:4 of as per type design including supply of all material, labour, T& P etc complete. |
| 118 | Supply and fixing 3.60 m wide MS main gate & 1.0 m wide a wicket gate with RCC Columns as per type design & drawing including primer and painting, meterial, labour, T&P etc all complete as per direction Engineer-in-charge. |
| 119 | Providing and laying in position reinforced cement concrete (mix 1:2:4) for construction of Square drain, size 250 mm x 250 mm, over PCC 1:4:8, including batching, mixing, placing, vibrating, curing, formwork, finishing, including cost of all material and labor, tools and plants required with transportation, steel, loading, unloading, etc., complete for all leads and lifts and as perspecifications etc required for proper completion of the work as per direction Engineer-in-charge. |
| 120 | Construction of following types of Road/ flooring for development of CWR / OHT campus and Provide all materials, labour T&P etc. required for proper completion of work and construct Interlocking Road approach road in water works campous at WTP, Intake well to WTP and Zone 2 & 3 required as per site condition as per direction Engineer-in-charge. |
| 121 | Aproch C.C. Interlocking Tiles RoadConstruction of C.C. Interlocking Tile road including supply of all materials, labour, T&P etc. required for proper completion of work as per following thickness:-PCC = 100 mm,1:4:8 (cement, coarse sand & stone ballast of 20-40 mm) Sand = 50 mm thick local sand lair for preparation of surfaceTiles = 100% newNote : 100 mm thick rubber moulded interlocking tile shall be used for construction of interlocking tile road. |
| 122 | Providing and laying in position reinforced cement concrete (Mix 1:1.5:3) for construction of thurst block at bends of feeder main, rising main & distribution system including batching, mixing, placing, vibrating, curing, formwork, finishing, including cost of all material and labor, tools and plants required with transportation, loading, unloading, etc., complete for all leads andlifts etc required for proper completion of the work. |
| 123 | Providing H.Y.S.D steel reinforcement for reinforced cement concrete work including straightening, cutting, bending, hooking, placing in position, lapping and/ or welding wherever required, tying with binding wire and anchoring to the adjoining member wherever necessary asper design, including cost of materials and labor complete as per drawings. |
| 124 | Construction of Staff Quarter (RCC framed structure), as per type design and drawing each for pump operators & other staff including structural design and drawing, supply of all materials, labour, T&P etc. required for proper completion of the work as per the directions of Engineer-in-charge. |
| 125 | Staff Quarter Full Set |
| 126 | Staff Quarter Half Set |
| 127 | ELECTRICAL & MECHANICAL WORKS |
| 128 | PUMPING PLANT AND ACCESSORIES FOR INTAKEWELL |
| 129 | SITC of Vertical type self-oil lubricated statically, dynamically, hydraulically balanced turbine pump capable of discharging at the following duty condition as given below due to all causes with surface discharge head confirming to IS:1710 and as amended as on date with accessories as per IS 5120/1977(Reconfirmed 2011) and as amended thereafter to suit the site condition.The Pump Bowl assembly and casing shall be CI IS 210 FG: 260 with suitable coating inside casing of 500 DFT, suitable for protection against corroision,erosion and prevent oxidation.Impeller and Wearing / Neckring shall be Duplex stainless steel CD4MCu (Chromium-24.5% minimum,Carbon < 0.04% ) as per ASTM A890 GrlA or DIN 1.4474-EN 10088, Hardness 220-260 BHN,pump shaft-Stainless steel AISI 410, pumps and line shaft sleeve - stainless steel with ceremic coating 700 BHN,Strainer-SS 304,coupling between pump ang motor - Flexible pin bush type and bearings shall be Anti friction L-10 with 60000 Hrs life at 1450 rpm. 21 mtr/suitable length column assembly, with vertical hollow shaft. Squirrel cage induction motor(IS:126152011/IEC 60034-1) suitable for the above pump continuous rated TEFC IP-55 with Class 'F' insulation for operation in AC, three Phase/50 HZ (±5%), 415V (±10%), running with a speed of pump. Capacity as follows :- |
| 130 | 2600 LPM / 82 Mtr. HEAD / 75 HP MOTOR (2w+1s) |
| 131 | MAIN PIPING :-SITC of 200mm Main piping & valves complete of suitable size and quantity required for delivery side, bye pass arrangement and 250mm common Header upto 1 m. outside the pump house along with 250 x 200 x 250 mm A/F Tee (3 Nos), 250 mm bend (01 Nos), 250 mm blind flange (01 Nos), D/F Pipes suitable size all necessary nuts, bolts, rubber packing, M.S Support for pipe,mechanical joints (04 Nos) etc. complete in all respect as per site conditions. |
| 132 | Motor operated actuator with sluice valve :- SITC of DI/DF sluice valve with Electrically integrated actuater (Totally enclosed, weather-proof and dust proof construction with IP-67, protection class suitable for installation in any position without lubrication, leakage or other operational difficulty with special grease filled gear box and suitable for manual operation for emergency which will automatically dis-engage on restoration of power to motor and with 10 watt single phase space heater and continuous local mechanical position indicator and individually replaceable counter gear assembly and with two torque and four limit switches with S.S. flap and operated with gear driven cams and of rating 250 Volt, 5 Amp, AC/DC, torque switch dial and with TEFC squirrel cage induction) operated suitable to SCADA operation sluice valve having body door cover of graded in cast iron to IS:210 Gr.Fg.260 body and door rings of SS ASTM A743 Gr.CF8 and bearing block of leaded tin bronze to IS:318 Gr.LTB2 hinge pin of stainless steel AISI:431.Valves generally conform to IS:5312.Flanges to be drilled as per IS:1538 Part-IV &VI. Valves are suitable for hydrostatic test pressure of 10Kg./Cm2 for seat and 15Kg./Cm2 for body(PN-1.0) of following sizes |
| 133 | Actuator with Sluice Valve of size :- 200mm for pumps |
| 134 | Actuator with Sluice Valve of size :- 250mm for common header |
| 135 | Non return valve :- SITC of DI/DF Single Door/ Multi Door Non return/reflux valve conforming to IS:5312/2003(part I & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing . |
| 136 | 200 mm Dia for pumps |
| 137 | 250 mm Dia for common header |
| 138 | CE/UL Certified Electromagnetic flow meter :- SITC of CE/UL Full BorecElectromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) , Pressure : up to 1.0 MPa, Process temp: - 50 deg C, Flow/Meter Tube : SS 304, Electrode : SS AISI 316L / Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement ‘of IEC 60529, Accuracy : + 0.5 % M.V. velocity 0.3 to 10 m/s, Transmitter/ signa convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 5OHz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parameters and totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable. |
| 139 | Size 250mm for common header |
| 140 | ELECTRICAL ITEMS:- |
| 141 | Supply & laying of 1.1KV grade XLPE insulated unarmured multi strand copper conductor cable of 3C x 35 sq.mm from MCC Panel to respective Motors with lugs etc. (copper conductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I / IS :7098 P I) |
| 142 | SITC of Air Cooled Variable frequency drive (VFD) shall be of a modern proven design, fully digital, PLC/Microprocessor based, energy efficient, and shall provide very high reliability, high power factor, low harmonic distortion and low vibration and wear and noise, VFDs shall comply with the latest edition of IEEE 519 & IEC 61000 for both individual as well as total harmonic voltage and current distortion limits, VFD shall be capable of withstanding the thermal and dynamic stresses and the transient mechanical torque, resulting from short circuit. Any damage resulting from such a short circuit or internal fault shall be limited to the component concerned, VFD System shall maintain a power factor of 0.95 (minimum), Overall efficiency shall be minimum 96.5% for VFD, suitable for the LT motor offered for operation in AC three Phase 50Hz (+/- 5%), 440V(+/-10%) suitable to SCADA operation with RS485 port of Rating capacity 75 HP / 55 KW |
| 143 | CE/UL Certified level transmitter for Intake Well :- SITC of CE/UL cirtified of Radar level transmitter CE marked with following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4\\" LED Range- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 |
| 144 | CE/UL Certified Pressure transmitter for pumps & common header :- SITC of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4\\" LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 |
| 145 | SITC of Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required according to latest IS:3043 Supplying and laying 50 mm X 6 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 146 | SITC of 3Ton capacity hand operated over head Travelling (HOT) crane suitable for a span upto 6 Mtrs, and travel length upto 10 Mtrs. with clear lift upto 6 M including gear type chain pulley block and geared Travelling trolley complete with all accessories including girder |
| 147 | Supply &fixing of Rubber mats for electrical purpose as per IS:5424- 1969, plain/chequered (1mX2m) - 10mm thickness |
| 148 | Cable trench Chequerred plate |
| 149 | SITC of Fire fighting equipments 4.5 Kg such as four nos. fire extinguishers ABC type, one set sand bucket with stand and grouting at site and one set Al strong plate and board. |
| 150 | Internal & External electrification of pumping station :- |
| 151 | Indoor Lighting |
| 152 | Surface Mounting |
| 153 | Providing & Fixing of IP40 LED Surface/ Recessed / suspended mounting Mid power SMD type LED Light fixture made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non - yellowish diffuser for uniform light distribution. High efficiency with 2.5 KV internal/external surge protection BIS certified isolated driver having efficiency > 85%, with Short & Open circuit protection and in compliance to IEC standards (Integral with light fixture). System lumen efficacy of ≥ 120 Im/Watt, THD < 10 % , p. f.≥ 0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K / 16000° / 6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard |
| 154 | Suspended Mounting / Surface Mounting |
| 155 | High Power LED Flood Light 100W |
| 156 | Providing & Fixing of ISO Certified company made BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan as per PWD specification for electrical Works, Conform to all the performance requirements laid down in IS:374-2019 including all amendments, as applicable; & Carry BIS licensing (i.e. ISI marking) or Quality Certification such as ISO - 9001 or above. with down rod up to 30 cm with secondary support safety cable ( steel wire ) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc.) as required. |
| 157 | 1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 ) |
| 158 | Providing & Fixing of Heavy duty capacitor start, copper wind Double ball bearing 900/1400 RPM single phase Exhaust fan as per PWD specification for electrical Works, conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. |
| 159 | 450mm sweep (900/1400 RPM) |
| 160 | Outdoor Lighting |
| 161 | Supply and fixing of all in one solar LED light fixturewith integrated high efficient Monocrystalline panel with Lithium (LiFePO4) Ferro Phosphate Battary wih BIS approved make. Luminaire should be secondary optic lences for better distribution with delivered efficacy of > 100 lumen per watt. Bidder shall have in house R & D Laboratory which is recognised by Ministry of Science & Technology Department , Govt of India/NABL.Bidder shall in house pole and luminaire manufacturing facility.Luminaire can be supplied with hybrid switch along with indicator to understand the source of power ( either from solar or AC supply).All the above should be integrated and should 1 system. ( For MCWR ) |
| 162 | Compact Solar LED Street Light- 90W(MONO) 18V / 12.8V 42Ah /60W |
| 163 | Supply installation tesling & Commissioning of IS0 certiftedcompany made high mast lighting system (as per PLG 07 of ILP UK technical report no 7 of ILE UK /IS:875 Part-1 - 2015//BSEN10025/and IS:2062 )consisting of totally hot dip galvanised by single dipped method high mast, lantern carriage suitable for up to 12 nos luminaries with welded arm (excluding luminares), mast head frame assembly with full cover, including 1 No. LED 15 Watts aviation obstruction lights, double drum type self sustaining winch, integral power tool accesible from door with padlocking arrangement ( winch motor with control circuit) hot dipped galvanised heavy duty pipe lightening finial, S.S. ropes (AISI 316, 7 / 19 costruction), EPR insulated PCP sheathed trailing cable, including outdoor type control panel for auto on / off, reverse / forward motor operation and CC foundation of M - 25 grade complete as required as per IS 456/IS 2911. The mast is constructed from mild steel plates (as per IS 5986 Gr. 510 ) cut and folded to form a polygonal (Octogonal) section, telescopic jointed and welding as per BS 5135 and also provide test certificate for wind tunnel test for High mast fixtures. complete in all respect. |
| 164 | 12.5 Mtr. HM (in 2 Section) |
| 165 | Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, 240 volt, 50Hz, of high power LED lamps . Integrated driver must be potted & has a unique BIS R number shall be high efficiency having efficiency more than 85 % and in compliance to BIS certified and T.C. certificate. The System level Luminaire efficacy >=120 Im/ wt with High Power LEDs is to be used . LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety . Input Frequency 50Hz‡3%, Power Factor >0.95 ,driver Efficiency >85% . THD(I) <10% , driver current <1000mA shown in LM79 report. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector Must be provided, Surge Protection Min >=4KV internal and 10KV external, System life of 30000 Burning hours with 70% of Initial Lumens maintained, color Rendering Index >70 and CCT 5700K + 1355K, Driver current <1000mA shown in LM79 report. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture -shall be IS 10322 Complianced and also provide test Certificate/ report with liable warranty of product/accessories. |
| 166 | High Power LED Flood Light 200W |
| 167 | Complete wiring of Pump house, HT & LT room with 1.5 sqmm and 2.5 sqmm with multistarned copper conductor 1.1 KV with required 6A,16A switches,sockets,MCCB etc. |
| 168 | 200 KVA SUB STATION AT INTAKE WELL |
| 169 | Supplying of indoor type floor mounted metal clad, 11 KV VCB panel with 1No. VCBs, totally enclosed & fully interlocked, horizontal drawout, horizontal/ vertical isolation type breaker as per IS 13118, as amended up to date and additional specifications, having capacities as mentioned below, single break, trip free mechanism, manually charged and auto/manually closing breaker suitable for use on 11 KV, 3 Phase, 50 Hz A.C. supply with short circuit fault level of 100 KVa, complete with self contained, fully interlocked, rack in and rack out mechanism, air insulated but encapsulated copper bus bars of 1600Amps capacity, breaker featured with mechanical ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 4 NO+4NC and equipped with following switchgears and accessories i/c connections suitable for 11 KV cable (cable entry from *bottom/ top/side) end termination with heat shrinkable jointing material etc. as required. (Note- Cost of end termination not included in this item)(a) Incoming – ½* No 800Amp. VCB(b) 1* No. – 11 KV / 110 Volts PT Class 0.5 accuracy and 100 VA burder with 1 No. Voltmeter (0-15KV), analog/digital* type, selector switch for voltmeter and protection fuses/MCB for HT metering upto 12 KV on incomer.(c) 1* No. – (0-100 A) dual scale Ammeter, analog/digital* type, selector switches for ammeters.(d) 1* No. – Microprocessor based numerical relay with O/L, E/F and S/C protection.(e) 1* No. – Set of dual core dual ratio 3 CTs 300/150/5/5 A of 15 VA burden and accuracy Class – 0.5 for metering and class 5P10 for protection.(a) Outgoing – 2Nos. 800Amp. VCB(b) 2Nos. – (0-100 A) Ammeters, dual scale analog/digital* type & selector switches for Ammeters.(c) 2 Nos. – Microprocessor based numerical relays with O/L, E/F & S/C protections.(d) 2 Nos. – Set of dual core dual ratio 3 CTs 100/ 50/5/5 A of 15 VA burden and accuracy Class-1.0 for metering and class 5P10 for protection.1. Supply of power pack 24 volts complete with battery and charging device. |
| 170 | Supply of 50 Sq.mm size XLPE cable from 11 K.V.UPPCL metering panel to 11 KV incoming H.T. switch gear panel and panel to transformer. |
| 171 | Supplying of 200 KVA, 11/0.415 KV, 3 Phase, 50 Hz, Dyn 11, indoor ONAN type, copper wound transformer with OFF load tap changing arrangement on HV side in steps of +/- 2.5% & -7.5%, having cable end boxes on HV side suitable for 3x150sqmm XLPE cable of 33 KV grade and bus trunking arrangement on LV side complete with all accessories i/c first filling of filtered dehydrated oil and confirming to IS 1180 & as per specification attached complete in all respects as required at site. |
| 172 | Supplying of cubicall type LT/ MCC panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system fabricated in compartmentalized (preferably) design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having 630Amp capacity extensible type TPN aluminium alloy bus bars of hight conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with 50sq. mm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears :-(I) Incoming : 2 Nos 400 Amps 4 Pole MCCB Microprocessor based of fault breaking capacity 50 KA (Ics=Icu upto 433 V manually operated, fitted with interlocked door, automatic safety shutters, mechanical ON/ OFF and service/test/isolated position indicators and frame earthing contact, conforming to IS 1397- 2 : 1993 as amended up-to-date complete with following accessories for each MCCB.(a) Independent manual spring closing mechanism- 1 No.B10(b) Microprocessor release (EMI & EMC certified) for over current, earth fault & short circuit protection- 1 set.(c) Analog 96 mm square flush pattern / Digital* type Voltmeter (0-500 V), with selector switch & back up HRC fuses/ MCBs-1 set.(d) Analog 96 mm. square flush pattern/ Digital* type Ammeter (0-630Amp), with selector switch and one set of 3 nos. CT’s of ratio10/5A Class I accuracy and 15 VA burden- 1set. (e) 3 Nos. Phase indication LED lamps with 2 Amp back up HRC fuse, breaker ‘ON’ indicating light with 2 A HRC fuse, test terminal block set, fuses, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required.(f) Shunt trip coil 220 V A.C.(II) Bus Couplers :1Nos. 400 Amps MCCB microprocessor based of fault breaking capacity 50 KA (Ics=Icu upto 433 V) manually operated, with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact conforming to IS 13947- 2 : 1993 as amended upto date complete with following accessories for each ACB:(a) Independent manual spring closing mechanism- 1 No.(b) Breaker ‘ON’ indicating light with back up 2 A HRC fuse test terminal block, fuses, circuits contactors for positive electrical interlocking of breakers, etc. as required- 1 set.(III) Bus Bars :TPN aluminium bus bars of minimum of 630Amps capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bar cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 Sec. |
| 173 | (IV) Interlocking :Electrical through advance contacts in MCCB (incomers & bus couplers) and mech- anical (castel key) interlocking should beprovided to ensure that only one supply is available at a time on each section of bus and to eliminate any possiblility of accidentally approaching two supplies at one bus section.(V) Outgoing :-(A) 1 Nos. 400Amp 4 Pole MCCB Microprocessor based of fault breaking capacity 50 KA (Ics=Icu upto 433 V) manually operated, with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact conforming to IS 13947- 2 : 1993 (B) 3 Nos. 160Amp 4 Pole MCCB Microprocessor based of fault breaking capacity 50 KA (Ics=Icu upto 433 V) manually operated, with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact conforming to IS 13947- 2 : 1993 (C) 2 Nos.32Amp 4 Pole MCCB Microprocessor based of fault breaking capacity 50 KA (Ics=Icu upto 433 V) manually operated, with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact conforming to IS 13947- 2 : 1993 |
| 174 | Supply of microprocessor based three phase sensing power factor correction relay panel , IEC / EN 61000-6- (2&4) having 3 CT sensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall have digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, communication interface with RS 485, indication ofswitching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like KW, KVA, KVAR rating capacity of 64 KVAR |
| 175 | Supply of Auto Phase reversal unit with inbuilt time delay & enclosure ( confirm to IEC:60947-1 & IEC:60947-b-1) |
| 176 | 400Amp Rating |
| 177 | Supply and laying of 650/1100 volt grade 150sq mm 3½ core PVC Armoured Aluminium cable from transformer to L.T / MCC Panel (2x3½x150 sq mm) |
| 178 | Making Earth pit for earthing complete in all respect. Earthing system shall executed as per IS:3043 and I.E. rules. |
| 179 | Installation and commissioning of 11 KV/0.4 KV substations including HT Panels and L.T. main control panel including all labor T&P complete in all respect. |
| 180 | Supply and making of indoor cable end termination joint kit of size 70 sq mm 3 core for 11 KV H.T. XLPE cable |
| 181 | Supply and making of outdoor cable end termination joint kit of size 240 sq mm 3 core for 11 KV H.T. XLPE cable |
| 182 | Provision for routine testing of equipments such as transformer, HT Panels and main LT Panel at manufacturer’s works. |
| 183 | NOC from Electrical safety department for all field installations such as pumping plants, substation etc. |
| 184 | PUMPING PLANT AND ACCESSORIES FROM MCWR TO CPT |
| 185 | SITC of Vertical type self-water lubricated statically, dynamically, hydraulically balanced turbine pump capable of discharging at the following duty condition as given below due to all causes with surface discharge head confirming to IS:1710 and as amended as on date with accessories as per IS 5120/1977(Reconfirmed 2011) and as amended thereafter to suit the site condition.The Pump Bowl assembly and casing shall be CI IS 210 FG: 260 with suitable coating inside casing of 500 DFT, suitable for protection against corroision,erosion and prevent oxidation.Impeller and Wearing / Neckring shall be Duplex stainless steel CD4MCu (Chromium-24.5% minimum,Carbon < 0.04% ) as per ASTM A890 GrlA or DIN 1.4474-EN 10088, Hardness 220-260 BHN,pump shaft-Stainless steel AISI 410, pumps and line shaft sleeve - stainless steel with ceremic coating 700 BHN,Strainer-SS 304,coupling between pump ang motor - Flexible pin bush type and bearings shall be Anti friction L-10 with 60000 Hrs life at 1450 rpm. 06 mtr/suitable length column assembly, with vertical Solid shaft Squirrel cage induction motor(IS:126152011/IEC 60034-1) suitable for the above pump continuous rated TEFC IP-55 with Class 'F' insulation for operation in AC, three Phase/50 HZ (±5%), 415V (±10%), running with a speed of pump.Capacity as follows :- |
| 186 | 2500 LPM / 36 Mtr. HEAD / 40 HP MOTOR (2w+1s) |
| 187 | MAIN PIPING :-SITC of 200mm Main piping & valves complete of suitable size and quantity required for delivery side, bye pass arrangement and 250mm common Header upto 1 m. outside the pump house along with 250 x 200 x 250 mm A/F Tee (3 Nos), 250 mm bend (01 Nos), 250 mm blind flange (01 Nos), D/F Pipes suitable size all necessary nuts, bolts, rubber packing, M.S Support for pipe,mechanical joints (04 Nos) etc. complete in all respect as per site conditions. |
| 188 | Motor operated actuator with sluice valve :- SITC of DI/DF sluice valve with Electrically integrated actuater (Totally enclosed, weather-proof and dust proof construction with IP-67, protection class suitable for installation in any position without lubrication, leakage or other operational difficulty with special grease filled gear box and suitable for manual operation for emergency which will automatically dis-engage on restoration of power to motor and with 10 watt single phase space heater and continuous local mechanical position indicator and individually replaceable counter gear assembly and with two torque and four limit switches with S.S. flap and operated with gear driven cams and of rating 250 Volt, 5 Amp, AC/DC, torque switch dial and with TEFC squirrel cage induction) operated suitable to SCADA operation sluice valve having body door cover of graded in cast iron to IS:210 Gr.Fg.260 body and door rings of SS ASTM A743 Gr.CF8 and bearing block of leaded tin bronze to IS:318 Gr.LTB2 hinge pin of stainless steel AISI:431.Valves generally conform to IS:5312.Flanges to be drilled as per IS:1538 Part-IV &VI. Valves are suitable for hydrostatic test pressure of 10Kg./Cm2 for seat and 15Kg./Cm2 for body(PN-1.0) of following sizes |
| 189 | Actuator with Sluice Valve of size :- 200mm for pumps |
| 190 | Actuator with Sluice Valve of size :- 250mm for common header |
| 191 | Non return valve :- SITC of DI/DF Single Door/ Multi Door Non return/reflux valve conforming to IS:5312/2003(part I & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing . |
| 192 | 200 mm Dia for pumps |
| 193 | 250 mm Dia for common header |
| 194 | CE/UL Certified Electromagnetic flow meter :- SITC of CE/UL Full BorecElectromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) , Pressure : up to 1.0 MPa, Process temp:- 50 deg C, Flow/Meter Tube : SS 304, Electrode : SS AISI 316L / Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement ‘of IEC 60529, Accuracy : + 0.5 % M.V. velocity 0.3 to 10 m/s, Transmitter/ signa convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 5OHz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parameters and totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable. |
| 195 | Size 250mm for common header |
| 196 | ELECTRICAL ITEMS:- |
| 197 | Supply & laying of 1.1KV grade XLPE insulated unarmured multi strand copper conductor cable of 3C x 25 sq.mm from control Panel to respective Motors with lugs etc. (copper conductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I / IS :7098 P I) |
| 198 | SITC of Air Cooled Digital soft starter suitable for the LT motor offered for operation in AC three Phase 50Hz (+/- 5%), 415V(+/-10%) including line contactors suitable for next standard higher KW rating, Over & Under load protection, short circuit & single phasing protection with frequency meter, Ammeter, Voltmeter, indicating lamp 6Nos, LED ON/OFF type and Start /Stop push button and Instrument Fuses, suitable to SCADA operation with RS485 Port rating capacity 40 HP / 30 KW |
| 199 | CE/UL Certified level transmitter for MCWR :- SITC of CE/UL cirtified of Radar level transmitter CE marked with following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4\\" LED Range- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 |
| 200 | CE/UL Certified Pressure transmitter for pumps & common header :- SITC of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4\\" LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 |
| 201 | SITC of Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required according to latest IS:3043 Supplying and laying 50mm X 6 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 202 | SITC of 3Ton capacity hand operated over head Travelling (HOT) crane suitable for a span upto 6 Mtrs, and travel length upto 10 Mtrs. with clear lift upto 6 M including gear type chain pulley block and geared Travelling trolley complete with all accessories including girder |
| 203 | Supply &fixing of Rubber mats for electrical purpose as per IS:5424- 1969, plain/chequered (1mX2m) - 10mm thickness |
| 204 | Cable trench Chequerred plate |
| 205 | SITC of Fire fighting equipments 4.5 Kg such as four nos. fire extinguishers ABC type, one set sand bucket with stand and grouting at site and one set Al strong plate and board. |
| 206 | Internal & External electrification of pumping station :- |
| 207 | Indoor Lighting |
| 208 | Surface Mounting |
| 209 | Providing & Fixing of IP40 LED Surface/ Recessed / suspended mounting Mid power SMD type LED Light fixture made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non - yellowish diffuser for uniform light distribution. High efficiency with 2.5 KV internal/external surge protection BIS certified isolated driver having efficiency > 85%, with Short & Open circuit protection and in compliance to IEC standards (Integral with light fixture). System lumen efficacy of ≥ 120 Im/Watt, THD < 10 % , p. f.≥ 0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K / 16000° / 6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard |
| 210 | Suspended Mounting / Surface Mounting |
| 211 | 36W LED light fixture 2'×2' with acrylic / prismatic front cover. |
| 212 | Providing & Fixing of ISO Certified company made BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan as per PWD specification for electrical Works, Conform to all the performance requirements laid down in IS:374-2019 including all amendments, as applicable; & Carry BIS licensing (i.e. ISI marking) or Quality Certification such as ISO - 9001 or above. with down rod up to 30 cm with secondary support safety cable ( steel wire ) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc.) as required. |
| 213 | 1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 ) |
| 214 | Providing & Fixing of Heavy duty capacitor start, copper wind Double ball bearing 900/1400 RPM single phase Exhaust fan as per PWD specification for electrical Works, conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. |
| 215 | 450mm sweep (900/1400 RPM) |
| 216 | Outdoor Lighting |
| 217 | Supply and fixing of all in one solar LED light fixturewith integrated high efficient Monocrystalline panel with Lithium (LiFePO4) Ferro Phosphate Battary wih BIS approved make. Luminaire should be secondary optic lences for better distribution with delivered efficacy of > 100 lumen per watt. Bidder shall have in house R & D Laboratory which is recognised by Ministry of Science & Technology Department , Govt of India/NABL.Bidder shall in house pole and luminaire manufacturing facility.Luminaire can be supplied with hybrid switch along with indicator to understand the source of power ( either from solar or AC supply).All the above should be integrated and should 1 system. ( For MCWR ) |
| 218 | Compact Solar LED Street Light- 60W(MONO) 18V / 12.8V 27Ah /40W |
| 219 | Supply installation tesling & Commissioning of IS0 certiftedcompany made high mast lighting system (as per PLG 07 of ILP UK technical report no 7 of ILE UK /IS:875 Part-1 - 2015//BSEN10025/and IS:2062 )consisting of totally hot dip galvanised by single dipped method high mast, lantern carriage suitable for up to 12 nos luminaries with welded arm (excluding luminares), mast head frame assembly with full cover, including 1 No. LED 15 Watts aviation obstruction lights, double drum type self sustaining winch, integral power tool accesible from door with padlocking arrangement ( winch motor with control circuit) hot dipped galvanised heavy duty pipe lightening finial, S.S. ropes (AISI 316, 7 / 19 costruction), EPR insulated PCP sheathed trailing cable, including outdoor type control panel for auto on / off, reverse / forward motor operation and CC foundation of M - 25 grade complete as required as per IS 456/IS 2911. The mast is constructed from mild steel plates (as per IS 5986 Gr. 510 ) cut and folded to form a polygonal (Octogonal) section, telescopic jointed and welding as per BS 5135 and also provide test certificate for wind tunnel test for High mast fixtures. complete in all respect. |
| 220 | 12.5 Mtr. HM (in 2 Section) |
| 221 | Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, 240 volt, 50Hz, of high power LED lamps .Integrated driver must be potted & has a unique BIS R number shall be high efficiency having efficiency more than 85 % and in compliance to BIS certified and T.C. certificate. The System level Luminaire efficacy >=120 Im/ wt with High Power LEDs is to be used . LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety . Input Frequency 50Hz‡3%, Power Factor >0.95 ,driver Efficiency >85% .THD(I) <10% , driver current <1000mA shown in LM79 report. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector Must be provided, Surge Protection Min >=4KV internal and 10KV external, System life of 30000 Burning hours with 70% of Initial Lumens maintained, color Rendering Index >70 and CCT 5700K + 1355K, Driver current <1000mA shown in LM79 report. Manufactures Word Mark/Name Engraved/Embossing/Screenprinting on die cast housing to allow traceability/authenticity. Fixture-shall be IS 10322 Complianced and also provide test Certificate/ report with liable warranty of product/accessories. |
| 222 | High Power LED Flood Light 200W |
| 223 | Complete wiring of Pump house, HT & LT room with 1.5 sqmm and 2.5 sqmm with multistarned copper conductor 1.1 KV with required 6A,16A switches,sockets,MCCB etc. |
| 224 | 250 KVA SUB STATION AT MCWR ( WTP ) |
| 225 | Supplying of indoor type floor mounted metal clad, 11 KV VCB panel with 1No. VCBs, totally enclosed & fully interlocked, horizontal drawout, horizontal/ vertical isolation type breaker as per IS 13118, as amended up to date and additional specifications, having capacities as mentioned below, single break, trip free mechanism, manually charged and auto/manually closing breaker suitable for use on 11 KV, 3 Phase, 50 Hz A.C. supply with short circuit fault level of 100 KVa, complete with self contained, fully interlocked, rack in and rack out mechanism, air insulated but encapsulated copper bus bars of 1600Amps capacity, breaker featured with mechanical ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 4 NO+4NC and equipped with following switchgears and accessories i/c connections suitable for 11 KV cable (cable entry from *bottom/ top/side) end termination with heat shrinkable jointing material etc. as required. (Note- Cost of end termination not included in this item)(a) Incoming – ½* No 800Amp. VCB(b) 1* No. – 11 KV / 110 Volts PT Class 0.5 accuracy and 100 VA burder with 1 No. Voltmeter (0-15KV), analog/digital* type, selector switch for voltmeter and protection fuses/MCB for HT metering upto 12 KV on incomer.(c) 1* No. – (0-100 A) dual scale Ammeter, analog/digital* type, selector switches for ammeters.(d) 1* No. – Microprocessor based numerical relay with O/L, E/F and S/C protection.(e) 1* No. – Set of dual core dual ratio 3 CTs 300/150/5/5 A of 15 VA burden and accuracy Class – 0.5 for metering and class 5P10 for protection.(a) Outgoing – 2Nos. 800Amp. VCB(b) 2Nos. – (0-100 A) Ammeters, dual scale analog/digital* type & selector switches for Ammeters.(c) 2 Nos. – Microprocessor based numerical relays with O/L, E/F & S/C protections.(d) 2 Nos. – Set of dual core dual ratio 3 CTs 100/ 50/5/5 A of 15 VA burden and accuracy Class-1.0 for metering and class 5P10 for protection.1. Supply of power pack 24 volts complete with battery and charging device. |
| 226 | Supply of 70 Sq.mm size XLPE cable from 11 K.V.UPPCL metering panel to 11 KV incoming H.T. switch gear panel and panel to transformer. |
| 227 | Supplying of 250 KVA, 11/0.415 KV, 3 Phase, 50 Hz, Dyn 11, indoor ONAN type, copper wound transformer with OFF load tap changing arrangement on HV side in steps of +/- 2.5% & -7.5%, having cable end boxes on HV side suitable for 3x70sqmm XLPE cable of 11 KV grade and bus trunking arrangement on LV side complete with all accessories i/c first filling of filtered dehydrated oil and confirming to IS 1180 & as per specification attached complete in all respects as required at site. |
| 228 | Supplying of cubicall type LT / MCC panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system fabricated in compartmentalized (preferably) design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having 630Amp capacity extensible type TPN aluminium alloy bus bars of hight conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with 50sq. mm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears :-(I) Incoming : 2 Nos 500 Amps 4 Pole horizontal drawout type air circuit breaker of fault breaking capacity 50 KA (Ics=Icu upto 433 V manually operated, fitted with interlocked door, automatic safety shutters, mechanical ON/ OFF and service/test/isolated position indicators and frame earthing contact, conforming to IS 1397- 2 : 1993 as amended up-to-date complete with following accessories for each MCCB.(a) Independent manual spring closing mechanism- 1 No.B10(b) Microprocessor release (EMI & EMC certified) for over current, earth fault & short circuit protection- 1 set.(c) Analog 96 mm square flush pattern / Digital* type Voltmeter (0-500 V), with selector switch & back up HRC fuses/ MCBs-1 set.(d) Analog 96 mm. square flush pattern/ Digital* type Ammeter (0-630Amp), with selector switch and one set of 3 nos. CT’s of ratio10/5A Class I accuracy and 15 VA burden- 1set. (e) 3 Nos. Phase indication LED lamps with 2 Amp back up HRC fuse, breaker ‘ON’ indicating light with 2 A HRC fuse, test terminal block set, fuses, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required.(f) Shunt trip coil 220 V A.C.(II) Bus Couplers :1Nos. 630Amps drawout type, air circuit breakers of fault breaking capacity 50 KA (Ics=Icu upto 433 V) manually operated, with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact conforming to IS 13947- 2 : 1993 as amended upto date complete with following accessories for each |
| 229 | ACB:(a) Independent manual spring closing mechanism- 1 No.(b) Breaker ‘ON’ indicating light with back up 2 A HRC fuse test terminal block, fuses, circuits contactors for positive electrical interlocking of breakers, etc. as required- 1 set.(III) Bus Bars :TPN aluminium bus bars of minimum of 630Amps capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bar cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 Sec.(IV) Interlocking :Electrical through advance contacts in ACB’s (incomers & bus couplers) and mech- anical (castel key) interlocking should beprovided to ensure that only one supply is available at a time on each section of bus and to eliminate any possiblility of accidentally approaching two supplies at one bus section.(V) Outgoing :-(A) 1 Nos. 320Amp 4 Pole MCCB of fault breaking capacity 50 KA (Ics=Icu upto 433 V) manually operated, with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact conforming to IS 13947- 2 : 1993 (B) 3 Nos. 80Amp 4 Pole MCCB of fault breaking capacity 50 KA (Ics=Icu upto 433 V) manually operated, with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact conforming to IS 13947- 2 : 1993 (C) 2 Nos. 32Amp 4 Pole MCCB of fault breaking capacity 50 KA (Ics=Icu upto 433 V) manually operated, with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact conforming to IS 13947- 2 : 1993 |
| 230 | (IV) Interlocking :Electrical through advance contacts in ACB’s (incomers & bus couplers) and mech- anical (castel key) interlocking should beprovided to ensure that only one supply is available at a time on each section of bus and to eliminate any possiblility of accidentally approaching two supplies at one bus section.(V) Outgoing :-(A) 1 Nos. 320Amp 4 Pole drawout type, air circuit breakers of fault breaking capacity 50 KA (Ics=Icu upto 433 V) manually operated, with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact conforming to IS 13947- 2 : 1993 (B) 3 Nos. 80Amp 4 Pole drawout type, air circuit breakers of fault breaking capacity 50 KA (Ics=Icu upto 433 V) manually operated, with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact conforming to IS 13947- 2 : 1993 (C) 2 Nos. 32Amp 4 Pole drawout type, air circuit breakers of fault breaking capacity 50 KA (Ics=Icu upto 433 V) manually operated, with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact conforming to IS 13947- 2 : 1993 |
| 231 | Supply of microprocessor based three phase sensing power factor correction relay panel , IEC / EN 61000-6- (2&4) having 3 CT sensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall have digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, communication interface with RS 485, indication ofswitching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like KW, KVA, KVAR rating capacity of 80 KVAR |
| 232 | Supply of Auto Phase reversal unit with inbuilt time delay & enclosure ( confirm to IEC:60947-1 & IEC:60947-b-1) |
| 233 | 320Amp Rating |
| 234 | Supply and laying of 650/1100 volt grade 185sq mm 3½ core PVC Armoured Aluminium cable from transformer to L.T / MCC panel (2x3½x185 sq mm) |
| 235 | Making Earth pit for earthing complete in all respect. Earthing system shall executed as per IS:3043 and I.E. rules. |
| 236 | Installation and commissioning of 11 KV/0.4 KV substations including HT Panels and L.T. main control panel including all labor T&P complete in all respect. |
| 237 | Supply and making of indoor cable end termination joint kit of size 70 sq mm 3 core for 11 KV H.T. XLPE cable |
| 238 | Supply and making of outdoor cable end termination joint kit of size 240 sq mm 3 core for 11 KV H.T. XLPE cable |
| 239 | Provision for routine testing of equipments such as transformer, HT Panels and main LT Panel at manufacturer’s works. |
| 240 | NOC from Electrical safety department for all field installations such as pumping plants, substation etc. |
| 241 | PUMPING PLANT AND ACCESSORIES FOR CCWR TO CWR ( ON HILL ) ZONE-1 |
| 242 | SITC of Vertical type self-water lubricated statically, dynamically, hydraulically balanced turbine pump capable of discharging at the following duty condition as given below due to all causes with surface discharge head confirming to IS:1710 and as amended as on date with accessories as per IS 5120/1977(Reconfirmed 2011) and as amended thereafter to suit the site condition.The Pump Bowl assembly and casing shall be CI IS 210 FG: 260 with suitable coating inside casing of 500 DFT, suitable for protection against corroision,erosion and prevent oxidation.Impeller and Wearing / Neckring shall be Duplex stainless steel CD4MCu (Chromium-24.5% minimum,Carbon < 0.04% ) as per ASTM A890 GrlA or DIN 1.4474-EN 10088, Hardness 220- 260 BHN,pump shaft-Stainless steel AISI 410, pumps and line shaft sleeve - stainless steel with ceremic coating 700 BHN,Strainer-SS 304,coupling between pump ang motor - Flexible pin bush type and bearings shall be Anti friction L-10 with 60000 Hrs life at 1450 rpm. 06 mtr/suitable length column assembly, with vertical Solid shaft Squirrel cage induction motor(IS:126152011/IEC 60034-1) suitable for the above pump continuous rated TEFC IP-55 with Class 'F' insulation for operation in AC, three Phase/50 HZ (±5%), 415V (±10%), running with a speed of pump.Capacity as follows :-850 LPM / 37 Mtr. HEAD / 15 HP MOTOR (1w+1s) |
| 243 | MAIN PIPING :-SITC of 100mm Main piping & valves complete of suitable size and quantity required for delivery side, bye pass arrangement and 100mm common Header upto 1 m. outside the pump house along with 100 x 100 x 100 mm A/F Tee (3Nos), 100 mm bend (01 Nos), 100 mm blind flange (01 Nos), D/F Pipes suitable size all necessary nuts, bolts, rubber packing, M.S Support for pipe,mechanical joints (03 Nos) etc. complete in all respect as per site conditions. |
| 244 | Motor operated actuator with sluice valve :- SITC of DI/DF sluice valve with Electrically integrated actuater (Totally enclosed, weather-proof and dust proof construction with IP- 67, protection class suitable for installation in any position without lubrication, leakage or other operational difficulty with special grease filled gear box and suitable for manual operation for emergency which will automatically dis-engage on restoration of power to motor and with 10 watt single phase space heater and continuous local mechanical position indicator and individually replaceable counter gear assembly and with two torque and four limit switches withS. S. flap and operated with gear driven cams and of rating 250 Volt, 5 Amp, AC/DC, torque switch dial and with TEFC squirrel cage induction) operated suitable to SCADA operation sluice valve having body door cover of graded in cast iron to IS:210 Gr.Fg.260 body and door rings of SS ASTM A743 Gr.CF8 and bearing block of leaded tin bronze to IS:318 Gr.LTB2 hinge pin of stainless steel AISI:431.Valves generally conform to IS:5312.Flanges to be drilled as per IS:1538 Part-IV &VI. Valves are suitable for hydrostatic test pressure of 10Kg./Cm2 for seat and 15Kg./Cm2 for body(PN-1.0) of following sizes |
| 245 | Actuator with Sluice Valve of size :- 100mm for pumps |
| 246 | Actuator with Sluice Valve of size :- 100mm for common header |
| 247 | Non return valve :- SITC of DI/DF Single Door/ Multi Door Non return/reflux valve conforming to IS:5312/2003(part I & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing . |
| 248 | 100 mm Dia for pumps |
| 249 | 100 mm Dia for common header |
| 250 | CE/UL Certified Electromagnetic flow meter :- SITC of CE/UL Full BorecElectromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) , Pressure : up to 1.0 MPa, Process temp:- 50 deg C, Flow/Meter Tube : SS 304, Electrode : SS AISI 316L / Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement ‘of IEC 60529, Accuracy : + 0.5 % M.V. velocity 0.3 to 10 m/s, Transmitter/ signa convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 5OHz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parameters and totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable. |
| 251 | Size 100mm for common header |
| 252 | ELECTRICAL ITEMS:- |
| 253 | Supply & laying of 1.1KV grade XLPE insulated unarmured multi strand copper conductor cable of 3C x 10 sq.mm from control Panel to respective Motors with lugs etc. (copper conductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I / IS :7098 P I) |
| 254 | SITC of Air Cooled Digital soft starter suitable for the LT motor offered for operation in AC three Phase 50Hz (+/- 5%), 415V(+/-10%) including line contactors suitable for next standard higher KW rating, Over & Under load protection, short circuit & single phasing protection with frequency meter, Ammeter, Voltmeter, indicating lamp 6Nos, LED ON/OFF type and Start /Stop push button and Instrument Fuses, suitable to SCADA operation with RS485 Port rating capacity 15 HP / 11 KW |
| 255 | CE/UL Certified level transmitter for CCWR :- SITC of CE/UL cirtified of Radar level transmitter CE marked with following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4\\" LED Range- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 |
| 256 | CE/UL Certified Pressure transmitter for pumps & common header :- SITC of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4\\" LED Accuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 |
| 257 | SITC of Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required according to latest IS:3043 Supplying and laying 50 mm X 6 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 258 | SITC of 3Ton capacity hand operated over head Travelling (HOT) crane suitable for a span upto 6 Mtrs, and travel length upto 10 Mtrs. with clear lift upto 6 M including gear type chain pulley block and geared Travelling trolley complete with all accessories including girder |
| 259 | Supply &fixing of Rubber mats for electrical purpose as per IS:5424- 1969, plain/chequered (1mX2m) - 10mm thickness |
| 260 | Cable trench Chequerred plate |
| 261 | SITC of Fire fighting equipments 4.5 Kg such as four nos. fire extinguishers ABC type, one set sand bucket with stand and grouting at site and one set Al strong plate and board. |
| 262 | Internal & External electrification of pumping station :- |
| 263 | Indoor Lighting |
| 264 | Surface Mounting |
| 265 | Providing & Fixing of IP40 LED Surface/ Recessed / suspended mounting Mid power SMD type LED Light fixture made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non - yellowish diffuser for uniform light distribution. High efficiency with 2.5 KV internal/external surge protection BIS certified isolated driver having efficiency > 85%, with Short & Open circuit protection and in compliance to IEC standards (Integral with light fixture). System lumen efficacy of ≥ 120 Im/Watt, THD < 10 % , p. f.≥ 0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K / 16000° / 6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard |
| 266 | Suspended Mounting / Surface Mounting |
| 267 | High Power LED Flood Light 100W |
| 268 | Providing & Fixing of ISO Certified company made BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan as per PWD specification for electrical Works, Conform to all the performance requirements laid down in IS:374-2019 including all amendments, as applicable; & Carry BIS licensing (i.e. ISI marking) or Quality Certification such as ISO - 9001 or above. with down rod up to 30 cm with secondary support safety cable ( steel wire ) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc.) as required. |
| 269 | 1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 ) |
| 270 | Providing & Fixing of Heavy duty capacitor start, copper wind Double ball bearing 900/1400 RPM single phase Exhaust fan as per PWD specification for electrical Works, conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. |
| 271 | 450mm sweep (900/1400 RPM) |
| 272 | Outdoor Lighting |
| 273 | Supply and fixing of all in one solar LED light fixturewith integrated high efficient Monocrystalline panel with Lithium (LiFePO4) Ferro Phosphate Battary wih BIS approved make. Luminaire should be secondary optic lences for better distribution with delivered efficacy of > 100 lumen per watt. Bidder shall have in house R & D Laboratory which is recognised by Ministry of Science & Technology Department , Govt of India/NABL.Bidder shall in house pole and luminaire manufacturing facility.Luminaire can be supplied with hybrid switch along with indicator to understand the source of power ( either from solar or AC supply).All the above should be integrated and should 1 system. ( For MCWR ) |
| 274 | Compact Solar LED Street Light- 90W(MONO) 18V / 12.8V 42Ah /60W |
| 275 | Supply installation tesling & Commissioning of IS0 certiftedcompany made high mast lighting system (as per PLG 07 of ILP UK technical report no 7 of ILE UK /IS:875 Part-1 - 2015//BSEN10025/and IS:2062 )consisting of totally hot dip galvanised by single dipped method high mast, lantern carriage suitable for up to 12 nos luminaries with welded arm (excluding luminares), mast head frame assembly with full cover, including 1 No. LED 15 Watts aviation obstruction lights, double drum type self sustaining winch, integral power tool accesible from door with padlocking arrangement ( winch motor with control circuit) hot dipped galvanised heavy duty pipe lightening finial, S.S. ropes (AISI 316, 7 / 19 costruction), EPR insulated PCP sheathed trailing cable, including outdoor type control panel for auto on / off, reverse / forward motor operation and CC foundation of M - 25 grade complete as required as per IS 456/IS 2911. The mast is constructed from mild steel plates (as per IS 5986 Gr. 510 ) cut and folded to form a polygonal (Octogonal) section, telescopic jointed and welding as per BS 5135 and also provide test certificate for wind tunnel test for High mast fixtures. complete in all respect. |
| 276 | 12.5 Mtr. HM (in 2 Section) |
| 277 | Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, 240 volt, 50Hz, of high power LED lamps . Integrated driver must be potted & has a unique BIS R number shall be high efficiency having efficiency more than 85 % and in compliance to BIS certified and T.C. certificate. The System level Luminaire efficacy >=120 Im/ wt with High Power LEDs is to be used . LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety . Input Frequency 50Hz‡3%, Power Factor >0.95 ,driver Efficiency >85% . THD(I) <10% , driver current <1000mA shown in LM79 report. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector Must be provided, Surge Protection Min >=4KV internal and 10KV external, System life of 30000 Burning hours with 70% of Initial Lumens maintained, color Rendering Index >70 and CCT 5700K + 1355K, Driver current <1000mA shown in LM79 report. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture -shall be IS 10322 Complianced and also provide test Certificate/ report with liable warranty of product/accessories. |
| 278 | High Power LED Flood Light 200W |
| 279 | Complete wiring of Pump house, HT & LT room with 1.5 sqmm and 2.5 sqmm with multistarned copper conductor 1.1 KV with required 6A,16A switches,sockets,MCCB etc. |
| 280 | 100 KVA SUB STATION AT CCWR |
| 281 | Supplying of indoor type floor mounted metal clad, 11 KV VCB panel with 1No. VCBs, totally enclosed & fully interlocked, horizontal drawout, horizontal/ vertical isolation type breaker as per IS 13118, as amended up to date and additional specifications, having capacities as mentioned below, single break, trip free mechanism, manually charged and auto/manually closing breaker suitable for use on 11 KV, 3 Phase, 50 Hz A.C. supply with short circuit fault level of 100 KVa, complete with self contained, fully interlocked, rack in and rack out mechanism, air insulated but encapsulated copper bus bars of 1600Amps capacity, breaker featured with mechanical ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 4 NO+4NC and equipped with following switchgears and accessories i/c connections suitable for 11 KV cable (cable entry from *bottom/ top/side) end termination with heat shrinkable jointing material etc. as required. (Note- Cost of end termination not included in this item)(a) Incoming – ½* No 800Amp. VCB(b) 1* No. – 11 KV / 110 Volts PT Class 0.5 accuracy and 100 VA burder with 1 No. Voltmeter (0-15KV), analog/digital* type, selector switch for voltmeter and protection fuses/MCB for HT metering upto 12 KV on incomer.(c) 1* No. – (0-100 A) dual scale Ammeter, analog/digital* type, selector switches for ammeters.(d) 1* No. – Microprocessor based numerical relay with O/L, E/F and S/C protection.(e) 1* No. – Set of dual core dual ratio 3 CTs 300/150/5/5 A of 15 VA burden and accuracy Class – 0.5 for metering and class 5P10 for protection.(a) Outgoing – 2Nos. 800Amp. VCB(b) 2Nos. – (0-100 A) Ammeters, dual scale analog/digital* type & selector switches for Ammeters.(c) 2 Nos. – Microprocessor based numerical relays with O/L, E/F & S/C protections.(d) 2 Nos. – Set of dual core dual ratio 3 CTs 100/ 50/5/5 A of 15 VA burden and accuracy Class-1.0 for metering and class 5P10 for protection.1. Supply of power pack 24 volts complete with battery and charging device. |
| 282 | Supply of 50 Sq.mm size XLPE cable from 11 K.V.UPPCL metering panel to 11 KV incoming H.T. switch gear panel and panel to transformer. |
| 283 | Supplying of 100 KVA, 11/0.415 KV, 3 Phase, 50 Hz, Dyn 11, indoor ONAN type, copper wound transformer with OFF load tap changing arrangement on HV side in steps of +/- 2.5% & -7.5%, having cable end boxes on HV side suitable for 3x150sqmm XLPE cable of 33 KV grade and bus trunking arrangement on LV side complete with all accessories i/c first filling of filtered dehydrated oil and confirming to IS 1180 & as per specification attached complete in all respects as required at site. |
| 284 | Supplying of cubicall type LT / MCC panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system fabricated in compartmentalized (preferably) design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having 630Amp capacity extensible type TPN aluminium alloy bus bars of hight conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with 50sq. mm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears :-(I) Incoming : 2 Nos 200 Amps 4 Pole MCCB of fault breaking capacity 50 KA (Ics=Icu upto 433 V manually operated, fitted with interlocked door, automatic safety shutters, mechanical ON/ OFF and service/test/isolated position indicators and frame earthing contact, conforming to IS 1397- 2 : 1993 as amended up-to-date complete with following accessories for each MCCB.(a) Independent manual spring closing mechanism- 1 No.B10(b) Microprocessor release (EMI & EMC certified) for over current, earth fault & short circuit protection- 1 set. |
| 285 | (c) Analog 96 mm square flush pattern / Digital* type Voltmeter (0-500 V), with selector switch & back up HRC fuses/ MCBs-1 set.(d) Analog 96 mm. square flush pattern/ Digital* type Ammeter (0-630Amp), with selector switch and one set of 3 nos. CT’s of ratio10/5A Class I accuracy and 15 VA burden- 1set. (e) 3 Nos. Phase indication LED lamps with 2 Amp back up HRC fuse, breaker ‘ON’ indicating light with 2 A HRC fuse, test terminal block set, fuses, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required.(f) Shunt trip coil 220 V A.C.(II) Bus Couplers :1Nos. 200 Amps MCCB of fault breaking capacity 50 KA (Ics=Icu upto 433 V) manually operated, with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact conforming to IS 13947- 2 : 1993 as amended upto date complete with following accessories for each ACB:(a) Independent manual spring closing mechanism- 1 No.(b) Breaker ‘ON’ indicating light with back up 2 A HRC fuse test terminal block, fuses, circuits contactors for positive electrical interlocking of breakers, etc. as required- 1 set.(III) Bus Bars :TPN aluminium bus bars of minimum of 630Amps capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bar cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 Sec.(IV) Interlocking :Electrical through advance contacts in MCCB (incomers & bus couplers) and mech- anical (castel key) interlocking should beprovided to ensure that only one supply is available at a time on each section of bus and to eliminate any possiblility of accidentally approaching two supplies at one bus section.(V) Outgoing :-(A) 1 Nos. 200 Amp 4 Pole MCCB of fault breaking capacity 50 KA (Ics=Icu upto 433 V) manually operated, with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact conforming to IS 13947- 2 : 1993 (B) 2 Nos. 80 Amp 4 Pole MCCB of fault breaking capacity 50 KA (Ics=Icu upto 433 V) manually operated, with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact conforming to IS 13947- 2 : 1993 (C) 2 Nos. 50 Amp , ( D ) 2 Nos. 32 Amp 4 Pole MCCB of fault breaking capacity 50 KA (Ics=Icu upto 433 V) manually operated, with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact conforming to IS 13947- 2 : 1993 |
| 286 | (IV) Interlocking :Electrical through advance contacts in ACB’s (incomers & bus couplers) and mech- anical (castel key) interlocking should beprovided to ensure that only one supply is available at a time on each section of bus and to eliminate any possiblility of accidentally approaching two supplies at one bus section.(V) Outgoing :-(A) 1 Nos. 200Amp 4 Pole drawout type, air circuit breakers of fault breaking capacity 50 KA (Ics=Icu upto 433 V) manually operated, with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact conforming to IS 13947- 2 : 1993 (B) 2 Nos. 80Amp 4 Pole drawout type, air circuit breakers of fault breaking capacity 50 KA (Ics=Icu upto 433 V) manually operated, with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact conforming to IS 13947- 2 : 1993 (C) 2 Nos. 50Amp , ( D ) 2 Nos. 32 Amp 4 Pole drawout type, air circuit breakers of fault breaking capacity 50 KA (Ics=Icu upto 433 V) manually operated, with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact conforming to IS 13947- 2 : 1993 SITC of microprocessor based three phase sensing power factor correction relay panel , IEC / EN 61000-6- (2&4) having 3 CT sensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall have digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, communication interface with RS 485, indication ofswitching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like KW, KVA, KVAR rating capacity of 31 KVAR |
| 287 | SITC of Auto Phase reversal unit with inbuilt time delay & enclosure ( confirm to IEC:60947-1 & IEC:60947-b-1) |
| 288 | 200Amp Rating |
| 289 | Supply and laying of 650/1100 volt grade 240sq mm 3½ core PVC Armoured Aluminium cable from transformer to L.T / MCC panel (1x3½x240 sq mm) |
| 290 | Making Earth pit for earthing complete in all respect. Earthing system shall executed as per IS:3043 and I.E. rules. |
| 291 | Installation and commissioning of 11 KV/0.4 KV substations including HT Panels and L.T. main control panel including all labor T&P complete in all respect. |
| 292 | Supply and making of indoor cable end termination joint kit of size 70 sq mm 3 core for 11 KV H.T. XLPE cable |
| 293 | Supply and making of outdoor cable end termination joint kit of size 240 sq mm 3 core for 11 KV H.T. XLPE cable |
| 294 | Provision for routine testing of equipments such as transformer, HT Panels and main LT Panel at manufacturer’s works. |
| 295 | NOC from Electrical safety department for all field installations such as pumping plants, substation etc. |
| 296 | PUMPING PLANT AND ACCESSORIES FOR CCWR TO OHT ZONE-2 |
| 297 | SITC of Vertical type self-water lubricated statically, dynamically, hydraulically balanced turbine pump capable of discharging at the following duty condition as given below due to all causes with surface discharge head confirming to IS:1710 and as amended as on date with accessories as per IS 5120/1977(Reconfirmed 2011) and as amended thereafter to suit the site condition.The Pump Bowl assembly and casing shall be CI IS 210 FG: 260 with suitable coating inside casing of 500 DFT, suitable for protection against corroision,erosion and prevent oxidation.Impeller and Wearing / Neckring shall be Duplex stainless steel CD4MCu (Chromium-24.5% minimum,Carbon < 0.04% ) as per ASTM A890 GrlA or DIN 1.4474-EN 10088, Hardness 220- 260 BHN,pump shaft-Stainless steel AISI 410, pumps and line shaft sleeve - stainless steel with ceremic coating 700 BHN,Strainer-SS 304,coupling between pump ang motor - Flexible pin bush type and bearings shall be Anti friction L-10 with 60000 Hrs life at 1450 rpm. 06 mtr/suitable length column assembly, with vertical Solid shaft Squirrel cage induction motor(IS:126152011/IEC 60034-1) suitable for the above pump continuous rated TEFC IP-55 with Class 'F' insulation for operation in AC, three Phase/50 HZ (±5%), 415V (±10%), running with a speed of pump.Capacity as follows :- |
| 298 | 2800 LPM / 38 Mtr. HEAD / 40 HP MOTOR (1w+1s) |
| 299 | MAIN PIPING :-SITC of 200mm Main piping & valves complete of suitable size and quantity required for delivery side, bye pass arrangement and 200mm common Header upto 1 m. outside the pump house along with 200 x 200 x 200 mm A/F Tee (3Nos), 200 mm bend (01 Nos), 200 mm blind flange (01 Nos), D/F Pipes suitable size all necessary nuts, bolts, rubber packing, M.S Support for pipe,mechanical joints (03 Nos) etc. complete in all respect as per site conditions. |
| 300 | Motor operated actuator with sluice valve :- SITC of DI/DF sluice valve with Electrically integrated actuater (Totally enclosed, weather-proof and dust proof construction with IP- 67, protection class suitable for installation in any position without lubrication, leakage or other operational difficulty with special grease filled gear box and suitable for manual operation for emergency which will automatically dis-engage on restoration of power to motor and with 10 watt single phase space heater and continuous local mechanical position indicator and individually replaceable counter gear assembly and with two torque and four limit switches withS. S. flap and operated with gear driven cams and of rating 250 Volt, 5 Amp, AC/DC, torque switch dial and with TEFC squirrel cage induction) operated suitable to SCADA operation sluice valve having body door cover of graded in cast iron to IS:210 Gr.Fg.260 body and door rings of SS ASTM A743 Gr.CF8 and bearing block of leaded tin bronze to IS:318 Gr.LTB2 hinge pin of stainless steel AISI:431.Valves generally conform to IS:5312.Flanges to be drilled as per IS:1538 Part-IV &VI. Valves are suitable for hydrostatic test pressure of 10Kg./Cm2 for seat and 15Kg./Cm2 for body(PN-1.0) of following sizes |
| 301 | Actuator with Sluice Valve of size :- 200mm for pumps |
| 302 | Actuator with Sluice Valve of size :- 200mm for common header |
| 303 | Non return valve :- SITC of DI/DF Single Door/ Multi Door Non return/reflux valve conforming to IS:5312/2003(part I & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing . |
| 304 | 200 mm Dia for pumps |
| 305 | 200 mm Dia for common header |
| 306 | CE/UL Certified Electromagnetic flow meter :- SITC of CE/UL Full BorecElectromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) , Pressure : up to 1.0 MPa, Process temp:- 50 deg C, Flow/Meter Tube : SS 304, Electrode : SS AISI 316L / Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement ‘of IEC 60529, Accuracy : + 0.5 % M.V. velocity 0.3 to 10 m/s, Transmitter/ signa convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 5OHz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parameters and totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable. |
| 307 | Size 200mm for common header |
| 308 | ELECTRICAL ITEMS:- |
| 309 | Supply & laying of 1.1KV grade XLPE insulated unarmured multi strand copper conductor cable of 3C x 25 sq.mm from control Panel to respective Motors with lugs etc. (copper conductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I / IS :7098 P I) |
| 310 | SITC of Air Cooled Digital soft starter suitable for the LT motor offered for operation in AC three Phase 50Hz (+/- 5%), 415V(+/-10%) including line contactors suitable for next standard higher KW rating, Over & Under load protection, short circuit & single phasing protection with frequency meter, Ammeter, Voltmeter, indicating lamp 6Nos, LED ON/OFF type and Start /Stop push button and Instrument Fuses, suitable to SCADA operation with RS485 Port rating capacity 40 HP / 30 KW |
| 311 | CE/UL Certified Pressure transmitter for pumps & common header :- SITC of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4\\" LED Accuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 |
| 312 | SITC of Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required according to latest IS:3043 Supplying and laying 50 mm X 6 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 313 | Supply & fixing of Rubber mats for electrical purpose as per IS:5424-1969, plain/chequered (1mX2m) - 10mm thickness |
| 314 | Cable trench Chequerred plate |
| 315 | PUMPING PLANT AND ACCESSORIES FOR CWR-3 TO OHT-3 |
| 316 | SITC of Vertical type self-water lubricated statically, dynamically, hydraulically balanced turbine pump capable of discharging at the following duty condition as given below due to all causes with surface discharge head confirming to IS:1710 and as amended as on date with accessories as per IS 5120/1977(Reconfirmed 2011) and as amended thereafter to suit the site condition.The Pump Bowl assembly and casing shall be CI IS 210 FG: 260 with suitable coating inside casing of 500 DFT, suitable for protection against corroision,erosion and prevent oxidation.Impeller and Wearing / Neckring shall be Duplex stainless steel CD4MCu (Chromium-24.5% minimum,Carbon < 0.04% ) as per ASTM A890 GrlA or DIN 1.4474-EN 10088, Hardness 220- 260 BHN,pump shaft-Stainless steel AISI 410, pumps and line shaft sleeve - stainless steel with ceremic coating 700 BHN,Strainer-SS 304,coupling between pump ang motor - Flexible pin bush type and bearings shall be Anti friction L-10 with 60000 Hrs life at 1450 rpm. 06 mtr/suitable length column assembly, with vertical Solid shaft Squirrel cage induction motor(IS:126152011/IEC 60034-1) suitable for the above pump continuous rated TEFC IP-55 with Class 'F' insulation for operation in AC, three Phase/50 HZ (±5%), 415V (±10%), running with a speed of pump.Capacity as follows :- |
| 317 | 2950 LPM / 40 Mtr. HEAD / 40 HP MOTOR (1w+1s) |
| 318 | MAIN PIPING :-SITC of 200mm Main piping & valves complete of suitable size and quantity required for delivery side, bye pass arrangement and 200mm common Header upto 1 m. outside the pump house along with 200 x 200 x 200 mm A/F Tee (3Nos), 200 mm bend (01 Nos), 200 mm blind flange (01 Nos), D/F Pipes suitable size all necessary nuts, bolts, rubber packing, M.S Support for pipe,mechanical joints (03 Nos) etc. complete in all respect as per site conditions. |
| 319 | Motor operated actuator with sluice valve :- SITC of DI/DF sluice valve with Electrically integrated actuater (Totally enclosed, weather-proof and dust proof construction with IP- 67, protection class suitable for installation in any position without lubrication, leakage or other operational difficulty with special grease filled gear box and suitable for manual operation for emergency which will automatically dis-engage on restoration of power to motor and with 10 watt single phase space heater and continuous local mechanical position indicator and individually replaceable counter gear assembly and with two torque and four limit switches withS. S. flap and operated with gear driven cams and of rating 250 Volt, 5 Amp, AC/DC, torque switch dial and with TEFC squirrel cage induction) operated suitable to SCADA operation sluice valve having body door cover of graded in cast iron to IS:210 Gr.Fg.260 body and door rings of SS ASTM A743 Gr.CF8 and bearing block of leaded tin bronze to IS:318 Gr.LTB2 hinge pin of stainless steel AISI:431.Valves generally conform to IS:5312.Flanges to be drilled as per IS:1538 Part-IV &VI. Valves are suitable for hydrostatic test pressure of 10Kg./Cm2 for seat and 15Kg./Cm2 for body(PN-1.0) of following sizes |
| 320 | Actuator with Sluice Valve of size :- 200mm for pumps |
| 321 | Actuator with Sluice Valve of size :- 200mm for common header |
| 322 | Non return valve :- SITC of DI/DF Single Door/ Multi Door Non return/reflux valve conforming to IS:5312/2003(part I & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing . |
| 323 | 200 mm Dia for pumps |
| 324 | 200 mm Dia for common header |
| 325 | CE/UL Certified Electromagnetic flow meter :- SITC of CE/UL Full BorecElectromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) , Pressure : up to 1.0 MPa, Process temp:- 50 deg C, Flow/Meter Tube : SS 304, Electrode : SS AISI 316L / Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement ‘of IEC 60529, Accuracy : + 0.5 % M.V. velocity 0.3 to 10 m/s, Transmitter/ signa convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 5OHz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parameters and totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable. |
| 326 | Size 200mm for common header |
| 327 | ELECTRICAL ITEMS:- |
| 328 | Supply & laying of 1.1KV grade XLPE insulated unarmured multi strand copper conductor cable of 3C x 25 sq.mm from control Panel to respective Motors with lugs etc. (copper conductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I / IS :7098 P I) |
| 329 | SITC of Air Cooled Digital soft starter suitable for the LT motor offered for operation in AC three Phase 50Hz (+/- 5%), 415V(+/-10%) including line contactors suitable for next standard higher KW rating, Over & Under load protection, short circuit & single phasing protection with frequency meter, Ammeter, Voltmeter, indicating lamp 6Nos, LED ON/OFF type and Start /Stop push button and Instrument Fuses, suitable to SCADA operation with RS485 Port rating capacity 40 HP / 30 KW |
| 330 | CE/UL Certified level transmitter for CWR :- SITC of CE/UL cirtified of Radar level transmitter CE marked with following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4\\" LED Range- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 |
| 331 | CE/UL Certified Pressure transmitter for pumps & common header :- SITC of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4\\" LED Accuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 |
| 332 | SITC of Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required according to latest IS:3043 Supplying and laying 50 mm X 6 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 333 | SITC of 3Ton capacity hand operated over head Travelling (HOT) crane suitable for a span upto 6 Mtrs, and travel length upto 10 Mtrs. with clear lift upto 6 M including gear type chain pulley block and geared Travelling trolley complete with all accessories including girder |
| 334 | Supply &fixing of Rubber mats for electrical purpose as per IS:5424- 1969, plain/chequered (1mX2m) - 10mm thickness |
| 335 | Cable trench Chequerred plate |
| 336 | SITC of Fire fighting equipments 4.5 Kg such as four nos. fire extinguishers ABC type, one set sand bucket with stand and grouting at site and one set Al strong plate and board. |
| 337 | Internal & External electrification of pumping station :- |
| 338 | Indoor Lighting |
| 339 | Surface Mounting |
| 340 | Providing & Fixing of IP40 LED Surface/ Recessed / suspended mounting Mid power SMD type LED Light fixture made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non - yellowish diffuser for uniform light distribution. High efficiency with 2.5 KV internal/external surge protection BIS certified isolated driver having efficiency > 85%, with Short & Open circuit protection and in compliance to IEC standards (Integral with light fixture). System lumen efficacy of ≥ 120 Im/Watt, THD < 10 % , p. f.≥ 0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K / 16000° / 6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard |
| 341 | Suspended Mounting / Surface Mounting |
| 342 | High Power LED Flood Light 100W |
| 343 | Providing & Fixing of ISO Certified company made BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan as per PWD specification for electrical Works, Conform to all the performance requirements laid down in IS:374-2019 including all amendments, as applicable; & Carry BIS licensing (i.e. ISI marking) or Quality Certification such as ISO - 9001 or above. with down rod up to 30 cm with secondary support safety cable ( steel wire ) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc.) as required. |
| 344 | 1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 ) |
| 345 | Providing & Fixing of Heavy duty capacitor start, copper wind Double ball bearing 900/1400 RPM single phase Exhaust fan as per PWD specification for electrical Works, conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. |
| 346 | 450mm sweep (900/1400 RPM) |
| 347 | Outdoor Lighting |
| 348 | Supply and fixing of all in one solar LED light fixturewith integrated high efficient Monocrystalline panel with Lithium (LiFePO4) Ferro Phosphate Battary wih BIS approved make. Luminaire should be secondary optic lences for better distribution with delivered efficacy of > 100 lumen per watt. Bidder shall have in house R & D Laboratory which is recognised by Ministry of Science & Technology Department , Govt of India/NABL.Bidder shall in house pole and luminaire manufacturing facility.Luminaire can be supplied with hybrid switch along with indicator to understand the source of power ( either from solar or AC supply).All the above should be integrated and should 1 system. ( For MCWR ) |
| 349 | Compact Solar LED Street Light- 90W(MONO) 18V / 12.8V 42Ah /60W |
| 350 | Supply installation tesling & Commissioning of IS0 certiftedcompany made high mast lighting system (as per PLG 07 of ILP UK technical report no 7 of ILE UK /IS:875 Part-1 - 2015//BSEN10025/and IS:2062 )consisting of totally hot dip galvanised by single dipped method high mast, lantern carriage suitable for up to 12 nos luminaries with welded arm (excluding luminares), mast head frame assembly with full cover, including 1 No. LED 15 Watts aviation obstruction lights, double drum type self sustaining winch, integral power tool accesible from door with padlocking arrangement ( winch motor with control circuit) hot dipped galvanised heavy duty pipe lightening finial, S.S. ropes (AISI 316, 7 / 19 costruction), EPR insulated PCP sheathed trailing cable, including outdoor type control panel for auto on / off, reverse / forward motor operation and CC foundation of M - 25 grade complete as required as per IS 456/IS 2911. The mast is constructed from mild steel plates (as per IS 5986 Gr. 510 ) cut and folded to form a polygonal (Octogonal) section, telescopic jointed and welding as per BS 5135 and also provide test certificate for wind tunnel test for High mast fixtures. complete in all respect. |
| 351 | 12.5 Mtr. HM (in 2 Section) |
| 352 | Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, 240 volt, 50Hz, of high power LED lamps . Integrated driver must be potted & has a unique BIS R number shall be high efficiency having efficiency more than 85 % and in compliance to BIS certified and T.C. certificate. The System level Luminaire efficacy >=120 Im/ wt with High Power LEDs is to be used . LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety . Input Frequency 50Hz‡3%, Power Factor >0.95 ,driver Efficiency >85% . THD(I) <10% , driver current <1000mA shown in LM79 report. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector Must be provided, Surge Protection Min >=4KV internal and 10KV external, System life of 30000 Burning hours with 70% of Initial Lumens maintained, color Rendering Index >70 and CCT 5700K + 1355K, Driver current <1000mA shown in LM79 report. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture -shall be IS 10322 Complianced and also provide test Certificate/ report with liable warranty of product/accessories. |
| 353 | High Power LED Flood Light 200W |
| 354 | Complete wiring of Pump house, HT & LT room with 1.5 sqmm and 2.5 sqmm with multistarned copper conductor 1.1 KV with required 6A,16A switches,sockets,MCCB etc. |
| 355 | 100 KVA SUB STATION AT CWR-3 |
| 356 | Supplying of indoor type floor mounted metal clad, 11 KV VCB panel with 1No. VCBs, totally enclosed & fully interlocked, horizontal drawout, horizontal/ vertical isolation type breaker as per IS 13118, as amended up to date and additional specifications, having capacities as mentioned below, single break, trip free mechanism, manually charged and auto/manually closing breaker suitable for use on 11 KV, 3 Phase, 50 Hz A.C. supply with short circuit fault level of 100 KVa, complete with self contained, fully interlocked, rack in and rack out mechanism, air insulated but encapsulated copper bus bars of 1600Amps capacity, breaker featured with mechanical ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 4 NO+4NC and equipped with following switchgears and accessories i/c connections suitable for 11 KV cable (cable entry from *bottom/ top/side) end termination with heat shrinkable jointing material etc. as required. (Note- Cost of end termination not included in this item)(a) Incoming – ½* No 800Amp. VCB(b) 1* No. – 11 KV / 110 Volts PT Class 0.5 accuracy and 100 VA burder with 1 No. Voltmeter (0-15KV), analog/digital* type, selector switch for voltmeter and protection fuses/MCB for HT metering upto 12 KV on incomer. |
| 357 | (c) 1* No. – (0-100 A) dual scale Ammeter, analog/digital* type, selector switches for ammeters.(d) 1* No. – Microprocessor based numerical relay with O/L, E/F and S/C protection.(e) 1* No. – Set of dual core dual ratio 3 CTs 300/150/5/5 A of 15 VA burden and accuracy Class – 0.5 for metering and class 5P10 for protection.(a) Outgoing – 2Nos. 800Amp. VCB(b) 2Nos. – (0-100 A) Ammeters, dual scale analog/digital* type & selector switches for Ammeters.(c) 2 Nos. – Microprocessor based numerical relays with O/L, E/F & S/C protections.(d) 2 Nos. – Set of dual core dual ratio 3 CTs 100/ 50/5/5 A of 15 VA burden and accuracy Class-1.0 for metering and class 5P10 for protection.1. Supply of power pack 24 volts complete with battery and charging device. |
| 358 | Supply of 50 Sq.mm size XLPE cable from 11 K.V.UPPCL metering panel to 11 KV incoming H.T. switch gear panel and panel to transformer. |
| 359 | Supplying of 100 KVA, 11/0.415 KV, 3 Phase, 50 Hz, Dyn 11, indoor ONAN type, copper wound transformer with OFF load tap changing arrangement on HV side in steps of +/- 2.5% & -7.5%, having cable end boxes on HV side suitable for 3x150sqmm XLPE cable of 33 KV grade and bus trunking arrangement on LV side complete with all accessories i/c first filling of filtered dehydrated oil and confirming to IS 1180 & as per specification attached complete in all respects as required at site. |
| 360 | Supplying of cubicall type LT / MCC panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system fabricated in compartmentalized (preferably) design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having 400 Amp capacity extensible type TPN aluminium alloy bus bars of hight conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with 50sq. mm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears :-(I) Incoming : 2 Nos 200 Amps 4 Pole MCCB of fault breaking capacity 50 KA (Ics=Icu upto 433 V manually operated, fitted with interlocked door, automatic safety shutters, mechanical ON/ OFF and service/test/isolated position indicators and frame earthing contact, conforming to IS 1397- 2 : 1993 as amended up-to-date complete with following accessories for each MCCB.(a) Independent manual spring closing mechanism- 1 No.B10(b) Microprocessor release (EMI & EMC certified) for over current, earth fault & short circuit protection- 1 set. |
| 361 | (c) Analog 96 mm square flush pattern / Digital* type Voltmeter (0-500 V), with selector switch & back up HRC fuses/ MCBs-1 set.(d) Analog 96 mm. square flush pattern/ Digital* type Ammeter (0-630Amp), with selector switch and one set of 3 nos. CT’s of ratio10/5A Class I accuracy and 15 VA burden- 1set. (e) 3 Nos. Phase indication LED lamps with 2 Amp back up HRC fuse, breaker ‘ON’ indicating light with 2 A HRC fuse, test terminal block set, fuses, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required.(f) Shunt trip coil 220 V A.C.(II) Bus Couplers :1Nos. 200 Amps MCCB of fault breaking capacity 50 KA (Ics=Icu upto 433 V) manually operated, with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact conforming to IS 13947- 2 : 1993 as amended upto date complete with following accessories for each MCCB:(a) Independent manual spring closing mechanism- 1 No.(b) Breaker ‘ON’ indicating light with back up 2 A HRC fuse test terminal block, fuses, circuits contactors for positive electrical interlocking of breakers, etc. as required- 1 set.(III) Bus Bars :TPN aluminium bus bars of minimum of 400Amps capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bar cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 Sec.(IV) Interlocking :Electrical through advance contacts in MCCB (incomers & bus couplers) and mech- anical (castel key) interlocking should beprovided to ensure that only one supply is available at a time on each section of bus and to eliminate any possiblility of accidentally approaching two supplies at one bus section.(V) Outgoing :-(A) 1 Nos. 200Amp 4 Pole MCCB of fault breaking capacity 50 KA (Ics=Icu upto 433 V) manually operated, with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact conforming to IS 13947- 2 : 1993 (B) 2 Nos. 80Amp 4 Pole MCCB of fault breaking capacity 50 KA (Ics=Icu upto 433 V) manually operated, with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact conforming to IS 13947- 2 : 1993 (C) 2 Nos. 32Amp MCCB of fault breaking capacity 50 KA (Ics=Icu upto 433 V) manually operated, with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact conforming to IS 13947- 2 : 1993 |
| 362 | (IV) Interlocking :Electrical through advance contacts in ACB’s (incomers & bus couplers) and mech- anical (castel key) interlocking should beprovided to ensure that only one supply is available at a time on each section of bus and to eliminate any possiblility of accidentally approaching two supplies at one bus section.(V) Outgoing :-(A) 1 Nos. 200Amp 4 Pole drawout type, air circuit breakers of fault breaking capacity 50 KA (Ics=Icu upto 433 V) manually operated, with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact conforming to IS 13947- 2 : 1993 (B) 2 Nos. 80Amp 4 Pole drawout type, air circuit breakers of fault breaking capacity 50 KA (Ics=Icu upto 433 V) manually operated, with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact conforming to IS 13947- 2 : 1993 (C) 2 Nos. 32Amp , 4 Pole drawout type, air circuit breakers of fault breaking capacity 50 KA (Ics=Icu upto 433 V) manually operated, with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact conforming to IS 13947- 2 : 1993 SITC of microprocessor based three phase sensing power factor correction relay panel , IEC / EN 61000-6- (2&4) having 3 CT sensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall have digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, communication interface with RS 485, indication ofswitching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like KW, KVA, KVAR rating capacity of 25 KVAR |
| 363 | SITC of Auto Phase reversal unit with inbuilt time delay & enclosure ( confirm to IEC:60947-1 & IEC:60947-b-1) |
| 364 | 200Amp Rating |
| 365 | Supply and laying of 650/1100 volt grade 240sq mm 3½ core PVC Armoured Aluminium cable from transformer to L.T / MCC panel (1x3½x240 sq mm) |
| 366 | Making Earth pit for earthing complete in all respect. Earthing system shall executed as per IS:3043 and I.E. rules. |
| 367 | Installation and commissioning of 11 KV/0.4 KV substations including HT Panels and L.T. main control panel including all labor T&P complete in all respect. |
| 368 | Supply and making of indoor cable end termination joint kit of size 70 sq mm 3 core for 11 KV H.T. XLPE cable |
| 369 | Supply and making of outdoor cable end termination joint kit of size 240 sq mm 3 core for 11 KV H.T. XLPE cable |
| 370 | Provision for routine testing of equipments such as transformer, HT Panels and main LT Panel at manufacturer’s works. |
| 371 | NOC from Electrical safety department for all field installations such as pumping plants, substation etc. |
| 372 | Master Control Station ( MCS ) |
| 373 | CE & BIS approved manufacturer's industrial grade LCD monitor with latest configuration as per specification of size 65\\" |
| 374 | Desktop/PC as per spec. mentioned |
| 375 | CE/UL approved manufacturer's 5 KVA UPS with batteries as spec. mentioned for Computer as per requirement |
| 376 | Full development version of required TAGS SCADA Software with customization of software for MCS as per requirement as per specification mentioned. |
| 377 | CE & UL approved manufacturer's control room PLC with CPU & power supply at MCS in IP65 enclosure as per spec. mentioned |
| 378 | CE/UL certified field gateway agent for transfering data from MCS to control room |
| 379 | GSM based wireless / broadband/Equipment communication system for PLC capable to transfer and gather data from remote sites to control stations, including all accessories complete |
| 380 | CE/UL approved manufacturer's Firewall for network protection |
| 381 | Lightning surge protector for ethernet communication protection |
| 382 | CE/UL approved manufacturer's industrial grade ethernet switch |
| 383 | Mobile App facility system architecture complete. |
| 384 | Canon/HP 1018/equivalent Laser printer |
| 385 | Security Survelliance IP camera |
| 386 | Installation, testing and commissioning with required furniture,Air Conditioner etc |
| 387 | AUTOMATION FOR INTAKE WELL |
| 388 | CE & UL Certified PLC/RTU with redudant CPU & Power supply in IP 54 enclosure suitable to Communicate with GSM based modem unit with redudant CPU & Power Supply with analog & digital parameter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations with control panel as specified in tender technical specification. |
| 389 | GSM / GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories including with signal enhancer antanna made for pumping plant internet charges as specified in tender technical specification. |
| 390 | CE/UL Certified Intelligent energy meters |
| 391 | CE/UL Certified Surge protector for control panel |
| 392 | CE/UL Certified 3 KVA UPS with batteries as per technical bid documents |
| 393 | CE/UL Certified 10\\" touch screen suitable for communication with PLC/RTU for local display & control of process parameters. |
| 394 | Control Panel with IP-54 Protection, industrial grade for all equipment. Separate for control (24V) and power equipments |
| 395 | Turbidity Analyzer at CWR |
| 396 | PH Analyzer |
| 397 | Chlorine Analyzer |
| 398 | Cable |
| 399 | (i) Complete cabling upto 3 Pumps |
| 400 | Security Survelliance IP Camera with recorder (optional) |
| 401 | Installation, commissioning & testing |
| 402 | AUTOMATION FOR MCWR ( WTP ) |
| 403 | CE & UL Certified PLC/RTU with redudant CPU & Power supply in IP 54 enclosure suitable to Communicate with GSM based modem unit with redudant CPU & Power Supply with analog & digital parameter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations with control panel as specified in tender technical specification. |
| 404 | GSM / GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories including with signal enhancer antanna made for pumping plant internet charges as specified in tender technical specification. |
| 405 | CE/UL Certified Intelligent energy meters |
| 406 | CE/UL Certified Surge protector for control panel |
| 407 | CE/UL Certified 3 KVA UPS with batteries as per technical bid documents |
| 408 | CE/UL Certified 10\\" touch screen suitable for communication with PLC/RTU for local display & control of process parameters. |
| 409 | Control Panel with IP-54 Protection, industrial grade for all equipment. Separate for control (24V) and power equipments |
| 410 | Turbidity Analyzer at CWR |
| 411 | PH Analyzer |
| 412 | Chlorine Analyzer |
| 413 | Cable |
| 414 | (i) Complete cabling upto 3 Pumps |
| 415 | Security Survelliance IP Camera with recorder (optional) |
| 416 | Installation, commissioning & testing |
| 417 | AUTOMATION FOR CCWR |
| 418 | CE & UL Certified PLC/RTU with redudant CPU & Power supply in IP 54 enclosure suitable to Communicate with GSM based modem unit with redudant CPU & Power Supply with analog & digital parameter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations with control panel as specified in tender technical specification. |
| 419 | GSM / GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories including with signal enhancer antanna made for pumping plant internet charges as specified in tender technical specification. |
| 420 | CE/UL Certified Intelligent energy meters |
| 421 | CE/UL Certified Surge protector for control panel |
| 422 | CE/UL Certified 3 KVA UPS with batteries as per technical bid documents |
| 423 | CE/UL Certified 10\\" touch screen suitable for communication with PLC/RTU for local display & control of process parameters. |
| 424 | Control Panel with IP-54 Protection, industrial grade for all equipment. Separate for control (24V) and power equipments |
| 425 | Turbidity Analyzer at CWR |
| 426 | PH Analyzer |
| 427 | Chlorine Analyzer |
| 428 | Cable |
| 429 | (i) Complete cabling upto 3 Pumps |
| 430 | Security Survelliance IP Camera with recorder (optional) |
| 431 | Installation, commissioning & testing |
| 432 | AUTOMATION FOR CWR-3 |
| 433 | CE & UL Certified PLC/RTU with redudant CPU & Power supply in IP 54 enclosure suitable to Communicate with GSM based modem unit with redudant CPU & Power Supply with analog & digital parameter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations with control panel as specified in tender technical specification. |
| 434 | GSM / GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories including with signal enhancer antanna made for pumping plant internet charges as specified in tender technical specification. |
| 435 | CE/UL Certified Intelligent energy meters |
| 436 | CE/UL Certified Surge protector for control panel |
| 437 | CE/UL Certified 3 KVA UPS with batteries as per technical bid documents |
| 438 | CE/UL Certified 10\\" touch screen suitable for communication with PLC/RTU for local display & control of process parameters. |
| 439 | Control Panel with IP-54 Protection, industrial grade for all equipment. Separate for control (24V) and power equipments |
| 440 | Turbidity Analyzer at CWR |
| 441 | PH Analyzer |
| 442 | Chlorine Analyzer |
| 443 | Cable |
| 444 | (i) Complete cabling upto 3 Pumps |
| 445 | Security Survelliance IP Camera with recorder (optional) |
| 446 | Installation, commissioning & testing |
| 447 | INSTRUMENTATION AGAINST ZONE-1 ( DMA-1 Nos ) |
| 448 | Supply of Motor operated actuator with sluice valve at CWR ( On Hill ) outlet :- Supply of DI/DF Electrically integrated actuater with sluice valve (Totally enclosed, weather-proof and dust proof construction with IP-67, protection class suitable for installation in any position without lubrication, leakage or other operational difficulty with special grease filled gear box and suitable for manual operation for emergency which will automatically dis-engage on restoration of power to motor and with10 watt single phase space heater and continuous local mechanical position indicator and individually replaceable counter gear assembly and with two torque and four limit switches with S.S. flap and operated with gear driven cams and of rating 250 Volt, 5 Amp, AC/DC, torque switch dial and with TEFC squirrel cage induction) operated suitable to SCADA operation sluice valve having body door cover of graded in cast iron to IS:210 Gr.Fg.260 body and door rings of SS ASTM A743 Gr.CF8 and bearing block of leaded tin bronze to IS:318 Gr.LTB2 hinge pin of stainless steel AISI:431.Valves generally conform to IS:5312.Flanges to be drilled as per IS:1538 Part-IV &VI. Valves are suitable for hydrostatic test pressure of 10Kg./Cm2 for seat and 15Kg./Cm2 for body(PN-1.0) of following sizes |
| 449 | 250 mm dia |
| 450 | Supply of isolation valve with electric actuator for isolation of DMA,pressure monitoring and web based with cable PLC etc Complete at DMA inlet. |
| 451 | 250 mm (DMA-1) |
| 452 | Supply of flow control valve with electric actuator for flow controling,pressure monitoring and web based with cable PLC etc Complete at DMA inlet. |
| 453 | 250 mm (DMA-1) |
| 454 | Supply of DI/DF mechanical joint as per requirement and departments approved drawing and specifications, including machining and rubber ring and suitable for 16 kg/cm2 working pressure with required flanges of suitable side with nut and bolt etc. complete. The joint should have long bolts so that during normal working pressure there should be no sliding movement of sliding flanges LOF (length over flange) should not be less than 75% of dia at DMA inlet. |
| 455 | 250 mm (DMA-1) |
| 456 | Supply of CE/UL Certified level transmitter for CWR ( On Hill ) :- Supply of Radar type level transmitter with CE marked with following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4\\" LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 |
| 457 | Supply of CE/UL Certified Electromagnetic flow meter at DMA inlet :- Supply of CE/UL Full Bore Electromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) , Pressure : up to 1.0 MPa, Process temp:- 50 deg C, Flow/Meter Tube : SS 304, Electrode : SS AISI 316L / Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement ‘of IEC 60529, Accuracy : + 0.5 % M.V. velocity 0.3 to 10 m/s, Transmitter/ signa convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 5OHz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parameters and totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable. |
| 458 | 250 mm (DMA-1) |
| 459 | Supply of CE/UL Certified Pressure transmitter at DMA inlet :- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4\\" LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 |
| 460 | Supply of Dosing System at DMA inlet :-Supply of Electro Mechanical type Chemical dosing system 0 to 6 LPH capacity on working pressure 4kg/cm2 to feed Sodium hypo chloride complete set with 100 Litre solution tank.( SCADA Compatible ) |
| 461 | Supply of Residual chlorine analyser / meter at DMA inlet :- Supply of RCA must have automatic sensor cleaning facility at pure water sump and Interfacing with PLC panel. Residual Chlorine meter shall comprises of 3 components i.e. sensors, flow through assembly and transmitter with indicator andgives 2 outputs one to Local display & other to PLC including Mounting arrangement.Overall Range : 0 - 8 mg/l (ppm)Accuracy : 2% of full scaleSupply Voltage : 230 V acOutput : 4-20 mAMembrane free sensor of 2 gold plated electrodes for long term stability and reference electrode (ag/Agcl) must be provided to avoid maintenance. IP 65 Nema 4 housing protection class required. |
| 462 | 10 KVA 3/1:1 Phase Rack Mountable Easy On_x0002_Line UPS HSN/SAC Code: -85049090 , SMF BATTERIES 12V-18 AH (EP Series) HSN/SAC Code: -85072000 Battery Rack for 20 Nos 12 V-17/18 AH Batteries HSN/SAC Code: -73269099 , interlink Connector for 10 KVA UPS - 240 V DC HSN/SAC Code: -85366990 |
| 463 | Installation, cabling of OHT including all equipments with all power and control cable,testing and commissioning complete in all respect. |
| 464 | ESTIMATE FOR INSTRUMENTATION AGAINST ZONE-2 ( DMA-2 Nos ) |
| 465 | Supply of Motor operated actuator with sluice valve at OHT outlet :- Supply of DI/DF Electrically integrated actuater with sluice valve (Totally enclosed, weather-proof and dust proof construction with IP-67, protection class suitable for installation in any position without lubrication, leakage or other operational difficulty with special grease filled gear box and suitable for manual operation for emergency which will automatically dis-engage on restoration of power to motor and with10 watt single phase space heater and continuous local mechanical position indicator and individually replaceable counter gear assembly and with two torque and four limit switches with S.S. flap and operated with gear driven cams and of rating 250 Volt, 5 Amp, AC/DC, torque switch dial and with TEFC squirrel cage induction) operated suitable to SCADA operation sluice valve having body door cover of graded in cast iron to IS:210 Gr.Fg.260 body and door rings of SS ASTM A743 Gr.CF8 and bearing block of leaded tin bronze to IS:318 Gr.LTB2 hinge pin of stainless steel AISI:431.Valves generally conform to IS:5312.Flanges to be drilled as per IS:1538 Part-IV &VI. Valves are suitable for hydrostatic test pressure of 10Kg./Cm2 for seat and 15Kg./Cm2 for body(PN-1.0) of following sizes |
| 466 | 350 mm dia |
| 467 | Supply of isolation valve with electric actuator for isolation of DMA,pressure monitoring and web based with cable PLC etc Complete at DMA inlet. |
| 468 | 300 mm (DMA-1,2) |
| 469 | Supply of flow control valve with electric actuator for flow controling,pressure monitoring and web based with cable PLC etc Complete at DMA inlet. |
| 470 | 300 mm (DMA-1,2) |
| 471 | Supply of DI/DF mechanical joint as per requirement and departments approved drawing and specifications, including machining and rubber ring and suitable for 16 kg/cm2 working pressure with required flanges of suitable side with nut and bolt etc. complete. The joint should have long bolts so that during normal working pressure there should be no sliding movement of sliding flanges LOF (length over flange) should not be less than 75% of dia at DMA inlet. |
| 472 | 300 mm (DMA-1,2) |
| 473 | Supply of CE/UL Certified level transmitter for OHT :- Supply of Radar type level transmitter with CE marked with following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4\\" LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 |
| 474 | Supply of CE/UL Certified Electromagnetic flow meter at DMA inlet :- Supply of CE/UL Full Bore Electromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) , Pressure : up to 1.0 MPa, Process temp:- 50 deg C, Flow/Meter Tube : SS 304, Electrode : SS AISI 316L / Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement ‘of IEC 60529, Accuracy : + 0.5 % M.V. velocity 0.3 to 10 m/s, Transmitter/ signa convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 5OHz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parameters and totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable. |
| 475 | 300 mm (DMA-1,2) |
| 476 | Supply of CE/UL Certified Pressure transmitter at DMA inlet :- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4\\" LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 |
| 477 | Supply of Dosing System at DMA inlet :-Supply of Electro Mechanical type Chemical dosing system 0 to 6 LPH capacity on working pressure 4kg/cm2 to feed Sodium hypo chloride complete set with 100 Litre solution tank.( SCADA Compatible ) |
| 478 | Supply of Residual chlorine analyser / meter at DMA inlet :- Supply of RCA must have automatic sensor cleaning facility at pure water sump and Interfacing with PLC panel. Residual Chlorine meter shall comprises of 3 components i.e. sensors, flow through assembly and transmitter with indicator andgives 2 outputs one to Local display & other to PLC including Mounting arrangement.Overall Range : 0 - 8 mg/l (ppm)Accuracy : 2% of full scaleSupply Voltage : 230 V acOutput : 4-20 mAMembrane free sensor of 2 gold plated electrodes for long term stability and reference electrode (ag/Agcl) must be provided to avoid maintenance. IP 65 Nema 4 housing protection class required. |
| 479 | 10 KVA 3/1:1 Phase Rack Mountable Easy On_x0002_Line UPS HSN/SAC Code: -85049090 , SMF BATTERIES 12V-18 AH (EP Series) HSN/SAC Code: -85072000 Battery Rack for 20 Nos 12 V-17/18 AH Batteries HSN/SAC Code: -73269099 , interlink Connector for 10 KVA UPS - 240 V DC HSN/SAC Code: -85366990 |
| 480 | Installation, cabling of OHT including all equipments with all power and control cable,testing and commissioning complete in all respect. |
| 481 | INSTRUMENTATION AGAINST ZONE-3 ( DMA-2 Nos ) |
| 482 | Supply of Motor operated actuator with sluice valve at OHT outlet :- Supply of DI/DF Electrically integrated actuater with sluice valve (Totally enclosed, weather-proof and dust proof construction with IP-67, protection class suitable for installation in any position without lubrication, leakage or other operational difficulty with special grease filled gear box and suitable for manual operation for emergency which will automatically dis-engage on restoration of power to motor and with10 watt single phase space heater and continuous local mechanical position indicator and individually replaceable counter gear assembly and with two torque and four limit switches with S.S. flap and operated with gear driven cams and of rating 250 Volt, 5 Amp, AC/DC, torque switch dial and with TEFC squirrel cage induction) operated suitable to SCADA operation sluice valve having body door cover of graded in cast iron to IS:210 Gr.Fg.260 body and door rings of SS ASTM A743 Gr.CF8 and bearing block of leaded tin bronze to IS:318 Gr.LTB2 hinge pin of stainless steel AISI:431.Valves generally conform to IS:5312.Flanges to be drilled as per IS:1538 Part-IV &VI. Valves are suitable for hydrostatic test pressure of 10Kg./Cm2 for seat and 15Kg./Cm2 for body(PN-1.0) of following sizes |
| 483 | 350 mm dia |
| 484 | Supply of isolation valve with electric actuator for isolation of DMA,pressure monitoring and web based with cable PLC etc Complete at DMA inlet. |
| 485 | 300 mm (DMA-1,2) |
| 486 | Supply of flow control valve with electric actuator for flow controling,pressure monitoring and web based with cable PLC etc Complete at DMA inlet. |
| 487 | 300 mm (DMA-1,2) |
| 488 | Supply of DI/DF mechanical joint as per requirement and departments approved drawing and specifications, including machining and rubber ring and suitable for 16 kg/cm2 working pressure with required flanges of suitable side with nut and bolt etc. complete. The joint should have long bolts so that during normal working pressure there should be no sliding movement of sliding flanges LOF (length over flange) should not be less than 75% of dia at DMA inlet. |
| 489 | 300 mm (DMA-1,2) |
| 490 | Supply of CE/UL Certified level transmitter for OHT :- Supply of Radar type level transmitter with CE marked with following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4\\" LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 |
| 491 | Supply of CE/UL Certified Electromagnetic flow meter at DMA inlet :- Supply of CE/UL Full Bore Electromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) , Pressure : up to 1.0 MPa, Process temp:- 50 deg C, Flow/Meter Tube : SS 304, Electrode : SS AISI 316L / Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement ‘of IEC 60529, Accuracy : + 0.5 % M.V. velocity 0.3 to 10 m/s, Transmitter/ signa convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 5OHz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parameters and totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable. |
| 492 | 300 mm (DMA-1,2) |
| 493 | Supply of CE/UL Certified Pressure transmitter at DMA inlet :- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4\\" LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 |
| 494 | Supply of Dosing System at DMA inlet :-Supply of Electro Mechanical type Chemical dosing system 0 to 6 LPH capacity on working pressure 4kg/cm2 to feed Sodium hypo chloride complete set with 100 Litre solution tank.( SCADA Compatible ) |
| 495 | Supply of Residual chlorine analyser / meter at DMA inlet :- Supply of RCA must have automatic sensor cleaning facility at pure water sump and Interfacing with PLC panel. Residual Chlorine meter shall comprises of 3 components i.e. sensors, flow through assembly and transmitter with indicator andgives 2 outputs one to Local display & other to PLC including Mounting arrangement.Overall Range : 0 - 8 mg/l (ppm)Accuracy : 2% of full scaleSupply Voltage : 230 V acOutput : 4-20 mAMembrane free sensor of 2 gold plated electrodes for long term stability and reference electrode (ag/Agcl) must be provided to avoid maintenance. IP 65 Nema 4 housing protection class required. |
| 496 | 10 KVA 3/1:1 Phase Rack Mountable Easy On_x0002_Line UPS HSN/SAC Code: -85049090 , SMF BATTERIES 12V-18 AH (EP Series) HSN/SAC Code: -85072000 Battery Rack for 20 Nos 12 V-17/18 AH Batteries HSN/SAC Code: -73269099 , interlink Connector for 10 KVA UPS - 240 V DC HSN/SAC Code: -85366990 |
| 497 | Installation, cabling of OHT including all equipments with all power and control cable,testing and commissioning complete in all respect. |
| 498 | AUTOMATION OF DMA |
| 499 | CE & UL Certified PLC/RTU in IP 54 enclosure suitable to Communicate with GSM based modem unit with CPU & Power Supply with analog & digital parameter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations with control panel as specified in tender technical specification. |
| 500 | GSM / GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories including with signal enhancer antanna made for pumping plant internet charges as specified in tender technical specification. |
| 501 | CE/UL Certified Intelligent energy meters |
| 502 | CE/UL Certified Surge protector for control panel |
| 503 | CE/UL Certified 1 KVA UPS with batteries as per technical bid documents |
| 504 | CE/UL Certified 7\\" touch screen suitable for communication with PLC/RTU for local display & control of process parameters. |
| 505 | Control Panel with IP-54 Protection, industrial grade for all equipment. Separate for control (24V) and power equipments |
| 506 | Cable |
| 507 | (i) Complete cabling |
| 508 | Security Survelliance IP Camera with recorder (optional) |
| 509 | Installation, commissioning & testing |
| 510 | 3 Months Trail Run for Intakewell, MCWR, CCWR, CWR Including operation and chemical Charges Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail