| 1 | Providing Skilled Electrician with tool kits for day to day inspection, monitoring, maintenance of Pumps, motors, Panels, sub-station and other installations at all the prescribed sites for 2 days/week etc. complete as per directions of Engineer-in-charge. The job includes all taxes, transportation, machinery, tool kits, etc. complete.(Excluding GST). |
| 2 | Dismantling & overhauling of Vertical Turbine pumps from the position having 10 mtrs. suspended length (from Bell Mount to Discharge Head.), cleaning, checking, aligning, assembling i.e., refitting, commissioning with trial run on no load & full load for at least 30 minutes including replacement of spare parts, fastners (which shall be made available by MIDC at free of cost at site of work) etc. complete as per site requirements. |
| 3 | a) 10 H.P. to 50 H.P. |
| 4 | b) above 225 H.P. to 500 H.P. |
| 5 | Dismantling & overhauling of Centrifugal monoblock pumps from the position, cleaning, checking, aligning, assembling i.e., refitting, commissioning with trial run on no load & full load for at least 30 minutes including replacement of spare parts, fastners (which shall be made available by MIDC at free of cost at site of work) etc. complete as per site requirements. |
| 6 | Dismantling & overhauling of Submersible pumps from the position , cleaning, checking, aligning, assembling i.e., refitting, commissioning with trial run on no load & full load for at least 30 minutes including replacement of spare parts, fastners (which shall be made available by MIDC at free of cost at site of work) etc. complete as per site requirements. |
| 7 | Providing, Fabrication of spares for the pumping machinery suitable to match with the existing fitments & as per actual site conditions including cost of material, salvage, machining, taxes & duties, incidentals, overheads, packing & forwarding etc. complete as per designation given below. |
| 8 | 250 HP VT Pumps |
| 9 | a) Line shaft EN8 Size-50mm x1.55m |
| 10 | b) Line shaft sleeve SS304-Size-8Inch (ID-50mm)x8mm Thick |
| 11 | c) Head shaft with lock nut EN8, Size-50mmx 1.8m |
| 12 | d) Line shaft baring neoprene rubber |
| 13 | e) Spider |
| 14 | f) Line shaft coupling EN8 |
| 15 | g) Column pipe |
| 16 | h) Bowl bush (Gun metal) |
| 17 | i) Suction case bearing & discharge case bearing |
| 18 | j) MS nut bolt |
| 19 | k) Neck ring |
| 20 | l) Stuffing box bush -Gun metal |
| 21 | m) Gland cap with stud & nut- bolt |
| 22 | n) PTFE gland packing- 3/8 size |
| 23 | o) Impeller (Bronze) |
| 24 | Providing, Fabrication of spares for the pumping machinery suitable to match with the existing fitments & as per actual site conditions including cost of material, salvage, machining, taxes & duties, incidentals, overheads, packing & forwarding etc. complete as per designation given below for Halkarni Jackwell. |
| 25 | 50 HP VT Pumps |
| 26 | a) Line shaft EN8 |
| 27 | b) Line shaft sleeve SS304 |
| 28 | c) Head shaft with lock nut EN8 |
| 29 | d) Line shaft baring neoprene rubber |
| 30 | e) Spider |
| 31 | f) Line shaft coupling EN8 |
| 32 | g)Bowl bush (Gun metal) |
| 33 | h) Suction case bearing & discharge case bearing |
| 34 | i) MS nut bolt |
| 35 | j) Stuffing box with bush |
| 36 | k) Gland cap with stud & Nut- bolt |
| 37 | l) Impeller |
| 38 | Providing, Fabrication of spares for the pumping machinery suitable to match with the existing fitments & as per actual site conditions including cost of material, salvage, machining, taxes & duties, incidentals, overheads, packing & forwarding etc. complete as per designation given below for Halkarni Jackwell. |
| 39 | 1) 250 HP @ Jackwell Siddhanerli |
| 40 | 2) 50 HP @ Jackwell Halkarni |
| 41 | Rewinding of electric motor above 1 HP and upto 2 HP three phase upto 1400 RPM of all types and makes with copper wire conforming to IS 13730 :2012, overhauling with minor repairs, lubricating of ball bearings & bush bearing, replacing screws etc. testing for the original speed and no load consumption with guarantee for one year |
| 42 | Rewinding of electric motor above 3 H.P.upto 5 H.P. three phase up to 1400 RPM of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one year |
| 43 | Rewinding of electric motor above 5 HP upto 7.5 HP three phase upto 1400 RPM of all types and makes with copper wire confirming to IS 13730 : 2012, overhauling with minor repairs, lubricating of ball bearings & bush bearing, replacing screws etc. testing for the original speed and no load consumption with guarantee for one year |
| 44 | Rewinding of electric motor above 10 H.P. upto 12.5 H.P. three phase up to 1400 RPM of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one year |
| 45 | Rewinding of electric motor above 15 HP upto 20 HP three phase upto 1400 RPM of all types and makes with copper wire confirming to IS 13730 : 2012, overhauling with minor repairs, lubricating of ball bearings & bush bearing, replacing screws etc. testing for the original speed and no load consumption with guarantee for one year |
| 46 | Rewinding of Auto transformers including dismantling, rewinding with new insulated copper wire/strips of proper size, varnishing/ backing and filling with fresh transformer oil, painting assembly and testing of works and delivery at site.(The scrap of winding material shall be retained by rewinder). |
| 47 | 1) 41 to 60 HP |
| 48 | 2) 200 to 250HP |
| 49 | Servicing and overhauling of motors, including removing from location, dismantling cleaning the winding, drying, applying, varnish, baking, changing the bearing if necessary (bearing will be supplied by MIDC) greasing the bearing, assembling, and giving satisfactory trials on No load and full load etc. |
| 50 | 1) 415 volts, 3 phase upto 5 HP to 15 HP |
| 51 | 2) 415 volts, 3 phase upto 20 HP to 35 HP |
| 52 | 3) 415 volts, 3 phase upto 40 HP to 50 HP |
| 53 | 4) 415 volts, 3 phase upto 225 HP to 250 HP |
| 54 | Overhauling & Servicing of monorail/trolly electrically operated overhead cranes with oiling, greasing, adjustment & alignment ofbreakshoes, electomagnetic switches, pendant instrument clusters, longitudinal; cross & vercal travels, ON/OFF i.e., start/ stop mechanism, wire ropes, chain pulley blocks, slings, safety & or non reverse rachets, antifriction arrangements etc. complete with issuance of test certificates as required by annual inspecting relevant authorities. 1) above 2 M.T. to 10 M.T. Capacity |
| 55 | Painting of electrical, mechanical machinery such as pump sets, panels, motors, compressors, surge arrestors, transformers, HT and LT breakers, including rubbing down oil paint, cleaning with emery papers and making the surface clean to receive the paints and providing and applying one coat of primer and two coats of synthetic super enamel painting conforming to IS of approved colour and shade, including scaffolding, if necessary. |
| 56 | Replacing the existing driving end bearing of original make for electric motor AC single phase / three phase 1.5 HP to 2 HP of all types with required alignment of the shaft and testing the same. |
| 57 | Replacing the existing non driving end bearing of original make for electric motor AC single phase / three phase 1.5 HP to 2 HP of all types with required alignment of the shaft and testing the same. |
| 58 | Replacing the existing driving end bearing of original make for electric motor AC single phase / three phase 3 HP to 7.5 HP of all types with required alignment of the shaft and testing the same.. |
| 59 | Replacing the existing non driving end bearing of original make for electric motor AC single phase / three phase 3 HP to 7.5 HP of all types with required alignment of the shaft and testing the same. |
| 60 | Replacing the existing driving end bearing of original make for electric motor AC single phase / three phase 10 HP of all types with required alignment of the shaft and testing the same. |
| 61 | Replacing the existing non driving end bearing of original make for electric motor AC single phase / three phase 10 HP of all types with required alignment of the shaft and testing the same. |
| 62 | Replacing the existing driving end bearing of original make for electric motor AC single phase / three phase 12.5 HP to 20 HP of all types with required alignment of the shaft and testing the same. |
| 63 | Replacing the existing non driving end bearing of original make for electric motor AC single phase / three phase 12.5 HP to 20 HP of all types with required alignment of the shaft and testing the same. |
| 64 | Supply & fixing of bearings for 50 HP induction Motor DE/NDE 6312/7316 |
| 65 | Providing & erecting 3 Pole MCCB 415V, 250A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB |
| 66 | Supplying, erecting, testing and commissioning of fully automatic star/delta starter suitable for above 15 HP upto 25 HP for three phase squirrel cage motor totally enclosed with overload and no volt relay complete erected on provided angle iron frame. |
| 67 | Supplying, erecting, testing and commissioning of D.O.L starter suitable for 400 V, 3 phase 50 Hz with no volt coil and overload element with necessary materials and connected to supply above 3 HP to 7.5 HP. |
| 68 | Supplying, erecting, testing and commissioning of D.O.L Starter suitable for 400 V, 3 phase 50 Hz with no volt coil and overload element with necessary materials and connected to supply for above 7.5 HP 10 HP. |
| 69 | Providing & erecting 3 Pole MCCB, 415V, up to 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-MCCB. For use of 4 pole MCCBs in place of 3 pole MCCBs add 20% in rate of 3 pole MCCB. (5808 x 20% = 1161.6 + 5808 =6969.6; say as 6970 |
| 70 | Repairs & overhauling of 50 HP rotary air blower at WTP, Kagal by dismantling of 50 HP KAY make Twin Rotor Air Blowers having Sr. No. 37KE4TOP from its position including side plate, Rotor's, Cylinder inlet section, outlet suction pipe, Air Filter's, Bearings, Side Gear, etc. using tools labours chain pulley, Bearing puller, etc. as directed by Engineer in charge. |
| 71 | Credit of old dismentled material of VT pump, centrifugal pump, Panel switchgears, bearings etc. Please Enable Macros to View BoQ information |