| 1 | Schedule 'A' |
| 2 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, poles struts, laying of cables/pipes, etc., not exceeding 10 Sqm on plan and not exceeding 1.5m in depth and getting out in hard/dense soil complete all as specified and directed. |
| 3 | Excavating in trenches, n exc 1.5 m wide and exc 1.5 m but not exc 3.00 in depth; for foundation of ploes laying of cables etc. n exc 10 sqm on plan area and getting out in hard/densy soil complete all as specified and directed. |
| 4 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm as in soils complete all as specified and as directed. |
| 5 | Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 mtr above the starting point as in soils complete all as specified and as directed. |
| 6 | Supply and spread sand in trenches as sand cushioning to underground cable for protection with dry fine river sand and provide required cover after punning down 18CM will be measured and paid complete all as specified and directed.(Note: Thickness of sand cushion after punning down will be measured and paid.) |
| 7 | Supply and laying well burnt sub class ‘B’ bricks ( designated 75) locally available best quality, laid dry in trenches for protection of underground cable all as specified and directed. |
| 8 | S&F in repair of steel tubular swaged poles, type 410 SP 31 (Overall length 9.00 m) complete with cast iron base plate, finial taper plug, bolts, nuts screws and washers including painting two coats of black bituminous paint internally and externally up to planting depth and remaining external portion with two coats of aluminum paints over a coat of red oxide primer and writing pole Nos with white paint on black back ground complete all as specified and as directed. |
| 9 | S&F in repair stay assembly 20 mm dia stay rod complete with accessories as shown in electrical plate No. 1 of SSR part-1 complete all as specified and directed. (Note :- Excavation and concrete shall be measured separately) |
| 10 | S&F in repair of galvanized stay strand of size 7/3.15 mm complete all as specified and directed. |
| 11 | M&L for plain cement concrete in repair 1:4:8 type D2 using 40 mm graded crushed stone aggregate as in foundation of pole, protection of UG cable, concrete base, etc complete all as specified and directed. |
| 12 | M&L for plain cement concrete in repair (1:3:6) type C1 using 20mm graded crushed stone aggregate in coping of pole, concrete base work, protection of cable complete all as specified and directed. |
| 13 | Supply, laying, Jointing connecting in repair of LT UG cable XLPE insulated,PVC bedded galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 10 sqmm 2 core laid in trenches / on poles / walls / in ducts / passing through pipes and including necessary cable lugs, bolts, nuts and washers complete all as specified and directed. (Make: Havells/KEI/Polycab/Gloster/Finolex). |
| 14 | All as per serial item No. 12 above but for 10 Sqmm 4 Core. |
| 15 | All as per serial item No. 12 above but for 16 Sqmm 4 Core. |
| 16 | All as per serial item No. 12 above but for 25 Sqmm 4 Core. |
| 17 | All as per serial item No. 12 above but for 35 Sqmm 3.5 Core. |
| 18 | All as per serial item No. 12 above but for 50 Sqmm 3.5 Core. |
| 19 | All as per serial item No. 12 above but for 70 Sqmm 3.5 Core |
| 20 | All as per serial item No. 12 above but for 95 Sqmm 3.5 Core. |
| 21 | All as per serial item No. 12 above but for 120 Sqmm 3.5 Core. |
| 22 | All as per serial item No. 12 above but for 150 Sqmm 3.5 Core. |
| 23 | All as per serial item No. 12 above but for 185 Sqmm 3.5 Core. |
| 24 | All as per serial item No. 12 above but for 240 Sqmm 3.5 Core. |
| 25 | All as per serial item No. 12 above but for 300 Sqmm 3.5 Core. |
| 26 | S&F in repair MCCB 4 pole, 415 V, 63 Amp with breaking capacity 16 KA complete all as specified and directed. |
| 27 | S&F in repair MCCB 4 pole, 415 V, 100 Amp with breaking capacity 16 KA complete all as specified and directed. |
| 28 | S&F in repair MCCB 4 pole, 415 V,125 Amp with breaking capacity 16 KA complete all as specified and directed. |
| 29 | S&F in repair MCCB 4 pole, 415 V, 160 Amp with breaking capacity 36 KA complete all as specified and directed. |
| 30 | S&F in repair MCCB 4 pole, 415 V, 200 Amp with breaking capacity 36 KA complete all as specified and directed. |
| 31 | S&F in repair MCCB 4 pole, 415 V, 250 Amp with breaking capacity 36 KA complete all as specified and directed. |
| 32 | S&F in repair MCCB 4 pole, 415 V, 400 Amp with breaking capacity 36 KA complete all as specified and directed. |
| 33 | Supply and laying in repair of GI tubing 40 mm bore, medium grade as in cable protection pipe including all fittings complete all as specified and directed. |
| 34 | Supply and laying in replacement of GI tubing 80 mm bore, medium grade as in cable protection pipe including all fittings complete all as specified and directed. |
| 35 | M&L in repair of stringing ACSR conductor of any size including all binding wires and aluminium jointing, jumpering etc maintaining standard sag on LT OH lines complete all as specified and directed. |
| 36 | M&L in repair for streching, tightening and restringing of existing ACSR conductors of any size and type and GI continuous earth conductors of any size, maintaining standard sag including providing aluminium binding wire and fixing of GI conductor complete all as specified and as directed. |
| 37 | S&F in repair of cross arms, bracing, clamps and back plates fabricated from structural steel section including nuts, bolts, washers etc, drilling hole for bolts in any shape or size with welding, bending cold or hot including painting two coats of aluminium paint over a coat of primer complete all as specified and directed. |
| 38 | S&F in repair pin type porcelain insulator of size 100 mm height, 65mm dia, vitreous, white, brown or green including one galvanized mild steel spindle, two galvanized iron washer and one galvanized iron nut for 1100 volts grade complete all as specified as directed. Make : BHEL/Pactil/Jaypuria Brothers |
| 39 | S&F in repair shackle type insulator, porcelain, vitreous, white, brown or green, 75 mm height 90 mm dia for working pressure of 1100 volts including galvanized steel straps of section 31x3 mm, 12 mm dia of bolts, washers and nuts complete all as specified and directed. Make : BHEL/Pactil/Jaypuria Brothers |
| 40 | S&F in repair loop type insulator, vitreous porcelain, white, brown or green small size, with overall dimensions 65 x 90 mm, clearance of hole 16mm complete all as directed.Make : BHEL/Pactil/Jaypuria Brothers |
| 41 | Material and labour for cutting of road/ hard standing n exc 20cm width and n exc 40cm in depth for laying of cable protection pipe including making good the disturbed road/hard standing by providing PCC (1:2:4) type B1 to match with existing surface complete all as directed. |
| 42 | M&L for cleaning, scrapping, preparing of old painted steel tubular pole 9m long and applying one coat of aluminium red oxide primer and two coat of aluminium paint to pole and accessories / fittings whatever fixed on pole including marking/writing pole No on each pole with yellow SE paint with 5cm large bold letters on black background of suitable size at a height of 2m above GL complete all as specified and directed. |
| 43 | Trimming / cutting of the tree branches / bushes which falls within a clear distance of 3 meter from all sides from the LT over head conductor & within line of conductors, and shifting waste to nearby waste depot & cleaning area complete.Note :- Horizontal distance of tree touching to the over head lines shall be measured for the purpose of payment |
| 44 | S & F in repair Service wire connection incl GI wire one twin core 10 sq mm, 2 core 1100 volts grde heavy duty flat or circular cable multi stranded with aluminium conductor PVC insulated served with inner sheathing of PVC tape incl removing the existing unsv one. Complete all as specified and directed. Make: Havells/KEI/Polycab/Nicco/RR Kabel/Finolex. |
| 45 | S&F in repair of LT over head line seperator (4 wire in a single sepertor) on over head lines complete all as specified & directed. |
| 46 | M&L in repair of earthing complete with galvanized steel plate electrode 600 X 600 X 6 mm thick buried directely in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level connected to GI earth wire 4mm as earthing lead by means of galvanized steel bolts,nuts check nuts and washers and other end connected with to Poles, Pannel board etc as directed including funnel, 20 mm bore, light grade galvanized iron pipe, wire mesh charcoal of coal dust and common salt in alternative layer all around the earth electrode compacted thickness 15cm with concrete pit in PCC 1:3:6 type C1 50 mm thick pre cast RCC 1:2:4 type B1 with 8mm dia cover slab set in CM (1:4) reinforcement with 8mm dia deformed bars @ 15 cm C/C and suitable handle of 10mm dia MS round bars, including earth work as required complete all as shown in electrical plate No. 5 of MES schedule Part I and testing complete all as specified and as directed.(Note: GI Earthing strip upto 7.5m in length is deemed to be included in the unit rate. The Strip required beyond 7.5m shall be measured and paid for separately) Please Enable Macros to View BoQ information |
| 47 | M&L in repair of earthing complete with galvanized steel plate electrode 600 X 600 X 6 mm thick buried directely in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level connected to GI earth wire 4mm as earthing lead by means of galvanized steel bolts,nuts check nuts and washers and other end connected with to Poles, Pannel board etc as directed including funnel, 20 mm bore, light grade galvanized iron pipe, wire mesh charcoal of coal dust and common salt in alternative layer all around the earth electrode compacted thickness 15cm with concrete pit in PCC 1:3:6 type C1 50 mm thick pre cast RCC 1:2:4 type B1 with 8mm dia cover slab set in CM (1:4) reinforcement with 8mm dia deformed bars @ 15 cm C/C and suitable handle of 10mm dia MS round bars, including earth work as required complete all as shown in electrical plate No. 5 of MES schedule Part I and testing complete all as specified and as directed.(Note: GI Earthing strip upto 7.5m in length is deemed to be included in the unit rate. The Strip required beyond 7.5m shall be measured and paid for separately) Please Enable Macros to View BoQ information |