| 1 | Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft / loose soil complete all as specified and directed. |
| 2 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m depth for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 sqm on plan and in soft /loose soil etc complete all as specified and directed. |
| 3 | Returning, filing in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil etc complete all as specified and directed |
| 4 | Removal of excavated materials (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting points etc complete all as specified and directed. |
| 5 | M&L for earth filling including spreading and levelling in layer not exceeding 25 cm thick including watering and well ramming complete all as specified and directed. |
| 6 | Removal of excavated materials (soil) exceeding 250 m but not exceeding 500 m and depositing where directed at a level not exceeding 1.5 m above the starting points etc complete all as specified and directed. |
| 7 | M&L for broken stone or boulders hardcore of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 8 | M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed. |
| 9 | M&L for providing precast cement concrete louvres and jallies 25 mm thick (measured solid) including all mouldings but excluding frame in cement concrete 1:2:4 type B0 using 12.5 mm graded stone aggregates and set in cement mortar 1:4 complete all as specified and directed. |
| 10 | M&L for RCC (nominal mix) 1:1.5:3 type A-1 using 20 mm graded stone aggregate as in slab supported on wall, beam and column in floors, roofs, landings, balconies, canopies and in shelves and similar work complete all as specified and directed. Note - Reinforcement and form work shall be measured and paid separately. |
| 11 | M&L for RCC (nominal mix) 1:2:4 type B0 using 12.5 mm graded stone aggregate as in beam, cantilevers, bressummers, lintels over 1.5 m span and similar work complete all as specified and directed. Note :- Reinforcement and form work shall be measured and paid separately. |
| 12 | M&L brick work using old size sub class 'B' bricks straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 13 | M&L for walling of squared rubble, regular coursed stone masonry well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and directed. |
| 14 | M&L 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including screed bed 15 mm thick in CM 1:4 complete all as specified & directed. |
| 15 | M&L for form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200 mm thick (horizontal or sloping) for rough finished flat surface of concrete complete all as specified and directed |
| 16 | M&L for form work to sides and soffits of floor or roof beam, beam hauchings, girders, bressummers, lintels, cantilevers, shelves, for flat rough finished concrete surfaces complete all as specified and directed. |
| 17 | M&L for form work to edges of concrete flats, treads breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roof and sides of bands in walls, horizontal or sloping and similar work for rough finished concrete surface exc 10 cm but not exc 20 cm wide complete all as specified and directed. |
| 18 | M&L for factory-made uPVC any colour fixed window made of extruded profiles with wall thickness of 2.3mm(±0.2mm). Window profile with hollow section with multi chamber. Frame (60mm x 58mm). T profile (one vertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc. making arrangement for fixing of hardware, EPDM gasket. 1.2 +- 0.2mm thick, galvanized steel Frame (28mm x 21.5mm), T profile (27mm x 17 mm) to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners- 5mm thick glazing with selected quality glass.Note: (i) Area exceeding 1.00 sqm but not exceeding 2.00 sqm each.(ii) The unit rate quoted by contractor include cost of glass and includes all other connected accessories. (iii) Net opening will be measured for payment purpose. |
| 19 | Supply and fixing factory-made uPVC door frame made of uPVC. extruded sections having an overall dimension (extruded section profile) 48x40 mm (tolerance ± 1 mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame Jointed with galvanized brackets and stainless-steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete all as specified by the manufacturer complete all as specified and directed. |
| 20 | Supply and fixing 30 mm thick factory made Polyvinyl Chloride (PVC) door shutter made of styles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2 mm (± 0.2 mm), with inbuilt decorative moulding edging on one side. The styles and rails mitred and jointed at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x30 mm and 2 mm ( + 0.2 mm) wall thickness fixed to the shutter styles by means of plastic/ galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multichambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as specified by the manufacturer complete all as specified and directed. |
| 21 | S&F factory made uPVC any colour sliding window, three track made of extruded profiles with wall thickness of 2.3mm (± 0.2mm), window profile with hollow section with multi chamber, frame (88mm x 52mm), sliding sash (42mm x 67mm), Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware, EPDM gasket, 1.2 ±0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware Touch Lock of zinc alloyed (white powder coated), steel roller system, Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories, for area not exceeding 2.00 sqm each complete as specified and directed.Note : (i) The unit rate quoted by contractor include cost of 5mm thick plain/frosted glass and all other connected accessories. (ii) Net Opening will be measured for payment purpose. |
| 22 | S&F in repair Galvanised mild steel wire cloth, 0.63 mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed. |
| 23 | M&L for auto close hinges, stainless steel, bright finish or electrogalvanised fixed complete all as specified and as directed. |
| 24 | S&F stainless steel handles, fancy type, of 150 mm size complete all as specified and directed.Make : Ebco / Hettich / Ultima / Hafele or equvalent make as approved by GE. |
| 25 | S&F 25 mm dia stainless steel, wood finish, fancy type, anti-rust curtain rod with wooden curtain bracket with finials etc. for doors / windows fixed by self screw in wall complete as all specified and directed. |
| 26 | M&L for mild steel TMT bar 10 mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 27 | M&L for mild steel TMT bar 5 mm dia and over upto and including 10mm dia as in stirrups, spacers & binders cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 28 | S&F rolled mild steel section as in joist, channel, angle or tee sections fixed independently ,with out connecting plates etc (cut to ordinary length i.e within 20 mm of the length indicated) of grade Fe 410-W (Gde E-250) quality A complete all as specified and directed |
| 29 | S&F rolled mild steel section as in plate girder or single stanchions, built up of one beam or channel section with flange plates, caps, bases. splices, angle brackets, cleats and other connections of grade Fe 410-W (Gde E-250) quality A complete all as specified and directed |
| 30 | S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed. |
| 31 | M&L for powder coated (minimum thickness of powder coating 50 micron) anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed. |
| 32 | S&F powder coated (thickness of powder coating not less than 50 micron) anodised aluminium window and ventilator shutters, side hung / sliding type without sash bars, aluminium sections weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws anodised aluminium fittings such as peg stays 150 mm long (1 No), hinges type B-21, 100 mm long (2 No) , suitable handle (1 No) complete all as specified and directed. |
| 33 | M&L for ceiling / roof tiles for Mangalore pattern tile roofing, laid dry in Gazibo complete all as specified and directed. |
| 34 | M&L for ridge or hip tiles to suit Mangalore pattern of roofing tiles, bedded and jointed in lime mortar 1:3 or cement mortar 1:6 complete all as specified and directed. |
| 35 | M&L for PVC insulated panels with Expanded Polystyrene (EPS) stuck of 1mm coloured / plain PVC sheet suitably placed in false ceiling with designer grit (15mm grit 08mm return) beveled tegular suprafine xl 15mm / silhouette complete including necessary hanging system arrangement 6 mm dia suspenders as per manufacture’s instruction which is required to be made from existing RCC roof / stone slab of building or steel framed structure complete all as specified and directed. Make : Armstrong (ANF RH 90) or equivalent make of Everest, Gypsum India Ltd, Bison and Aerolite. |
| 36 | M&L for 18-20 mm thick High Density high moisture resistant (HDHMR) board for kitchen cupboard / door shutter of make Action tesa / Pearlwood or equivalent make as approved by GE, one side colour / white laminate and other side decorative as in modular kitchen / cabinets / door shutter fixed with minifix hardware wherever required including edge band 22mm wide, 0.80mm thick of matching colour on exposed surfaces of board fixed with polymaster adhesive of REHAU make or equivalent including trimming edges of edge band to true line of thickness of board by manual trimmer, fixed to wall etc. complete all as specified and directed. |
| 37 | M&L for 10 to 12 mm thick, parking tiles matt finish / Glossy coloured tiles of design as approved, (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 38 | M&L for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed. |
| 39 | M&L for 100 mm thick cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate as in sub-floors, sub-bases, floors and paving, etc. complete all as specified and directed. |
| 40 | M&L for 75 mm thick PCC 1:3:6 type C2 using 40 mm graded stone aggregate, in plinth protection laid in panels and finished even and smooth without using extra cement including necessary form work complete all as specified and directed. |
| 41 | M&L for 75 mm thick Cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base complete all as specified and directed. |
| 42 | M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in sub base flooring 25 mm thick surface finished even and smooth with using extra cement complete all as specified and directed. |
| 43 | M&L for glazed ceramic coloured tiles in vertical surface 350x 250x 7 mm / 450X 350X 7 mm / 300x 600x7 mm / 450x 300x7 mm / 600x 1200x7 mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match surface of tiles over and including rendering 10 mm thick in CM 1:4 complete all as specified and directed. |
| 44 | M&L for joint free non skid coloured tiles of design as approved 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles over and including screed bed 15 mm thick in CM 1:6 complete all as specified and directed. |
| 45 | M&L for vitrified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished area of each tiles exceeding 0.42 sqm but not exceeding 1.0 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles over and including screed bed or bedding layer 15 mm thick in CM 1:6 complete all as specified and directed. |
| 46 | M&L for designer rubber moulded cement concrete tiles 25 cm x 25 cm x 22 to 25 mm thick set, jointed and pointed in neat cement slurry as in floors, cut and polished with grey cement and no pigments over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed. |
| 47 | M&L for providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3, including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed. |
| 48 | M&L for providing and laying 60 mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. |
| 49 | M&L for cutting opening in cement concrete walls (any description) for door, window and other openings (with or without reveals) or enlarging existing openings, including trimming surfaces to receive rendering, etc. complete all as specified and directed. |
| 50 | M&L for cutting channels grooves or rebates in un reinforced concrete exc 15 cm girth but n.exc 30 cm and trimming surface complete all as specified and directed. |
| 51 | M&L for rendering on fair faces of brick work or concrete surface of wall 15 mm thick in CM 1:6 and to be finished even and smooth with out using extra cement complete all as specified and directed. |
| 52 | M&L for rendering on stone masonry or other than fair faces of brick work of wall 15 mm thick in CM 1:6 and to be finished even and smooth with out using extra cement complete all as specified and directed. |
| 53 | M&L for rendering 10 mm thick in CM 1:3 on fair faces of brick or concrete surface of wall and finished even and smooth with out using extra cement complete all as specified and directed. |
| 54 | M&L for rendering on stone masonry or other than fair faces of brick work of wall 15 mm thick in CM 1:4 and to be finished even and smooth with out using extra cement complete all as specified and directed. |
| 55 | M&L for preparation of new surface of wall of any description and applying two coats of oil bound distemper (OBD) over a coat of alkali-resistant priming paint over and including 1 mm thick wall putty all as specified and directed. |
| 56 | M&L for complete removal of existing treatment and preparation of old surface of wall of any description and applying two coats of oil bound distemper (OBD) over a coat of primer and including 1 mm thick wall putty all as specified and directed. |
| 57 | M&L for complete removal of existing treatment and preparation of old surface of wall of any description with a coat of 1 mm thick wall putty and applying two coats of acrylic emulsion exterior grade weather proof paint over a coat of primer complete all as specified and directed.Make for Acrylic Emulsion Paint : Apex Ultima of Asian Paint / WeatherShield Max of Dulux / WeatherCoat Anti Dust of Berger or equivalent make as approved by GE.Note :- Acrylic Emulsion Paint shall be carried out as specified in clause 15.17 of SSR Part-I including all necessary arrangement such as scaffolding / working plateform for execution of work. |
| 58 | M&L for preparation of new surface of walls of any description with a coat of 2mm thick wall putty and applying two coats of acrylic emulsion exterior grade weather proof paint over a coat of primer complete all as specified and directed.Make for Acrylic Emulsion Paint : Apex Ultima of Asian Paint / WeatherShield Max of Dulux / WeatherCoat Anti Dust of Berger or equivalent make as approved by GE.Note :- Acrylic Emulsion Paint shall be carried out as specified in clause 15.17 of SSR Part-I including all necessary arrangement such as scaffolding / working plateform for execution of work. |
| 59 | S&F 12 mm thick frosted toughened glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes with channel, allied fittings & hand rail sliding as required in bath area complete all as specified and directed. |
| 60 | M&L for preparation of new or previously untreated surfaces of steel of any description, over 10cm in width or girth and apply two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 61 | S&F in repair for 15mm bore dia of pipe brass CP, single lever wash hand basin mixer for mixing hot & cold water screwed down for iron pipe including all accessories complete all as specified and directed.Make : Jaquar / Kohler / Grohe / Cera / Roca. |
| 62 | S&F in repair white rimless single piece EWC with UF soft close slim seat cover, Hinges, fixing accessories and accessories set and cistern fittings, S trap including fixing as per manufacturer instructions complete all as specified and as directed. Make : Jaquar / Kholer / Grohe / Roca / Cera. |
| 63 | M&L in repair for table top wash basins, of rectangular / square shape Vitreous China, white, flat back, excluding taps, waste, chain and plug and porcelain stopper but including PVC waste pipe minimum 600 mm long suitable for 32 / 40 mm dia of outlet complete all as specified and directed. |
| 64 | S&F in repair for 15mm bore, brass, Single Lever Wall Mixer 3-in-1 System with provision for both Hand Shower and Overhead Shower Complete with 115mm Long Bend Pipe, Connecting Legs & Wall Flange (without Hand & Overhead Shower) and including screwed down for iron pipe or for union along with spout complete all as specified and directed.Make:- Jaquar / Cera / Kohler / Roca. |
| 65 | S&F in repair brass chromium plated overhead shower rose of 250 X 250 mm size, square / round shape, with revolving / swivel joint complete all as specified and directed. Make : Jaquar / Kohler / Grohe / Roca / Cera. |
| 66 | S&F in repair health faucet (hand shower) chromium plated suitable for 15 mm dia pipe with 1.2 metre long flexible tube with non return valve and wall hook including making connections and fixed in position complete all as specified and directed.Make : Jaquar / Kohler / Grohe / Roca / Cera |
| 67 | S&F in repair hand shower round shape of 105mm dia, ABS (Acrylonitrile Butadiene Styrene) body with a chrome-plated finish, a face plate, multi-flow functionality, equipped with a cascade effect, with cleaning system for easy cleaning and including 1.5m long flexible chrome tube complete all as specified and directed.Make : Jaquar / Grohe / Kohler / Roca / Cera. |
| 68 | S&F in repair chromium plated towel rail 600 mm long of brass complete all as specified and directed. Make : Jaquar / Kohler / Grohe / Roca / Cera. |
| 69 | S&F in repair Stainless Steel Towel Rack 600mm Long complete all as specified and directed. Make : Jaquar / Kohler / Grohe / Roca / Cera. |
| 70 | S&F in repair chromium plated soap dish holder complete all as specified and directed. Make : Jaquar / Kohler / Grohe / Roca / Cera. |
| 71 | S&F in repair float corner glass shelve 8 mm thick 250 mm radius complete all as specified and directed.Make : Jaquar / Kohler / Grohe / Roca / Cera |
| 72 | S&F in repair chromium plated towel ring round (20cm dia) / square (20cm x20cm) shape (minimum weight 300gm) with round flange complete all as specified and directed. Make : Jaquar / Kohler / Grohe / Roca / Cera |
| 73 | M&L in repair for Tumbler Holder for bathroom complete all as specified and directed.Make : Jaquar / Kohler / Grohe / Roca / Cera |
| 74 | S&F in repair liquid Push Button Soap Dispenser of brass fixed with and including chromium plated brass screws complete all as specified and directed.Make : Jaquar / Kohler / Grohe / Roca / Cera |
| 75 | S&F in repair bib taps 2-in-1 cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule fancy type of 15 mm bore dia of pipe complete all as specified and directed. |
| 76 | S&F 30mm thick PUF (Polyurethane Foam) insulated sandwich panel with pre-coated GI Sheet not less than 0.5 mm thick on both sides, having a total density of not less than 40 Kg per cubic meter, including all necessary fixing arrangement complete all as specified and directed. |
| 77 | S&F rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) 1000 litre capacity hoisted and fixed in position complete all as specified and directed |
| 78 | M&L for providing circular, raised platform of height 20 cm below the tank and base dia 25 cm more than the external dia of PVC tank of 500/1000 liters using PCC 1:3:6 type C1 using 20 mm graded stone aggregate with smooth finish including necessary form work etc. complete all as specified and directed. |
| 79 | M&L for Double Wall Corrugated (DWC) pipe of class SN-4, IS-16098 (part-II) of 200mm bore (internal), laid to slope in trenches, jointed complete with coupler, bends, Tee, reducers etc and tested complete all as specified and directed.Make : Ultra plus of Supreme / Corfit of Prince / D-Rex of Astral or equivalent as approved by GE. |
| 80 | M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors of 75 mm bore of pipe etc complete all as specified and directed. |
| 81 | M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls of 110 mm bore of pipe etc complete all as specified and directed. |
| 82 | S&F PVC (SWR) bends any radius of 75 mm bore without access door complete all as specified and directed. |
| 83 | S&F PVC (SWR) bends any radius of 110 mm bore without access door complete all as specified and directed. |
| 84 | M&L PVC (SWR) vent cowl 75 mm complete all as specified and directed. |
| 85 | M&L PVC (SWR) floor trap of diameter of outlet 75 mm, plain with grating including jointing with solvent cement complete all as specified and directed |
| 86 | M&L PVC (SWR) gully trap 125/110 mm setting and jointing with solvent cement complete all as specified and directed |
| 87 | S&F GI tubes medium grade with all fittings fixed to walls and ceilings or laid in floors of 20 mm bore of pipe complete all as specified and directed. |
| 88 | S&F in repair bib taps cast copper alloy with crutch or butterfly handle, long body, screwed down, screwed for iron pipe or for brass ferrule fancy type chromium plated of 15 mm bore dia of pipe complete all as specified and directed. |
| 89 | S&F in repair ball brass valves, high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule of 15 mm bore of pipe complete all as specified and directed. |
| 90 | S&F in repair waste fittings, brass, chromium plated 32mm dia for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed. |
| 91 | S&F in repair ball valves for 20 mm bore dia of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 210 gms) complete all as specified and directed. |
| 92 | S&F in repair Stainless Steel Square Grating doom of 125 x 125 mm of Stainless Steel (minimum weight 150 gram), with or without waste hole, fixed on floor / nahani trap complete all as specified and directed. |
| 93 | S&F PVC connection 15 mm size bore with PTMT nuts of length 450 mm complete all as specified and directed. |
| 94 | M&L for cement concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid & tested for 200 mm bore of pipe with cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate complete all as specified and directed. |
| 95 | M&L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for 200/225 mm dia of pipe complete all as specified and directed. |
| 96 | S&F in repair looking mirror 5.5 mm thick of selected quality glass of size 600 x 450 mm bevelled edge , mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plug with chromium plated brass screw and cup washers including aluminium anodized frame complete all as specified and directed. |
| 97 | S&F in repair angle cock cast copper alloy for 15 mm bore dia of pipe screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union complete all as specified and directed. |
| 98 | M&L in repair toilet paper holder of brass, chromium plated fixed to walls with chromium plated (CP) brass screws complete all as specified and directed. |
| 99 | Taking down carefully by unscrewing from boards / outlet boxes, fittings and fixtures such as LED light and fittings etc. for reuse at site or carrying to the store and fixing the same old LED lights fitting with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Note : This item shall be measured only when found serviceable in all respects complete for reuse. |
| 100 | S&F sheet metal enclosure factory fabricated for MCB distribution board SPN double door type concealed in wall 240 Volt 16 way IP-42 protection with 200 amp rated bus bar complete all as specified and directed. |
| 101 | S&F ceiling rose 3 phase, PVC / polycarbonate, isolated body complete all as specified and directed. |
| 102 | S&F LED fixtures 10 Watt with extruded polycarbonate, environmental friendly, slim design with decorative and caps, high performance diffuser for soft & glare free light, minimum lumen output 1900 lm with efficacy 110 lm/w, driver with high voltage protection upto 380 V AC & surge protection upto 2.5 KV, CCT(K)-6500, LM 80 tested high brightness LED technology complete all as specified and directed.Make : Havells Cat Part No. LHEXACP7IN1W010 or equivalent model of Wipro / Crompton / Philips as approved by GE. |
| 103 | S&F LED luminaire 600 mm x 600 mm, 24 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 104 | S&F nucleus recessed mounting adjustable COB LED downlight, 25 Watt , made of aluminium fins and high-lumen LED a light source with clear diffuser and separate electronic driver complete adjusted as per requirement including fixing with clamps, connecting complete all as specified and directed. Please Enable Macros to View BoQ information |
| 105 | S&F nucleus recessed mounting adjustable COB LED downlight, 25 Watt , made of aluminium fins and high-lumen LED a light source with clear diffuser and separate electronic driver complete adjusted as per requirement including fixing with clamps, connecting complete all as specified and directed. Please Enable Macros to View BoQ information |