| Sl. No. | Item Description |
| 1 | Dismantling patent stone floor including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 2 | Providing 50mm thick 2nd class patent stone flooring (1:2:4) with 20mm, to 6mm size graded stone chips finished with flooring coat of neat cement in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royality with all complete as per building specification and direction of E/I. |
| 3 | Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3 mm thick. |
| 4 | Providing 19mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 5 | Dismantling old plaster and pointing in cement or lime and raking out joints to 15mm depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 6 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 7 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 8 | Providing 6mm cement plaster (1:4) in celling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 9 | Providing 12mm cement plaster (1:4) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.. |
| 10 | Providing and fixing fan hook of 16mm dia TMT M.S. bar 1 meter long bent to required size and shape placed in position and fixed in R.C.C. slab/beam at the time of casting all complete as per building specification and direction of E/I. |
| 11 | Supplying, Fitting and fixing M.S grill made of 20 x 6mm M.S. flat as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, hoisting carriage of grill to work site hoisting as per building specification and direction of E/I. |
| 12 | Supplying, fitting and fixing collapsible gate of approved size and make properly fabricated with vertical double channels 20 x 10 x 2mm at 100mm centers and braced with M.S. flat diagonals 20 x 3mm with top and bottom rails of T.iron 40 x 40 x 6mm with 38mm dia steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of red lead paint, car riage, hoisting and taxes all complete as per buildings pecification and direction of E/I. |
| 13 | Supplying, fitting and fixing 20 gauge G.C.I. sheet gate fitted on. M.S. angle frame of size 60 x 60 x 6mm -do- -do- all complete as per specification & direction of E/I. |
| 14 | Extra for cleaning the whole surface by scrapping the entire old white wash, colour wash including the cost of scafolding complete as per specification & direction of E/I. |
| 15 | Providing two coats of synthetic enamel paint over steel surface -do- -do- all complete as per specification & direction of E/I. |
| 16 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 17 | Providing and laying Double charge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 / ISO 13006 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm . |
| 18 | Providing TMT steel reinforcement 8mm, 10mm, 12mm & 16mm dia bars as per approved design and drawing excluding carriage of M.S bar to work site, cutting, bending end binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per building specification and direction of E/I.B.C.D. S.O.R. Item No. 5.5.4 : 8mm dia Bar - |
| 19 | B.C.D. S.O.R. Item No. 5.5.5 (a) : 10mm dia Bar - |
| 20 | B.C.D. S.O.R. Item No. 5.5.5 (b) : 12mm & above dia Bar - |
| 21 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 22 | Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty where required, scaffolding, washing of floors and taxes all complete as per specification and direction of E/I. |
| 23 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm). |
| 24 | Making plinth protection 50mm thick of cement concrete 1:3:6 over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 25 | Providing 150mm wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 125mm apron including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. |
| 26 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.20mm dia D.S.R. Item No. 18.8 |
| 27 | 15mm dia D.S.R. Item No. 18.9 |
| 28 | Providing and fixing male ended bib cock of approved quality (wt. not less than 350 gms.) with extra socket all complete as per specification and direction of E/I.15mm dia Brass Bib Cock |
| 29 | Providing and fixing brass/C.I. stop cock of approved quality as per specification and direction of E/I.Brass stop cock - 15mm dia |
| 30 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 31 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) 110mm dia Single socketed pipes.D.S.R. Item No. 12.41.1 75mm |
| 32 | D.S.R. Item No. 12.41.2 110mm |
| 33 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Single tee with door - 75mm D.S.R. Item No. 12.42.3.1 |
| 34 | Single tee with door - 110mm D.S.R. Item No. 12.42.3.2 |
| 35 | Bend 87.5° - 75mm D.S.R. Item No. 12.42.5.1 |
| 36 | Bend 87.5° - 110mm D.S.R. Item No. 12.42.5.2 |
| 37 | Shoe (Plain) - 75mm D.S.R. Item No. 12.42.6.1 |
| 38 | Shoe (Plain) - 110mm D.S.R. Item No. 12.42.6.2 |
| 39 | Supplying, fitting and fixing viterous white glazed earthen ware I.W.C of Parry Hindustan or any other I.S.S approved make with 100mm H.C.I \\"p\\" trap 15 liters C.I. or C. pull and let go flushing cistern of names or other I.S.S equivalent make, complete with all fittings. C.I or C.C brackets 32mm alkathene/P.V.C telescopic flush, pipe about 2M long with one brass coupling and clamps G.I chain and pull including supplying and fixing a pair of viterous white glazed earthenware where footrest to be fixed in floor 15 mm C.I body brass spindle stope cock of weight not less than 50 grins. 15 mm P.V.C connection pipe 450mm long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/I.580mm long with 12.5 litre low level P.V.C. cistern |
| 40 | Supplying, fitting and fitting vitreous white glazed earthen ware wash hand basin of Parry or Hindustan or any other I.S.S. approved make supported on pointed C.I. or M.S. brackets 32m C.I. brass waste, 15mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350 grams, 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/I. |
| 41 | EARTH WORK IN EXCAVATION IN FOUNDATION Trenches in ordinary soil (vide classification of soil item -A) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I. |
| 42 | Providing coarse clean SAND IN FILLING in foundation trenches or in plinth including ramming and watering in layer not exceeding 150 mm thick with all leads and 1.5 M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer Incharge (Mode of measurement compacted volume) |
| 43 | Providing designation 75-B, BRICK FLAT SOLING joints filled with local sand including cost of watering,taxes and royalty all complete as per building specification and direction of Engineer Incharge |
| 44 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stoneaggregate 20 mm nominal size) |
| 45 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 46 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stoneaggregate 20 mm nominal size) |
| 47 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 48 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 49 | Centering and shuttering including struting, propping etc. and removal of form for -Foundation, footings, bases of columns etc. |
| 50 | Centering and shuttering including struting, propping etc. and removal of form for -Columns |
| 51 | Centering and shuttering including struting, propping etc. and removal of form for -ROOF SLAB |
| 52 | Centering and shuttering including struting, propping etc. and removal of form for -Beams, plinth beams,- |
| 53 | Providing tor steel reinforcement TMT FE 500 of following dia. rods as per approved design and drawing including carriage of bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction and direction of E/I.(ONLY VALID FOR SAIL & TATA STEEL, JSPL, ELECTRO STEEL LTD. AND VIZAG STEEL)TOR 8 MMDIA. |
| 54 | TOR 10 MMDIA. |
| 55 | TOR 12 -32 MM DIA. |
| 56 | Providing designation 75B brick work in C.M. (1:6) in foundation & plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm. thick mortar joints,cost of screening materials raking out joints to 15mm depth , curing, taxes & royalty all complete as per building specification & direction of E/I. |
| 57 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 20mm nominal size) |
| 58 | Providing designation 75 B BRICK WORK in CM. (1:6) in SUPERSTRUCTURE with approved quality of clean coarse & of F.M. 2.5 including providing 10mm thick mortar joints cost of screening,racking out joints to 15 mm depth,curing, taxes and royalty all complete as per building specification and direction of Engineer Incharge |
| 59 | Providing 12 mm Thk. cement plaster(1:6) on inside walls with clean course sand of FM-1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I |
| 60 | Providing 6mm cement plaster(1:4) in ceiling with clean course sand of FM-1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I |
| 61 | Providing 12 mm thick water proof CEMENT PLASTER (1:4)on outside wall with clean coarse sand of F.M.1.5 and waterproofing compound (as per specified and approved) including cost of screening, curing making grooves with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I. (Cost of waterproofing compound will be paid separately) |
| 62 | Providing and laying Double charge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 / ISO 13006 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm .B.C.D. S.O.R. Item No. 5.6.28 |
| 63 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.D.S.R. Item No. 8.31 |
| 64 | Supplying, fitting and fixing M.S. 40x40x6 mm , IS2062 Grade A M.S. angle, hoistingin steps, welded with 6mm dia and 75 mm long M.S. rods, anchorage fixed in concrete steps at the time of casting, including taxes all complete as per direction of E/I. |
| 65 | Supplying fitting and fixing 20 guage G.C.I. sheet gate fitted on M.S. Angle frame of size 60x60x6 mm including cost of fabrication. |
| 66 | Supplying, fitting & fixing M.S. GRILL made of 20 x 6 mm flat as per approved design and drawing properly fabricated with joints continuous fitted, welded and finished smooth, hoisting as per building specification and direction of E/I. |
| 67 | Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I |
| 68 | Finishing walls with Premium Acrylic Smooth exterior paint with silicone additives \\"Snowcryl - XT\\" of M/S Snowcem India Ltd, or equivalent of required shade.New work (Two or more coats applied @1.43 ltr / 10sqm. Over and including base coat of water proofing cement paint Snowcem Plus or equivalent applied @ 2.20 kg./10 sq.m. ) |
| 69 | Providing Primer one coat of read lead paint of approved make over new STEEL SURFACE preparing the surface after cleaning, removing rust, dirt, scales, smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. |
| 70 | Providing 2 coats of SYNTHETIC ENAMEL PAINT of approved shade and make over STEEL SURFACE grills & railings including cleaning the surface thoroughly scaffolding and taxes all complete as per building specification and direction of E/I. |
| 71 | Providing and laying 80mm th. factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction and of approved size and design/ shape laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with coarse sand etc. all complete as per the direction of E/I.. |
| 72 | Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 m including all lifts, levelling , ramming the foundation trenches, removing roots of trees, serbs all complete as per approved design,building specification & direction of E/I. |
| 73 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including' cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/l (Mode of measurement complacted volume). |
| 74 | Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l. |
| 75 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All wrk up to plinth level : 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)In Foundation |
| 76 | Providiag designation 75B brick work in Cement Mortar (1:6) in foudation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing taxes and royalty all complete job as per building specificition and direction of E/l. |
| 77 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 78 | Providing 12 mm thick cement plaster (1:4) with clean coarse sand of F.M. 1.5 with 1.5 mm cement punning including screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per specification and direcition of E/l. |
| 79 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size). |
| 80 | Providing Tor steel reinforcement of 8mm. dia. rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. TMT Fe 500 ( Only valid for SAIL / TATA steel ) |
| 81 | Cost of Driling 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site.(a) From 0.00 M to 50.00 M below G.L. |
| 82 | (b) From 51.0 M to 150.00 M |
| 83 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.200 mm nominal size dia |
| 84 | Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by \\"V\\" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge |
| 85 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:200 mm dia |
| 86 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.200 mm clamp |
| 87 | Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump. Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages 2 HP |
| 88 | crompton 2 HP Starters Control Panel for Submersible Pump |
| 89 | FR PVC Insulated 3 Core 4 Sqmm copper wire |
| 90 | GI Pipes ( Tata Mark or Equivalent ) as per IS -1239 ( Part -01) 2004 ISI Marked / Medium Quality 40 mm dia |
| 91 | Point wiring in PVC conduit, with modular type switch - Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm. FR PVC insulated copper conductor single cable in surface/recessed PVC conduit, with modular type switch, modular plate, suitable size G.I. box etc. as required. Group B |
| 92 | Twin control point wiring in PVC conduit, with modular type switch - Wiring for twin control light point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, 2 way with modular switch, modular plate, suitable size G.I. box etc. as required. |
| 93 | Power plug wiring in PVC conduit (2 x 4 sq.mm) - Wiring for light/power plug with 2 x 4 sq.mm. FR PVC insulated copper conductor single core cable in surface recessed PVC conduit, along with 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. |
| 94 | Circuit/submain wiring in PVC conduit - Wiring for Circuit/submain wiring along with earth wire the following sizes of FR PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required.2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. earth wire |
| 95 | 2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. earth wire |
| 96 | 2 x 6.0 sq.mm. + 1 x 6.0 sq.mm. earth wire |
| 97 | S/F Call bell buzzer - Supplying and fixing call bell/buzzer suitable for D.C./A.C. single phase, 230 volts, complete as required. |
| 98 | S/F light plug point with modular type accessories - Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch connection, painting etc. as required . (For light plugs to be used in non residential buildings) |
| 99 | S/F power plug point with Modular type accessories - Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface of in recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular switch connection, painting etc. as required. (For light plugs to be used in non residential buildings) |
| 100 | S/F 20 amps SPN MCB industrial socket outlet - Supplying and fixing 20 amps volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 amps 'C' curve, SP MCB, in sheet steel enclosure, on surface or in recess with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. |
| 101 | S/F PVC conduit - Supplying and fixing of following sizes of PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case recessed conduit as required.20mm |
| 102 | S/F Modular type switch socket - Supplying and fixing following modular switch/socket on the existing modular plate and switch box including connection but excluding modular plate etc. as required5/6 amps, one way switch |
| 103 | 5/6 amps, 3 pin socket outlet |
| 104 | S/F Modular boxes, base & cover plate - Supplying and fixing following size/modules G.I. box along with modular base & cover plate for modular switches in recess etc. as required.1 or 2 module (78mm x 78mm x 45mm) |
| 105 | S/F Modualr type blanking plate - Supplying and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required. |
| 106 | Copper earth plate elecrtode - Earthing with copper earth plate 600mmx 600mm x 3mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required (with charcoal or coke and salt) |
| 107 | S/L 8 SWG copper wire in ground - Supplying and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc. as required |
| 108 | P/F 25mmx 5mm G.I. earth strip in ground - Providing and fixing 25mm x 5mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 109 | P/F G.I. lightning conductor finial - Providing and fixing of lightning conductor finial, made of 25mm dia 300mm long, G.I. tube, having single prong at top, with 85mm dia 3mm thick G.I. base plate including holes etc. complete as required. |
| 110 | Reverting, sweating and soldering lightning conductor tape - Reverting, sweating and soldering of copper/G.I. tape (with another copper/G.I. base of the final or any other metalic object) as required. |
| 111 | Fixing lightning conductor tape in vertical run - Fixing of copper/G.I. tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor as required. (For vertical run) |
| 112 | P/F Testing joint G.I. lightning conductor - Providing and fixing testing joint, made of 20mm x 3mm thick G.I. strip, 125mm long, with 4 nos. of G.I. bolts, nuts, check nuts and spring washers etc. complete as required. |
| 113 | P/F G.I. earth tape for lightning conductor - Providing and laying G.I. tape 32mm x 6mm from earth electrode directly in ground as required. |
| 114 | ITC exhaust fan upto 450 mm sweep - Installation of exhaust fan upto 450mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning etc. as required. |
| 115 | 12\\" (300mm) metal exhaust fan |
| 116 | S/F Modular type electronic fan regulator -Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 117 | Supply, Installation, Testing and Commissioning of following size fan 3 Blades confirming to IS:374:2019 including wiring the down rods of stranded for 230 V 50 Hz, single phase supply etc. complete as requiredSupplying and fixing of 48\\" (1200mm) Ceiling Fan |
| 118 | S.I.T.C. of following rating surface mounted LED tube light fitting suitable for 230V 50Hz, single phase supply etc. complete as required.20/22 W LED Tube light |
| 119 | 15/16 Watt Led Bulb |
| 120 | MV cable laying upto 95 sq.mm. in ground - Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 35 sq.mm. but not exceeding 95 sq.mm. direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. |
| 121 | S/F rewireable double pole/TP&N switch disconnector - Providing and fixing following DP/TP&N sheet metal switch disconnector fuse unit in the existing metal board with rewireable type fuses, including drilling holes in metal board, making connections, etc as required.100 amps, TP&N |
| 122 | S/F MCCB in cubical panel board - Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubical panel board, including drilling holes in cubical panel, making connection, etc. as required.25-100 amps, 16 KA, fixed thermal setting |
| 123 | S/F 'B' series, S.P. MCB -Supplying and fixing 6 amps to 32 amps rating, 240 volts, 10 KA, 'B' curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commossioning etc. as required6/32 amps, single pole \\"B\\" series |
| 124 | 40 amps, single pole \\"B\\" series |
| 125 | CARRIAGE of Materials(i) Cement |
| 126 | (ii) Sand |
| 127 | (iii) Bricks |
| 128 | (iv) Steel |
| 129 | (v) Stone Chips |
| 130 | (vi) Paver Block |
| 131 | GST @ 18 % |
| 132 | Labour cess @ 1% Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail