| 1 | Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material all lead and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A- 1/259) All Lift |
| 2 | Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material all lead and lifts as below, stacking as directed by Engineer-in- charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-4/259) All lift |
| 3 | Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum) Spec. No. - Bd E /1 Page No. 287 and B-7, Page No. 38 2) In PCC M-150 |
| 4 | Providing and laying in situ Cement Concrete of trap/ granite / quartzite / gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) In RCC M-300 |
| 5 | Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) Slabs / Landings / Vertical Walls / Waist Slabs / Steps for Staircase 4) In RCC M-300 |
| 6 | Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (Bd-F- 17/306) Tor Steel |
| 7 | CI PIPES Providing and supplying ISI standard M S s pecials of required thickness with 3 coats of approved make epoxy paint (Shalimar, Ciba or Mahindra & Mahindra make) from inside and outside excluding all statutory duties & taxes such as GST levied by GOI & GOM in all respect, inspection charges, transportation to stores / site, and stacking, etc. complete. 5) Plain ended specials or plain ended branch flanged specials of all diameters. |
| 8 | Lowering, laying in position to correct line and level including M. S. pipes with / without any outcoating on pedestals or chairs upon prepared formation. The rate to include loading, unloading, hoisting, marginal cutting wherever required, assembling and tack welding, and transportation with lead. etc. completed as specified. 5 mm to 8 mm thick ii)) Above 250 mm. Upto 500 mm. dia. |
| 9 | Welding in all positions with required number of runs, for M. S. pipes internally and / or externally including gauging wherever necessary, fixing appurtenances and other accessories in connection with pipe laying work as per specification. 6 mm. |
| 10 | Providing and supplying at site of ductile iron / spheroidal graphite (S.G.) iron D/F non- rising spindle resil-ient seated glandless sluice valves with handwheel &without bypass arrangement. Valves in accordance with BS 5163 of PN-10/ 16 rated, with body and bonnet of ductile iron confirming to IS 1865 Gr. 500/7 or Gr.400/15. Wedge fully encapsulated WRAS approved EPDM rubber (approved for drinking water), Wedge nut of brass,shaft of stainless steel 1.4021/1.4104, stem seals min. 3 nos. of NBR, internal fasteners of stainless steel A2. Body& Bonnet coated inside & outside with electrostatically applied epoxy powder coated blue colour (suitable for drinking water) as per DIN 30677- 2 & GSK guidelines with a coating thickness of min. 250 microns. Valves should be full bore & tight shut-off. Flange drilling as per IS 1538 raised face & pressure testing at manufactures works shall be done as per IS 14846. including transportation charges excluding GST levied by GOI & GOM in all respect etc. complete. (For PN 10 & 16)100 mm. |
| 11 | Providing and supplying Tube settler including the tube / plates structure , and providing with new Z Tube settler modules made up of plasticised PVC tubes having size 55 mm x 55 mm including transportation to the site of work , erection on either sides manually or by mechanical means etc complete. (rates Excluding GST) |
| 12 | Dosing system for PAC , Poly-electrolyte and chlorine dioxide dosing along with preparation, agitation, dosing pumps, etc valves, piping, etc complete (Rates excluding GST). |
| 13 | Providing and Applying ACPRS PLCR SYSTEM PRIMER followed by ACPRS PLCR SYSTEM finish coat to the internal surface having two component system non toxic, solvent free, low VOC, safe for contact of potable water and food stuff when applied on exposed concrete / steel surfaces. Manufacturer should have the Dakks certification as well as ISO 9001:2015 accredited for manufacturing and formulation.(Rates Excluding GST) |
| 14 | Providing and applying QDPU coating with air driven spary application along with air assisted power mixer on inside outside surface of MS pipeline of 300 mm diameter including surface preparation, primer, and required thickness complete as per specification. |
| 15 | Providing and installing submercible pump having flow rate 30 m3/hr and 50 mtr head to recycle water from recycle plant to settled water channel. |
| 16 | Control panel for clear water pumping to settled water Channel - Providing and installing Control Panel to control pumps with cabling inside panel for pumps. Item includes contactors, volt and Amp meter, earthing etc . Incoming cable will be provided by MIDC to this control panel. |
| 17 | Supplying & erecting Recycle Pumps 50 m3/hr slurry pump (submersible type) with 18mtr head ss impeller CI body-one for slurry, one for recycle tank to Sludge bed tank. Rate excluding GS |
| 18 | Approval to RCC Designs and Drawing of Consultancy Services Cost Please Enable Macros to View BoQ information |