| 1 | Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required. SP No. As directed by Engineer-in-charge |
| 2 | Providing and applying priming coat over new wood and wood based surfaces, including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter, sand papering and knotting, scaffolding etc. complete. SP No. As directed by Engineer-in-charge |
| 3 | Providing and applying priming coat over new/old steel and other metal surfaces including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and scoured with wire brushes, fine steel wool, scrappers and sand paper, scaffolding etc. complete. SP No. As directed by Engineer-in-charge |
| 4 | Providing & applying washable oil-bound distemper of approved colour and shade to old & new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) complete. Spec.No.Bd.p.5 Page No.413 |
| 5 | Providing and applying plastic emulsion paint of approved quality, colour and shade to old and new surfaces in two coats including scaffolding, preparing the surface. (excluding the primer coat)etc. complete. Spec.No.Bd.P.6 Page One Number 414 |
| 6 | Providing and applying Royale Luxury Emulsion of approved make on internal wall surface as detailed below Scrapping for surface with emery paper and wipe clean for area. wall primer with brush by adding mineral turpentine oil by 8 to 10 % or water by 15 to 20% allowing to dry for 6 to 8 hoursAfter applying acrylic wall putty with appropriate proportion of water of allow to dry for period of 4 to 6 hours of activity. Scrapping with emery paper and wipe clean Applying paints Royale Luxury emulsion 1st coat with brush water content water 40 to 45% or 65 to 70% by role Applying paints Royale luxury emulsion 2nd coat with brush with water content 40 to 45% or 65 to 70 % by roller. (With prior approval of S.E.) |
| 7 | Providing and applying two coats of synthetic enamel paint of approved colour to new /old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) SP No.Bd. 0.5 page No. 405 |
| 8 | Providing and applying two coats of Flat oil paint of approved colour & shade to Internal / External plastered surfaces including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) comp. SP No.Bd.O 7 page No. 406 |
| 9 | Providing and applying pearl/ luster finish paint of approved colour and shade to the existing plaster surface including scaffolding, preparing the surface, applying the acrylic wall putti etc. complete. SP No. As directed by Engineer-in-charge |
| 10 | Providing and applying French polishing for required finish on previously wood including kontting preparing the surface ,scaffolding, etc. complete.as directed Spec: BDN 1.3 Pg .no. 399 |
| 11 | Providing and applying Melamine polish of required finish to the wood eork by spray machine including kontting preparing the even surfaces by scrapping appying french polishing ,scaffolding if required etc. complete as directed SP No. As directed by Engineer-in-charge |
| 12 | Providing and Applying PU polishing required finish to the wood eork by spray machine including kontting preparing the even surfaces by scrapping appying french polishing ,scaffolding if required etc. complete as directed SP No. As directed by Engineer-in-charge |
| 13 | Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface ,applying primer coat ,scaffolding if necessary, and watering the surface for two days etc complete. NOTE: For Item One Number 15 to 18 prior approval of Superintending Engineer will be necessary Spec No.As directed by Engineer in charge. |
| 14 | Providing and filling crack filling material to cosealed existing crack at any location by Dr. Fixit crack filler as per specification stipulated by manufactures & As directed by Engineer-in-charge etc.complete.(Need prior approval of Engineer incharge before execution of this item ) SP No. As directed by Engineer-in-charge |
| 15 | Providing internal cement plaster 12 mm thick in a single coats in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing complete. Spec. No.: Bd. L.2 Page No.368 |
| 16 | Providing internal cement plaster 20mm thick in two coats in cement mortar 1:4 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing complete. Spec. No.: Bd.L.4 Page No. 368 |
| 17 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. Spec. No.: Bd.L.7 Page No. 369 |
| 18 | Providing and applying gypsum plaster ( with Gypsum material ) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface / or on newly brick surface ( Excluding rough cast plaster ) in all position including preparing and Finishing the surface scaffolding etc.complete. |
| 19 | Providing and applying Two coats of wall care/acrylic Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete. |
| 20 | Removing the existing cement plaster of any thickness without causing dust nuisance and stacking the debris upto a distance of 50 metres or spreading in the compound and cleaning the site etc.complete. |
| 21 | Unskilled heavy male labour SP No. As directed by Engineer-in-charge |
| 22 | Material shifting by truck |
| 23 | Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, including fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs. for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. |
| 24 | Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. As directed by Engineer in charge. |
| 25 | Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete. As directed by Engineer in charge. Please Enable Macros to View BoQ information |