| 1 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. in any type of soil n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and as directed. |
| 2 | Returning, filling in soils as in trenches, including spreading, levelling, watering and well ramming in layers as in any type of soil, not exceeding 25cm thick complete all as specified and as directed |
| 3 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed. |
| 4 | Supplying, laying, jointing and testing LT underground electric cable XLPE insulated, PVC sheathed, armoured heavy duty 1100 volts grade cross section area 25 Sqmm 4 Core aluminium conductor laid in trenches/ducts or passing through pipes under road or fixed to poles complete all as specified and as directed, with and including taking up or down old damaged electric cable and removing from site of work, complete all as directed. |
| 5 | Supplying, laying, jointing and testing LT underground electric cable XLPE insulated, PVC sheathed, armoured heavy duty 1100 volts grade cross section area 16 Sqmm 4 Core aluminium conductor laid in trenches/ducts or passing through pipes under road or fixed to poles complete all as specified and as directed, with and including taking up or down old damaged electric cable and removing from site of work, complete all as directed. |
| 6 | Supplying, laying, jointing and testing LT underground electric cable XLPE insulated, PVC sheathed, armoured heavy duty 1100 volts grade cross section area 10 Sqmm 4 Core aluminium conductor laid in trenches/ducts or passing through pipes under road or fixed to poles complete all as specified and as directed, with and including taking up or down old damaged electric cable and removing from site of work, complete all as directed. |
| 7 | Supply and lay Double wall corrugated HDPE duct pipe of 50mm outer dia conforming to IS:14930 Pt-II with antirodant and non flame propergating properties of make and colour as approved by Engineer-in-Charge with fittings as protection to cable, laid in tranches or fixed to poles/walls complete with and including taking up/ down old damaged pipe and removing from site of work complete all as specified and as directed. |
| 8 | Supply and fixing as in replacement LED Solar street light fitting, 25 Watt with handheld remote controlling system including galvanized bracket with two No of clamps upto 1.5m (as per manufacturer's instruction) including a built-in solar panel, lithium ferro phosphate (LiFePO4) Battery, charge controller and motion sensor (PIR type) including taking down existing unserviceable solar street light fitting of any description complete all as specified and directed by Engineer-in-Charge. |
| 9 | Supply and fixing as in replacement LED Solar street light fitting, 40 Watt with handheld remote controlling system including galvanized bracket with two No of clamps upto 1.5m (as per manufacturer's instruction including a built-in solar panel, lithium ferro phosphate (LiFePO4) Battery, charge controller and motion sensor (PIR type) including taking down existing unserviceable solar street light fitting of any description complete all as specified and directed by Engineer-in-Charge. |
| 10 | Supply and fixing as in replacement LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66, protection, with impact and corrosion resistant,complete with driver and lamp all as specified and as directed. |
| 11 | Supply and fixing as in replacement LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66, protection, with impact and corrosion resistant,complete with driver and lamp all as specified and as directed. |
| 12 | Supply and fixing as in replacement 120W LED floodlight shall be a commercial-grade luminaire with a system wattage of 120 watts providing a luminaire efficiency of minimum 120 lm/W. It shall have a correlated color temperature of 5700K and a Color Rendering Index (CRI) greater than or equal 80. The fitting must maintain lumen output for at least 50,000 hours and operate efficiently within a temperature range of -10°C to +50°C. It shall be equipped with toughened glass and a secondary lens offering a beam angle of 120 degrees.The input voltage shall be in the range of 120 to 277 VAC, with a system current of 1.86 amps at 240V, and operate at 50 Hz frequency. The light shall incorporate SPD protection of 5kV and 10kV and conform to Ingress Protection level IP66, complete all as of directed. |
| 13 | Supply and fixing as in replacement 150W LED floodlight shall also be a commercial luminaire with a luminaire efficiency of minimum 120 lm/W and above. It shall feature a correlated color temperature of 5700K and CRI > or = 80, with lumen maintenance for 50,000 hours. It shall function properly in the temperature range of -10°C to +50°C, with toughened glass and a 120-degree secondary lens beam angle.The voltage input shall be 120–277 VAC, drawing 1.86 amps at 240V, and the system frequency shall be 50 Hz. Surge protection of 5kV and 10kV shall be included. The ingress protection rating shall be IP66, complete all as of directed |
| 14 | Supply and fixing as in replacement 250W LED floodlight shall also be a commercial luminaire with a luminaire efficiency of minimum 120 lm/W and above. It shall feature a correlated color temperature of 5700K and CRI > or = 80, with lumen maintenance for 50,000 hours. It shall function properly in the temperature range of -10°C to +50°C, with toughened glass and a 120-degree secondary lens beam angle.The voltage input shall be 120–277 VAC, drawing 1.86 amps at 240V, and the system frequency shall be 50 Hz. Surge protection of 5kV and 10kV shall be included. The ingress protection rating shall be IP66, and the product shall carry a minimum replacement warranty of 2 years, complete all as of directed. |
| 15 | Supply and fixing as in replacement post top lantern LED type 20 watt (cool white) 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed. |
| 16 | Supply and fixing as in replacement post top lantern LED type 20 watt (warm white) 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed. |
| 17 | Supply and fixing as in replacement post top lantern LED type 40 watt (cool white) 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed. |
| 18 | Supply and fixing as in replacement post top lantern LED type 40 watt (warm white) 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed. |
| 19 | Supply and fixing as in replacement LED spike light of 12 Watt (Red colour) outdoor type , IP 66 with high efficiency reflector make it ideal for lighting up including all connections all as specified and as directed. |
| 20 | Supply and fixing as in replacement LED spike light of 12 Watt (Green colour) outdoor type , IP 66 with high efficiency reflector make it ideal for lighting up including all connections all as specified and as directed. |
| 21 | Supply and fixing as in replacement LED spike light of 12 Watt (Blue colour) outdoor type , IP 66 with high efficiency reflector make it ideal for lighting up including all connections all as specified and as directed. |
| 22 | Supply and fixing as in replacement LED spike light of 12 Watt (Warm colour) outdoor type , IP 66 with high efficiency reflector make it ideal for lighting up including all connections all as specified and as directed. |
| 23 | Supply and fixing as in replacement LED Bollard type garden light 10 watt (Cool white) capacity and 800mm height, decorative and cylindrical shape LED bollard light with integrated driver, soft and comfortable uniform light distribution with opal diffusar & aluminium reflector complete with fixing bolts/ nuts & all accessories/ fitting complete all as specified and directed. |
| 24 | Supply and fixing as in replacement LED Bollard type garden light 10 watt (Warm white) capacity and 800mm height, decorative and cylindrical shape LED bollard light with integrated driver, soft and comfortable uniform light distribution with opal diffusar & aluminium reflector complete with fixing bolts/ nuts & all accessories/ fitting complete all as specified and directed. |
| 25 | Supply and fixing as in replacement dome type globe light 08 inch diameter with polycarbonate diffuser or milky white with B-22 holder and LED warm white bulb of 14 Watt, for fixing arrangement on pole/ pipe complete all as specified & as directed. |
| 26 | Supply and fixing as in replacement dome type globe light 16 inch diameter with polycarbonate diffuser or milky white with B-22 holder and LED warm white bulb of 14 Watt, for fixing arrangement on pole/ pipe complete all as specified & as directed. |
| 27 | Supply and fixing as in replacement SMC(Sheet Moulded Compound) outdoor type junction box of size 200mm x 140mm x 95mm (Outside Dimensions) with 63Amps rated four pole connector, one single pole MCB of 6-20 Amps rating mounted on DIN rail, stainless steel cable glands of suitable size for incoming and outgoing cables including fixing on steel tubular poles / PCC poles with 25mm x 4mm MS clamps (02 Nos), nuts & bolts etc complete all as specified and as directed by Engineer-in-charge. |
| 28 | Supply and fixing as in replacement Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal type for garden lights complete all specified and as directed. |
| 29 | Supply and fixing as in replacement PVC rectangular block for mounting switches, sockets etc with 3mm thick plastic laminated sheet cover, MS screw, washers etc of size (100 x 100 x 50 mm) suitable for garden lights complete all specified and as directed. |
| 30 | Supply & laying as in replacement 50mm bore steel water tubing medium grade fixed / erected as post for PTL fitting, fixed appropriately on ground with cement concrete or clamps, nuts, bolts as approved /directed by Engineer-in-Charge including preparing the galvanized exposed surfaces and applying two coats of Aluminium paint over a coat of red oxide / zinc chrome primer and two coats of black bituminous paint to planting depth complete all as specified and as directed with and including taking down old damaged steel pipe and removing from site of work complete all as directed. |
| 31 | Supply & laying as in replacement Multi stranded copper cable PVC insulated unearthed 1100Volts grade of size 2.50 Sqmm 3.00 Core for connection from junction box to light fitting and making connection and testing for functioning of light fitting complete all as specified and as directed with and including taking down old damaged cable and removing from site of work, complete all as of directed. |
| 32 | Supply and fix as in replacement RGB LED Flood Light luminaire of capacity 100 Watt lighting colour RGB lighting type with remote to change colours IP 65 protection, aluminium die cast housing, PF >0.95, LED driver, over voltage & under voltage protection, short circuit protection, with hanging & locking arrangement complete all as specified and as directed. |
| 33 | Supply and fix as in replacement RGB LED Flood Light luminaire of capacity 50 Watt lighting colour RGB lighting type with remote to change colours IP 65 protection, aluminium die cast housing, PF >0.95, LED driver, over voltage & under voltage protection, short circuit protection, with hanging & locking arrangement complete all as specified and as directed. Please Enable Macros to View BoQ information |