| 1 | Taking down cement plaster of any description on brick stone or concrete walls surfaces including raking out joints hacking for keys scrubing down with water etc complete all as specified and directed by Engineer-in-charge. |
| 2 | M&L for rendering 15mm thick in CM 1:4 on fair faces or other than fair faces of brick work or concrete surfaces firnished even and smooth without using extra cement up to hieght of four storey bldg ,including scaffolding up to 8 story building complete all as specified and directed by Engineer-in-charge.. |
| 3 | M&L for preparation of newly plastered surfaces of walls and providing and applying putty of 1.5 mm thickness over plastered surface to prepare the surface even and smooth and finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two ormore coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified as directed by Engr-in-charge.. Note spray painting(SMART PERIODICAL) |
| 4 | M&L for preparation of old decorated plastered surfaces of walls, complete removal of existing treatment by rubbing ,with mechanichal brooming down, washing with water etc and providing and applying exterior grade putty of 1.5 mm thickness over plastered surface to prepare the surface even and smooth and finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified as directed by Engr-in-charge. Note spray painting(SMART PERIODICAL) |
| 5 | M&L for preparation of old decorated surface (plastered or unplastered) of walls by complete removal of existing treatment by mechanical grinder and applying cement base wall care putty of 1 mm thickness over plastered surface to prepare the surface even and smooth to receive primer and applying one coat primer & two or more coats Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. |
| 6 | Demolition Bricks (laid flat or on edge) or brick tiles in floors, roof, channels, kerbs, aprons, etc. (each layer all as specified and directed. |
| 7 | Demolition Mud in roofs, any thickness, including plastering and lapping (whether full thickness removed or only a part thereof) all as specified and directed. |
| 8 | Removing soil excavated material exc. 1.5Km but n exc 5km and depositing where directed at above the starting point all as specified and directed. |
| 9 | M&L for cement concrete 1:2:4 type B1 (using 12.5mm graded stone aggregate) on roof padding surface finished even and smooth without using extra cement complete all as spd & directed. |
| 10 | M&L providing and applying the plaster with single component ready to use repair mortar (SMART CARE REPAIR MORTAR or equivalent) capable of applying 15mm average thickness in single layer and finishing with trowel with a bond coat: SBR polymer (@ 10% of cement weight) modified cementious bond coat @ 2.2 kg cement/Sqm of surface area mixed with specified portion of AP SMARTCARE or equivalent Repair Polymer including taking down existing roof treatment of any type including raking out joints, hacking for key, scrubbing down with water etc., to receive further treatment, complete all as specified land as directed.Note: The application shall be executed on any type of surface and on horizontal/Vertical areas. |
| 11 | M&L providing and applying Smartcare Dampproof, a fibre reinforced elastomeric liquid water proofing membrane formulated with reinforcing acrylic fibers having Sun Reflectivity Index (SRI) of 105 on horizontal/vertical surfaces of roof/wall/chajas in multiple coats @2.0 litre/sqm. Primary [coat is self-priming coat of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1, damp proof : water) and other coats to be applied undiluted. The coating needs to be reinforced with 40 GSM geotextile, to sandwiched between 2nd & 3rd coat of coating. The application shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes complete in all respect as per the direction of Engineer-in-Charge.Notes: for items ser No 10 & 11 (1) The work shall be executed through authorised applicator of manufacturer only.(2) Authrised Applicator shall be approved by GE before starting of work.(3) All materials shall be procured directly form manufacturer. The purchase voucher shall be produced to the Engineer-in-Charge for his verification of material.Engineer-in-Charge shall deface the original purchase vouchers.(4) Guarantee: The contractor shall furnish a written guarantee for the effectiveness of the water proofing treatment for a period of Ten (10) years in favour of the GE. A sum equivalent to 2.5% (Two point Five Percent) of the cost of water proofing treatment shall be retained by the Govt from the contractor's dues as security deposit. The contractor may, however, furnish a fixed deposit receipt in lieu from a Schedule bank pledged in favour of Garrison Engineer. |
| 12 | Taking up or down steel tubing 15 mm bore, and connections, including cleaning for re-fixing or removal to store in repairs complete all as specified. |
| 13 | S & F 15 mm bore, steel water tubing, medium grade, galvanized, with all fitting and fixed complete to walls and ceiling or laid into floor in repairs complete all as specified. |
| 14 | Taking up or down steel tubing 20 mm bore, and connections, including cleaning for re-fixing or removal to store in repairs complete all as specified. |
| 15 | S & F 20 mm bore, steel water tubing, medium grade, galvanized, with all fitting and fixed complete to walls and ceiling or laid into floor in repairs complete all as specified. |
| 16 | S&F in repair 110 mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid as rain water pipe dismantling old one complete all as specified. |
| 17 | Excavating in post holes each n exc 0.5 cum getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceedings 25cm watering and removing surplus soil to distance n exc 50 m and making good surfac in soft/loose soils |
| 18 | S&F Mild steel work as in compound girders and stanchions, latticegirders, aerial masts, post, struts, purlin rafter, staging for water tanks and like including caps bases, splices etc built up from two or more beam or channel sections or angles with plates or pipe section including all lattice bars, stiffeners, gusset plates etc..(Fe-410-W(Gde E-250)Quality-A) |
| 19 | S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 20 | M&L, two coats of synthetic enamel paint to untreated surfaces of steel any width or girth not otherwise described over a coat of red oxide primer after preparation |
| 21 | S & Fin repair 1000 ltr capacity three layer white colour rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including dismantling old water tank all as specified in SSR Part I(Make : Sintex/Rotex/Polywell) |
| 22 | S&F powder coated Anodiesed aluminium frame for partition, doors, windows, ventilators with one or more rebates incl. joining cleat for fixing etc. complete all as specified. |
| 23 | Taking down chowkhat or frame exceeding 1.5 Sqm each and not exceeding 4 Sqm each sqm each with shutter (without taking off shutter from the frame) |
| 24 | S&F powder coated Anodiesed aluminium door shutters, aluminium section weighing 0.55 Kg/m incl. necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each doors,Brass 2 lever mortice lock verticle type size 100mm, hinges, anodiesed aluminium snap beading screw with and opened or slider etc. |
| 25 | Supply and fixing PVC sheet consisting of 5mm thick light colour PVC sheet inclusive of fixing on PVC frame /Aluminium frame at site etc complete all as specified and as directed by Engineer-in- charge. |
| 26 | S&F door closer aluminium (extruded section) hydraulically regulated designation No. 03, universal type, suitable for door shutters of 851 to 1000mm in width and weight between 61 to 80 Kgs. |
| 27 | Supply and fixing Floor door stopper 140mm long of aluminium alloy and tongue, anodised with hard drawn steel spring fixed in floor etc complete all as specified & directed by Engineer-in-charge. |
| 28 | S&F 4.8 mm thick sheet glass, ordinary quality and glazing in Aluminium door with solar control files 50 micron in squares exc 0.5 Sqm each pane. |
| 29 | S&F Factory Made 18mm thick 100% Solid WPC,HDMR ( Wood polymer Composite ) Laminated Board of required size comprising of virgin PVC resin of K Value 57-60 ( Suspension Grade ), Calcium Carbonate and natural fibers ( Wood Powders/ rice husk/ wheat husk ) and Non toxic additives, made from Extrusion process WPC foam sheet Single Extruded ( Inner ) with having minimum density not less than 650 kg/cbm having good screw holding capacity ( Screw Withdrawal strength of 2000 N ( Face ) & 1100 N ( Edge ), Minimum Compissive of 50 N/mm2 , Modulus of elasticity 850N/mm2 and esistance of spread of flame of Class A category with Property of being Termite/ Borer Free.Water/ Moisture Proof and Fire Retardant. WPC to be Laminated with PVC foil of minimum 14 microns thick of approved design pasted on both faces of shutter and fixinng stainless Steel butt hinges or piano hinges and 75mm long extrruded fancy type SS handle for kitchen cupboard shutter fixed with nuts of required size with necessary full body threaded star headed counter sunk SS Screws. All as per direction of Engineer -In-Charge, Material test certificate and authentication should be compulsory provided by the manufacturing company : For WC/Bathroom/Toilet/Kitchen and Cabinets. |
| 30 | Demolition of concrete and pavings n.exc 15 cm thickness (below or above ground level) |
| 31 | M&L, PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in foundation, fitting and mass concrete |
| 32 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks,lawns, drive ways or light traffic parking etc.,of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; |
| 33 | M&L for providing cement concrete type C-1 1:3:6 (20mm graded aggregate) as in copings Complete all as specified and directed by Engineer-in-Charge. |
| 34 | M&L machine cut kota stone slab flooring 20-25mm thick over 15mm thick cement screed bed in cement mortar 1:6 laid and jointed with grey cement slurry mix with pigment to match the shade of slab complete all as specified |
| 35 | Roughning of surface of old cement concrete floor br packing sweeping clean and washing down with water to remove dust etc |
| 36 | M & L for 18-20 mm thick Black Granite stone work (table rubbed and polished) over and including15mm thick Screed bed or bedding layer in CM 1:4, as in steps, jambs, pillars, window cills, cooking platforms and like including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite,front and side of slab moulded and polished including dismantling the existing stone slab with screed/ backing and removal of debries out side the MOD Land complete all as specified and as directed by the Engineer-in-Charge.Note- The cost of making hole for Gas pipe in cooking plateform is included in unit cost of item and nothing extra shall be paid on this account. |
| 37 | M&L for sand filling under floor or in foundations including watering and consolidation Complete all as specified and directed by Engineer-in-Charge. |
| 38 | Supply and fix in repairs chromium plated brass angle valve suitable for 15mm bore pipe, complete all as specified. |
| 39 | S&F Mild steel rolled section Angle section or hollow pipes( square or round pipe) as in main and cross beam, hip and jack rafter, purlins, where connected to common rafter and running rails fixed with cleat or other connecting plates etc. complete all as specifed and directed |