| 1 | Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified . |
| 2 | M&L for 40 mm thick PCC type B-0,1:2:4 (using 12.50mm graded aggregate) as finished surface even and smooth without using extra cement complete all as specified |
| 3 | M&L for 75 mm thick PCC type C- 2,1:3:6 (using 40mm graded aggregate) in Path/ Hardstanding finished without using extra cement and making impressions of expanded metal whilst the concrete is green complete all as specified |
| 4 | M&L for Hardcore of Broken bricks gauge n exc. 63mm, deposited, spread & levelled in layers n exc. 15 cm thick, watered & rammed to a true surface complete all as specified |
| 5 | M&L for 38mm width and 1.50mm thick plastic dividing strips complete all as specified . |
| 6 | M&L for 75 mm thick PCC type C- 2,1:3:6 (using 40mm graded aggregate) as in subbase to receive the finishes complete all as specified |
| 7 | Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified . |
| 8 | M&L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floor and joints are filled with grey pigment cement and pigments laid over 15mm thik screed bed in CM 1:6 complete all as specified |
| 9 | M&L for Filleting in any position and to any shape in cement mortar 1:4 including all mitres, stops, etc.of Cross section exc 25 Sqcm and n exc 50 Sqcm complete all as specified . |
| 10 | M&L Machine pressed precast concrete interlocking paver block any colour,shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade laid over 50mm thick sand cushion layer and pointed in white or .coloured cement with pigment to match complete all as specified and as directed |
| 11 | M& L Providing cement concrete in Type B0 1:2:4 (12.5 mm graded stone aggregate) as in copings, water throughs and the like including weathering, slightly rounded or chamfered angles andf throating complete all as spcifiecd |
| 12 | Demolition of brick work built in cement mortar complete all as specified . |
| 13 | M&L for Brick work with sub-class `B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified . |
| 14 | M&L for 2 coats of synthetic enamelled paint over coat of red oxide zinc chrome on steel surfaces over 10cm width or girth including preparation of new surfaces complete all as specified and as directed. |
| 15 | Demolition of precast reinforcement cement concrete in ground floor and paving n.exc 15 cm thickness (below or above ground level). |
| 16 | M&L for Providing Precast cement concrete in cover slab for drain and similar articles with plain faces in set with CM (1:4) of concrete 1:1.5:3 type B1 using 20mm graded aggregate complete as specified. |
| 17 | M&L for TMT bars 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality confroming to Fe500 |
| 18 | S& F in repair 110mm bore , for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid complete all as specified .in trenches or in floors complete all as specified and as directed |
| 19 | M&L 10 mm thick rendering in CM (1:6) on fair faces of brick work or concrete surfaces without using extra cement complete all as specified . |
| 20 | M & L for preparation of new plastered surfaces and applying two coats of cement base paint over a coat of primer complete all as specified and as directed |
| 21 | S&F Stainless steel pipes and chain of grade 304, polished for in parapet railing alongwith SS balls and all accessories complete all as specified and as directed. |
| 22 | NOTES :-1. The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum.2. Unless otherwise specified the rates for PCC shall deemed to include the cost of formwork shuttering etc, required for complete and proper execution of the work. Refer Schedule 'A' notes for details. Please Enable Macros to View BoQ information |