| 1 | S&F in repair galvanised 2 strand, steel barbed wire 2.24 mm dia, barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails, straining bolts including securing or tying at crossing with provision of galvanised mild steel wire, staples or steel pin etc. as directed complete all as specified and directed (each line to be measured). |
| 2 | Dismantling fencing wire mesh any type and any size complete all as specified and directed |
| 3 | Supply only MS galvanisedChainlink fencing any type and any size complete all as specified and directed |
| 4 | Fixing only chain link fencing including link wire, any mesh, size and type to any type of standarts , rails, straining, bolts, etc including provision of binding of wire complete all as specified and directed |
| 5 | Demolition of cement concrete (un reinforced) in ground floors and paving n exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 6 | M&L for PCC (1:2:4) type B1 type (using 20 mm graded crushed stone aggregate) as in path hardstanding etc complete all as specified and directed |
| 7 | M & L for PCC (1:2:4) type B1 type (using 20 mm graded crushed stone aggregate) as in coping incl all necessary form work as required, complete all as specified and directed. |
| 8 | M&L for cement concrete type D-2 (1:4:8) using (40mm graded aggregate) in foundation filling and mass concrete all as specified and as directed by Engr-in-Charge |
| 9 | M&L for 25mm thick cement concrete type B-0, (1:2:4) using 12.5mm graded aggregate complete all as specified and directed |
| 10 | M & L for Cement concrete in drains Type B1 1:2:4 (20 mm graded aggregate) slope maintained as per site requirement complete in all respect complete all as specified and directed |
| 11 | M&L for 75mm thick PCC (1:3:6), type C2, using 40mm graded stone aggregate as in plinth protection / paving, surfae finished even & smooth with using extra cement as complete as specified and directed. |
| 12 | Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed. |
| 13 | M&L for brick work with sub class 'B' bricks straight or curved in plan exc 6 mtr mean radius built in CM (1:6) using old size bricks complete all as specified and as directed. |
| 14 | M&L for brick work with sub class 'B' bricks straight or curved on plan to any radius in half brick thick wall built in CM (1:4) complete all as specified and directed. |
| 15 | Taking down cement plaster of any description on brick or stone walls or from concrete surface incl raking out joints, hacking for key, scrubbing down with water etc all as specified,and removing unserviceable material outside cantt area complete all as specified and directed |
| 16 | M&L for rendering 15 mm thick in CM (1:6) on brick/concrete wall surfaces of any description, and finishing the surfaces even and smooth without using extra cement complete all as specified and directed . |
| 17 | M&L for rendering 15mm thick on brick work or concrete surfaces of wall in CM (1:4) and finishing the surfaces even and smooth without using extra cement complete all as directed. |
| 18 | Demolition of RCC work of any description and in any position not otherwise specifically provided for complete all as specified and directed (reinforcement cut as required to facilitate demolition). |
| 19 | M&L for pre-cast reinforced cement concrete (1:2:4) type B1(using 20 mm graded crushed stone aggregate) as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces etc set in CM (1:6) including necessary forms, moulds etc complete all as specified and directed |
| 20 | M&L providing pre-cast cement concrete 1:2:4 Type B0 (using 12.5 mm graded crushed stone aggregate) louvers and jallies, 55 mm thick (measured solid), including all moulding but excluding frame and set in cement mortar 1:4 complete all as specified & directed. |
| 21 | Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and directed |
| 22 | M&L for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified as directed. |
| 23 | S&F steel work in tubular including special shaped wahser etc complte using ERW or induction butt welded tybes conforming to IS 1161-1979St grade St-240 complete all as specified and directed |
| 24 | M&L for MS TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia as reinforcement complete all as specified and directed |
| 25 | Dismantling old/rusted plain or corrugated steel sheeting any gauge thickness as in roof covering with ridges etc complete as specified and directed. |
| 26 | S&F 0.50 mm thick pre- painted galvalume aluminium zinc coating GI based corrugeted steel sheet of any colour as approved of 550 Mpa tensile strength as in roof covering / cladding to wall fixed with self tapping screws complete all as specified and directed |
| 27 | M&L for Pre-painted galvalume aluminium zinc coating GI based plain sheet 0.50 mm thick any colour having tensile strength of 550 Mpa as in ridges, hips valley gutter etc fixed with self tapping screws complete all as specified and directed |
| 28 | M&L for 2 mm thick fibre glass reinforced translucent corrugated sheeting with two corrugation side lap fixed with coach screw and washer in roof walls etc. complete all as specified and directed. |
| 29 | Material & Labour for applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed |
| 30 | Material & Labour for applying one coat of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed |
| 31 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 32 | M&L for screed bed or bedding layer 15 mm thick in cement mortar (1:6) on floors for laying floor finish complete all as specified and as directed. |
| 33 | M&L for 10 mm thick plastering in cement mortar (1:4)brick or on concrete surfaces of wall as in backing coat of wall tiles etc complete all as specified and directed |
| 34 | M&L for dark shade vitrified ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick 1:6 cement mortar screed bed over 25 mm thick cement concrete (1:2:4) type B1 as in floor complete all as specified and directed compete all as specified and directed. |
| 35 | M&L non skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match compete all as specified and directed. |
| 36 | M&L Granite (of any type) tiles, 20 mm thick machine cut laid over cement screed as in floor and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of the granite stone including cutting and polishing complete all as specified and directed (Note :- Screed bed shall be measured and paid separately under respective item) |
| 37 | M&L for coloured Glazed ceramic tiles in vertical surface 300 x 200x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and directed. (Note : Screed bed or bedding layer shall be measured and paid separately under respective items in this schedule). |
| 38 | M&L for chequered cement concrete tiles 30 cm x 30 cm x 25 mm thick, set jointed and pointed in neat cement slurry with grey cement and pigments as in floor complete all as specified and directed. (Note : Screed bed or bedding layer shall be measured and paid separately under respective items in this schedule). |
| 39 | M&L for Extra for forming fair finished drain or channel 55 cm inner girth in cement concrete using extra cement including forms, moulds mitred/stopped ends etc complete all as specified and directed |
| 40 | Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement including taking down old one complete all as specified and as directed. |
| 41 | M & L for preparation of old wood or wood based surface and applying one coat of synthetic enamel paint ,complete all as specified and directed |
| 42 | M & L for preparation of old wood or wood based surface and applying two coats of synthetic enamel paint , complete all as specified and directed |
| 43 | M&L for preparation of old steel surfaces exc 10cm width or girth and applying one coat of synthetic enamel paints complete all as specified and directed |
| 44 | M&L preparation of old steel surfaces exc 10cm width or girth and applying two coats of synthetic enamel paints complete all as specified and directed |
| 45 | M&L for preparation of new steel surfaces exc 10cm width or girth and applying two coats of synthetic enamel paints over one coat of red oxid zinc crome primer complete all as specified and directed |
| 46 | S&F in repairs for powder coated aluminium sections for side hung/sliding window/doors and partitions etc. with suitable sections for frame and shutter fixed with dash through holder fastener with length not less than 75mm to walls/floors including locking arrangement and rubber gusket necessary channel, neoprene beading, clips, fixing screws, nuts etc. complete all as complete all as specified and directed |
| 47 | S&F anodised aluminium grill, 10mm thick, diamond shape with apareture 75mm fixed to windows including u type frame and nutcomplete all as specified and as directed. |
| 48 | S&F 12 mm thick prelaminated particle board interior grade laminated on both sides complete all as specified and directed |
| 49 | Hacking out old broken glass (any thickness size, quality or description) from wooden frames or stone, concrete or brick surrounds glazed with putty or fixed with beads all as directed. |
| 50 | M&L for 5.5 mm thk froested Sheet glass, ordinary quality and glazing with brass screws in square exc 0.5 sq. m in each pane complete all as specified as directed |
| 51 | S&F sheet glass 4.0 mm thick ordinary quality and glazing with oil putty suare, rectangle n.exc 0.5 Sqm in each pan all as specified and as directed. |
| 52 | S & F Aluminium alloy wire cloth 0.45 mm nominal dia of wire and avg width of appreature 1.40 mm and fixed with aluminium wire staples complete all as specified and as directed. |
| 53 | M & L for preparation newly plastered surfaces of wall and applying two coats of cement base paint over a coat of alkali resistant priming paint on plastered surfaces complete all as directed. |
| 54 | M & L for preparation old plastered surfaces of wall and applying two coats of cement base paint over a coat of alkali resistant priming paint on plastered surfaces complete all as directed. |
| 55 | M & L for preparation newly plastered surfaces of wall and applying three coats of white wash over a coat of chalk whiting priming paint on plastered surfaces complete all as directed. |
| 56 | M & L for preparation old plastered surfaces of wall and applying two coats of white wash over a coat of chalk whiting priming paint on plastered surfaces complete all as directed. |
| 57 | Dismantling of 100 mm dia cast iron drain pipes/PVC pipe jointed in cement mortar and taking out old pipe complete all as specified and directed. |
| 58 | S&F 110 mm dia PVC (SWR) pipes single, socketed, in any length with rubber ring joints fixed to wall complete all as specified and directed. |
| 59 | S&F PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floors bore of pipe 75 mm complete all as specified and directed |
| 60 | S&F PVC (SWR) bends any radius of 110 mm dia with access door complete all as specified and directed. |
| 61 | S&F PVC (SWR) bends any radius of 75 mm dia with access door complete all as specified and directed. |
| 62 | S&F 110 mm dia PVC (SWR) Cowls all as specified and directed including taking down old one.. |
| 63 | Taking out accumulated garbage and other deposits such as broken bricks, silt etc from manholes / gully trap of depth n.exc 1.5 mtr, cleaning as directed and removing the same to a distance n.exc 50 mtr and buried below ground level including necessary excavation of pits and returning, filling in, sprinkling of bleaching powder and dressing of soil around to slope, if any and all as directed, stacking serviceable brick bats for reuse complete all as specified & directed. |
| 64 | M&L for sand cushioning under interlocking paver block complete all as specified and directed |
| 65 | S&F 450 mm bore Reinforced concrete pipe class NP 3 with one collar per length of pipe complete all as specified and directed |
| 66 | M&L for 60 mm thick machine pressed precast interlocking paver block of M-35 Grade any shape and size with grey cement and pigment confirming to IS 15658-2006 complete all as Specified and as directed |
| 67 | S&F 10 -12 mm thick multicell polycarbonate sheet fixed with roof, partition etc complete all as specified and as directed |
| 68 | M&L for Thermoplastic road mark painting lines, dashes, arrows, letters etc on roads, pavements and the like exc 10 cm wide with road marking paint, white or golden yellow, complete all as specified. |
| 69 | M&L 300x300x 10 mm thick heavy duty parking tile , set jointed and pointed in neat cement slurry with grey cement and pigments as in floor complete all as specified and directed. (Note : Screed bed or bedding layer shall be measured and paid separately under respective items in this schedule). Please Enable Macros to View BoQ information |