| 1 | Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for all as specified and directed |
| 2 | Demolition of precast cement concrete block walling built in CM or cement lime Mortar complete all as specified and as directed |
| 3 | M&L precast cement concrete block masonry exc 10 cm width with solid block PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) and setting in cement mortar 1:4 all as specified |
| 4 | Excavation in trenches n. exc 1.5m wide and n. exc 1.5m in depth in hard/dense soil for foundation, etc or for shafts, wells, cesspits, manholes, pierholes, etc n. exc 10 Sqm on plan and getting out complete all as specified and directed |
| 5 | Returning filling in hard/dense soil including spreading levelling watering and well ramming in layers n. exc 25cm thick complete all as specified and directed |
| 6 | Removing excavated material (any type of soil) to a distance n. exc 50m and depositing where directed at a level n. exc 1.5m above the starting point complete all as specified and directed |
| 7 | M&L Cement concrete 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundations or mass concrete complete all as specified and as directed |
| 8 | M & L for Cement concrete Type C2 1:3:6 (40 mm graded aggregate) in surface channels and drains complete all as specified and as directed |
| 9 | Extra for forming fair finished drain or channel 45 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. |
| 10 | Taking down cement plaster on concrete or brick masonry surface including raking out joints, hacking for keys scrubbing down with water etc to receive plaster all as specified. |
| 11 | M&L for 15mm thick plaster in CM 1:4 on fair face of brick walls or concrete surface including mixing of liquid water proofing compound @ 200ml per 50 Kg cement bag, finished the surface even and smooth without using extra cement complete all as specified. (Note: Water proofing compound shall be measured and paid separately) |
| 12 | Supply only liquid water proofing compound.[Make : FOSROC/ Dr FIXIT / IMERMO / PIDILITE INDUSTRIES LTD] |
| 13 | M&L for preparing newly plastered wall surface and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali and fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces complete all as specified and directed |
| 14 | M&L for complete removal of old decorated surfaces of walls and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.cornices and applying two coat of antifungal exterior emulsion paint including one coat of primer complete all as specified and as directed. |
| 15 | M&L for framed work such as grills, gratings, etc,. With ends of bars shouldered and/ or riveted, or forged into spikes; framed guard bars, barred iron doors ladders including portions framed and hung as gates, including pintle hinges, stops, hand made sliding bolts for ornamental and intricate design as specified and directed |
| 16 | M&L for applying two coat of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surfaces of any description over 10cm width or girth not otherwise described complete all as specified and directed |
| 17 | M&L for RCC Nominal mix B1 1:1:2 (using 20mm graded crushed stone aggregate) in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc, basement slabs, under-reamed piles and mass concrete complete all as specified and directed |
| 18 | M&L for RCC Nominal mix B1 1:1:2 (using 20mm graded crushed stone aggregate) in columns, pillars, piers, posts and struts complete all as specified and directed |
| 19 | M&L for RCC Nominal mix B1 1:1:2 (using 20mm graded crushed stone aggregate) in beams, cantilevers, bressummers, lintels over 1.5m span all as specified and directed |
| 20 | M&L formwork for rough finished flat surface to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter complete all as specified and directed |
| 21 | M&L formwork for rough finished surface of square, rectangular or triangular surface to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed |
| 22 | M&L formwork for rough finished flat surface to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup-ports, overhangs, etc also splays between floors and beams, etc complete all as specified and directed |
| 23 | M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed |
| 24 | M&L for mild steel TMT bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed |
| 25 | Demolition of cement concrete (unreinforced) in ground floor and pavings n exc 15 cm thickness all as specified and directed. |
| 26 | Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed |
| 27 | M&L for Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. complete all as specified and as directed by Engr-in-Charge |
| 28 | M&L formwork rough finished surface of concrete to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n. exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work n. exc 10 cm wide complete all as specified and directed |
| 29 | Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out in hard dense soil complete all as specified and directed |
| 30 | M & L for hardcore of gauge n exc 63 mm deposited spread and levelled in layers n exc 15 cm thick watered and rammed to a true surface of broken stone or boulders complete all as specified and directed |
| 31 | M & L for providing 100 mm thick, PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in sub base of floors complete all as specified and directed |
| 32 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified |
| 33 | M&L for chequered cement concrete tiles of size 30cm X 30cm X 25mm thick with grey cement and pigments set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile as in floor over and including 20mm thick screed bed in CM 1:4 complete all as specified and directed |
| 34 | Dismantling of chain link fencing of any gauge and size not exceeding 4 Kg/ Sqm complete all as directed by Engr- in - Charge |
| 35 | Supply and fix mild steel galvanised PVC coated chain link fencing 3.15mm nominal dia of GI wire, 1.4mm thick PVC coating and average area of aperture 25 sqcm with weight of chain link not less than 2.50 Kg/Sqm complete all as specified and directed |
| 36 | Dismantling structural steel work of any description and in any position etc complete all as specified. |
| 37 | Demolition of stone slabs and tiles of any description laid bedded and pointed in mortar all as specified and directed.. |
| 38 | M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified |
| 39 | Mild steel screw bolts diameter of neck 16 to 20mm (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm but n exc 10cm long complete all as specified and directed |
| 40 | M & L for roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe-410-W(Gde-E-250) quality-A complete all as specified. |
| 41 | S & F Rolled sections as in main and cross beams, hip and jack rafters; purlins, pole where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates using structural steel of Fe-410W (Gde E-250 quality A) complete all as specified and directed |
| 42 | S & F Mild Steel work in tubular trusses and tubular posts/ purlins including special shaped washers etc., complete using ERW or induction butt welded tubes conforming to IS :1161-1979 grade st-240 including notching, drilling, fitting, riveting and/or welding or connecting with bed plate, bolt and nuts complete all as specified and as directed by Engineer -in-Charge |
| 43 | S&F mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed |
| 44 | M&L for PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate as in filling, foundation and mass concrete complete all as specified and as directed. |
| 45 | M&L for mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed |
| 46 | Dismantling plain or corrugated steel sheeting, any gauge, thickness including nainital or similar pattern in roof coverings complete all as specified and directed |
| 47 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specifiedMAKE : TATA BLUE SCOPE/ JSW / METCO ROOF |
| 48 | M & L aluminium wind tie of any size fixed with self tapping screws of size 50/75mm with integral EPDM washer in roof covering complete all as specified and directed |
| 49 | Excavation in trenches not exc 1.5 M deep and 1.5 M width and getting out in soft or loose soil for foundation of poles (or) cable laying complete all as specified and directed |
| 50 | M&L for Precast cement concrete (PCC) type B1 1:2:4 using 20mm graded aggregate stone for making copings including use and waste of form work complete etc complete all as specified and directed |
| 51 | Supply, laying, testing and commissioning of underground LT XLPE insulated, armoured heavy duty electric aluminium conductor cable 1100 Volts grade of cross section 2 x 10 sqmm (laid in terenches, ducts, pole, wall etc.) incl taking down old unsv cable all as specified and directed. |
| 52 | M & L for cutting the road/ footpath/ hard standing etc for laying of pipe all as directed by Engr In Charge. |
| 53 | Supply and laying in trenches or in cable ducts or clamping on wall DWC HDPE pipe of size 40 mm (OD) x 32 mm (ID) along with connected accessories like couplers.bends,end caps etc. for LT cable protection all as specified and directed. |
| 54 | Supply & fix Cable Junction Box of size 130 x 130 x 77, IP 66 (Grey) with integrated membranes / metric knockouts for cable entry of size 2.5 sqmm to 6 sqmm twin core with earth, Lighting Outgoing cable: 3C x 1.5/ 2.5 Sq.mm cable, Degree of protection: IP66, Material: PC-GFS (polycarbonate) , Weatherproof, resistant to weather influences including taking down the old/unserviceable junction boxes all as specified and directed. Make : Hensel model No DK 0606 G or equivalent in Sintex |
| 55 | S & F Sub main wiring with PVC insulated cable 2 single core 1.5 sq mm 1100 V grade with stranded copper conductor cable using proper colour coding Phase Red/Yellow/Blue, Neutral- black and earth- green in and incl rigid PVC conduit concealed /surface in wall/ on surface (ISI marked) incl all specials like joint elbow, Tee ,junction , bend etc and provision of PVC insulated copper conductor single core 1.5 sq mm for earth continuity all as directed. Note : Two runs (2P+1N) of copper conductor, One run of copper conductor as earth wire and one run of PVC casing and capping / PVC conduit shall be measured as one unit length. |
| 56 | Supply and fixing of outdoor type Decorative Post top for 360° indirect light with IP 65 protection, resistant to impact and corrosion of 240 v,50hz of capacity 40 watt LED suitable for mounting on 60 mm OD pipe on necessasry PCC works complete all as specified and directed. Make : CG Model No LPTO-40-CDL-M or equivalent to Havells/Philips |
| 57 | Taking down of old rusted / damaged pipe line and Supply and fixing pipe galvanized, “Medium class”, including fittings 40 mm dia all as specified and directed. Please Enable Macros to View BoQ information |