| 1 | Dismantling and taking out the existing old unserviceable compressor hermetically sealed unit of Inverter/Non Inverter type window type AC and S&F in replacement of New compressor suitable for window AC of capacity 1.5 Ton complete all as specified and directed. |
| 2 | All as srl item No 1.00 above but compressor suitable for Inverter/Non Inverter type window AC of capacity 2.0 Ton. complete all as specified and directed. |
| 3 | All as srl item No 1.00 above but compressor suitable for Inverter/Non Inverter type Split AC of capacity 1.5 Ton. complete all as specified and directed. |
| 4 | All as srl item No 1.00 above but compressor suitable for Inverter/Non Inverter type Split AC of capacity 2 Ton. complete all as specified and directed. |
| 5 | M&L for testing leakage in system of Inverter/ Non Inverter type Window /Split type Air conditioner of 1.5/2.0 ton capacity by injecting nitrogen gas upto 300 PSi, repairing leaking spots/joints with gas welding including supply & fixing of filter pencil type copper (in replacement), cleaning & flushing out complete system with gas, making the system leak proof, vaccumising the system complete all as specified and directed. |
| 6 | M&L for servicing of Air conditioning of Inverter/ Non Inverter type Window/Split of any capacity including air Filter Cleaning, Condenser and Evaporator coil Cleaning, insulation of tubing with expanded polythene foam insulation tubing and making necessary connection including M&L for unplastiised PVC pipe medium duly 20 mm dia for draining out condensed water complete all as specified and directed.Note : Petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department. |
| 7 | The following items Supply & Fixing only in replacement for Inverter/ Non Inverter type window AC/Split AC any Make any Capacity complete all as specified and directed :- |
| 8 | Starting capacitor. |
| 9 | Running Condenser. |
| 10 | Cooling Coil /condensor coil. |
| 11 | Swing motor suitable. |
| 12 | Over load relay. |
| 13 | PVC Front gril. |
| 14 | Electric blower motor double shaft. |
| 15 | Blower motor fan blade. |
| 16 | Condenser motor with fan blade. |
| 17 | Thermostat switch with knob suitable. |
| 18 | Air Filter. |
| 19 | Capillary tube length. |
| 20 | PCB Circuit with remote control. |
| 21 | PVC flexible waste condensing. |
| 22 | Suction pipe. |
| 23 | M&L for replacement of damaged Insulation of any size. |
| 24 | M&L for replacement of Copper Tube of size. |
| 25 | Taking out and shifting new location and refixing both indoor and outdoor unit of Inverter/ Non Inverter split type Air/ window AC electrically driven 230V/250V ,AC 50 Hz capacity 1.5/2.0 Ton in wall with rowl plugs including making holes for inlet /outlet in any type and any thickness of wall with manually or any equipment and 50mmX50mmX6mm size of agle iron for foundation of condensing unit as per suitable size and making good existing surface including insulation of tubing with expanded polythene foam insulation tubing and making necessary connection including M&L for unplastiised PVC pipe medium duly 20 mm dia for draining out condensed water all as required and directed including necessary connection through voltage stabilizer complete all as specified and directed. |
| 26 | Disconnecting of old indoor unit of 1.5/02.00 ton capacity S&F in replacement of new indoor with 1.5/2.0 ton inverter/ Non Inverter as per site requirement with Fixing arragement complete all as specified and directed. |
| 27 | Disconnecting of old outdoor unit of 1.5/02.00 ton capacity S&F in replacement of new outdoor with 1.5/2.0 ton inverter/ Non Inverter as per site requirement with Fixing arragement complete all as specified and directed. |
| 28 | Disconnecting of unserviceable sub main wiring of 4 Sqmm size including conduit of any type and accessories & removing from site and making good the disturbed surfaces, complete all as specified and directed. |
| 29 | T&D and S&F in replacement MCB distribution board single pole & neutral with 200 Amps rated bus bar, double door, IP-43, DB's made out of CRCA sheet steel enclosure, recessed type, factory made powder coated, 4 way, 240 volts suitable for housing MCB's and isolator's complete in all fixing material/accessories etc complete all as specified and directed. Note : MCB DB and MCB will be the same make. |
| 30 | M & L for Submain wiring with two single core PVC insualated, unseathed, FRLS, 1100 volts grade 4 Sqmm multi stranded copper conductor cable drawn through and including 25 mm dia PVC non metallic rigid conduits and the conduits accessories incl one run of green colour earth continuity conductor with 4 Sqmm multi stranded copper conductor cable, in concealed conduit in wall/ roof/ ceiling, complete all as specified and directed. Note : - Two run of single core cable, one run of earth continuity conductor shall be measured as one unit length. |
| 31 | M & L for Submain wiring with two single core PVC insualated, unseathed, FRLS, 1100 volts grade 4 Sqmm multi stranded copper conductor cable drawn through existing concealed conduit incl one run of green colour earth continuity conductor with 4 Sqmm multi stranded copper conductor cable complete all as specified and directed. Note : - Two run of single core cable, one run of earth continuity conductor shall be measured as one unit length. |
| 32 | S & F of MCB SP, 240 volt, 6 Amp to 32 Amp capacity, 10 KA, 'C' Type instantaneous tripping complete all as specified and directed. |
| 33 | Supply and fixing of MCB SPN 10 to 40 Amp capacity, 10KA , 'C' Type instantaneous tripping complete all as specified and directed. |
| 34 | S & F in repair single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 20 Amp MCB SP `C' type instantaneous for geyser & AC complete all as specified and directed. |
| 35 | Dismantling and taking out the existing old unsv compressor sealed unit from Water cooler and S&F in replacement new compressor copper wound unit for operation on single phase, 230 V, 50 Hz, AC supply & confirm to IS-1067 Part-I, suitable for Water cooler of cooling capacity 40/80 ltrs/hrs complete all as specified and directed.Note 1. All Engineering works shall be carried out at site/E/M store yard only in presence of JE/Engr- in- Charge. 2. No equipment shall be transport/carry out to local market for repairs.Make : As per existing sample |
| 36 | All as srl item No 18.00 but compressor suitable for Water Cooler of cooling capacity 60/120 ltrs/hrs complete all as specified and directed. |
| 37 | All as srl item No 18.00 but compressor suitable for Water Cooler of cooling capacity 150/150 ltrs/hrs complete all as specified and directed. |
| 38 | M&L Checking the unserviceable water cooler of any make, size and capacity, making it serviceable by tightening the connection, checking power point and making it functional, replacement of screws, small pieces of wire, etc complete all as specified and directed. |
| 39 | The following items Supply & Fixing only in replacement for water Cooler of any make and any Capacity as per existing sample complete all as specified and directed :- |
| 40 | Condensor motor. |
| 41 | Condenser Blower fan blade. |
| 42 | Capacitor. |
| 43 | Starting relay current type. |
| 44 | Over load Protector with relay box type. |
| 45 | Thermostat switch with knob. |
| 46 | PVC float valve of size 15 mm assy alongwith ball with complete accessories. |
| 47 | Self closing water tap 15 mm dia chromium plated inner/outer thread. |
| 48 | Capillary tube of suitable length. |
| 49 | Taking out old u/s copper conductor cable lead from water cooler any capacity and supply and fixing new copper conductor cable for water cooler lead size 2.5 sqmm 3 core AC, 50 Hz, PVC sheathedand overall PVC insulated complete all as specified and directed.Make : Havells/Polycab |
| 50 | Taking out old US plug top and S & F of new plugtop of 15 Amp complete all as specified and directed.Make: Anchor/Cona. |
| 51 | Taking out old US PVC drain pipe from water cooler any capacity and S & F new PVC drain pipe with clamp of size 40 mm dia for water cooler complete all as specified and directed. |
| 52 | M&L for testing the leakage in system by charging of Nitrogen Gas up to 300 PSI. Repairing of leakage spots/Joints with gas welding work, cleaning and flushing the complete water cooler with gas, making the system leak proof, vacuuming the complete system complete all as specified and directed. |
| 53 | Supply and replacement of condensing coil suitable for Water Cooler of capacity 40/80,60/120,150/150 Ltrs including welding/soldering, at site complete all as specified and directed. |
| 54 | M&L for removing burnt/defective sealed compressor in replacement of new compressor any make and Capacity of refrigerator inverter/ Non inverter type, Single/Double Door by cutting of suction and discharge lines and un-screwing of foundation nuts and supply & fixing compressor sealed unit including necessary brazing work as required.new sealed compressor unit complete all as specified and directed. |
| 55 | M&L Checking the unserviceable Refrigerator of any make, size and capacity, making it serviceable by tightening the connection, checking power point and making it functional, replacement of screws, small pieces of wire, etc complete all as specified and directed. |
| 56 | The following items supply and fixing in replacement of any make /capacity/type as per existing sample complete all as specified and directed.:- |
| 57 | Front grill suitable. |
| 58 | Freezer. |
| 59 | Relay current type and thermal over load protector. |
| 60 | Thermostat auto defrost type. |
| 61 | Air Filter suitable for any make and any capacity Refrigerator. |
| 62 | Capillary tube including brazing work of suitable length. |
| 63 | Heater Coil. |
| 64 | PCB for invertor/Non inverter any type of refrigerator. |
| 65 | M&L for removing burnt/defective sealed compressor unit including brazing work of 320 Ltr of Deep freezer by cutting of suction and discharge lines and un-screwing of foundation nuts and supply & fixing new sealed compressor unit complete all as specified and directed. Make : as per existing sample. |
| 66 | M&L for testing the leakage in Deep Freeze system by charging Nitrogen Gas up to 300 PSI. Repairing the leakage spots/Joints with welding work including supply and replacement of filter pencil type copper and capillary tube of existing dia & length. Making the system leakproof vacuuming the system complete all as specified and directed. |
| 67 | M&L Checking the unserviceable Deep Freezer of any make, size and capacity, making it serviceable by tightening the connection, checking power point and making it functional, replacement of screws, small pieces of wire, etc complete Note:- petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department.complete all as specified and directed. |
| 68 | The following items supply & Fixing in replacement for Deep Freezer of any make / Capacity as per existing sample complete all as specified and directed :- |
| 69 | Relay current type and over load protector. |
| 70 | Thermostat auto defrost type. |
| 71 | Drier filter complete set. |
| 72 | Blower motor |
| 73 | Capillary tube of suitable length |
| 74 | Starting relay. |
| 75 | Starting capacitor. |
| 76 | Axial fan motor with Condenser motor (Rotary/Axial fan). |
| 77 | M&L for Repairing welding rejointing the body leakage any type and any where including replacement the existing copper pipe or condenser and capillary tube of deep Freezer existing dia & length. Making the system leakproof complete all as specified and directed. |
| 78 | Supply and replacement of old unsv copper bound Fan motor with frame legs and nut, bolts including iron blade for desert cooler 1350RPM or 1/7HP single phase 220 volt 50C/S, 375-450mm including fixing nut bolts of desert cooler and making necessary electrical connection and testing complete all as specified and directed. |
| 79 | M&L for rewinding of desert cooler fan motor of 1/7HP /1/8 HP single phase 3 speed with super ennamelled copper wire of appropriate gauge with insulating material complete after removing old burnt wire including servicing change the unserviceable bush, shaft and testing after completion , complete all as specified and directed. |
| 80 | S&F in replacement of Water circulating submersible pump, 1300 RPM, SP, 230V, 50Hz 1.5M head , discharge 7.0 Ltrs/hr complete all as specified and directed. |
| 81 | Supply and Fixing in replacement of Capacitor of desert cooler as per existing size. complete all as specified and directed. |
| 82 | Supply and Fixing of Filter pad made out of wooden wool suitable for Air grills of desert cooler as per existing size. complete all as specified and directed. |
| 83 | M&L of Painting the external portion of desert cooler with 2 coat of synthetic enamel paint of Ist grade over a coat of zinc chrome primer after scarping existing painted surface and painting the interior portion of the cooler with 1 coats of anti corrosive paint and refixing all components and testing complete all as specified and directed. Make : Asian/Berger. |
| 84 | Supply and fix in replacement of complete Desert Cooler with 1350RPM or 1/7HP single phase 220 volt 50C/S, body made out 22 gauge GI sheet of desert cooler, Water circulating submersible pump, 1300 RPM, SP, 230V, 50Hz 1.5M head , discharge 7.0 Ltrs/hr complete all as specified and directed. |
| 85 | S&F PVC Flexible hose suitable for desert cooler cooling system as per existing sample requirement complete all as specified and directed. |
| 86 | Supply and fix in replacement of Fan Blade made of aluminium suitable for 3000/4000/5000/6000 as per sample requirement complete all as specified and directed. |
| 87 | S&F in replacement Selector switch three way speed control switch including 5Amp switch rotary type for desert cooler as per existing model and size make as per existing sample complete all as specified and directed. |
| 88 | S&F PVC Connector i.e (Elbow, Tee,3 way etc) complete all as specified and directed. |
| 89 | S&F in replacement of U/S Voltage stabilizer 2 KVA to 3 KVA, with digital display input voltage range 90 volt to 220volt and output voltage 220 volt to 230 Volt AC + 2% variation of voltage complete with accessories etc. complete all as specified and directed.Make:V-guard/Microtek. |
| 90 | S&F in replacement of U/S Voltage stabilizer 04 KVA to 5KVA , with digital display input voltage range 90 volt to 220volt and output voltage 220 volt to 230 Volt AC + 2% variation of voltage complete with accessories etc As per existing sample requirement complete all as specified and directed.Make: V-guard/Microtek. |
| 91 | M&L for charging of Refrigerant R-22/F-22/R-410A/R-134(a)/R-32 or any as per site requirement in Split/Window AC, water cooler, deep freezer, Walk in Cooler of any capacity complete all as specified and directed. Please Enable Macros to View BoQ information |
| 92 | M&L for charging of Refrigerant R-22/F-22/R-410A/R-134(a)/R-32 or any as per site requirement in Split/Window AC, water cooler, deep freezer, Walk in Cooler of any capacity complete all as specified and directed. Please Enable Macros to View BoQ information |