| 1 | Dismentaling &Taking down unserviceable street light fittings LED Fittings/ CFL Fittings,post top lantern,garden light, Pin /Holder type from pole or from Bldgs for repairs including replacement of unserviceable Lamp, holder, internal wiring with appropriate gauge copper conductor and refixing the same after repairs in original position properly using PVC insulation tape or where directed complete including replacement of any spares,cable connections from OH conductors,or from junction boxes to light fitting complete all as specified and as directed.Note : Spares items such as LED driver and cable etc, will be measured and paid separately under respective items. |
| 2 | Taking down and dismantling old/rusted/broken steel poles/struts,removing from site and making good disturbed surface complete all as specified and directed. |
| 3 | Dismantling and taking down unserviceable UG cable of any size all as specified and directed.. |
| 4 | Supply & Fixing in replacement PVC insulated weather proof sheated alluminium cable 2.5 sq mm 2 core complete all as specified and as directed. |
| 5 | Supply & Fixing in replacement LED Driver 60 Watt complete all as specified and as directed. |
| 6 | Supply & Fixing in replacement LED Driver 90 complete all as specified and as directed. |
| 7 | Supply & Fixing in replacement LED Driver 100 complete all as specified and as directed. |
| 8 | Supply and fixing in replacement Integral LED security light luminaire 90W LED 230 volts made of pressure die cast aluminium housing with high power LED’s lens & toughned glass IP-66 suitable for mounting existing bracket of size 32/40mm dia G I pipe, fixing clamps ,bolts, nuts of suitable size as required at site complete all as specified and as directed. |
| 9 | Supply and fix Integral LED security light luminaire 60W LED 230 volts made of pressure die cast aluminium housing with high power LED’s lens & toughned glass IP-66 suitable for mounting existing bracket of size 32/40mm dia G I pipe, fixing clamps ,bolts, nuts of suitable size as required at site complete all as specified and as directed. |
| 10 | Supply and fix Integral LED security light luminaire 35W LED 230 volts made of pressure die cast aluminium housing with high power LED’s lens & toughned glass IP-66 suitable for mounting existing bracket of size 32/40mm dia G I pipe, fixing clamps ,bolts, nuts of suitable size as required at site complete all as specified and as directed. |
| 11 | Supply and fix Integral LED security FLOOD light luminaire 120W LED 230 volts made of pressure die cast aluminium housing with high power LED’s lens & toughned glass IP-66 suitable for mounting existing bracket of size 32/40mm dia G I pipe, fixing clamps ,bolts, nuts of suitable size as required at site complete all as specified and as directed. |
| 12 | M&L outdoor type street light junction boxes with PVC water tight encloser, ready made type, with provision of suitable aluminium bus bars for three phases and one neutral mounted on insulators and bus bar having provision of 10 A SP MCB terminal connection and inter connection of street light from pole to pole and pole to light fittings including necessary PVC insulated waather proof twin core 2.5 Sqmm (nominal area) aluminium conductor cable, 1100 volts grade drawn and including PVC conduit of suitable size with clamps (3 Nos) , nuts, bolts etc from Junction box to street light connection, including taking down of existing unserviceable of junction box complete all as specified and as directed. |
| 13 | M&L for steel tubular poles complete with cast iron base plate, final taper plug, bolt, nuts and screws as specified type 410 SP-31(9 mtr long). Including painting pole with two coats of bituminous paint internally and external embedded portion in ground concrete and painting exposed surface with two coats of aluminum paint over one coats of aluminum paint over one coat of red oxide primer including taking down of existing LT pole of any size and re-fixing of chaneel, insulator and electric connection etc, all as specified and directed. |
| 14 | Supply and laying XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked as per IS 7098-I laid in trenches ducts or fixing or passing through GI pipe across the road/path/drains/along wall/floor/equipment etc. cross sectional area 50 Sqmm 3.5 core with necessary cable lugs, ncluding taking down unserviceable cable, complete all as specified and directed. |
| 15 | All as per item no- 14 here in before but 25 Sqmm 3.5 core |
| 16 | All as per item no- 14 here in before but 16 Sqmm 4 core |
| 17 | All as per item no- 14 here in before but 16 Sqmm 2 core |
| 18 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation, laying of pipe etc and not exceeding 10 sqm on plan for manhole etc and getting out in soft/loose soil, complete all as specified and directed. |
| 19 | Excavation in trenches not exceeding 1.5 mtr wide and exceeding 1.5 mtr in depth for foundation, laying of pipe etc and not exceeding 10 sqm on plan for manhole etc and getting out in soft/loose soil, complete all as specified and directed. |
| 20 | Returning , filling in , with approved excavated soil including spreading levelling watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed. |
| 21 | Removing excavated material (soils) to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 22 | Supply and laying dry burnt bricks, sub class ‘B’ old size in cable trenches, as cable protection complete all as specified and directed. |
| 23 | M&L for dry sand cushioning to under ground electric cable on layer of 08 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified in clause 19.75 of M.E.S Schedule Part-I complete all as specified and directed. |
| 24 | M&L for Cutting/Boring of road/Hard standing to a size of 30 cm in width and not exceeding 60 cm in depth for laying of protection pipe/water line/Cable including returning filling, Including spreading and providing PCC in 1:2:4 B1 using 20 mm grade stone aggregate for the top 100mm layer, complete all as specified and directed. |
| 25 | Supply and laying galvanised iron pipe 40mm bore light grade fixed to poles with steel clamps laid under road crossing, fixed to wall etc complete all as specified and directed. |
| 26 | Material and labour for P.C.C (1:3:6) type C-2 using 40 mm graded aggregate as in foundation of pole and filling of mass concrete including providing necessary form work complete all as specified and as directed. |
| 27 | M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in coping to existing and new poles including necessary form work removing the debris to a distance n.exc. 50m complete all as specified and as directed. |
| 28 | Material & Labour for fabrication of Sheet metal enclosure , powder coated of Timelite Distribution Boards for automatic Switching of street lights internally pre wired by using suitable copper lugs including fixing with MS Clamp40X5 mm to steel/RCC poles incl connection consisting of the following (i) ASTRONOMICAL time switch 24 hrs operation 240 Volts complete all as specified and as directed. |
| 29 | M&L for street light bracket made out of 32 mm dia GI pipe medium grade 120 cm long cut to size and bend to shape , fixing on poles with flat iron clamps 40mm x 6 mm – 02 sets including nuts, bolts and washers including one coat of aluminium pait over acoat of red oxide primer including taking down of old unserviceable complete all as specified and as directed. |
| 30 | Earthing complete with galvanised steel earth plate electrode 60cmx60cm.x6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts,nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part I 2009 connected to earthing test point, 20 mm bore medium grade GI watering pipe, 15mm bore light grade GI protection pipe, PCC chamber with RCC cover, funnel with wire mesh etc including necessary test including taking down of existing earthing, on completion all as specified and as directed. |
| 31 | Servicing of DG Set 250 KVA of any Make, checking entire system as per manufacturer's catalogue such as checking all parts for serviceeablility, taking down defective parts such as fuel filter assy, by pass filter assembly, lub oil filter assembly, air cleaner assy, flexible hose pipe, coolent etc and replacing the same with same size, make and capacity of parts, draining out the old used burnt engine oil from the sump cleaning all serviceable filters and oil sump with cleaning solution such as petrol/ diesel and refilling new engine oil upto required level and including testing to DG Set to entire satisfaction of Engr-in Charge. Note:-(i) Spare parts/ Engine oil/ Check kit/ filter shall be measured and paid for saperately under respective items of BOQ as 'Supply only'. (ii) Minimum 6 months gap/ 200 Hrs of run whichever is earlier shall be considered for next service. (iii) Repair guarantee for replaced parts/ servicing of DG Set shall be for six month/ 200 Hrs run from the date of service whichever is earlier.(iv) Cost of small spares required for maint of DG set shall be deemed to be included in the unit rate quoted by the contractor |
| 32 | All as per item No 31 here-in-before but for DG set 125 KVA. |
| 33 | All as per item No 31 here-in-before but for DG set 100 KVA. |
| 34 | All as per item No 31 here-in-before but for DG set 62.5 KVA. |
| 35 | All as per item No 31 here-in-before but for DG set 40 KVA. |
| 36 | All as per item No 31 here-in-before but for DG set 30 KVA. |
| 37 | All as per item No 31 here-in-before but for DG set 20 KVA. |
| 38 | Supply only lubricant oil filter (OEM manufactured) suitable for 250 KVA DG set, complete all as specified & directed |
| 39 | Supply only lubricant oil filter (OEM manufactured) suitable for 125 KVA DG set, complete all as specified & directed. |
| 40 | Supply only lubricant oil filter (OEM manufactured) suitable for 100 KVA DG set, complete all as specified & directed. |
| 41 | Supply only lubricant oil filter (OEM manufactured) suitable for 62.5 KVA DG set, complete all as specified & directed. |
| 42 | Supply only lubricant oil filter (OEM manufactured) suitable for 40 KVA DG set, complete all as specified & directed. |
| 43 | Supply only lubricant oil filter (OEM manufactured) suitable for 30 KVA DG set, complete all as specified & directed. |
| 44 | Supply only lubricant oil filter (OEM manufactured) suitable for 20 KVA DG set, complete all as specified & directed. |
| 45 | Supply only fuel filter (OEM manufactured) with set of 'O' Ring for 250 KVA DG set, complete all as specified & directed. |
| 46 | Supply only fuel filter (OEM manufactured) with set of 'O' Ring for 125 KVA DG set, complete all as specified & directed. |
| 47 | Supply only fuel filter (OEM manufactured) with set of 'O' Ring for 100 KVA DG set, complete all as specified & directed. |
| 48 | Supply only fuel filter (OEM manufactured) with set of 'O' Ring for 62.5 KVA DG set, complete all as specified & directed. |
| 49 | Supply only fuel filter (OEM manufactured) with set of 'O' Ring for 40 KVA DG set, complete all as specified & directed. |
| 50 | Supply only fuel filter (OEM manufactured) with set of 'O' Ring for 30 KVA DG set, complete all as specified & directed. |
| 51 | Supply only fuel filter (OEM manufactured) with set of 'O' Ring for 20 KVA DG set, complete all as specified & directed. |
| 52 | Supply only air filter (OEM manufactured) inner & outer suitable for 250 KVA DG set, complete all as specified & directed. |
| 53 | Supply only air filter (OEM manufactured) inner & outer suitable for 125 KVA DG set, complete all as specified & directed. |
| 54 | Supply only air filter (OEM manufactured) inner & outer suitable for 100 KVA DG set, complete all as specified & directed. |
| 55 | Supply only air filter (OEM manufactured) inner & outer suitable for 62.5 KVA DG set, complete all as specified & directed. |
| 56 | Supply only air filter(OEM manufactured) inner & outer suitable for 40 KVA DG set, complete all as specified & directed. |
| 57 | Supply only air filter (OEM manufactured) inner & outer suitable for 30 KVA DG set, complete all as specified & directed. |
| 58 | Supply only air filter (OEM manufactured) inner & outer suitable for 20 KVA DG set, complete all as specified & directed. |
| 59 | Supply only Rocker cover / sump packing kit (OEM manufactured) suitable for 250 KVA DG set, complete all as specified & directed. |
| 60 | Supply only Rocker cover / sump packing kit (OEM manufactured) suitable for 160/100/62.5 KVA DG set, complete all as specified & directed. |
| 61 | Supply only Fuel line (OEM manufactured) complete with clamps suitable for 250/160/100 KVA DG set, complete all as specified & directed. |
| 62 | Supply only Fuel line (OEM manufactured) complete with clamps suitable for 62.5/40/30/20 KVA DG set, complete all as specified & directed. |
| 63 | Supply only Low lube oil pressure sensor (OEM manufactured) complete suitable for 15/ 20/ 25/ 30/ 40/ 62.5 KVA DG set, complete all as specified & directed. |
| 64 | Supply only Water hose pipe kit (OEM manufactured) complete with clamps, nuts & bolts suitable for 15/ 20/ 25/ 30/ 40/ 62.5 KVA DG set, complete all as specified & directed. |
| 65 | Supply and changing engine oil 15W/ 40, complete all as specified and as directed. |
| 66 | Supply and changing coolent complete all as specified and as directed. |
| 67 | Supply and changing distilled water in for filling in batteries all as specified and as directed. |
| 68 | S&F in replacement maintenance free lead acid battery 12 volts 180 AH confirming to IS 7372 complete all as specified and as directed. |
| 69 | S&F in replacement maintenance free lead acid battery 12 volts 150 AH confirming to IS 7372 complete all as specified and as directed. |
| 70 | S&F in replacement maintenance free lead acid battery 12 volts 130 AH confirming to IS 7372 complete all as specified and as directed. |
| 71 | S&F in replacement maintenance free lead acid battery 12 volts 90 AH confirming to IS 7372 complete all as specified and as directed. |
| 72 | Supply and fix in repair on load change over switch in sheet metal enclosure 63Amp four pole,modular type,positive isolation,door interlock and padlock facility confirming to IS/IEC 60947-3 complete all as directed. |
| 73 | Supply and fix in repair on load change over switch in sheet metal enclosure 100Amp four pole,modular type,positive isolation,door interlock and padlock facility confirming to IS/IEC 60947-3 complete all as directed. |
| 74 | Supply and fix in repair on load change over switch in sheet metal enclosure 160Amp four pole,modular type,positive isolation,door interlock and padlock facility confirming to IS/IEC 60947-3 complete all as directed. |
| 75 | Supply and fix in repair on load change over switch in sheet metal enclosure 200Amp four pole,modular type,positive isolation,door interlock and padlock facility confirming to IS/IEC 60947-3 complete all as directed. |
| 76 | Supply and fix in repair on load change over switch in sheet metal enclosure 400Amp four pole,modular type,positive isolation,door interlock and padlock facility confirming to IS/IEC 60947-3 complete all as directed. |
| 77 | S&F in replacement, MCCB, four pole, 400 Amp 415 volts, 50 Hz breaking capacity not less than 36 kA,thermal magnetic release,adjustable overload 80-100% and fixed short circuit10In confirming to IS/IEC 60947-2 complete with spreader links all as specified and as directed. |
| 78 | S&F in replacement, MCCB, four pole, 315/320 Amp 415 volts, 50 Hz breaking capacity not less than 36 kA,thermal magnetic release,adjustable overload 80-100% and fixed short circuit10In confirming to IS/IEC 60947-2 complete with spreader links all as specified and as directed. |
| 79 | S&F in replacement, MCCB, four pole, 200 Amp 415 volts, 50 Hz breaking capacity not less than 25 kA,thermal magnetic release,adjustable overload 80-100% and fixed short circuit10In confirming to IS/IEC 60947-2 complete with spreader links all as specified and as directed. |
| 80 | S&F in replacement, MCCB, four pole, 160 Amp 415 volts, 50 Hz breaking capacity not less than 25 kA,thermal magnetic release,adjustable overload 80-100% and fixed short circuit10In confirming to IS/IEC 60947-2 complete with spreader links all as specified and as directed. |
| 81 | S&F in replacement, MCCB, four pole, 100 Amp 415 volts, 50 Hz breaking capacity not less than 25 kA,thermal magnetic release,adjustable overload 80-100% and fixed short circuit10In confirming to IS/IEC 60947-2 complete with spreader links all as specified and as directed. |
| 82 | S&F in replacement, MCCB, four pole, 63 Amp 415 volts, 50 Hz breaking capacity not less than 25 kA,thermal magnetic release,adjustable overload 80-100% and fixed short circuit10In confirming to IS/IEC 60947-2 complete with spreader links all as specified and as directed. |
| 83 | M&L for taking down/ Dismantling of unserviceable self starter 12 volts from engine of DG Set , opening of stator and armature for repairing by replacing the worn out carbon brushes, brush holder, bearings, ignition / solenoid coil, replacement of burnt armature, rewinding of field coils, replacement of pinion gears, bushing etc, complete servicing , varnishing of stator /armature and refixing after repair, testing / commissioning complete for DG Set of any capacity, complete all as specified & directed. |
| 84 | S&F battery terminals (positive and negative) brass heavy duty complete suitable for fixing on battery poles with bolts, nuts and washers complete including taking down old unserviceable battery terminals, complete all as specified & directed. |
| 85 | Taking down existing worn out battery charging dynamo belt & water pump fan belt (V Belt) from the following capacity of DG set installed at various installations and supply and fixing with new fan belt of same specifications, complete & specified and as directed :- |
| 86 | Up to 30 KVA |
| 87 | 40 to 62.5 KVA |
| 88 | 100 to 250 KVA |
| 89 | Taking down the existing turbo charger unit from the capacity 30KVA Diesel engine, transporting to private work shop, dismantling opening including replacement of worn out bearing, bushes, fanblade, gaskets, o ring, seal etc, and reassembling testing/ connecting, complete all as specified & directed . |
| 90 | 40 to 62.5 KVA |
| 91 | Taking down brunt unserviceable automatic voltage regulator assy from alternator of DG set by disconnecting its electrical connections, supply and fixing new AVR 12V suitable for 15 to 100 KVA DG Set including connecting all electrical connections, testing voltage after starting engine and setting properly complete all as specified & directed. |
| 92 | M&L for disconnecting, removing and dismantling radiator assembly from the following capacity DG sets and descaling the radiator throughly with CTC solution/ any other chemical solvent agent as approved by the Engineer-in-charge, stopping of leakage at place to copper cores and tubes by brazing scrapping the existing oil paint, dusting and painting the radiator with enamelled paint etc., re-installing and commissioning complete all as specified & directed :- |
| 93 | Up to 30 KVA |
| 94 | 40 to 62.5 KVA |
| 95 | 100 to 250 KVA |
| 96 | Taking down existing unserviceable water pump assembly of following capacity DG sets installed at various installation and replace with new water pump assembly (OEM Manufactured), complete all as specified & directed :- |
| 97 | Up to 25 KVA |
| 98 | 25 to 40 KVA |
| 99 | 50 to 62.5 KVA |
| 100 | 100 to 250 KVA |
| 101 | Dismantling the alternator in parts and removing the burn out copper winding coil carefully, cleaning slots and replacing the insulation paper and re-winding 'F' class copper conductor winding wire of existing size/ shape, glass sleeves of connecting leads, binding/ tightening loose coils with binding cloths, varnishing and applying the bactol on the excitor coil/ winding with supper varnish, heating the windings at appropriate tempeature to achive required insulation resistance with out damaging the other parts, replacement of driving and non-driving end bearings, cleaning, greasing, reassembling and testing with megger for insualtion resistance etc., complete all as specified and as directed :- |
| 102 | Up to 30 KVA |
| 103 | 40 to 62.5 KVA |
| 104 | 100 to 250 KVA |
| 105 | Taking down existing defective injector and fuel injection pump (FIP) for the following capacity DG set installed at various installation and replacement of worn out spares like delivery valves, nozzles, bearings, fly weight, packing kit, and copper washer kit, injector element, kit injector, retainer injector cup, fixing tappit cover packing set and recalibration of FIP and refixing in same position and testing of full load checking of pressure and adjustment by dial gauge complete all as specified and as directed :- |
| 106 | Up to 30 KVA |
| 107 | 40 to 62.5 KVA |
| 108 | 100 to 250 KVA |
| 109 | Dismantling of unserviceable battery charging dynamo of 12 Volts from DG set of capacity 15 KVA to 62.5 KVA, repair and servicing of dynomo including replacement of bushes, bearings, carbon brushes, rectifires, rewinding of field magnet coil / rotor armeture coils and any other minor parts required for smooth functioning and refixing on DG set after repair/service including testing after commissioning, complete all as specified & directed. |
| 110 | Dismantling of unserviceable battery charging dynamo of 12 Volts from DG set of capacity 62.5 KVA to 250 KVA, repair and servicing of dynomo including replacement of bushes, bearings, carbon brushes, rectifires, rewinding of field magnet coil / rotor armeture coils and any other minor parts required for smooth functioning and refixing on DG set after repair/service including testing after commissioning, complete all as specified & directed. |
| 111 | M&L for Electronic type Starting Switch suitable for 62.5 KVA to 250 KVA DG set including taking down old unserviceable switch, complete all as specified & directed. |
| 112 | M&L for Electronic type Starting Switch suitable for 15KVA to 62.5 KVA DG set including taking down old unserviceable switch, complete all as specified & directed. |
| 113 | M&L for Feed pump (OEM manufactured) suitable for 7.5 KVA to 62.5 KVA DG set including taking down old unserviceable pump, complete all as specified & directed. |
| 114 | Taking down the existing defective DC ammeter and volt meter from the panel and replace with new combined DC ammeter and volt meter including necessary wiring & wiring material, complete all as specified & directed . |
| 115 | Engine safety unit (ESU) alongwith meter for pressure, fuel, RPM etc. with all electrical instruments and accessories including testing and taking down old unserviceable ESU, complete all as specified & directed. |
| 116 | M&L for fabrication and fixing in replacement of glow sign board made out of plain Galvanized M.S. Sheet of thickness 1.0 mm duly mounted on MS angle 20x20x3mm duly fixed by screwes and the front side covered with 3.0 mm thick white acrylic sheet and further covered with Dark Blue Vinyl sheet duly cut the letterrings by computerized cutting plotter and pasted on the acrylic sheet and fixed properly with the frame structure by means of nuts/bolts/washers etc. including 05 Nos 20 watt Led tube light fittings and necessary electrical connections with 1100 v grade PVC insulated multi flexible copper wire of size 1.5 sqmm complete all as specified and as directed All as specified and directed. NOTE:- letter to be written will be as directed by Engr-in-charge/GE |
| 117 | M&L for Door hinges suitable for any capacity / size of DG set canopy at different locations including taking down old unserviceable/ broken hinges, complete all as specified & directed. Please Enable Macros to View BoQ information |