| 1 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 2 | Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. Ordinary rock |
| 4 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 6 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 7 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 8 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 9 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 10 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Light shade pigment using white cement |
| 11 | Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil |
| 12 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). |
| 13 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar |
| 14 | 15mm cement plaster in single coat on rough side of single or half brick wall for interior plastering upto floor two level including internal rounded angles chamfers, and/or rounded angles not excedding 80mm in girth and finished even and smooth. In 1 cement : 4 fine sand |
| 15 | Finishing walls with Exterior emulsion Paint(Apex) of approved brand and manufacture and of required shade on undecorated wall surface to give even over @ 1.25 ltr/10 sqm including one coat of primer applied @ 0.75ltr/10 sqm coat curing and cost of all material, labour, T&P etc required for proper completion of work for two coat |
| 16 | Dismantling existing plaster including disposal of refuse as directed by engineer in charge within 60 metres lead. |
| 17 | Providing and applying white cement based putty of average thickness of 1mm, of approved brand and manufacturer over the plastered wall surface to prepare the surface even and smooth including cost of material, labour T&P etc all complete. |
| 18 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels Granite stone slab of colour black, Cherry/Ruby red 8.2.2.1 Area of slab upto 0.50 sqm |
| 19 | Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-incharge. |
| 20 | Centring Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick |
| 21 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 22 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Second class teak wood |
| 23 | Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete |
| 24 | Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. |
| 25 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 26 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 27 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “T” of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending |
| 28 | Providing and fixing in position wall panelling at all heights with integral densified calcium silicate panels/tiles of size 595 x 595 mm, having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity . With 15 mm thick fully perforated square/butt edge light weight calcium silicate panels/ tile |
| 29 | Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 30Watt. to 40 Watt. Confirming to IP 66 protection complete in all respect. CAT- AAA |
| 30 | Supply, Installation,Testing and Commissioning of LED RGB/RGBW flood lighting luminaire for facade lighting with Die-cast aluminium housing, powder-coated finish, of following wattage. Luminaire shall be capable of producing dynamic color changing light for with 16 million colors by DMX/Ethernet based control.The beam angle of the fitting shall be narrow, medium,wide or asymmetric as per the requirement. Luminaire shall be completewith driver and capable of operating at line voltage without any separate power supply from100-270VAC,50Hz with power factor>0.9.Fixture shall be suitable to operate at an ambient temperature range of 10°Cto+50°CandshallbeIP65andIK06rated.Lifetimeshallbeat least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS (IS 10322) and shall be completewith all necessary accessories required for proper working of fixture includingweatherproofconnectioncables,waterproofconnectors etc. as required 75 W |
| 31 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 6 sq. mm 3 core |
| 32 | S&F of 6 Amp to 32 Amp. SPMCB (10 KA) C Curve , CAT A |
| 33 | Supply and wiring of submain with two number 1.5 sq.mm. PVC insulated 1100 V grade single core aluminium conductor cable in 20 mm dia. heavy guage rigid steel conduit concealed in wall complete with one number 8 SWG GI earth continuity wire etc.,complete in all respects including matching colour wash etc. complete in all respect. but in 20 mm dia heavy duty (2mm thick) PVC conduit with 1 number 1.5 sq. mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor as earth continuity wire. |
| 34 | Add for light / fan points with modular type switch in place of piano type switch. |
| 35 | Add for plug point with modular switch & socket in place of piano type switch & socket. |
| 36 | Supply and fixing of electronic fan dimmer(Modular) 300/400 watt, ISI marked, on the existing switch board including making connections, required material, labour T&P etc. for proper completion of work to the satisfaction of Engineer in charge of work. |
| 37 | Supply and fixing of recess/ Surface/ Pendent mounting round 10 to 15 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. CAT- AAA |
| 38 | Supply and wiring of submain with two number 1.5 sq.mm. PVC insulated 1100 V grade single core aluminium conductor cable in 20 mm dia. heavy guage rigid steel conduit partly laid in slab with reinforcement before concreting and partly concealed in wall, with one no. 8 SWG GI earth continuity wire etc. complete in all respects including matching colour wash. but in 20 mm dia heavy duty (2mm thick) PVC conduit with 1 nos. 1.5 sq. mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable as earth continuity wire drawn inside the conduit complete in all respect. |
| 39 | Wiring point for exhaust fan in 2.5 sq. mm. PVC insulated single core aluminium conductor cable (drawn through existing concealed steel conduit) and 15 Amp flush type switch & ceiling rose fixed with 3 mm thick phenolic laminated bakalite sheet with brass machine screws and cup washers mounted over the existing M.S. box / junction box required for proper completion of the work, as directed at site by the Engineer in charge. |
| 40 | S&F of 16 Amp. 240 V SPN metal clad rewireable type switch fuse unit on M.D.F.E.G. / Teak wood board complete in all respect. |
| 41 | S&F of 6 Amp to 32 Amp. SPMCB (10 KA) C Curve Cat A |
| 42 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 43 | Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil |
| 44 | Ploughing the existing ground to a depth of 15 cm to 25 cm and watering the same – All kinds of soil |
| 45 | Mixing of good earth and sludge/manure in required proportion by mechanical/manual means including carriage within 50 m |
| 46 | Providing and laying Neelgiri/Mexican grass turf with earth 50–60 mm thick, properly rammed, rolled, watered and maintained for 30 days |
| 47 | Providing & laying Selection No.1 Doob grass turf 50–60 mm thick with ramming, rolling, watering & 30 days maintenance |
| 48 | Supplying & stacking of Selection No.1 Doob grass turf, fresh & free from weeds, with proper roots including loading/unloading and carriage |
| 49 | Plantation of Trees at site including watering and removal of unserviceable materials, excluding cost of plant & water |
| 50 | Supply of medium trees (e.g. Neem, Ashoka, Gulmohar, Ficus, etc.) – average nursery rate |
| 51 | Supplying ornamental shrubs of approved variety, well grown in polybags/pots, with fresh foliage |
| 52 | Cutting/maintenance of hedge/edge, removing cut materials, cleaning, watering, manuring (excluding material cost) |
| 53 | Cleaning and Sweeping of Lawn / Garden area and keep it neat and clean by mechanized method / manually, remove litter,debries, picking of leaves, papers, plastic bottles etc. including disposal of collected waste in dustbin/ designated place, as per direction of officer -in- charge (All T & P, materials/ articles shall be provided by the contractor.)For Prestigious Area |
| 54 | Removal of garden waste by TATA 407 or equivalent including loading/ unloading and carriage upto 1 km lead,complete disposal upto designated place as per direction of officer-in-charge . |
| 55 | FRP Garden Bench, Size 5x3x3 |
| 56 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 57 | sculpture 12' |
| 58 | Army man 10' |
| 59 | FRP Outdoor Playground Equipment's , Kids Outdoor Multi Play Station , Playground Slide, Size 26x26x14 ft |
| 60 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 15 mm nominal dia Pipes |
| 61 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 20 mm nominal dia Pipes |
| 62 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal dia Pipes |
| 63 | Providing & fixing CP brass bib cock (heavy duty) |
| 64 | Providing & fixing CP brass pillar cock |
| 65 | Providing & fixing CP brass angle valve |
| 66 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 250 mm |
| 67 | Providing and fixing PVC Waste pipe for wash basin including PVC Waste fitting complete |
| 68 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 69 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 70 | Providing and fixing white vitreous china water closet squatting pan (Indian type) : Orissa Pattern W.C. pan |
| 71 | Providing and fixing soil, waste and vent pipes : 100 mm dia Sand cast iron S&S pipe as per IS: 1729 |
| 72 | Providing and fixing soil, waste and vent pipes : 75 mm dia Sand cast iron S&S pipe as per IS: 1729 |
| 73 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 150 x 100 mm size P type |
| 74 | Add 18 % GST Please Enable Macros to View BoQ information |