| 1 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 2 | Material and labour for Plain cement concrete 1:4:8 type D2 using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and directed. |
| 3 | Material and labour Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed. |
| 4 | Material and labour for cement concrete type B1 1:2:4 using 20mm graded stone aggregate as in coping complete all as specified and directed. |
| 5 | Material and labour for Rendering 10mm thick in cm 1:4 on brick/concrete surfaces finished fair and even without using extra cement complete all as specified and directed. |
| 6 | Material and labour for preparation of new plastered surfaces on walls and applying two coats of cement base paint over a coat of primer complete all as specified and directed. |
| 7 | Surface dressing n exc 15 cm deep in soft/loose soil complete all as specified and directed. |
| 8 | Material and labour for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 9 | Material and labour 75 mm thick Cement concrete type C- 2, 1:3:6 (40mm graded aggregate) as in plinth protection complete all as specified and directed. |
| 10 | Material and labour for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed. |
| 11 | Supply and fixing Welded steel wire fabric weight n exc 4 Kg/Sqm fixed to steel members complete all as specified and directed. |
| 12 | Supply and fixing Aluminum alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and directed. |
| 13 | Material and labour for preparation of new steel surfaces of any description exc 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and directed. |
| 14 | Returning filling including spreading levelling watering and well ramming in layers not exceeding 25 cm in soil complete all as specified and directed. |
| 15 | Removing excavated surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point all as directed complete all as specified and directed. |
| 16 | Supply and fixing HDPE double layered Rotational moulded water storage tanks 500 lit capacity white color (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed. |
| 17 | Supply and fixing Ball brass valves for 20mm bore dia of pipe, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed. |
| 18 | Supply and fixing Gun-metal, globe or gate valves for 20mm bore dia of pipe, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 19 | Supply and fixing Unplasticised PVC pipes 20mm bore of pipe of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe complete all as specified and directed. |
| 20 | Supply and fix GI Tubing medium grade including provision of necessary fittings like Tee,Bend,Socket,Elbow,Short pieces connectors,plugs,unions,etc and accessories laid in trenches for the following sizes complete all as specified and directed. |
| 21 | (a) 40mm bore steel tubing |
| 22 | (b) 50mm bore steel tubing |
| 23 | Supply and fix GI Tubing medium grade including provision of necessary fittings Tee,Bend,Socket,Elbow,Short pieces connectors,plugs,unions,flange etc and accessories on walls/roof for the following bore sizes complete all as specified and directed. |
| 24 | (a) 40mm bore steel tubing |
| 25 | (b) 50mm bore steel tubing |
| 26 | Supply and fixing of gun metal gate valve,40mm bore, painted finish, with forged brass spindle and iron wheel head,screwed both ends internally IS-778 marked, class-2, for iron pipe complete all as specified and directed |
| 27 | Supply and fix 40mm dia brass float valve,ISI marked high pressure with polythene float and fly nut complete,screwed including necessary GI fittings such as elbow , reducer, nipple etc complete all as specified and directed. |
| 28 | Supply and fix Non return sluice valve class PN 1.6 , 50 mm dia including flange joint with rubber ,bolts , nuts and washers complete all as specified and directed by Eng-in-Charge |
| 29 | Supply and fix Cast Iron Foot valve ,Flanged , conforming to IS 4038 , 50mm (2\\") dia . Foot valve shall have PN 0.2 Housing - Cast iron is 210 Gr FG200 , Strainer -Cast Iron IS 210 Gr FG 200 , Door - Cast Iron IS 210 Gr FG 200 ,Door plate - Cast Iron IS 210 Gr FG 200 , Door Face Natural Rubber , SS 410 Fastners - CS IS : 1367 , CL-4.6/4.0 complete all as specified and directed |
| 30 | Supply and fix three phase monoblock Pumpset 1Hp ,0.75kW ,415V,6-18m head range , 5.42 litres per second discharge , suction and delivery pipe size 50mm and 40mm respectively , along with foundation bolts & foundation bed as recommended by OEM complete all as specified and directed by Eng-in-Charge.Make : Kirloskar , Model :GMC 116++ or equivalent |
| 31 | Supply , erection ,testing of maintenance free chemical earthing by auguring & installation of copper bonded rod using machine bore and filling with backfill compund using copper bonded rod of dia 20mm , length 3m , made of low carbon high tensile steel with copper plated (250+ microns) for preventing external corrosion, with top end connected with copper plated welded busbar terminal of dimension 150mm*150mm*6mm , complete conforms to IS: 3043 - 1987 and carbon based , high conductive backfill compound 'Conductolite' with resitivity < 0.5 ohm -metre (In dry conditions) & resitivity is non-moisture dependant , pH Value : 8.0 -9.0, electronic &ionic conduction,less susceptible to shrinkage , with hygroscopic & corrosion resisitive properties and covering with heavy duty polyplastic earth pit chamber cover .Make : M/s Ashlok Safe Earthing Electrode Limited or equivalent |
| 32 | Material and Labour for 4mm dia galvanized iron earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all as specified and as directed by the Engineer-in-Charge |
| 33 | Material and labour for rendering 10mm thick in cement mortor 1:6 on fair faces of brick work or concrete surfaces complete all as specified and as directed by the Engineer-in-Charge complete all as specified and directed. |
| 34 | Material and labour for fixing valve chamber cover in replacement, fabricated from MS sheet 3mm thickness. fixing Angle at all sides with two Nos of hinges and one No. handle made out of MS round bar 10mm dia with necessary locking arrangement complete all as specified and as directed by the Engineer-in-Charge. |
| 35 | Spreading of riddled earth obtained from trenches for cable cushioning on top and bottom of cable for cable protection complete all as specified and directed. (Note: Only punned thickness of riddled earth shall be measured) |
| 36 | Supply and lay bricks in trenches, common burnt clay building bricks, RM subclass 'B' designation 75, old size, with width equal to the length of the brick; complete all as specified and directed. |
| 37 | 6. Supply and lay LT under ground cable 1100 volts grade Crosslinked Polyethylene (XLPE) insulated PVC Sheathed Cables: armoured multistranded heavy duty electric cable with aluminium conductor laid in trenches/duct/walls including cable gland and lugs on both end termination including laying, connecting to various switches in panel board, testing and commissioning for following sizes complete all as directed & as specified- |
| 38 | (a) 3.5 Core 25 Sqmm |
| 39 | (b) 3 Core 10 Sqmm |
| 40 | Supply, installation in replacement, testing and commissioning of outdoor LT feeder pillar box panel board, CPRI Approved, made out of CRCA sheet 3.15 mm thick vermin proof factory made with 40 x 40 x6 mm MS angle/channel duly painted with two coats of synthetic enamel powder coated paint over a coat of metal primer with bus bar chamber comrising of high conductivity copper bus bar of capacity 200 Amps three phase and half the capacity for neutral including voltmeter, Ammeter selector switches, PCC foundation suitable to accommodate the following as specied and as directed.:-INCOMING(a) MCCB 415 V,63 A, 4 pole breaking capacity 16 KA-01 Nos.(b) Digital Panel Meter Multifunctional type with CT Coil for Amps, Volts, KWH, Power Factor and other parameters flush mounting with LED indication lamp complete and all as per standard pratice-1 No. |
| 41 | OUT GOINGa) MPCB, Rating -10 A suitable for 3 HP motor, 415V-2 Nosb) DOL Starter suitable for motor 3 HP with Control MCB,main contactor, auxillary Contactor, Push Botton (stop & start Functioning). over load relay, single phase preventor- 2 nos.c) MPCB, Rating -10 A suitable for 1 HP motor, 415V - 2 Nos d) DOL Starter suitable for motor 1 HP with Control MCB, main contactor, auxillary Contactor, Push Botton (stop & start Functioning). over load relay, 2 nos.e) MCB,, 415V 10KA 'C' curve, TP 10 A-2 No.f) MCB, 240 V, 10 kA, B curve, DP 10 A-2 No.g) Digital Panel Meter Multifunctional type with CT Coil for Amps, Volts, KWH, Power Factor and other parameters flush mounting with LED indication lamp complete and all as per standard pratice - 4 Nos Note:-(i) All MCCBs/instruments/MCBs/Bus Bar shall be housed in a separate housing with on-off latches in the housing and LED indication lamp for for incomer & each outgoing complete and all as per standard practice. (Pump Panel) |
| 42 | Supply , erection ,testing of maintenance free chemical earthing by auguring & installation of copper bonded rod using machine bore and filling with backfill compund using copper bonded rod of dia 20mm , length 3m , made of low carbon high tensile steel with copper plated (250+ microns) for preventing external corrosion, with top end connected with copper plated welded busbar terminal of dimension 150mm*150mm*6mm , complete conforms to IS: 3043 - 1987 and carbon based , high conductive backfill compound 'Conductolite' with resitivity, (In dry conditions) & resitivity is non-moisture dependant electronic &ionic conduction,less susceptible to shrinkage , with hygroscopic & corrosion resisitive properties and covering with heavy duty polyplastic earth pit chamber cover complete all as specified and directed. |
| 43 | Material and Labour for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe orfixed to poles or any other indicated situation for loop earthing etc. as required 20x3mm copper strip complete all as specified and as directed by the Engineer-in-Charge Please Enable Macros to View BoQ information |